Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Jpn J Ophthalmol ; 68(4): 321-326, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38795195

RESUMO

PURPOSE: To investigate the efficacy of our wearable night-vision aid in patients with concentric peripheral visual field loss. STUDY DESIGN: Prospective, single blind, three-group, and three-period crossover clinical study. METHODS: The study included patients with concentric peripheral visual field loss, a best-corrected visual acuity (decimal visual acuity) of 0.1 or higher in the better eye, and the presence of a central visual field. HOYA MW10 HiKARI® (HOYA Corporation), our original wearable night-vision aid, was used as the test device with three types of camera lenses (standard-, middle-, and wide-angle lenses). Under both bright and dark conditions, the angle of the horizontal visual field was measured using each of the three lens types for each group. The baseline angle was measured when each participant wore the night-vision aid (powered off). RESULTS: The study included 21 participants. Under bright condition, the perceived horizontal visual field was significantly wider than the baseline setup when using the standard-angle lens ("the standard lens"); the middle-angle lens ("the middle lens") was significantly wider than both the baseline setup and the standard lens; and the wide-angle lens ("the wide lens") was significantly wider than the other lenses. Under dark condition, the perceived horizontal visual field was again significantly wider when using the middle lens than the baseline setup and the standard lens, and when using the wide lens, the perceived horizontal visual field was again wider than when using the other lenses. The control in the bright condition was significantly wider (p < 0.001) than when used in the dark condition, while the standard-angle lens in the dark condition was significantly wider (p = 0.05) than when used in the bright condition. In regards to the middle and wide lenses, there was no statistically significant result emerging from either of the illumination conditions. CONCLUSION: Our wearable night-vision aid with a middle-angle or wide-angle lens appears to provide wider visual field images in patients with concentric peripheral visual field loss, regardless of whether the illumination conditions are bright or dark.


Assuntos
Estudos Cross-Over , Acuidade Visual , Campos Visuais , Dispositivos Eletrônicos Vestíveis , Humanos , Estudos Prospectivos , Masculino , Feminino , Campos Visuais/fisiologia , Acuidade Visual/fisiologia , Método Simples-Cego , Idoso , Pessoa de Meia-Idade , Visão Noturna/fisiologia , Resultado do Tratamento , Escotoma/fisiopatologia , Escotoma/diagnóstico , Óculos , Auxiliares Sensoriais , Desenho de Equipamento , Testes de Campo Visual , Adulto
2.
Luminescence ; 27(5): 328-33, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23044769

RESUMO

A two-dimensional gaseous ethanol visualization system has been developed and demonstrated using a horseradish peroxidase-luminol-hydrogen peroxide system with high-purity luminol solution and a chemiluminescence (CL) enhancer. This system measures ethanol concentrations as intensities of CL via the luminol reaction. CL was emitted when the gaseous ethanol was injected onto an enzyme-immobilized membrane, which was employed as a screen for two-dimensional gas visualization. The average intensity of CL on the substrate was linearly related to the concentration of standard ethanol gas. These results were compared with the CL intensity of the CCD camera recording image in the visualization system. This system is available for gas components not only for spatial but also for temporal analysis in real time. A high-purity sodium salt HG solution (L-HG) instead of standard luminol solution and an enhancer, eosin Y (EY) solution, were adapted for improvement of CL intensity of the system. The visualization of gaseous ethanol was achieved at a detection limit of 3 ppm at optimized concentrations of L-HG solution and EY.


Assuntos
Etanol/química , Gases/química , Substâncias Luminescentes/química , Medições Luminescentes/métodos , Luminol/química , Peroxidase do Rábano Silvestre/química , Luminescência , Medições Luminescentes/instrumentação
3.
Intern Med ; 61(3): 379-383, 2022 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-34373373

RESUMO

A 16-year-old boy with asthma participated in recovery volunteer work following the 2018 heavy rains in Japan. One month later, he experienced chest pain and dyspnea. Chest computed tomography revealed a cavity with a fungal ball, and Aspergillus fumigatus was detected in his bronchoalveolar lavage fluid. He was treated with voriconazole, but new consolidations appeared rapidly. He also experienced allergic bronchopulmonary aspergillosis. After prednisolone prescription, the consolidations improved; however, his asthma worsened. He underwent partial lung resection to avoid allergens, and his symptoms improved. We must recognize cases of infection after a disaster, especially in patients with chronic respiratory diseases.


Assuntos
Aspergilose Broncopulmonar Alérgica , Aspergilose Pulmonar , Adolescente , Aspergilose Broncopulmonar Alérgica/complicações , Aspergilose Broncopulmonar Alérgica/diagnóstico , Aspergillus fumigatus , Humanos , Japão , Pulmão , Masculino , Aspergilose Pulmonar/complicações , Aspergilose Pulmonar/diagnóstico , Chuva
4.
Analyst ; 136(18): 3680-5, 2011 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-21785800

RESUMO

A novel imaging system of ethanol in exhaled breath induced by acetaldehyde dehydrogenase (ALDH2)-related alcohol metabolism has been developed. The system provides an image of ethanol distribution as chemiluminescence (CL) on an enzyme-immobilized support. The spatiotemporal change of CL generated by ethanol in exhaled breath after oral administration of ethanol was detected by employing an electron multiplier CCD (EM-CCD) camera, illustrated and analyzed. Prior to measurement of standard gaseous ethanol and ethanol in exhaled breath, the system was optimized by investigating the enzyme-immobilized supports, concentration of substrate and pH condition of Tris-HCl buffer solution. The ethanol skin patch test, a simple method as an indicator of ALDH2, was performed on healthy volunteers. Breath samples of 5 volunteers with ALDH2 (+) and 5 volunteers with ALDH2 (-) were used for exhaled ethanol analysis. Concentration-time profiles of exhaled ethanol obtained from all volunteers were analyzed over a period of 120 min after oral administration of ethanol (0.4 g per kg body weight) in the form of beer which contains 5% of alcohol. The results obtained from the system showed that the peaks of exhaled ethanol concentrations appeared at 30 min, which was considered as a rapid ethanol absorption phase following first-order kinetics. Exhaled ethanol concentrations of volunteers with ALDH2 (+) were lower than volunteers with ALDH2 (-) and the digestion of ethanol in volunteers with ALDH2 (+) was faster than in volunteers with ALDH2 (-). The eliminations were analyzed to follow zero-order kinetics with a rate constant for each group.


Assuntos
Aldeído Desidrogenase/metabolismo , Testes Respiratórios/métodos , Etanol/análise , Adulto , Aldeído-Desidrogenase Mitocondrial , Enzimas Imobilizadas/metabolismo , Etanol/metabolismo , Feminino , Humanos , Concentração de Íons de Hidrogênio , Cinética , Medições Luminescentes , Masculino
5.
Case Rep Oncol ; 14(2): 792-796, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34248541

RESUMO

We report the case of a 54-year-old man who was treated with nivolumab for recurrent squamous cell lung cancer. After 7 cycles of nivolumab treatment, the patient presented to our hospital with right eye vision loss. Gadolinium-enhanced magnetic resonance imaging of the brain showed enhancement around the optic nerve sheath. This finding and his symptoms led to the diagnosis of optic perineuritis (OPN). Steroid pulse therapy was administered twice although there was no remarkable improvement in his visual field defect. The relationship between OPN and nivolumab is unclear. However, immune-related adverse events caused by immune checkpoint inhibitors should be considered.

6.
Talanta ; 82(3): 892-8, 2010 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-20678642

RESUMO

A novel 2-dimensional spatiotemporal visualization system of expired gaseous ethanol after oral administration for real-time illustrated analysis of alcohol metabolism has been developed, which employed a low level light CCD camera to detect chemiluminescence (CL) generated by catalytic reactions of standard gaseous ethanol and expired gaseous ethanol after oral administration. First, the optimization of the substrates for visualization and the concentration of luminol solution for CL were investigated. The cotton mesh and 5.0 mmol L(-1) luminol solution were selected for further investigations and this system is useful for 0.1-20.0 mmol L(-1) of H(2)O(2) solution. Then, the effect of pH condition of Tris-HCl buffer solution was also evaluated with CL intensity and under the Tris-HCl buffer solution pH 10.1, a wide calibration range of standard gaseous ethanol (30-400 ppm) was obtained. Finally, expired air of 5 healthy volunteers after oral administration was measured at 15, 30, 45, 60, 75, 90, 105 and 120 min after oral administration, and this system showed a good sensitivity on expired gaseous ethanol for alcohol metabolism. The peaks of expired gaseous ethanol concentration appeared within 30 min after oral administration. During the 30 min after oral administration, the time variation profile based on mean values showed the absorption and distribution function, and the values onward showed the elimination function. The absorption and distribution of expired gaseous ethanol in 5 healthy volunteers following first-order absorption process were faster than the elimination process, which proves efficacious of this system for described alcohol metabolism in healthy volunteers. This system is expected to be used as a non-invasive method to detect VOCs as well as several other drugs in expired air for clinical purpose.


Assuntos
Etanol/análise , Expiração , Álcoois/metabolismo , Etanol/administração & dosagem , Etanol/farmacocinética , Gases , Humanos , Medições Luminescentes/métodos , Luminol , Compostos Orgânicos Voláteis/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA