Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Diabet Med ; 40(3): e14952, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36054221

RESUMO

AIM: To explore if novel non-invasive diagnostic technologies identify early small nerve fibre and retinal neurovascular pathology in prediabetes. METHODS: Participants with normoglycaemia, prediabetes or type 2 diabetes underwent an exploratory cross-sectional analysis with optical coherence tomography angiography (OCT-A), handheld electroretinography (ERG), corneal confocal microscopy (CCM) and evaluation of electrochemical skin conductance (ESC). RESULTS: Seventy-five participants with normoglycaemia (n = 20), prediabetes (n = 29) and type 2 diabetes (n = 26) were studied. Compared with normoglycaemia, mean peak ERG amplitudes of retinal responses at low (16-Td·s: 4.05 µV, 95% confidence interval [95% CI] 0.96-7.13) and high (32-Td·s: 5·20 µV, 95% CI 1.54-8.86) retinal illuminance were lower in prediabetes, as were OCT-A parafoveal vessel densities in superficial (0.051 pixels/mm2 , 95% CI 0.005-0.095) and deep (0.048 pixels/mm2 , 95% CI 0.003-0.093) retinal layers. There were no differences in CCM or ESC measurements between these two groups. Correlations between HbA1c and peak ERG amplitude at 32-Td·s (r = -0.256, p = 0.028), implicit time at 32-Td·s (r = 0.422, p < 0.001) and 16-Td·s (r = 0.327, p = 0.005), OCT parafoveal vessel density in the superficial (r = -0.238, p = 0.049) and deep (r = -0.3, p = 0.017) retinal layers, corneal nerve fibre length (CNFL) (r = -0.293, p = 0.017), and ESC-hands (r = -0.244, p = 0.035) were observed. HOMA-IR was a predictor of CNFD (ß = -0.94, 95% CI -1.66 to -0.21, p = 0.012) and CNBD (ß = -5.02, 95% CI -10.01 to -0.05, p = 0.048). CONCLUSIONS: The glucose threshold for the diagnosis of diabetes is based on emergent retinopathy on fundus examination. We show that both abnormal retinal neurovascular structure (OCT-A) and function (ERG) may precede retinopathy in prediabetes, which require confirmation in larger, adequately powered studies.


Assuntos
Diabetes Mellitus Tipo 2 , Estado Pré-Diabético , Doenças Retinianas , Humanos , Estado Pré-Diabético/diagnóstico , Diabetes Mellitus Tipo 2/diagnóstico , Estudos Transversais , Retina
2.
Ther Adv Neurol Disord ; 16: 17562864221118731, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36776530

RESUMO

Background: Resourceful endpoints of axonal loss are needed to predict the course of multiple sclerosis (MS). Corneal confocal microscopy (CCM) can detect axonal loss in patients with clinically isolated syndrome and established MS, which relates to neurological disability. Objective: To assess corneal axonal loss over time in relation to retinal atrophy, and neurological and radiological abnormalities in MS. Methods: Patients with relapsing-remitting (RRMS) (n = 68) or secondary progressive MS (SPMS) (n = 15) underwent CCM and optical coherence tomography. Corneal nerve fibre density (CNFD-fibres/mm2), corneal nerve branch density (CNBD-branches/mm2), corneal nerve fibre length (CNFL-mm/mm2) and retinal nerve fibre layer (RNFL-µm) thickness were quantified along with neurological and radiological assessments at baseline and after 2 years of follow-up. Age-matched, healthy controls (n = 20) were also assessed. Results: In patients with RRMS compared with controls at baseline, CNFD (p = 0.004) and RNFL thickness (p < 0.001) were lower, and CNBD (p = 0.003) was higher. In patients with SPMS compared with controls, CNFD (p < 0.001), CNFL (p = 0.04) and RNFL thickness (p < 0.001) were lower. For identifying RRMS, CNBD had the highest area under the receiver operating characteristic (AUROC) curve (0.99); and for SPMS, CNFD had the highest AUROC (0.95). At follow-up, there was a further significant decrease in CNFD (p = 0.04), CNBD (p = 0.001), CNFL (p = 0.008) and RNFL (p = 0.002) in RRMS; in CNFD (p = 0.04) and CNBD (p = 0.002) in SPMS; and in CNBD (p = 0.01) in SPMS compared with RRMS. Follow-up corneal nerve loss was greater in patients with new enhancing lesions and optic neuritis history. Conclusion: Progressive corneal and retinal axonal loss was identified in patients with MS, especially those with more active disease. CCM may serve as an imaging biomarker of axonal loss in MS.

3.
Ther Adv Neurol Disord ; 16: 17562864231204974, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37915502

RESUMO

Background: Corneal immune cells (ICs) are antigen-presenting cells that are known to increase ocular and systemic inflammatory conditions. Objective: We aimed to assess longitudinal changes in corneal IC in patients with multiple sclerosis (MS) and relation to disability and ongoing treatment. Design: Prospective observational study conducted between September 2016 and February 2020. Methods: Patients with relapsing-remitting MS (RRMS) (n = 45) or secondary progressive MS (SPMS) (n = 15) underwent corneal confocal microscopy (CCM) at baseline and 2-year follow-up for estimation of corneal IC density [dendritic cells with (DCF) (cells/mm2) or without nerve fiber contact (DCP); and non-dendritic cells with (NCF) or without nerve fiber contact (NCP)]. Optical coherence tomography, neuroimaging, and disability assessments were additionally performed. Healthy controls (n = 20) were assessed at baseline. Results: In both RRMS and SPMS compared to controls, DCP (p < 0.001 and p < 0.001, respectively) and DCF (p < 0.001 and p = 0.005) were higher and NCF (p = 0.007 and p = 0.02) was lower at baseline. DCP showed excellent performance in identifying patients with MS (sensitivity/specificity = 0.88/0.90) followed by DCF (0.80/0.75) and NCF (0.80/0.85). At follow-up compared to baseline, DCP (p = 0.01) was significantly reduced, and NCP (p = 0.004) and NCF (p = 0.04) were increased. Subgroup analysis showed that baseline NCP and NCF were significantly higher (p = 0.04-0.05) in patients who switched disease-modifying treatment, and baseline NCP (p = 0.05) was higher in patients on interferon. Conclusion: Baseline and change in corneal IC were related to axonal degeneration and treatment status. Evaluation of corneal IC using CCM may allow an assessment of ongoing inflammation, disease progression, and the effect of treatment in MS.

4.
Ann Clin Transl Neurol ; 6(4): 689-697, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31019993

RESUMO

OBJECTIVES: Corneal confocal microscopy (CCM) is a noninvasive ophthalmic technique that identifies corneal nerve degeneration in a range of peripheral neuropathies and in patients with multiple sclerosis, Parkinson's disease, and amyotrophic lateral sclerosis. We sought to determine whether there is any association of corneal nerve fiber measures with cognitive function and functional independence in patients with MCI and dementia. METHODS: In this study, 76 nondiabetic participants with MCI (n = 30), dementia (n = 26), and healthy age-matched controls (n = 20) underwent assessment of cognitive and physical function and CCM. RESULTS: There was a progressive reduction in corneal nerve fiber density (CNFD), branch density (CNBD), and fiber length (CNFL) (P < 0.0001) in patients with MCI and dementia compared to healthy controls. Adjusted for confounders, all three corneal nerve fiber measures were significantly associated with cognitive function (P < 0.05) and functional independence (P < 0.01) in MCI and dementia. The area under the ROC curve to distinguish MCI with CNFD, CNBD, and CNFL was 69.1%, 73.2%, and 73.0% and for dementia it was 84.8%, 84.2%, and 86.2%, respectively. INTERPRETATION: CCM demonstrates corneal nerve fiber loss, which is associated with a decline in cognitive function and functional independence in patients with MCI and dementia.


Assuntos
Cognição/fisiologia , Córnea/inervação , Demência/patologia , Fibras Nervosas/patologia , Idoso , Demência/etiologia , Neuropatias Diabéticas/patologia , Neuropatias Diabéticas/fisiopatologia , Feminino , Humanos , Masculino , Microscopia Confocal/métodos , Pessoa de Meia-Idade , Doença de Parkinson/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA