Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Neurointerv Surg ; 13(12): 1157-1161, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33514612

RESUMO

BACKGROUND: ANA Advanced Neurovascular Access provides a novel funnel component designed to reduce clot fragmentation and facilitate retrieval in combination with stent-retrievers (SRs) in stroke patients by restricting flow and limiting clot shaving. In previous publications ANA presented excellent in vitro/in vivo efficacy data, especially with fibrin-rich hard clots. We aimed to determine the main physical property responsible for these results, namely suction force versus aspiration flow. METHODS: We evaluated in a bench model the suction force and flow generated by ANA and compared them to other neurovascular catheters combined with a SR (Solitaire). Aspiration flow was evaluated with a flow rate sensor while applying vacuum pressure with a pump. Suction force was determined using a tensile strength testing machine and a purposely designed tool that completely seals the device tip simulating complete occlusion by a hard clot. Suction force was defined as the force needed to separate the device from the clot under aspiration. All experiments were repeated five times, and mean values used for comparisons. RESULTS: Aspiration flow increased with the inner diameter of the device: ANA 1.85±0.04 mL/s, ACE68 3.74±0.05 mL/s, and 8F-Flowgate2 5.96±0.30 mL/s (P<0.001). After introducing the SR, the flow was reduced by an average of 0.57±0.12 mL/s. Due to its larger distal surface, ANA suction force (1.69±0.40 N) was significantly higher than ACE68 (0.26±0.04 N) and 8F-Flowgate2 (0.42±0.06 N) (P<0.001). After introducing the SR, suction force variation was not relevant except for ANA that increased to 2.64±0.41 N. CONCLUSION: Despite lower in vitro aspiration flow, the ANA design showed a substantially higher suction force than other thrombectomy devices.


Assuntos
Acidente Vascular Cerebral , Trombose , Humanos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Sucção , Trombectomia , Resultado do Tratamento
2.
Org Lett ; 8(5): 847-50, 2006 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-16494456

RESUMO

A new Suzuki-based strategy for the synthesis of 4,4'-diaryl (or heteroaryl)-substituted 2,2'-bipyrroles (10), precursors of 2,7,12,17-tetraaryl (or heteroaryl)-substituted porphycenes, is described. Bromination of the previously described diethyl 4H,5H-thieno[3,2-b:4,5-b']dipyrrole-3,6-dicarboxylate afforded dibromo compound 19, which is the key intermediate of such strategy.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA