Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 15(3): e0229856, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32126130

RESUMO

PURPOSE: To analyse nocturnal intraocular pressure (IOP) fluctuations in patients with obstructive sleep apnea syndrome (OSAS) using a contact lens sensor (CLS) and to identify associations between the OSAS parameters determined by polysomnographic study (PSG) and IOP changes. METHOD: Prospective, observational study. Twenty participants suspected of having OSAS were recruited. During PSG study, IOP was monitored using a CLS placed in the eye of the patient. The patients were classified according to the apnea-hypopnea index (AHI) in two categories, severe (>30) or mild/moderate (<30) OSAS. We evaluated several parameters determined by the IOP curves, including nocturnal elevations (acrophase) and plateau times in acrophase (PTs) defined by mathematical and visual methods. RESULTS: The IOP curves exhibited a nocturnal acrophase followed by PTs of varying extents at which the IOP remained higher than daytime measurement with small variations. We found significant differences in the length of the PTs in patients with severe OSAS compared to those with mild/moderate disease (P = 0.032/P = 0.028). We found a positive correlation between PTs and OSAS severity measured by the total number of apneic events (r = 0.681/0.751 P = 0.004/0.001) and AHI (r = 0.674/0.710, P = 0.004/0.002). Respiratory-related arousal and oxygen saturation also were associated significantly with the IOP PT length. CONCLUSIONS: Periods of nocturnal IOP elevation lasted longer in severe OSAS patients than those with mild/moderate OSAS and correlate with the severity of the disease. The length of the nocturnal PT is also associated to respiratory parameters altered in patients with OSAS.


Assuntos
Técnicas Biossensoriais , Glaucoma/diagnóstico , Monitorização Fisiológica/métodos , Apneia Obstrutiva do Sono/diagnóstico , Adulto , Idoso , Lentes de Contato/normas , Feminino , Glaucoma/fisiopatologia , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Polissonografia/métodos , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono/fisiopatologia , Tonometria Ocular/métodos
2.
JAMA Ophthalmol ; 135(4): 313-319, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-28241171

RESUMO

IMPORTANCE: It is important to evaluate intraobserver and interobserver agreement using visual field (VF) testing and optical coherence tomography (OCT) software in order to understand whether the use of this software is sufficient to detect glaucoma progression and to make decisions regarding its treatment. OBJECTIVE: To evaluate agreement in VF and OCT software among 5 glaucoma specialists. DESIGN, SETTING AND PARTICIPANTS: The printout pages from VF progression software and OCT progression software from 100 patients were randomized, and the 5 glaucoma specialists subjectively and independently evaluated them for glaucoma. Each image was classified as having no progression, questionable progression, or progression. The principal investigator classified the patients previously as without variability (normal) or with high variability among tests (difficult). Using both software, the specialists also evaluated whether the glaucoma damage had progressed and if treatment change was needed. One month later, the same observers reevaluated the patients in a different order to determine intraobserver reproducibility. MAIN OUTCOMES AND MEASURES: Intraobserver and interobserver agreement was estimated using κ statistics and Gwet second-order agreement coefficient. The agreement was compared with other factors. RESULTS: Of the 100 observed patients, half were male and all were white; the mean (SD) age was 69.7 (14.1) years. Intraobserver agreement was substantial to almost perfect for VF software (overall κ [95% CI], 0.59 [0.46-0.72] to 0.87 [0.79-0.96]) and similar for OCT software (overall κ [95% CI], 0.59 [0.46-0.71] to 0.85 [0.76-0.94]). Interobserver agreement among the 5 glaucoma specialists with the VF progression software was moderate (κ, 0.48; 95% CI, 0.41-0.55) and similar to OCT progression software (κ, 0.52; 95% CI, 0.44-0.59). Interobserver agreement was substantial in images classified as having no progression but only fair in those classified as having questionable glaucoma progression or glaucoma progression. Interobserver agreement was fair regarding questions about glaucoma progression (κ, 0.39; 95% CI, 0.32-0.48) and consideration about treatment changes (κ, 0.39; 95% CI, 0.32-0.48). The factors associated with agreement were the glaucoma stage and case difficulty. CONCLUSIONS AND RELEVANCE: There was substantial intraobserver agreement but moderate interobserver agreement among glaucoma specialists using 2 glaucoma progression software packages. These data suggest that these glaucoma progression software packages are insufficient to obtain high interobserver agreement in both devices except in patients with no progression. The low agreement regarding progression or treatment changes suggests that both software programs used in isolation are insufficient for decision making.


Assuntos
Glaucoma/diagnóstico , Tomografia de Coerência Óptica , Testes de Campo Visual , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Progressão da Doença , Feminino , Humanos , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Hipertensão Ocular/diagnóstico , Reprodutibilidade dos Testes , Software , Especialização , Tomografia de Coerência Óptica/normas , Testes de Campo Visual/normas , Campos Visuais/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA