RESUMO
PURPOSE: The purpose of the present work is to measure the interocular upper lid contour symmetry using a new method of lid contour quantification. METHODS: The Bézier curve tool of the Image J software was used to extract the right and left upper eyelid contours of 75 normal subjects. Inter-observer variability of 29 right lid contours obtained by two independent observers was estimated using the coefficient of overlap of two curves and an analysis of the differences of the contour peak location. A two-way analysis of variance was used to test the mean value of the coefficient of overlap of the right and left contours in males and females and lid segments. The same analysis was performed to compare the location of the contour peak of the right and left contours. RESULTS: The coefficient of contour overlap obtained by independent observers ranged from 93.5% to 98.8%, with a mean of 96.1% ± 1.6 SD. There was a mean difference of 0.02 mm in the location of the contour peak. Right and left contour symmetry did not differ between females and males and was within the range of the method variability for contour overlap and location of the contour peak. CONCLUSIONS: The upper eyelid contour is highly symmetrical. Bézier lines allow a quick and fast quantification of the lid contour, with a mean inter-observer variability of 3.9%.
Assuntos
Pálpebras/anatomia & histologia , Assimetria Facial/diagnóstico , Adulto , Simulação por Computador , Feminino , Humanos , Masculino , Valores de Referência , Processamento de Sinais Assistido por Computador , SoftwareRESUMO
ABSTRACT Purpose: The purpose of the present work is to measure the interocular upper lid contour symmetry using a new method of lid contour quantification. Methods: The Bézier curve tool of the Image J software was used to extract the right and left upper eyelid contours of 75 normal subjects. Inter-observer variability of 29 right lid contours obtained by two independent observers was estimated using the coefficient of overlap of two curves and an analysis of the differences of the contour peak location. A two-way analysis of variance was used to test the mean value of the coefficient of overlap of the right and left contours in males and females and lid segments. The same analysis was performed to compare the location of the contour peak of the right and left contours. Results: The coefficient of contour overlap obtained by independent observers ranged from 93.5% to 98.8%, with a mean of 96.1% ± 1.6 SD. There was a mean difference of 0.02 mm in the location of the contour peak. Right and left contour symmetry did not differ between females and males and was within the range of the method variability for contour overlap and location of the contour peak. Conclusions: The upper eyelid contour is highly symmetrical. Bézier lines allow a quick and fast quantification of the lid contour, with a mean inter-observer variability of 3.9%.
RESUMO Objetivo: O objetivo do presente estudo é mensurar a simetria interocular do contorno da pálpebra superior por meio de um novo método de quantificação de contorno palpebral com curvas de Bézier. Métodos: A ferramenta de curva de Bézier do software ImageJ foi utilizada para extrair os contornos palpebrais direito e esquerdo de 75 sujeitos normais. A variabilidade interobservador de 29 contornos palpebrais do olho direito obtidos por dois observadores diferentes foi estimada pelo coeficiente de superposição de duas curvas e pela análise das diferenças das posições do pico do contorno. Análise de variância de dois fatores foi empregada para testar a média do coeficiente de superposição entre os contornos direito e esquerdo quanto ao sexo e segmento palpebral. A mesma análise foi utilizada para comparar a localização do pico do contorno dos olhos direito e esquerdo. Resultados: O coeficiente de superposição obtidos por observadores independentes variou ente 93,5% e 98,8% com média de 96,1% ± 1,6 DP. A diferença das médias da localização do pico do contorno palpebral foi de 0,02 mm. A simetria entre os contornos dos olhos direito e esquerdo não diferiu entre o sexo feminino e masculino e esteve na faixa de variabilidade do método para o coeficiente de superposição e localização do pico do contorno. Conclusões: O contorno da pálpebra superior é altamente simétrico. As linhas Bézier permitem uma rápida e prática quantificação do contorno palpebral com uma média de variabilidade interobservador de 3,9%.