Resultados 1 - 20 de 42
Filtrar
1.
J Clin Microbiol ; 58(7)2020 06 24.
Artigo em Inglês | MEDLINE | ID: mdl-32321782

RESUMO

Our objective was to evaluate the diagnostic yield and accuracy of the BioFire FilmArray pneumonia panel (BFPP) for identification of pathogens in lower respiratory tract specimens (n = 200) from emergency department (ED) and intensive care unit (ICU) patients at a tertiary care academic medical center. Specimens were collected between January and November 2018, from patients ≥18 years of age, and culture was performed as part of standard-of-care testing. The BFPP identified a viral or bacterial target in 117/200 (58.5%) samples, including Staphylococcus aureus in 22% of samples and Haemophilus influenzae in 14%, and both a viral and bacterial target in 4% of samples. The most common viruses detected by BFPP were rhinovirus/enterovirus (4.5%), influenza A virus (3%), and respiratory syncytial virus (RSV) (2%). Overall, there was strong correlation between BFPP and standard methods for detection of viruses (99.2%) and bacteria (96.8%). Most bacteria (60/61 [98.4%]) detected by standard methods were also identified by BFPP, and 92 additional bacteria were identified by BFPP alone, including 22/92 (23.9%) additional S. aureus isolates and 25/92 (27.2%) H. influenzae isolates, which were more frequently discordant when detected at low concentrations (S. aureus, P < 0.001; H. influenzae, P < 0.0001) and in sputum-type specimens (S. aureus, P < 0.05). A potential limitation of the BFPP assay is the absence of fungal targets and Stenotrophomonas maltophilia, which were detected in 26 and 4 of 200 specimens, respectively. Real-time specimen analysis with BFPP has the potential to identify bacterial pathogens and resistance markers 44.2 and 56.3 h faster than culture-based methods. The BFPP is a rapid and accurate method for detection of pathogens from lower respiratory tract infections.


Assuntos
Pneumonia , Infecções Respiratórias , Centros Médicos Acadêmicos , Bactérias/genética , Humanos , Técnicas de Diagnóstico Molecular , Infecções Respiratórias/diagnóstico , Staphylococcus aureus , Atenção Terciária à Saúde
2.
Clin Chem ; 66(8): 1055-1062, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32402061

RESUMO

BACKGROUND: The recent emergence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has resulted in a rapid proliferation of serologic assays. However, little is known about their clinical performance. Here, we compared two commercial SARS-CoV-2 IgG assays. METHODS: 103 specimens from 48 patients with PCR-confirmed SARS-CoV-2 infections and 153 control specimens were analyzed using SARS-CoV-2 serologic assays by Abbott and EUROIMMUN (EI). Duration from symptom onset was determined by medical record review. Diagnostic sensitivity, specificity, and concordance were calculated. RESULTS: The Abbott SARS-CoV-2 assay had a diagnostic specificity of 99.4% (95% CI; 96.41-99.98%), and sensitivity of 0.0% (95% CI; 0.00-26.47%) at <3 days post symptom onset, 30.0% (95% CI; 11.89-54.28) at 3-7d, 47.8% (95% CI; 26.82-69.41) at 8-13d and 93.8% (95% CI; 82.80-98.69) at ≥14d. Diagnostic specificity on the EI assay was 94.8% (95% CI; 89.96-97.72) if borderline results were considered positive and 96.7% (95% CI; 92.54-98.93) if borderline results were considered negative. The diagnostic sensitivity was 0.0% (95% CI; 0.00-26.47%) at <3d, 25.0% (95% CI; 8.66-49.10) at 3-7d, 56.5% (95% CI; 34.49-76.81) at 3-7d and 85.4% (95% CI; 72.24-93.93) at ≥14d if borderline results were considered positive. The qualitative concordance between the assays was 0.83 (95% CI; 0.75-0.91). CONCLUSION: The Abbott SARS-CoV-2 assay had fewer false positive and false negative results than the EI assay. However, diagnostic sensitivity was poor in both assays during the first 14 days of symptoms.


Assuntos
Anticorpos Antivirais/sangue , Betacoronavirus/imunologia , Infecções por Coronavirus/diagnóstico , Pneumonia Viral/diagnóstico , Anticorpos Antivirais/imunologia , Betacoronavirus/isolamento & purificação , COVID-19 , Infecções por Coronavirus/virologia , Reações Falso-Positivas , Humanos , Imunoensaio/instrumentação , Imunoensaio/métodos , Imunoglobulina G/análise , Imunoglobulina G/imunologia , Pandemias , Pneumonia Viral/virologia , Kit de Reagentes para Diagnóstico , Reprodutibilidade dos Testes , SARS-CoV-2 , Sensibilidade e Especificidade , Fatores de Tempo
3.
Clin Chem ; 66(12): 1538-1547, 2020 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-32894750

RESUMO

BACKGROUND: Commercially available SARS-CoV-2 serological assays based on different viral antigens have been approved for the qualitative determination of anti-SARS-CoV-2 antibodies. However, there are limited published data associating the results from commercial assays with neutralizing antibodies. METHODS: Sixty-six specimens from 48 patients with PCR-confirmed COVID-19 and a positive result by the Roche Elecsys Anti-SARS-CoV-2, Abbott SARS-CoV-2 IgG, or EUROIMMUN SARS-CoV-2 IgG assays and 5 control specimens were analyzed for the presence of neutralizing antibodies to SARS-CoV-2. Correlation, concordance, positive percent agreement (PPA), and negative percent agreement (NPA) were calculated at several cutoffs. Results were compared in patients categorized by clinical outcomes. RESULTS: The correlation between SARS-CoV-2 neutralizing titer (EC50) and the Roche, Abbott, and EUROIMMUN assays was 0.29, 0.47, and 0.46, respectively. At an EC50 of 1:32, the concordance kappa with Roche was 0.49 (95% CI; 0.23-0.75), with Abbott was 0.52 (0.28-0.77), and with EUROIMMUN was 0.61 (0.4-0.82). At the same neutralizing titer, the PPA and NPA for the Roche was 100% (94-100) and 56% (30-80); Abbott was 96% (88-99) and 69% (44-86); and EUROIMMUN was 91% (80-96) and 81% (57-93) for distinguishing neutralizing antibodies. Patients who were intubated, had cardiac injury, or acute kidney injury from COVID-19 infection had higher neutralizing titers relative to those with mild symptoms. CONCLUSIONS: COVID-19 patients generate an antibody response to multiple viral proteins such that the calibrator ratios on the Roche, Abbott, and EUROIMMUN assays are all associated with SARS-CoV-2 neutralization. Nevertheless, commercial serological assays have poor NPA for SARS-CoV-2 neutralization, making them imperfect proxies for neutralization.


Assuntos
Anticorpos Neutralizantes/análise , Anticorpos Antivirais/análise , Teste Sorológico para COVID-19/estatística & dados numéricos , COVID-19/imunologia , Imunoensaio/estatística & dados numéricos , SARS-CoV-2/imunologia , Idoso , Anticorpos Neutralizantes/imunologia , Anticorpos Antivirais/imunologia , COVID-19/epidemiologia , Proteínas do Nucleocapsídeo de Coronavírus/imunologia , Correlação de Dados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fosfoproteínas/imunologia , Curva ROC , SARS-CoV-2/química , Índice de Gravidade de Doença , Glicoproteína da Espícula de Coronavírus/imunologia
4.
J Clin Microbiol ; 57(6)2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30944186

RESUMO

Diarrheal illness is a major cause of morbidity and mortality throughout the world, yet the etiologic agent of many cases of gastrointestinal illness remains unspecified, often due to the lack of convenient, timely, and sensitive diagnostic testing. Although bulk fecal specimens remain the recommended specimen type for enteric culture, rectal swabs may be an option preferred by clinicians and patients due to the convenience and timing of collection. However, the lack of data evaluating the sensitivity of rectal swabs compared to fecal specimens for detection of enteric pathogens precludes this specimen type from being recommended by national guidelines. In this study, we retrospectively reviewed 480 paired rectal swab and fecal specimens submitted for enteric culture to the Barnes-Jewish Hospital and St. Louis Children's Hospital microbiology laboratories in St. Louis, MO, from 2002 to 2017. We report 32% positivity of paired specimens with an overall agreement of 93% and Cohen's κ of 0.84 (95% confidence interval, 0.78 to 0.89). Additionally, we evaluated the time to result from the time of patient presentation to the health care setting and demonstrate that rectal swabs have a significantly shorter time to an actionable result than bulk fecal specimens (median, 67.4 h versus 78.4 h, respectively; P < 0.001). These findings indicate that rectal swabs facilitate on-demand culture-based testing with a sensitivity comparable to that of fecal specimens and thus should be recommended for enteric bacterial culture when bulk fecal specimens are unavailable.


Assuntos
Técnicas de Tipagem Bacteriana , Fezes/microbiologia , Gastroenterite/diagnóstico , Gastroenterite/microbiologia , Microbioma Gastrointestinal , Reto/microbiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Diarreia/diagnóstico , Diarreia/microbiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Manejo de Espécimes , Adulto Jovem
5.
J Clin Microbiol ; 57(1)2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30429251

RESUMO

Manual treponemal and nontreponemal serologic testing has historically been used for the diagnosis of syphilis. This approach is simple and reproducible but labor intensive. Recently, the FDA cleared the fully automated BioPlex 2200 Syphilis Total & RPR assay for the detection of treponemal and nontreponemal antibodies. We evaluated the clinical performance of this assay at a tertiary medical center with a high syphilis prevalence. Prospective consecutively collected (n = 400) and known RPR-positive (n = 100) specimens were compared using predicate manual rapid plasma reagin (RPR) and fluorescent treponemal antibody absorption (FTA) methods and the BioPlex 2200 Syphilis Total & RPR assay. Positive and negative percent agreements (PPA and NPA, respectively) between the assays were calculated. The PPA and NPA between the manual and BioPlex 2200 RPR results for the prospective population were 85% (17/20; 95% confidence interval [CI], 69% to 100%) and 98% (373/380; 95% CI, 97% to 99%), respectively. The PPA for the manual RPR-positive population was 88% (88/100; 95% CI, 82% to 94%). Overall, the manual and BioPlex 2200 RPR titers demonstrated 78% (99/127) concordance within ±1 dilution and 94% (120/127) within ±2 dilutions. An interpretation of the syphilis serologic profile using the traditional algorithm showed a concordance of 99.5% in the prospective population and 85% in the manual RPR-positive cohort. The performance of the BioPlex 2200 Syphilis Total & RPR assay is comparable to those of manual methods. The high NPA of this assay combined with the ability to automate a historically labor-intensive assay is an appealing attribute for syphilis screening in a high-volume laboratory.


Assuntos
Técnicas Imunoenzimáticas , Programas de Rastreamento/métodos , Sorodiagnóstico da Sífilis/métodos , Sífilis/diagnóstico , Treponema/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Anticorpos Antibacterianos/sangue , Automação Laboratorial , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Kit de Reagentes para Diagnóstico , Reaginas/sangue , Sífilis/sangue , Sífilis/microbiologia , Centros de Atenção Terciária , Treponema/imunologia , Adulto Jovem
6.
J Clin Microbiol ; 56(10)2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30093393

RESUMO

There is limited knowledge on the yield of performing multiplex nucleic acid testing (NAT) on multiple lower respiratory tract specimens from a single patient with a single instance of infection. We evaluated the performance characteristics of multiplex NAT assays performed concurrently on bronchoalveolar lavage (BAL) and bronchial wash (BW) specimens to detect respiratory pathogens. A retrospective study of admitted patients from March 2013 through December 2016 was performed. Individual performance characteristics of BAL and BW specimens were compared to positive results from either set of specimens. Only contemporaneous BAL and BW specimens (received by the laboratory within 4 h of each other) were included. The final cohort included 170 patients, with 184 contemporaneous BAL and BW specimens submitted for multiplex NAT (median age, 58 years; 62% male). Of the patients with positive NAT results, 38 of 40 BW specimens tested positive (overall percent agreement with combined testing, 98.9%; 95% confidence interval [CI], 95.5 to 98.9%), and 34 of 40 BAL specimens tested positive (overall percent agreement with combined testing, 96.7%; 95% CI, 93.0 to 96.7%). Assays performed on BW specimens identified 4 additional specimens and had a higher positive percent agreement (95.0%) with combined testing results compared to those performed on BAL specimens (85.0%). There was exact concordance in 174 specimens (94.6%; negative and positive for respiratory pathogens, 144 and 34 specimens, respectively). We observed high concordance (95%) between multiplex NAT results from contemporaneous BAL and BW specimens. Performance characteristics of BW specimen testing were equivalent to those of BAL specimen testing. The benefit of performing additional testing should be carefully considered against the potential complications and health care costs.


Assuntos
Líquido da Lavagem Broncoalveolar/virologia , Técnicas de Diagnóstico Molecular/métodos , Infecções Respiratórias/diagnóstico , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase Multiplex , Infecções Respiratórias/virologia , Estudos Retrospectivos , Vírus/classificação , Vírus/genética , Vírus/isolamento & purificação
7.
Eur J Clin Microbiol Infect Dis ; 37(12): 2405-2411, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30269180

RESUMO

Total laboratory automation (TLA) has the potential to reduce specimen processing time, improve standardization of cultures, and decrease turnaround time (TAT). The objective of this study was to perform a detailed interrogation of the impact of TLA implementation in all aspects of the workflow for routine culture of urine specimens. Using a detailed motion capture study, the time required for major steps of processing and result reporting were prospectively assessed for urine samples prior to (n = 215) and after (n = 203) implementation of the BD Kiestra TLA system. Specimens were plated on all shifts, but cultures were read only during the day shift for both time periods. Significant increases were noted in the time from receipt to inoculation (23.0 min versus 32.0 min, p < 0.001) and total processing time (28.0 min versus 66.0 min, p < 0.0001) for urine specimens post-TLA. Rates of positive (18.6% versus 16.3%) and negative (71.2% versus 79.3%) urine cultures remained stable through the pre- and post-TLA time periods (p = 0.58). There were no changes in TAT for organism identification or susceptibility results. The time to final report was decreased from 43.8 h pre-TLA to 42.0 h post-TLA, which was attributed to significant decreases in TAT for negative cultures (42.0 h versus 37.5 h, p = 0.01). These findings demonstrate that changes in laboratory workflow are necessary to maximize efficiency of TLA and optimize TAT.


Assuntos
Automação Laboratorial , Técnicas Bacteriológicas/instrumentação , Manejo de Espécimes/instrumentação , Fluxo de Trabalho , Técnicas Bacteriológicas/métodos , Humanos , Estudos de Tempo e Movimento , Urina/microbiologia
9.
J Clin Microbiol ; 54(1): 5-6, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26560538

RESUMO

An article in this issue of the Journal of Clinical Microbiology (J.-H. Youn, S. K. Drake, R. A. Weingarten, K. M. Frank, J. P. Dekker, and A. F. Lau, J Clin Microbiol 53:35-42, 2015, http://dx.doi.org/10.1128/JCM.01643-15) describes the use of matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry for the detection of organisms carrying a blaKPC-containing plasmid. This powerful and promising application highlights the challenges of using MALDI-TOF mass spectrometry for purposes other than organism identification.


Assuntos
Resistência Microbiana a Medicamentos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Humanos
10.
J Clin Microbiol ; 53(1): 343-5, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25355765

RESUMO

We report a case of a 62-year-old female with seizures and encephalitis. Molecular testing of the patient's cerebrospinal fluid was positive for both herpes simplex virus 1 and 2 (HSV-1 and HSV-2). To our knowledge, this is the first report of simultaneous detection of HSV-1 and HSV-2 in cerebrospinal fluid.


Assuntos
DNA Viral/líquido cefalorraquidiano , Encefalite , Herpes Simples , Herpesvirus Humano 1/genética , Herpesvirus Humano 2/genética , Convulsões , Aciclovir/uso terapêutico , Antivirais/uso terapêutico , Feminino , Herpes Simples/líquido cefalorraquidiano , Herpes Simples/complicações , Herpes Simples/virologia , Humanos , Pessoa de Meia-Idade
19.
J Clin Microbiol ; 52(1): 2-8, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24131689

RESUMO

Herpes simplex virus 1 (HSV-1) and 2 (HSV-2) cause a variety of human diseases, ranging from acute to chronic and mild to severe. The absence of curative therapy results in lifelong carriage marked by recurrent outbreaks and allows transmission of the virus to uninfected individuals. Nonspecific lesions, variable presentation, and chronic carriage necessitate the use of different laboratory testing methods appropriate for each presentation. A thorough understanding of the performance characteristics and limitations of available tests is critical for selection of the appropriate test and interpretation of results. Clinical sensitivity, specificity, and selection of the appropriate methodology is paramount to avoid misdiagnosis and guide therapy. In this article we review the different methods for detection and typing of HSV, including light microscopy, culture, serology, and nucleic acid-based tests. We discuss the strengths and weaknesses of each method for diagnosing HSV infection, cite performance characteristics, and review appropriate clinical uses.


Assuntos
Herpes Simples/diagnóstico , Microscopia/métodos , Técnicas de Diagnóstico Molecular/métodos , Simplexvirus/isolamento & purificação , Herpes Simples/virologia , Humanos , Sensibilidade e Especificidade , Testes Sorológicos/métodos , Cultura de Vírus/métodos
20.
J Clin Microbiol ; 52(4): 1222-4, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24430460

RESUMO

We compared the BD MAX enteric bacterial panel (EBP) to culture for the detection of Salmonella, Shigella, Campylobacter, and Shiga toxin-producing enterohemorrhagic Escherichia coli (EHEC) O157 in seeded stool samples. The EBP panel demonstrated superior sensitivity and reliably detected Salmonella, EHEC O157, Shigella, and Campylobacter at concentrations 1- to 2-log10 lower than those needed for culture detection.


Assuntos
Técnicas Bacteriológicas/métodos , Campylobacter/isolamento & purificação , Diarreia/diagnóstico , Enterobacteriaceae/isolamento & purificação , Fezes/microbiologia , Humanos , Técnicas de Diagnóstico Molecular/métodos , Sensibilidade e Especificidade