Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
1.
J Prosthodont ; 33(4): 358-366, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37114526

RESUMO

PURPOSE: To compare the fracture resistance and failure modes of anterior cantilever resin-bonded fixed partial dentures (RBFPDs) fabricated from high translucency zirconia with different intaglio surface treatments. MATERIALS AND METHODS: Sound-extracted canines (N = 50) were randomly divided into five groups (n = 10) to be restored with high translucency zirconia RBFBDs of different intaglio surface treatments. The RBFPD was designed using exocad software and fabricated using a CAM milling machine. The RBFPDs were treated differently: abrasion with 50 µm alumina particles (Group 1); abrasion with 30 µm silica-coated alumina particles (Group 2); abrasion with silica-coated alumina particles (30 µm) and silane application (Group 3); abrasion with silica-coated alumina particles (30 µm) and 10-methacryloyloxydecyl dihydrogen phosphate (10-MDP) primer application (Group 4); abrasion with silica-coated alumina particles (30 µm) and silane, and 10-MDP primer application. All RBFPDs were cemented using dual-cured resin cement. The RBFPDs underwent 6000 thermal cycles with distilled water at 5/55°C for 2 min per cycle and then mechanical cyclic loading with 1200,000 cycles of 50 N at a 1.7 Hz frequency at an angle of 135° to the abutment's long axis. Then, RBFPDs were loaded to fracture using a universal testing machine at 1 mm/min. Maximum fracture forces and failure modes were recorded. Fractured specimens and uncemented specimens were examined using a scanning electron microscope. Data was analyzed using ANOVA and Games-Howell post hoc tests at p < 0.05. RESULTS: Mean fracture load results showed a statistically significant difference between the research groups (p < 0.0001) and it ranged from 69.78 to 584 N. Group 4 exhibited the highest fracture load mean (p < 0.0001) which was significantly different from all other groups. Group 2 recorded a significantly higher fracture load mean than Group 3 (p = 0.029). Three modes of failure were observed: prosthesis debonding, prosthesis fracture, and abutment fracture. CONCLUSIONS: Abrasion of zirconia surface with 30 µm silica-coated alumina particles and application of 10-MDP primer yielded the highest mean fracture loads of monolithic high translucency zirconia RBFPD. The mode of fracture of the RBFPDs was influenced by the type of surface treatments.


Assuntos
Colagem Dentária , Prótese Adesiva , Metacrilatos , Resistência à Flexão , Silanos , Teste de Materiais , Cimentos de Resina , Zircônio , Dióxido de Silício , Óxido de Alumínio , Propriedades de Superfície , Análise do Estresse Dentário/métodos
2.
J Prosthodont ; 28(7): 818-825, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31066483

RESUMO

PURPOSE: To evaluate surface roughness and topography of different zirconia-based restorations at various steps of finishing and polishing. MATERIALS AND METHODS: Seventy-five zirconia discs were fabricated and divided into 3 layered and 2 monolithic groups: layered conventional (VM9; Vita), layered pressed (PM9; Vita), layered digital (TriLuxe Forte; Vita), opaque monolithic (Ceramill Zi; Amann Girrbach), and translucent monolithic (Zolid FX; Amann Girrbach). Surface roughness testing (Ra, Rz) and scanning electron microscopy were performed at the glazed, unglazed, finished, polished, super-polished, and super-polished with diamond paste steps. One-way ANOVA and Tukey tests were used for statistical analysis. RESULTS: There were significant differences in all groups among the different steps (p < 0.001, F = 77.67 for layered conventional; p < 0.001, F = 133.90 for layered pressed; p < 0.001, F = 47.94 for layered digital; p < 0.001, F = 48.05 for zirconia opaque; p < 0.001, F = 43.91 for zirconia translucent). For the layered groups, glazed stage was significantly different from all other steps (p < 0.001). For the layered conventional and digital groups, polishing using diamond paste was not significantly different from the polished and super-polished steps (p = 0.448, p = 0.153), while for the layered pressed group, polishing using diamond paste was not significantly different from the super polished step (p = 0.815). For monolithic groups, there were no significant differences between the polished and super-polished steps (p = 0.957 for zirconia opaque, p = 1.00 for zirconia translucent). Both the diamond paste and super-polished steps showed no significant differences (p = 0.620, p = 0.550) from the glazed surface in the opaque zirconia group. CONCLUSIONS: Surface roughness of monolithic and layered zirconia was improved by polishing; however, only opaque zirconia reached the level of surface roughness of the glazed stage. Type of buildup affected the surface roughness of adjusted ceramics, with monolithic zirconia showing lower surface roughness than layered zirconia. Polishing with diamond paste provided no significant improvement in the surface roughness of monolithic or layered zirconia.


Assuntos
Polimento Dentário , Zircônio , Porcelana Dentária , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
3.
J Prosthodont ; 27(3): 250-259, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29067778

RESUMO

PURPOSE: To report a comprehensive description of dental implant system selection practices among dentists practicing implantology worldwide. MATERIALS AND METHODS: An online questionnaire was designed and sent to members of 15 dental implant organizations. The survey questions addressed: dental implant system selection criteria, implant design variables, dentists' perspective to implant quality stamps, and dentists' satisfaction with their implant system(s). Responses were compiled and analyzed to determine correlation of responses using the chi-squared test (level of significance α ≤ 0.05). RESULTS: Out of 4264 invitations sent, a total of 2001 (response rate = 46.9%) dentists participated in the survey. Approximately half of survey respondents (48.7%) were general dentists. More than two-thirds of the survey respondents (72.5%) were performing both the surgical and prosthetic implant phases. Implant-abutment connections were the most important dental implant system selection criterion (84.7%), followed by scientific evidence available on the implant system (82.8%), and simplicity of prosthetic steps (81.4%). Patient preferences (19.8%) were rated as the least important aspect. Sandblasted large gritted acid etched implant surfaces (SLA) were the most commonly used implant surfaces (75.8%); fluoride coated surfaces were the least commonly used (15.4%). CONCLUSION: According to the results of this survey, most survey respondents practiced both surgical and prosthetic phases of dental implantology. The majority of survey respondents agreed on the importance of implant-abutment connections, scientific evidence available on implant systems, and simplicity of prosthetic steps when selecting implant systems.


Assuntos
Tomada de Decisão Clínica , Implantes Dentários , Padrões de Prática Odontológica , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
J Prosthodont ; 27(4): 347-354, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27159089

RESUMO

PURPOSE: To examine the effects of the veneering technique on the shade reproducibility of zirconia-based crowns. MATERIALS AND METHODS: An artificial tooth was prepared with a 1.2 mm heavy chamfer finish line and 8° taper. The prepared tooth was scanned using CAD/CAM technology to fabricate 45 cobalt chromium (CoCr) testing dies. One CoCr die was scanned, and 45 zirconia copings were milled and devided according to the veneering technique into 3 groups of 15 specimens each: layering veneering (LV) using Vita Vm9, overpressing veneering (OV) using Vita Pm9, and digital veneering (DV) using Vita Triluxe forte. All veneering layers had the same shade (A2). The specimens were cemented onto the testing dies using glass inomer cement. A spectrophotometer was used to measure the shade coordinates (L, C, h, a, b) for a Vita A2 shade tab and for each specimen. Both the CIE Lab (ΔEab ) and the CIE DE2000 (ΔE00 ) color difference formulas were applied to compare the shade tab and the study groups. One-way ANOVA and multiple comparison Bonferroni tests were applied for statistical analysis of the results. RESULTS: Means and standard deviations (SDs) of ΔEab were 2.3 ± 1.3 for LV, 3.5 ± 0.8 for OV, and 4.0 ± 0.7 for DV. Means and SDs of ΔE00 were 1.4 ± 0.8 for LV, 2.1 ± 0.5 for OV, and 3.1 ± 0.4 for DV. ΔEab of LV group was significantly lower (p < 0.05) than both OV and DV groups, whereas the difference in ΔEab between OV and DV groups was not significant (p = 0.39). The differences in ΔE00 between all groups were significant (p < 0.05). CONCLUSIONS: LV group was superior to other groups in terms of shade reproducibility. The ΔEab and the ΔE00 values of LV and OV groups were within clinically acceptable ranges; however, the ΔEab and the ΔE00 values of group DV were beyond the clinically acceptable ranges. The ΔE00 formula demonstrated a statistically significant difference between OV and the DV groups, while the ΔEab formula did not. The zirconia veneering technique had a significant influence on the shade reproducibility of zirconia-based crowns.


Assuntos
Coroas , Materiais Dentários , Facetas Dentárias , Pigmentação em Prótese/métodos , Zircônio , Planejamento de Prótese Dentária , Teste de Materiais , Projetos Piloto
5.
J Prosthodont ; 27(7): 651-658, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27163490

RESUMO

PURPOSE: To examine the effects of the veneering technique on the fracture resistance of zirconia-based crowns. MATERIALS AND METHODS: An artificial tooth was prepared with a 1.2 mm heavy chamfer finish line and 8° taper. The prepared tooth was scanned using CAD/CAM technology to fabricate 45 cobalt chromium (CoCr) testing dies. One CoCr die was scanned, and 45 zirconia copings were milled and divided according to the veneering technique into three groups of 15 specimens each: layering veneering (LV) using Vita Vm9, overpressing veneering (OV) using Vita Pm9, and digital veneering (DV) using Vita Triluxe forte. The crowns were cemented onto the testing dies using glass ionomer cement. The specimens were thermocycled (3000 cycles, 5° to 55°) then statically loaded (3.7 mm ball, 0.5 mm/min crosshead speed) until failure. Failed crowns were inspected using a magnifier, and failure patterns were identified. One-way ANOVA and multiple comparison Bonferroni tests were applied for statistical analysis of the results. RESULTS: Means and standard deviations of failure loads were 1200 ± 306 N for the LV group, 857 ± 188 N for the OV group, and 638 ± 194 N for the DV group. The differences in failure loads were statistically significant between all groups (p < 0.05). Failure mode was predominantly cohesive for LV and OV groups, whereas it was predominantly adhesive for the DV group. CONCLUSIONS: The LV group was superior to other groups in terms of fracture resistance, while the DV group was inferior to the other groups in the same aspect.


Assuntos
Coroas , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Facetas Dentárias , Zircônio/química , Ligas de Cromo/química , Desenho Assistido por Computador , Análise do Estresse Dentário
6.
J Esthet Restor Dent ; 28 Suppl 1: S56-67, 2016 03.
Artigo em Inglês | MEDLINE | ID: mdl-25640703

RESUMO

PURPOSE: To determine the effect of type of base metal alloy, opaque thickness, and repeated firing on color of metal ceramic restorations. MATERIALS AND METHODS: Four nickel chromium and four cobalt chromium were selected with one noble alloy as a control. Ten discs (16 mm 0.5 mm) were prepared for each group. Color of specimens were measured using a spectrophotometer and were calculated using CIEDE2000 formula (ΔL', ΔC', ΔH', ΔE') between experimental groups and control at six stages of porcelain constructions: opaque 0.1 and 0.3 mm, dentine, enamel, glaze, and three times repeated firing. Shade A3 was used. One-way analysis of variance and Bonferroni multiple test were performed (α = 0.05). RESULTS: Alloy type and stage showed statistical significance on total color and color parameter differences from the control and there was significant interaction between them (p < .05). Nidour alloy was the closest to control. Increase in ΔC' and a decrease in ΔH' and in a* and b* was the commonest in comparison with the control. However, ΔE' was below acceptability threshold for all alloys at all stages. CONCLUSION: Despite the statistical significance, base metal alloys performed as good as noble metal control. Neither opaque thickness, nor repeated firing affected color variations from the control group. There was no obvious trend in the behavior of metal alloys at all stages. However, increase in chroma and a decrease in hue, with green blue shift, was the most common. CLINICAL SIGNIFICANCE: Records of the effects of eight commonly used base metal alloys on the color of final shade of the metal-ceramic restorations, at various stages of ceramic buildup, have considerable value. (J Esthet Restor Dent 28:S56-S67, 2016).


Assuntos
Restauração Dentária Permanente , Ligas Metalo-Cerâmicas , Espectrofotometria , Cor , Ligas Dentárias , Porcelana Dentária , Teste de Materiais
7.
J Craniofac Surg ; 26(6): e502-5, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26221855

RESUMO

Implant-retained auricular prostheses are a successful prosthetic treatment option for patients who are missing their ear(s) due to trauma, oncology, or birth defects. The prosthetic ear is aesthetically pleasing, composed of natural looking anatomical contours, shape, and texture along with good color that blends with surrounding existing skin. These outcomes can be optimized by the integration of digital technologies in the construction process. This report describes a sequential process of reconstructing a missing left ear by digital technologies. Two implants were planned for placement in the left mastoid region utilizing specialist biomedical software (Materialise, Belgium). The implant positions were determined underneath the thickest portion (of anti-helix area) left ear that is virtually simulated by means of mirror imaging of the right ear. A surgical stent recording the implant positions was constructed and used in implant fixtures placement. Implants were left for eight weeks, after which they were loaded with abutments and an irreversible silicone impression was taken to record their positions. The right existing ear was virtually segmented using the patient CT scan and then mirror imaged to produce a left ear, which was then printed using 3D printer (Z Corp, USA). The left ear was then duplicated in wax which was fitted over the defect side. Then, it was conventionally flasked. Skin color was digitalized using spectromatch skin color system (London, UK). The resultant silicone color was mixed as prescribed and then packed into the mold. The silicone was cured conventionally. Ear was trimmed and fitted and there was no need for any extrinsic coloring. The prosthetic ear was an exact match to the existing right ear in shape, skin color, and orientation due to the great advantages of technologies employed. Additionally, these technologies saved time and provided a base for reproducible results regardless of operator.


Assuntos
Desenho Assistido por Computador , Orelha Externa , Próteses e Implantes , Desenho de Prótese , Cirurgia Assistida por Computador/métodos , Materiais Biocompatíveis/química , Criança , Cor , Orelha Externa/anormalidades , Estética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Masculino , Impressão Tridimensional , Pigmentação em Prótese/métodos , Implantação de Prótese/métodos , Silicones/química , Propriedades de Superfície , Interface Usuário-Computador
8.
Dent Mater ; 39(8): 677, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37271602

RESUMO

OBJECTIVES: The antibacterial efficacy of silicone is improved by impregnating it with antimicrobials such as chlorohexidine and zinc oxide. The purpose of this study was to examine mechanical properties and bonding of maxillofacial silicone elastomer mixed with Zinc Oxide nanoparticles (ZnO-NP), and Chlorohexidine Diacetate Salt (CHX) at three different concentrations (1 %, 3 %, and 5 %). METHODS: Specimens of a silicone elastomer (M511) were prepared and divided into 7 groups. Group 1 was control of no additive. Groups 2-4 included silicone elastomer mixed with ZnO-NP (surface area = 67 m2/g) at 3 different concentrations (by weight %); 1 %, 3 % and 5 %. Groups 5-7 included silicone elastomer mixed with CHX at the same concentrations. Tear and tensile strengths, elongation percentage, modulus of elasticity, and shear bond strength to primed acrylic resin surfaces were evaluated. Data was analyzed with 1-way ANOVA, Bonferroni, and Dunnett's T3 post-hoc tests (P < 0.05). RESULTS: There was significant effect of the additives on the tensile strength, elongation percentage, tear strength, and shear bond strength (P < 0.05). Shear bond strengths ranged from 0.55 to 0.96 MPa. Silicone elastomer mixed with CHX (5 %) resulted in the highest shear bond strength (P < 0.05). Non-linear regressions between tensile strength and ZnO and CHX additives were 0.95 and 0.96 respectively. SIGNIFICANCE: All additives reduced the tensile strength of the silicone. However, CHX at 5 % optimized shear bond strength and thus is proposed in order to fabricate maxillofacial prostheses of sufficient mechanical properties, bonding and antimicrobial activity.


Assuntos
Colagem Dentária , Óxido de Zinco , Elastômeros de Silicone/química , Teste de Materiais , Resistência à Tração , Elasticidade , Propriedades de Superfície
9.
Angle Orthod ; 2023 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-36762903

RESUMO

OBJECTIVES: To assess the effect of piezocision on periodontal tissues and alveolar bone height and to detect lower second molar root resorption in piezocision-assisted mandibular second molar protraction compared to no-piezocision molar protraction. MATERIALS AND METHODS: Twenty-one subjects (four males, 17 females, aged 22.43 ± 2.83 years) who presented with bilateral extraction of lower first molars were included. The patients were divided into two groups; Group 1: Piezocision-assisted molar protraction (right or left side of subjects) in which piezocision was performed immediately before lower second molar protraction and, Group 2: No-piezocision molar protraction in which lower second molar protraction was not surgically assisted. Plaque index (PI), gingival index (GI), periodontal pocket depth (PPD), width of keratinized gingiva (WKG), gingival recession (GR), lower second molar mesial root resorption, alveolar bone height, and mandibular bone height were recorded at T1 (immediately before molar protraction) and at T2 (after second molar space closure). RESULTS: In the piezocision-assisted molar protraction group, significant changes were detected in the WKG (P < .001), GR (P < .05), and the mandibular bone height (P < .001). Compared to the no-piezocision group, piezocision-assisted molar protraction resulted in an increased WKG (P < .001) and less second molar mesial root resorption (P < .01). CONCLUSIONS: Piezocision does not have any detrimental effect on the periodontium and produces less root resorption.

10.
Med Educ Online ; 28(1): 2171700, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36751853

RESUMO

AIMS: To explore the global trends in blended learning in undergraduate dental education during the COVID pandemic and during the recovery phase by engaging with the students and faculty and evaluate the implications for dental education in the post-COVID era. METHODS: It was a pilot cross-sectional study which employed a convenience sampling technique to recruit representatives of dental faculty and undergraduate students in 80 dental institutions globally. A previously validated questionnaire consisting of a combination of closed and open-ended items was used for data collection. Responses to these online questionnaires were processed and analysed using the R statistical computing environment. RESULTS: A total of 320 dental students and 169 faculty members from 47 different dental institutions participated in the study. Video and Live Online Tutorials were considered to be the most effective method of online learning followed by online question banks by both groups. Significant differences were noted between faculty and students regarding time spent and effectiveness of online teaching and learning, respectively, both before and after the start of COVID. The results highlight the faculty need to engage more closely with the students to address their learning needs. Finally, the participants provided several recommendations regarding the future development of teaching and learning strategies as well as assessments in the post-pandemic era. CONCLUSIONS: This is the first study which explores blended learning in dental education with participants from multiple institutions in different regions of the globe. Compared to the faculty, students considered online learning to be less interactive and preferred learning activities and all assessments to be delivered face-to-face. The results underscore the need to adapt teaching practices to suit the learning needs of the students.


Assuntos
COVID-19 , Educação a Distância , Humanos , Projetos Piloto , Estudos Transversais , Currículo , Estudantes , Educação em Odontologia/métodos
11.
Gen Dent ; 60(5): e295-301, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23032236

RESUMO

This study sought to compare the fracture resistance of and categorize failure modes exhibited by fixed partial dentures (FPDs) supported by natural teeth, implants, or mixed tooth-implant abutments. Three groups utilized three different abutment combinations: all natural teeth, all implants, and a mixture of teeth and implants. The teeth were prepared and zero-angled titanium abutments were installed over the implants. Standardized conventional three-unit porcelain-fused-to-metal FPDs were fabricated, following the conventional ceramic build-up technique. The inner surfaces of the bridges were air-abraded (50 µm Aluminum Oxide at 80 psi), cleaned in an ultrasonic bath for 10 minutes, and cemented over abutments using glass ionomer cement. The FPDs were fixed in a universal testing machine and compressed to fracture using a three-unit metal block at a 5 mm/minute crosshead speed. Fracture loads ranged from 460 to 5,700 N. Bridges supported by either implant abutments only or mixed implant-tooth abutments showed higher fracture loads (2,940 and 3,390 N, respectively) than those supported entirely by natural teeth (1,386 N) (p < 0.05). However, fracture of the veneering porcelain was common among all types of abutments.


Assuntos
Dente Suporte , Implantes Dentários , Falha de Restauração Dentária , Análise do Estresse Dentário/métodos , Prótese Parcial Fixa , Teste de Materiais/métodos
12.
Gen Dent ; 57(4): 444-7, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19903631

RESUMO

A total of 100 working dies for fixed partial denture (FPD) abutments were prepared to fit 50 three-unit fixed-fixed conventional FPDs. For each FPD, the axial convergence angles between the mesial and distal axial walls of the abutment teeth were measured. For all FPDs, there were no statistically significant differences between the mesial and distal convergence angles of abutment teeth measured, regardless of their location within the oral cavity. The distal convergence angle of posterior FPD abutments was the highest angle, while the lowest was recorded for the mesial convergence angle of the anterior FPD abutments.


Assuntos
Dente Suporte , Prótese Parcial Fixa , Preparo Prostodôntico do Dente , Análise de Variância , Planejamento de Dentadura , Humanos
13.
J Contemp Dent Pract ; 10(2): 51-8, 2009 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-19279972

RESUMO

AIM: The aim of this study was to investigate the fracture resistance of two types of ceramic crowns cemented with two different cements. METHODS AND MATERIALS: Forty premolar crowns were fabricated using lithium-disilicate (IPS Empress-2) and glass-infiltrated aluminium-oxide (In-Ceram) ceramic systems. The crowns were divided into four groups (n=10) with Group 1 (IPS Empress-2) and Group 2 (In-Ceram) cemented with glass ionomer cement. Group 3 (IPS Empress-2) and Group 4 (In-Ceram) were cemented with resin cement. Crowns were tested in a universal testing machine at a compressive-load speed of 10 mm/min. Fracture modes were grouped into five categories. One way analysis of variance (ANOVA) and Bonferroni post-hoc tests were used to detect statistical significances (p<0.05). RESULTS: The mean (SD) fracture resistance (Newtons) for Groups 1 to 4 were: 245.35 (82.69), 390.48 (67.03), 269.69 (10.33), and 418.36 (26.24). The cement type had no statistical significant effect (p>0.05) on fracture resistance within each ceramic system tested. In-Ceram crowns cemented with either glass ionomer or resin cements exhibited a statistically significantly higher fracture-resistance than IPS Empress-2 crowns (p<0.05). Minimal fracture in the test crowns was the common mode exhibited. CONCLUSION: Fracture resistance of IPS Empress-2 and In-Ceram crowns was not affected by the type of cement used for luting. CLINICAL SIGNIFICANCE: Both In-Ceram and IPS Empress-2 crowns can be successfully luted with the cements tested with In-Ceram exhibiting higher fracture resistance than IPS Empress-2.


Assuntos
Óxido de Alumínio/química , Coroas , Cimentos Dentários/química , Porcelana Dentária/química , Falha de Restauração Dentária , Condicionamento Ácido do Dente , Cimentação/métodos , Planejamento de Prótese Dentária , Análise do Estresse Dentário/instrumentação , Adesivos Dentinários/química , Cimentos de Ionômeros de Vidro/química , Humanos , Compostos de Lítio/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
14.
J Contemp Dent Pract ; 9(4): 9-16, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18473022

RESUMO

AIM: The aim of this study was to evaluate the clinical performance of IPS-Empress 2(R) all-ceramic crowns placed by general dental practitioners. METHODS AND MATERIALS: Eighty-two IPS-Empress 2 crowns placed in 64 patients (27 females and 37 males) were evaluated. These crowns had been in place for 15.2 to 57.2 months (mean 25.3 months, SD=9.3). Survival analysis was conducted using the Kaplan-Meier method. RESULTS: Of the 82 crowns 93.9% were rated satisfactory. In terms of the integrity of the restorations, fracture was observed in three crowns and two showed a crack upon transillumination. Five crowns were rated unsatisfactory for color match; one for marginal adaptation; and none for discoloration, secondary caries, or sensitivity. CONCLUSIONS: IPS-Empress 2(R) is a suitable material to fabricate all-ceramic crowns; when these all-ceramic crowns were inserted by general dental practitioners, they functioned satisfactorily with low failure rates during an observation period ranging between 15.2 to 57.2 months.


Assuntos
Coroas , Porcelana Dentária/química , Compostos de Lítio/química , Adulto , Força de Mordida , Cor , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Feminino , Seguimentos , Odontologia Geral , Humanos , Masculino , Pessoa de Meia-Idade , Propriedades de Superfície , Análise de Sobrevida , Transiluminação , Resultado do Tratamento
15.
Quintessence Int ; 37(4): 311-7, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16594363

RESUMO

OBJECTIVE: It is common practice for clinicians to adjust the porcelain surfaces of dental prostheses. The change in surface roughness after different surface finishing techniques has attracted the attention of prosthodontists. The present study was undertaken to investigate the average surface roughness of 2 dental ceramics: IPS Empress 2 (layering glass-ceramic, Ivoclar Vivadent) and In-Ceram/Vitadur Alpha (Vita), either glazed, unglazed, or refinished using different techniques. METHOD AND MATERIALS: Disks of 6-mm diameter and 2-mm thickness were prepared from IPS Empress 2 and In-Ceram Alumina/Vitadur Alpha ceramics. Specimens were finished for 1 minute to the various stages provided in the sequence of instruments in the Shofu porcelain veneer kit. The average roughness measurements were taken from each specimen with a surface roughness tester. RESULTS: Significant differences in surface roughness were observed between the ceramics and among the finishing techniques used for both IPS Empress 2 and In-Ceram/Vitadur Alpha. It was found that unglazed IPS Empress 2 is rougher than unglazed In-Ceram/Vitadur Alpha. CONCLUSION: Regardless of the type of ceramic or pretreatment, any adjusted ceramic restoration should be reglazed or subjected to a finishing sequence that is followed through to a final stage of polishing with diamond paste.


Assuntos
Cerâmica/química , Polimento Dentário , Porcelana Dentária/química , Óxido de Alumínio/química , Polimento Dentário/instrumentação , Polimento Dentário/métodos , Diamante/química , Temperatura Alta , Humanos , Compostos de Lítio/química , Teste de Materiais , Propriedades de Superfície
16.
J Dent Educ ; 70(2): 179-87, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16478932

RESUMO

The aim of this study was to assess the knowledge, attitude, and behavior of school children towards oral health and dental care as well as to evaluate the factors that determine these variables. School children (n=557) of an average age of 13.5 years attending public schools in North Jordan were recruited into this study. The subjects completed a questionnaire that aimed to evaluate young school children's behavior, knowledge, and perception of their oral health and dental treatment. The participants' oral hygiene habits (such as tooth brushing) were found to be irregular, and parents' role in the oral hygiene habits of their children was limited. The study population showed higher awareness of caries than periodontal conditions. Irregular visits to the dentist were found to be common, and toothache was the major driving factor for dental visits. Children had positive attitudes toward their dentists; nevertheless, they indicated that they feared dental treatment. The children in this study also recognized the importance of oral health to the well-being of the rest of the body. Parents were not proactive in making sure that their children received regular dental care. Parents' knowledge and attitudes about the importance of oral health care and their fears about dental treatment influenced their children's dental care. The results of this study indicate that children's and parents' attitudes toward oral health and dental care need to be improved. Comprehensive oral health educational programs for both children and their parents are required to achieve this goal.


Assuntos
Assistência Odontológica/estatística & dados numéricos , Conhecimentos, Atitudes e Prática em Saúde , Saúde Bucal , Higiene Bucal/estatística & dados numéricos , Adolescente , Comportamento do Adolescente , Criança , Comportamento Infantil , Ansiedade ao Tratamento Odontológico/psicologia , Cárie Dentária/psicologia , Feminino , Gengivite/psicologia , Humanos , Jordânia , Masculino , Pais/psicologia , Inquéritos e Questionários
17.
J Contemp Dent Pract ; 7(4): 29-36, 2006 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-16957788

RESUMO

AIM: The objective of this study was to radiographically assess and compare the quality of post-retained crowns fabricated at the Dental Health Centre of the Jordan University of Science & Technology (JUST). METHODS AND MATERIALS: Study data were collected in 2002 from existing dental records for all patients receiving treatment with post-retained crowns between October, 1997 and June, 1999. The posts were assessed radiographically to evaluate various aspects of the quality of post-retained crowns. All 129 posts were fabricated in the dental school. RESULTS: The most-frequently restored teeth were the maxillary incisors (38.8%). Sixty-two percent of the posts were tapered, while 38% were parallel-sided. The mean length of the posts was 0.95 mm (SD 0.41) with a range between 0.22-2.85 mm. Caries was diagnosed radiographically in 10.8% of cases with lesions located on root surfaces in 64.3% of them, while 35.7% of lesions were within the root canal. Three posts (2.3%) were deviated from the line of the root canal in the mesio-distal plane. No evidence of root filling was found in 2.3% of the cases. In the remainder of teeth 15.5% had gutta percha extended to the radiographic apex of the tooth, while 59.7% fell 0.5-1 mm short of the radiographic apex. Gutta-percha was extruded beyond the apex in 22.5% of the teeth. Space between the end of the post and the root filling was found in 22.2%. The percentage of canals with apparently completely healthy periapical tissue was 51.2%. In the rest of the cases 34.8% had areas of radiolucency at or near the root apices and 14% demonstrated widening of the periodontal space around the root apex. Root resection had been completed in 2.3% cases. Signs of external resorption were apparent in one case (0.78%). CONCLUSION: The standards of the treatment of the endodontically treated teeth made at the dental hospital were satisfactory but could be improved by a controlled academic supervisory environment and a strict scientific approach to fixed prosthodontics within the dental school.


Assuntos
Coroas , Cavidade Pulpar/diagnóstico por imagem , Técnica para Retentor Intrarradicular , Dente não Vital/diagnóstico por imagem , Adulto , Planejamento de Prótese Dentária , Humanos , Jordânia , Radiografia , Estudos Retrospectivos
18.
J Clin Pediatr Dent ; 30(4): 296-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16937854

RESUMO

OBJECTIVES: The aim of this study was to investigate any association between irregular teeth and periodontal breakdown among children who attend dental clinics regularly. METHODS: The subjects were 80 children (39 females and 41 males) with a mean age of 12.38 +/- 0.75 years. Each subject had an alginate impression in the mandibular arch, periapical radiographs for the lower incisor teeth and clinical examination for periodontal health. Plaque accumulation, gingival condition and probing depth, bone level and status of lower incisor teeth contact areas were recorded. Spearman correlation test was used to observe any relationship between the clinical variables. RESULTS: The average probing depth, gingival index and plaque index scores in the subjects studied were 1.3 +/- 0.25, 0.99 +/- 0.28 and 1.17 +/- 0.52 respectively. The average number of sites with labiolingual displacement with mesiodistal overlap was 1.81 +/- 1.30 and those without mesiodistal overlap was 1.39 +/- 1.10. The average number of contact areas with spacing was 0.59 +/- 1.23. The correlation observed between irregularity and periodontal health indicated no association between the number and type of displacement and plaque accumulation, gingivitis, attachment loss and alveolar bone level. CONCLUSION: There was no association between irregularity of teeth and periodontal diseases in presence of good oral hygiene.


Assuntos
Perda do Osso Alveolar/etiologia , Má Oclusão/complicações , Doenças Mandibulares/etiologia , Doenças Maxilares/etiologia , Doenças Periodontais/etiologia , Criança , Índice de Placa Dentária , Feminino , Humanos , Masculino , Índice Periodontal , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
19.
Dent Update ; 33(9): 561-2, 564-6, 569-70, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17176743

RESUMO

This article reviews several cases of foreign body ingestion or inhalation reported in the literature. Prevention, complication and management of this event are discussed and three case reports presented. Two of the cases were bridge ingestion and one was ingestion of an orthodontic band. The three cases were managed by watchful waiting and the ingested foreign bodies came out in the stools without complications.


Assuntos
Dentaduras , Corpos Estranhos/complicações , Intestino Grosso , Intestino Delgado , Braquetes Ortodônticos , Adolescente , Adulto , Prótese Parcial , Prótese Parcial Fixa , Feminino , Corpos Estranhos/prevenção & controle , Corpos Estranhos/terapia , Humanos , Aspiração Respiratória/complicações
20.
Community Dent Oral Epidemiol ; 30(6): 418-22, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12453112

RESUMO

OBJECTIVES: The aim of this study was to determine whether beta-thalassemia major is associated with an increase in the severity of periodontal disease and dental caries. METHODS: A total of 61 thalassemia patients and 63 healthy controls (age range = 6-18 years) were examined for plaque deposits, gingivitis, periodontitis and dental caries using Silness and Löe plaque index (Pl.I), Löe and Silness gingival index (GI), probing pocket depth (PPD) and DMFT, respectively. RESULTS: There were no significant differences in Pl.I, GI and PPD scores between both thalassemia patients and healthy control groups (P > 0.05). Dental caries was significantly higher in thalassemia patients group (P < 0.0001) compared to the healthy controls. CONCLUSION: Thalassemia is not associated with increased levels of gingivitis or periodontitis but is associated with higher dental caries experience.


Assuntos
Cárie Dentária/etiologia , Gengivite/etiologia , Periodontite/etiologia , Talassemia beta/complicações , Adolescente , Estudos de Casos e Controles , Criança , Índice CPO , Assistência Odontológica para Doentes Crônicos , Índice de Placa Dentária , Feminino , Humanos , Masculino , Índice Periodontal , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA