Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Neuroimage ; 281: 120377, 2023 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-37714391

RESUMO

The Human Connectome Project (HCP)-style surface-based brain MRI analysis is a powerful technique that allows precise mapping of the cerebral cortex. However, the strength of its surface-based analysis has not yet been tested in the older population that often presents with white matter hyperintensities (WMHs) on T2-weighted (T2w) MRI (hypointensities on T1w MRI). We investigated T1-weighted (T1w) and T2w structural MRI in 43 healthy middle-aged to old participants. Juxtacortical WMHs were often misclassified by the default HCP pipeline as parts of the gray matter in T1w MRI, leading to incorrect estimation of the cortical surfaces and cortical metrics. To revert the adverse effects of juxtacortical WMHs, we incorporated the Brain Intensity AbNormality Classification Algorithm into the HCP pipeline (proposed pipeline). Blinded radiologists performed stereological quality control (QC) and found a decrease in the estimation errors in the proposed pipeline. The superior performance of the proposed pipeline was confirmed using an originally-developed automated surface QC based on a large database. Here we showed the detrimental effects of juxtacortical WMHs for estimating cortical surfaces and related metrics and proposed a possible solution for this problem. The present knowledge and methodology should help researchers identify adequate cortical surface biomarkers for aging and age-related neuropsychiatric disorders.


Assuntos
Encefalopatias , Leucoaraiose , Substância Branca , Pessoa de Meia-Idade , Humanos , Substância Branca/diagnóstico por imagem , Envelhecimento , Imageamento por Ressonância Magnética/métodos , Córtex Cerebral/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem
2.
J Digit Imaging ; 33(6): 1543-1553, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33025166

RESUMO

Temporal subtraction (TS) technique calculates a subtraction image between a pair of registered images acquired from the same patient at different times. Previous studies have shown that TS is effective for visualizing pathological changes over time; therefore, TS should be a useful tool for radiologists. However, artifacts caused by partial volume effects degrade the quality of thick-slice subtraction images, even with accurate image registration. Here, we propose a subtraction method for reducing artifacts in thick-slice images and discuss its implementation in high-speed processing. The proposed method is based on voxel matching, which reduces artifacts by considering gaps in discretized positions of two images in subtraction calculations. There are two different features between the proposed method and conventional voxel matching: (1) the size of a searching region to reduce artifacts is determined based on discretized position gaps between images and (2) the searching region is set on both images for symmetrical subtraction. The proposed method is implemented by adopting an accelerated subtraction calculation method that exploit the nature of liner interpolation for calculating the signal value at a point among discretized positions. We quantitatively evaluated the proposed method using synthetic data and qualitatively using clinical data interpreted by radiologists. The evaluation showed that the proposed method was superior to conventional methods. Moreover, the processing speed using the proposed method was almost unchanged from that of the conventional methods. The results indicate that the proposed method can improve the quality of subtraction images acquired from thick-slice images.


Assuntos
Tomografia Computadorizada por Raios X , Algoritmos , Artefatos , Humanos , Radiologistas , Técnica de Subtração
3.
Eur Radiol ; 29(12): 6439-6442, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31273458

RESUMO

OBJECTIVE: Temporal subtraction of CT (TS) images improves detection of newly developed bone metastases (BM). We sought to determine whether TS improves detection of BM by radiology residents as well. METHODS: We performed an observer study using a previously reported dataset, consisting of 60 oncology patients, each with previous and current CT images. TS images were calculated using in-house software. Four residents independently interpreted twice the 60 sets of CT images, without and with TS. They identified BM by marking suspicious lesions likely to be BM. Lesion-based sensitivity and number of false positives per patient were calculated. Figure-of-merit (FOM) was calculated. Detectability of BM, with and without TS, was compared between radiology residents and board-certified radiologists, as published previously. RESULTS: FOM of residents significantly improved by implementing TS (p value < 0.0001). Lesion-based sensitivity, false positives per patients, and FOM were 40.8%, 0.121, and 0.657, respectively, without TS, and 58.1%, 0.0958, and 0.796, respectively, with TS. These findings were comparable with the previously published values for board-certified radiologists without TS (58.0%, 0.19, and 0.758, respectively). CONCLUSION: The detectability of BM by residents improved markedly by implementing TS and reached that of board-certified radiologists without TS. KEY POINTS: • Detectability of bone metastases on CT by residents improved significantly when using temporal subtraction of CT (TS). • Detections by residents with TS and board-certified radiologists without TS were comparable. • TS is useful for residents as it is for board-certified radiologists.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Competência Clínica/estatística & dados numéricos , Interpretação de Imagem Assistida por Computador/métodos , Radiologia/educação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Humanos , Internato e Residência , Sensibilidade e Especificidade , Técnica de Subtração
4.
Eur Radiol ; 29(10): 5673-5681, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30888486

RESUMO

OBJECTIVES: To compare observer performance of detecting bone metastases between bone scintigraphy, including planar scan and single-photon emission computed tomography, and computed tomography (CT) temporal subtraction (TS). METHODS: Data on 60 patients with cancer who had undergone CT (previous and current) and bone scintigraphy were collected. Previous CT images were registered to the current ones by large deformation diffeomorphic metric mapping; the registered previous images were subtracted from the current ones to produce TS. Definitive diagnosis of bone metastases was determined by consensus between two radiologists. Twelve readers independently interpreted the following pairs of examinations: NM-pair, previous and current CTs and bone scintigraphy, and TS-pair, previous and current CTs and TS. The readers assigned likelihood levels to suspected bone metastases for diagnosis. Sensitivity, number of false positives per patient (FPP), and reading time for each pair of examinations were analysed for evaluating observer performance by performing the Wilcoxon signed-rank test. Figure-of-merit (FOM) was calculated using jackknife alternative free-response receiver operating characteristic analysis. RESULTS: The sensitivity of TS was significantly higher than that of bone scintigraphy (54.3% vs. 41.3%, p = 0.006). FPP with TS was significantly higher than that with bone scintigraphy (0.189 vs. 0.0722, p = 0.003). FOM of TS tended to be better than that of bone scintigraphy (0.742 vs. 0.691, p = 0.070). CONCLUSION: Sensitivity of TS in detecting bone metastasis was significantly higher than that of bone scintigraphy, but still limited to 54%. TS might be superior to bone scintigraphy for early detection of bone metastasis. KEY POINTS: • Computed tomography temporal subtraction was helpful in early detection of bone metastases. • Sensitivity for bone metastasis was higher for computed tomography temporal subtraction than for bone scintigraphy. • Figure-of-merit of computed tomography temporal subtraction was better than that of bone scintigraphy.


Assuntos
Neoplasias Ósseas/diagnóstico , Detecção Precoce de Câncer/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Metástase Neoplásica , Curva ROC
5.
Eur Radiol ; 29(2): 759-769, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30062525

RESUMO

OBJECTIVE: To assess whether temporal subtraction (TS) images of brain CT improve the detection of suspected brain infarctions. METHODS: Study protocols were approved by our institutional review board, and informed consent was waived because of the retrospective nature of this study. Forty-two sets of brain CT images of 41 patients, each consisting of a pair of brain CT images scanned at two time points (previous and current) between January 2011 and November 2016, were collected for an observer performance study. The 42 sets consisted of 23 cases with a total of 77 newly developed brain infarcts or hyperdense artery signs confirmed by two radiologists who referred to additional clinical information and 19 negative control cases. To create TS images, the previous images were registered to the current images by partly using a non-rigid registration algorithm and then subtracted. Fourteen radiologists independently interpreted the images to identify the lesions with and without TS images with an interval of over 4 weeks. A figure of merit (FOM) was calculated along with the jackknife alternative free-response receiver-operating characteristic analysis. Sensitivity, number of false positives per case (FPC) and reading time were analyzed by the Wilcoxon signed-rank test. RESULTS: The mean FOM increased from 0.528 to 0.737 with TS images (p < 0.0001). The mean sensitivity and FPC improved from 26.5% and 0.243 to 56.0% and 0.153 (p < 0.0001 and p = 0.239), respectively. The mean reading time was 173 s without TS and 170 s with TS (p = 0.925). CONCLUSION: The detectability of suspected brain infarctions was significantly improved with TS CT images. KEY POINTS: • Although it is established that MRI is superior to CT in the detection of strokes, the first choice of modality for suspected stroke patients is often CT. • An observer performance study with 14 radiologists was performed to evaluate whether temporal subtraction images derived from a non-rigid transformation algorithm can significantly improve the detectability of newly developed brain infarcts on CT. • Temporal subtraction images were shown to significantly improve the detectability of newly developed brain infarcts on CT.


Assuntos
Infarto Encefálico/diagnóstico por imagem , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estudos Retrospectivos , Sensibilidade e Especificidade
7.
Radiology ; 285(2): 629-639, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28678671

RESUMO

Purpose To determine the improvement of radiologist efficiency and performance in the detection of bone metastases at serial follow-up computed tomography (CT) by using a temporal subtraction (TS) technique based on an advanced nonrigid image registration algorithm. Materials and Methods This retrospective study was approved by the institutional review board, and informed consent was waived. CT image pairs (previous and current scans of the torso) in 60 patients with cancer (primary lesion location: prostate, n = 14; breast, n = 16; lung, n = 20; liver, n = 10) were included. These consisted of 30 positive cases with a total of 65 bone metastases depicted only on current images and confirmed by two radiologists who had access to additional imaging examinations and clinical courses and 30 matched negative control cases (no bone metastases). Previous CT images were semiautomatically registered to current CT images by the algorithm, and TS images were created. Seven radiologists independently interpreted CT image pairs to identify newly developed bone metastases without and with TS images with an interval of at least 30 days. Jackknife free-response receiver operating characteristics (JAFROC) analysis was conducted to assess observer performance. Reading time was recorded, and usefulness was evaluated with subjective scores of 1-5, with 5 being extremely useful and 1 being useless. Significance of these values was tested with the Wilcoxon signed-rank test. Results The subtraction images depicted various types of bone metastases (osteolytic, n = 28; osteoblastic, n = 26; mixed osteolytic and blastic, n = 11) as temporal changes. The average reading time was significantly reduced (384.3 vs 286.8 seconds; Wilcoxon signed rank test, P = .028). The average figure-of-merit value increased from 0.758 to 0.835; however, this difference was not significant (JAFROC analysis, P = .092). The subjective usefulness survey response showed a median score of 5 for use of the technique (range, 3-5). Conclusion TS images obtained from serial CT scans using nonrigid registration successfully depicted newly developed bone metastases and showed promise for their efficient detection. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/secundário , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Neoplasias da Mama/patologia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
9.
Heliyon ; 9(7): e18357, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37539101

RESUMO

Rationale and objectives: Macromolecules (MMs) affect the precision and accuracy of neurochemical quantification in magnetic resonance spectroscopy. A measured MM basis is increasingly used in LCModel analysis combined with a spline baseline, whose stiffness is controlled by a parameter named DKNTMN. The effects of measured MM basis and DKNTMN were investigated. Materials and methods: Twenty-six healthy subjects were prospectively enrolled and scanned twice using a short echo-time Stimulated Echo Acquisition Mode (STEAM) at 7-T. Using LCModel, analyses were conducted using the simulated MM basis (MMsim) with DKNTMN 0.15 and an MM basis measured inhouse (MMmeas) with DKNTMN of 0.15, 0.30, 0.60 and 1.00. Cramér-Rao lower bound (CRLB) and the concentrations of gamma-aminobutyric acid (GABA), glutamate and excitatory-inhibitory ratio (EIR), in addition to MMs were statistically analyzed. Measurement stability was evaluated using coefficient of variation (CV). Results: CRLBs of GABA were significantly lower when using MMsim than MMmeas; those of glutamate were 2-3. GABA concentrations were significantly higher in the analysis using MMsim than MMmeas where concentrations were significantly higher with DKNTMN of 0.15 or 0.30 than 0.60 or 1.00. Difference in glutamate concentration was not significant. EIRs showed the same difference as in GABA depending on the DKNTMN values. CVs between test-retest scans were relatively stable for glutamate but became larger as DKNTMN increased for GABA and EIR. Conclusion: Neurochemical quantification depends on the parameters of the basis sets used for fitting. Analysis using MMmeas with DKNTMN of 0.30 conformed best to previous studies and is recommended.

10.
Magn Reson Med Sci ; 21(4): 531-537, 2022 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34373430

RESUMO

After introduction of the first human 7 tesla (7T) system in 1999, 7T MR systems have been employed as one of the most advanced platforms for human MR research for more than 20 years. Currently, two 7T MR models are approved for clinical use in the U.S.A. The approval facilitated introduction of the 7T system, summing up to around 100 worldwide. The approval in Japan is much awaited. As a clinical MR scanner, the 7T MR system is drawing attention in terms of safety.Several large-sized studies on bioeffects have been reported for vertigo, dizziness, motion disturbances, nausea, and others. Such effects might also be found in MR workers and researchers. Frequency and severity of reported bioeffects will be presented and discussed, including their variances. The high resonance frequency and shorter RF wavelength of 7T increase the concern about the safety. Homogeneous RF pulse excitation is difficult even for the brain, and a multi-channel parallel transmit (pTx) system is considered mandatory. However, pTx may create a hot spot, which makes the estimation of specific absorption rate (SAR) to be difficult. The stronger magnetic field of 7T causes a large force of displacement and heating on metallic implants or devices, and the scan of patients with them should not be conducted at 7T. However, there are some opinions that such patients might be scanned even at 7T, if certain criteria are met. This article provides a brief review on the effect of the static magnetic field on humans (MR subjects, workers, and researchers) and neurons, in addition to scan sound, SAR, and metal implants and devices. Understanding and avoiding adverse effects will contribute to the reduction in safety risks and the prevention of incidents.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/efeitos adversos , Imagens de Fantasmas
11.
Quant Imaging Med Surg ; 12(6): 3406-3435, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35655840

RESUMO

Neuroimaging using the 7-Tesla (7T) human magnetic resonance (MR) system is rapidly gaining popularity after being approved for clinical use in the European Union and the USA. This trend is the same for functional MR imaging (MRI). The primary advantages of 7T over lower magnetic fields are its higher signal-to-noise and contrast-to-noise ratios, which provide high-resolution acquisitions and better contrast, making it easier to detect lesions and structural changes in brain disorders. Another advantage is the capability to measure a greater number of neurochemicals by virtue of the increased spectral resolution. Many structural and functional studies using 7T have been conducted to visualize details in the white matter and layers of the cortex and hippocampus, the subnucleus or regions of the putamen, the globus pallidus, thalamus and substantia nigra, and in small structures, such as the subthalamic nucleus, habenula, perforating arteries, and the perivascular space, that are difficult to observe at lower magnetic field strengths. The target disorders for 7T neuroimaging range from tumoral diseases to vascular, neurodegenerative, and psychiatric disorders, including Alzheimer's disease, Parkinson's disease, multiple sclerosis, epilepsy, major depressive disorder, and schizophrenia. MR spectroscopy has also been used for research because of its increased chemical shift that separates overlapping peaks and resolves neurochemicals more effectively at 7T than a lower magnetic field. This paper presents a narrative review of these topics and an illustrative presentation of images obtained at 7T. We expect 7T neuroimaging to provide a new imaging biomarker of various brain disorders.

12.
Sci Rep ; 11(1): 18422, 2021 09 16.
Artigo em Inglês | MEDLINE | ID: mdl-34531429

RESUMO

To determine whether temporal subtraction (TS) CT obtained with non-rigid image registration improves detection of various bone metastases during serial clinical follow-up examinations by numerous radiologists. Six board-certified radiologists retrospectively scrutinized CT images for patients with history of malignancy sequentially. These radiologists selected 50 positive and 50 negative subjects with and without bone metastases, respectively. Furthermore, for each subject, they selected a pair of previous and current CT images satisfying predefined criteria by consensus. Previous images were non-rigidly transformed to match current images and subtracted from current images to automatically generate TS images. Subsequently, 18 radiologists independently interpreted the 100 CT image pairs to identify bone metastases, both without and with TS images, with each interpretation separated from the other by an interval of at least 30 days. Jackknife free-response receiver operating characteristics (JAFROC) analysis was conducted to assess observer performance. Compared with interpretation without TS images, interpretation with TS images was associated with a significantly higher mean figure of merit (0.710 vs. 0.658; JAFROC analysis, P = 0.0027). Mean sensitivity at lesion-based was significantly higher for interpretation with TS compared with that without TS (46.1% vs. 33.9%; P = 0.003). Mean false positive count per subject was also significantly higher for interpretation with TS than for that without TS (0.28 vs. 0.15; P < 0.001). At the subject-based, mean sensitivity was significantly higher for interpretation with TS images than that without TS images (73.2% vs. 65.4%; P = 0.003). There was no significant difference in mean specificity (0.93 vs. 0.95; P = 0.083). TS significantly improved overall performance in the detection of various bone metastases.


Assuntos
Neoplasias Ósseas/tratamento farmacológico , Tomografia Computadorizada por Raios X/normas , Idoso , Idoso de 80 Anos ou mais , Neoplasias Ósseas/secundário , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Radiologistas/estatística & dados numéricos , Sensibilidade e Especificidade , Software , Tomografia Computadorizada por Raios X/métodos
13.
Acad Radiol ; 27(3): e45-e54, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31147237

RESUMO

RATIONALE AND OBJECTIVES: The purpose of this study was to validate a Bayesian statistical model of item response theory (IRT). IRT was used to evaluate a new modality (temporal subtraction, TS) in observer studies of radiologists, compared with a conventional modality (computed tomography). MATERIALS AND METHODS: From previously published papers, we obtained two datasets of clinical observer studies of radiologists. Those studies used a multi-reader and multi-case paradigm to evaluate radiologists' detection abilities, primarily to determine if TS could enhance the detectability of bone metastasis or brain infarctions. We applied IRT to these studies' datasets using Stan software. Before applying IRT, the radiologists' responses were recorded as binaries for each case (1 = correct, 0 = incorrect). Effect of TS on detectability was evaluated by using our IRT model and calculating the 95% credible interval of the effect. RESULTS: The mean, median, and 95% credible interval of the effect of TS were 0.913, 0.885, and 0.243-1.745 for the bone metastasis detection, and 2.524, 2.50, and 1.827-3.310, for the brain infarction detection. For both detection studies, the 95% credible intervals of the effect of TS did not include zero, indicating that TS significantly improved diagnostic ability. CONCLUSION: Judgments based on the present study results were compatible with the two previous studies. Our study results demonstrated that the Bayesian statistical model of IRT could judge a new modality's usefulness.


Assuntos
Técnica de Subtração , Tomografia Computadorizada por Raios X , Teorema de Bayes , Humanos , Modelos Estatísticos , Variações Dependentes do Observador , Radiologistas
14.
Comput Methods Programs Biomed ; 196: 105711, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32858281

RESUMO

BACKGROUND AND OBJECTIVE: Currently, it is challenging to detect acute ischemic stroke (AIS)-related changes on computed tomography (CT) images. Therefore, we aimed to develop and evaluate an automatic AIS detection system involving a two-stage deep learning model. METHODS: We included 238 cases from two different institutions. AIS-related findings were annotated on each of the 238 sets of head CT images by referring to head magnetic resonance imaging (MRI) images in which an MRI examination was performed within 24 h following the CT scan. These 238 annotated cases were divided into a training set including 189 cases and test set including 49 cases. Subsequently, a two-stage deep learning detection model was constructed from the training set using the You Only Look Once v3 model and Visual Geometry Group 16 classification model. Then, the two-stage model performed the AIS detection process in the test set. To assess the detection model's results, a board-certified radiologist also evaluated the test set head CT images with and without the aid of the detection model. The sensitivity of AIS detection and number of false positives were calculated for the evaluation of the test set detection results. The sensitivity of the radiologist with and without the software detection results was compared using the McNemar test. A p-value of less than 0.05 was considered statistically significant. RESULTS: For the two-stage model and radiologist without and with the use of the software results, the sensitivity was 37.3%, 33.3%, and 41.3%, respectively, and the number of false positives per one case was 1.265, 0.327, and 0.388, respectively. On using the two-stage detection model's results, the board-certified radiologist's detection sensitivity significantly improved (p-value = 0.0313). CONCLUSIONS: Our detection system involving the two-stage deep learning model significantly improved the radiologist's sensitivity in AIS detection.


Assuntos
Isquemia Encefálica , Aprendizado Profundo , AVC Isquêmico , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X
15.
Sci Rep ; 9(1): 12246, 2019 08 22.
Artigo em Inglês | MEDLINE | ID: mdl-31439874

RESUMO

Diffusion tensor imaging (DTI) and neurite orientation dispersion and density imaging (NODDI) are widely used models to infer microstructural features in the brain from diffusion-weighted MRI. Several studies have recently applied both models to increase sensitivity to biological changes, however, it remains uncertain how these measures are associated. Here we show that cortical distributions of DTI and NODDI are associated depending on the choice of b-value, a factor reflecting strength of diffusion weighting gradient. We analyzed a combination of high, intermediate and low b-value data of multi-shell diffusion-weighted MRI (dMRI) in healthy 456 subjects of the Human Connectome Project using NODDI, DTI and a mathematical conversion from DTI to NODDI. Cortical distributions of DTI and DTI-derived NODDI metrics were remarkably associated with those in NODDI, particularly when applied highly diffusion-weighted data (b-value = 3000 sec/mm2). This was supported by simulation analysis, which revealed that DTI-derived parameters with lower b-value datasets suffered from errors due to heterogeneity of cerebrospinal fluid fraction and partial volume. These findings suggest that high b-value DTI redundantly parallels with NODDI-based cortical neurite measures, but the conventional low b-value DTI is hard to reasonably characterize cortical microarchitecture.


Assuntos
Substância Cinzenta/fisiologia , Neuritos/fisiologia , Adulto , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão , Feminino , Substância Cinzenta/diagnóstico por imagem , Humanos , Masculino , Neuritos/química , Adulto Jovem
17.
Magn Reson Imaging ; 43: 42-47, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28688951

RESUMO

PURPOSE: To evaluate images of non-contrast-enhanced 3D MR portography within a breath-hold (BH) using compressed sensing (CS) compared to standard respiratory-triggered (RT) sequences. MATERIALS AND METHODS: Fifty-nine healthy volunteers underwent MR portography using two sequences of balanced steady-state free-precession (bSSFP) with time-spatial labeling inversion pulses (Time-SLIP): BH bSSFP-CS and RT bSSFP. Two radiologists independently scored the diagnostic acceptability to delineate the portal branches (MPV: main portal vein; RPV: right portal vein; LPV: left portal vein; RPPV: right posterior portal vein; and P4 and P8: portal branch of segment 4 and segment 8, respectively) and the overall image quality on a four-point scale. We assessed noninferiority of BH bSSFP-CS to RT bSSFP. For quantitative analysis, vessel-to-liver contrast (Cv-l) was calculated in MPV, RPV and LPV. RESULTS: BH bSSFP sequence was successfully performed with a 30-second acquisition time. The diagnostic acceptability scores of BH bSSFP-CS compared with RT bSSFP were statistically noninferior: MPV (95% CI for score difference of Reader 1 and Reader 2, respectively: [-0.16, 0.06], [-0.05, 0.02]), RPV ([-0.00, 0.11], [-0.01, 0.08]), LPV ([-0.03, 0.10], [-0.10, 0.03]), RPPV ([-0.03, 0.10], [-0.05, 0.05]), P4 ([-0.13, 0.34], [-0.28, 0.21]) and P8 ([-0.21, 0.11], [-0.25, -0.02]). However, the overall image quality of BH bSSFP-CS did not show noninferiority ([-0.61, -0.24], [-0.54, -0.17]). Cv-l values were significantly lower in BH bSSFP-CS (P<0.001). CONCLUSION: CS enabled non-contrast-enhanced 3D bSSFP MR portography to be performed within a BH while maintaining noninferior diagnostic acceptability compared to standard RT bSSFP MR portography.


Assuntos
Suspensão da Respiração , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Portografia , Aceleração , Adulto , Meios de Contraste , Coleta de Dados , Compressão de Dados , Feminino , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Fígado , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Veia Porta/diagnóstico por imagem , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
18.
PLoS One ; 11(1): e0146548, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26744843

RESUMO

In Compressed Sensing (CS) of MRI, optimization of the regularization parameters is not a trivial task. We aimed to establish a method that could determine the optimal weights for regularization parameters in CS of time-of-flight MR angiography (TOF-MRA) by comparing various image metrics with radiologists' visual evaluation. TOF-MRA of a healthy volunteer was scanned using a 3T-MR system. Images were reconstructed by CS from retrospectively under-sampled data by varying the weights for the L1 norm of wavelet coefficients and that of total variation. The reconstructed images were evaluated both quantitatively by statistical image metrics including structural similarity (SSIM), scale invariant feature transform (SIFT) and contrast-to-noise ratio (CNR), and qualitatively by radiologists' scoring. The results of quantitative metrics and qualitative scorings were compared. SSIM and SIFT in conjunction with brain masks and CNR of artery-to-parenchyma correlated very well with radiologists' visual evaluation. By carefully selecting a region to measure, we have shown that statistical image metrics can reflect radiologists' visual evaluation, thus enabling an appropriate optimization of regularization parameters for CS.


Assuntos
Angiografia por Ressonância Magnética/métodos , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/fisiologia , Tomada de Decisão Clínica , Compressão de Dados , Médicos Hospitalares , Humanos , Interpretação de Imagem Assistida por Computador , Reconhecimento Automatizado de Padrão , Reconhecimento Visual de Modelos , Melhoria de Qualidade , Intensificação de Imagem Radiográfica , Radiologia , Razão Sinal-Ruído
19.
Radiol Phys Technol ; 6(2): 486-91, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23728709

RESUMO

We evaluated the degree of inhomogeneities of fat suppression using the fully automated three-dimensional breast shimming technique (Image Based-Smart: IB-Smart) and manual setting of a rectangular parallelepiped shim (volume shimming) in MR mammography. Information on breast shape was collected from 9 patients whose images were insufficiently fat-suppressed. A breast phantom made of a thermoplastic sheet was used. Shimming of the magnetic field was done with IB-Smart and various dimensions of volume shims: the anterior to posterior/right to left/head to foot directions were set to 75-150/150-350/50-150 mm. The volumes of inhomogeneously suppressed fat were measured. The calculated volume with inhomogeneous fat suppression with use of IB-Smart was 13.3 × 10(4) mm(3). The smallest volume of inhomogeneous fat suppression with volume shimming was 5.4 × 10(4) mm(3) when the anterior-posterior/right-left/head-foot directions were set to 75/350/50 mm. Our results show that using optimized dimensions of volume shims enables better fat suppression than does IB-Smart.


Assuntos
Tecido Adiposo/anatomia & histologia , Tecido Adiposo/diagnóstico por imagem , Mama/anatomia & histologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Mamografia , Imagens de Fantasmas , Feminino , Humanos
20.
Cardiovasc Intervent Radiol ; 33(6): 1257-61, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19902296

RESUMO

We report a 64-year-old woman with duodenal varices who underwent balloon-occluded retrograde transvenous obliteration (B-RTO) complicated by intraprocedural variceal rupture. The patient developed shivering and a fever higher than 40°C 3 days after the B-RTO procedure. A blood culture grew Entereobacter cloacoe. This case represents a rare septic complication of B-RTO for duodenal varices.


Assuntos
Oclusão com Balão/efeitos adversos , Duodenopatias/terapia , Enterobacter cloacae/isolamento & purificação , Infecções por Enterobacteriaceae/etiologia , Hemorragia Gastrointestinal/terapia , Varizes/terapia , Oclusão com Balão/métodos , Meios de Contraste , Duodenopatias/diagnóstico por imagem , Infecções por Enterobacteriaceae/microbiologia , Feminino , Fluoroscopia , Hemorragia Gastrointestinal/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Pessoa de Meia-Idade , Flebografia , Tomografia Computadorizada por Raios X , Varizes/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA