Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
1.
Radiol Med ; 121(3): 190-9, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26519045

RESUMO

PURPOSE: It is unclear whether (and, to what extent) radiologists look at and report cardiovascular abnormalities on non-cardio-synchronized standard chest computed tomography (CT). In this study, the frequency and the reporting rate of cardiovascular findings in chest CT examinations were retrospectively assessed. MATERIALS AND METHODS: This study was approved by the institutional review board of each participating center. Four academic centers provided data on 447 subjects who underwent non-ECG-synchronized chest CT examinations for evaluating pulmonary fibrosis (161/447, 36 %), suspected pulmonary embolism (140/447, 31.3 %), or lung cancer staging (146/447, 32.7 %). A total of 220/447 (53.7 %) and 227/447 CT (46.3 %) examinations were evaluated and reported by junior and senior chest radiologists, respectively. Two radiologists with training in cardiac imaging reviewed the same chest CT images looking for the presence of incidental cardiovascular abnormalities using a preformatted score sheet. Inter-observer agreement was assessed using the kappa coefficient of agreement (k). RESULTS: Inter-observer agreement between the study reviewers was moderate to good (0.4-0.73) for most of the incidental cardiovascular findings. At least one incidental cardiovascular finding not documented in the original report was identified by the study reviewers in 225/409 (55 %) of chest CT examinations. A total of 168/266 (63.2 %) potentially clinically significant cardiovascular findings were unreported in the original reports of 177/447 (39.6 %) subjects (p < 0.0001). Senior radiologists tended to more frequently report coronary artery calcification (p = 0.0006), cardiac valves calcification (p = 0.0003), and ascending aorta enlargement (p = 0.01) compared to junior radiologists. CONCLUSIONS: Several cardiovascular abnormalities can be reliably identified on standard chest CT. Yet, they are often under-reported, even when they might be relevant to the patient's work-up.


Assuntos
Doenças Cardiovasculares/etiologia , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Achados Incidentais , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade , Embolia Pulmonar/diagnóstico por imagem , Fibrose Pulmonar/diagnóstico por imagem , Estudos Retrospectivos
2.
Radiol Med ; 120(12): 1122-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25981381

RESUMO

PURPOSE: The aim of the study was to evaluate the prevalence of collateral findings detected in computed tomography coronary angiography (CTCA) in a multi-center registry. MATERIALS AND METHODS: We performed a retrospective review of 4303 patients (2719 males, mean age 60.3 ± 10.2 years) undergoing 64-slice CTCA for suspected or known coronary artery disease (CAD) at various academic institutions between 01/2006 and 09/2010. Collateral findings were recorded and scored as: non-significant (no signs of relevant pathology, not necessary to be reported), significant (clear signs of pathology, mandatory to be reported), or major (remarkable pathology, mandatory to be reported and further investigated). RESULTS: We detected 6886 non-cardiac findings (1.6 non cardiac finding per patient). Considering all centers, only 865/4303 (20.1 %) patients were completely without any additional finding. Overall, 2095 (30.4 %) non-significant, 4486 (65.2 %) significant, and 305 (4.4 %) major findings were detected. Among major findings, primary lung cancer was reported in 21 cases. In every center, most prevalent significant findings were mediastinal lymph nodes >1 cm. In 256 patients, collateral findings were clinically more relevant than coexisting CAD and justified the symptoms of patients. CONCLUSIONS: The prevalence of significant and major collateral findings in CTCA is high. Radiologists should carefully evaluate the entire scan volume in each patient.


Assuntos
Angiografia Coronária , Tomografia Computadorizada por Raios X , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos
3.
Eur Radiol ; 23(3): 607-13, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23344906

RESUMO

Computed tomography coronary angiography (CTCA) has reached very high standards both in terms of diagnostic performance and radiation dose reduction. This commentary follows a report on CTCA using less than 0.1 mSv in selected patients. This is an extraordinary accomplishment, both for technology and for medicine. The difficult task is now to implement this tool in clinical practice so it can play the best possible role. CTCA can improve diagnostic pathways, can save money for healthcare systems and could even improve pharmacological therapy. All of this may happen, but it will require the combined effort of all the experienced operators in this field, including the referring clinicians. In times of financial constraint, CTCA may also help to restrict ineffective medical expenses.


Assuntos
Angiografia Coronária/economia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/economia , Custos de Cuidados de Saúde/estatística & dados numéricos , Proteção Radiológica/economia , Tomografia Computadorizada por Raios X/economia , Angiografia Coronária/métodos , Estudos de Viabilidade , Humanos , Doses de Radiação , Proteção Radiológica/estatística & dados numéricos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
4.
Eur Radiol ; 20(1): 81-7, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19657651

RESUMO

To evaluate the diagnostic accuracy of 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in patients with zero on the Agatston Calcium Score (CACS). We enrolled 279 consecutive patients (96 male, mean age 48 +/- 12 years) with suspected coronary artery disease. Patients were symptomatic (n = 208) or asymptomatic (n = 71), and underwent conventional coronary angiography (CAG). For CT-CA we administered an IV bolus of 100 ml of iodinated contrast material. CT-CA was compared to CAG using a threshold for significant stenosis of >or=50%. The prevalence of disease demonstrated at CAG was 15% (1.4% in asymptomatic). The population at CAG showed no or non-significant disease in 85% (238/279), single vessel disease in 9% (25/279), and multi-vessel disease in 6% (16/279). Sensitivity, specificity, and positive and negative predictive values of CT-CA vs. CAG on the patient level were 100%, 95%, 76%, and 100% in the overall population and 100%, 100%, 100%, and 100% in asymptomatic patients, respectively. CT-CA proves high diagnostic performance in patients with or without symptoms and with zero CACS. The prevalence of significant disease detected by CT-CA was not negligible in asymptomatic patients. The role of CT-CA in asymptomatic patients remains uncertain.


Assuntos
Calcinose/diagnóstico por imagem , Angiografia Coronária/métodos , Estenose Coronária/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Calcinose/complicações , Estenose Coronária/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Acta Biomed ; 86(1): 77-85, 2015 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-25948032

RESUMO

OBJECTIVES: To compare image quality of iterative reconstruction algorithm(IRIS) vs. standard filtered back projection(FBP) reconstruction in CT Coronary Angiography (CTCA). MATERIALS AND METHODS: Thirty-four consecutive patients underwent CTCA for suspected or known CAD with Dual-Source CT (DSCT-Flash, Siemens). All datasets were reconstructed with 0.75/0.4 and 0.6/0.4 mm slice thickness/increment, using three standard FBP kernels (B26-B30-B46) and three comparable IRIS algorithms (I26-I30-I46). Vascular attenuation and noise were measured. CT vascular attenuation values [HU] were measured in: ascending aorta (Ao), right (RCA) and left (LCA) coronary artery, respectively. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratio were calculated. A p-value<0.05 was considered significant. RESULTS: There was no significant difference between the vascular attenuation values measured with FBP (Ao:458HU, RCA:448HU, LAD:444HU) and IRIS (Ao:456HU, RCA:446HU, LAD:442HU). Difference in noise was significant between FBP (24±SD) and IRIS (19±SD) (r=0.34;p<0.05). Lowest noise was found for IRIS using 0.6 mm (17HU). IRIS provided a SNR and CNR significantly higher with increasing kernel sharpness. SNR was 33.3±25.1, 77.3±51.7, 37.2±36.6, 64.4±59.2, while CNR was 25.32±19.8, 58.0±36.0, 28.6±23.5, 47.6±47.3 for 0.75B, 0.75I, 0.6B and 0.6I, respectively. IRIS showed an improvement in SNR of 57% and 56% for 0.75 mm and 0.6 mm, respectively, and an improvement in CNR of 42% and 40% for 0.75 mm and 0.6 mm. CONCLUSIONS: In CTCA, iterative reconstructions provide a significant higher image quality compared with the conventional FBP reconstructions. (www.actabiomedica.it).


Assuntos
Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada por Raios X , Idoso , Algoritmos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
8.
Acta Biomed ; 86(3): 234-41, 2015 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-26694150

RESUMO

PURPOSE: preliminary evaluation of different dose reduction algorithms in abdominal Computed Tomography Angiography (CTA) with standard scan protocols at 120kV vs. 80kV. MATERIALS AND METHODS: prospective, randomized, crossover study. 60 consecutive patients who underwent CTA of the abdomen (Sensation 64, Siemens; Iomeprol 400 mgl/ml Bracco) for suspected or diagnosed Abdominal Aortic Aneurysm (AAA) were enrolled in the study. A standard 120kV/200mAs scan protocol was acquired in all patients (reference tube current modulated with Automatic Exposure Control). In each patient a second scan with 80kV/300mAs (Group 1; n. 20), 80kV/400mAs (Group 2; n. 20), 80kV/500mAs (Group 3; n. 20) was acquired. We used the same scan/reconstruction parameters with the same amount and kind of contrast medium. The radiation dose, the aortic attenuation values, the noise and the signal/noise ratio (S/N) were evaluated. RESULTS: the mean dose was 9.7±2.7mSv for 120kV (all patients), 3.6±0.8mSv in Group1 (80kV), 5.0±0.6mSv in Group 2 (80kV) and 5.9±1.2mSv in Group 3 (80kV), respectively. The aortic attenuation was 350±59HU (120kV) vs. 534±100HU (80kV), 12±3.5 (120kV) vs. 8.8±3.6 (80kV) for the whole population. Aortic attenuation and S/N were: 328±40HU (120kV) vs. 494±61HU (80kV), 11±2 (120kV) vs. 7±2 (80kV) in Group1; 353±77HU (120kV) vs. 551±117HU (80kV), 11±2.8HU (120kV) vs. 8.4±2.6 (80kV) in Group 2; 389±55HU (120kV) vs. 598±117HU (80kV), 15±5 (120kV) vs. 12±5 (80kV) in Group 3, respectively (p<0.05). CONCLUSION: in abdominal CTA, the 80kV/400mAs scan protocol allows a radiation dose reduction of 50% without a significant reduction of S/N ratio.


Assuntos
Angiografia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Estudos Cross-Over , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação
9.
Int J Cardiovasc Imaging ; 30(4): 769-71, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24481724

RESUMO

A 54-year-old male with history of cocaine abuse underwent trans-thoracic echocardiography that showed hyper-echogenicity of the basal segments of the septum and infero-lateral wall of the left ventricle. The patient underwent cardiac CT that reported diffuse non-obstructive CAD. Cardiac MR showed LGE patterns consistent with non-ischemic myocardial damage associated with cocaine abuse.


Assuntos
Transtornos Relacionados ao Uso de Cocaína/complicações , Cardiopatias/patologia , Ventrículos do Coração/patologia , Imagem Cinética por Ressonância Magnética , Doença Crônica , Meios de Contraste , Angiografia Coronária/métodos , Fibrose , Cardiopatias/induzido quimicamente , Cardiopatias/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X , Ultrassonografia
10.
World J Radiol ; 6(6): 381-7, 2014 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-24976939

RESUMO

AIM: To evaluate the feasibility of coronary artery calcium score (CACS) on low-dose non-gated chest CT (ngCCT). METHODS: Sixty consecutive individuals (30 males; 73 ± 7 years) scheduled for risk stratification by means of unenhanced ECG-triggered cardiac computed tomography (gCCT) underwent additional unenhanced ngCCT. All CT scans were performed on a 64-slice CT scanner (Somatom Sensation 64 Cardiac, Siemens, Germany). CACS was calculated using conventional methods/scores (Volume, Mass, Agatston) as previously described in literature. The CACS value obtained were compared. The Mayo Clinic classification was used to stratify cardiovascular risk based on Agatston CACS. Differences and correlations between the two methods were compared. A P-value < 0.05 was considered significant. RESULTS: Mean CACS values were significantly higher for gCCT as compared to ngCCT (Volume: 418 ± 747 vs 332 ± 597; Mass: 89 ± 151 vs 78 ± 141; Agatston: 481 ± 854 vs 428 ± 776; P < 0.05). The correlation between the two values was always very high (Volume: r = 0.95; Mass: r = 0.97; Agatston: r = 0.98). Of the 6 patients with 0 Agatston score on gCCT, 2 (33%) showed an Agatston score > 0 in the ngCCT. Of the 3 patients with 1-10 Agatston score on gCCT, 1 (33%) showed an Agatston score of 0 in the ngCCT. Overall, 23 (38%) patients were reclassified in a different cardiovascular risk category, mostly (18/23; 78%) shifting to a lower risk in the ngCCT. The estimated radiation dose was significantly higher for gCCT (DLP 115.8 ± 50.7 vs 83.8 ± 16.3; Effective dose 1.6 ± 0.7 mSv vs 1.2 ± 0.2 mSv; P < 0.01). CONCLUSION: CACS assessment is feasible on ngCCT; the variability of CACS values and the associated re-stratification of patients in cardiovascular risk groups should be taken into account.

11.
Int J Cardiol ; 176(3): 988-93, 2014 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-25213576

RESUMO

BACKGROUND: There is a growing evidence that carotid intima media thickness (CIMT) is associated with coronary artery disease (CAD) and it should be used as a predictor of atherosclerotic burden of coronary arteries. However, these studies have been performed by using invasive coronary angiography (ICA) and in high-risk patients for CAD. The purpose of this study was to evaluate the correlation between CIMT by ultrasound and coronary atherosclerosis in symptomatic intermediate risk patients by coronary computed tomography angiography (CCTA). METHODS: We enrolled 204 consecutive symptomatic patients (mean age: 61±10; men: 118) and intermediate risk for CAD. All patients underwent CIMT ultrasound evaluation and CCTA. Coronary artery calcium score (CACS), characteristics of plaques, severity of CAD, segment involvement score (SIS) and Gensini's score were assessed and compared with CIMT values. RESULTS: CIMT has been proved as an independent predictor of a number of coronary artery plaques, overall number of mixed and remodeled plaques, presence of obstructive CAD, high SIS and Gensini's score (HR 1.2, CI 1.05-1.42, p 0.01; HR 1.2, CI 1.01-1.41, p 0.03; HR 9.0, CI 1.37-59.7, p 0.02; HR 21.0, CI 2.40-184, p<0.01; HR 1.2, CI 1.08-1.42, p<0.01; HR 1.2, CI 1.08-1.42, p<0.01, respectively). A cut-off value>1.3 was associated with a better positive and negative predictive value (100% and 69%) to predict the combined endpoint of presence and mixed and/or remodeled coronary artery plaques. CONCLUSIONS: CIMT is an independent predictor of coronary atherosclerotic burden as detected by CCTA in symptomatic intermediate risk patients.


Assuntos
Espessura Intima-Media Carotídea , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Idoso , Doença da Artéria Coronariana/complicações , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROC , Fatores de Risco , Índice de Gravidade de Doença
12.
J Cardiovasc Med (Hagerstown) ; 14(10): 719-25, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-24335883

RESUMO

AIM: The aim of this study is to assess the image quality and diagnostic accuracy of computed tomography (CT) coronary angiography (CTCA) in different hospital settings with the same trained team. MATERIALS AND METHODS: Four hundred patients were consecutively enrolled for CTCA in a large academic hospital (Group 1; Sensation 64 Cardiac, Siemens - Iomeprol 400, Bracco; 200 patients) and in a small local hospital (Group 2; VCT, GE Healthcare - Iodixanol 320, GE Healthcare; 200 patients). All patients were enrolled for suspected coronary artery disease (CAD) and patients with stents or who had previously undergone coronary bypass were excluded. Scan protocols (retrospectively ECG-gated; no dose reduction modulation applied) were performed in accordance with standards reported in the international literature with the best solution available on site. Image quality was assessed in each coronary segment with a 4-point Likert scale: 0, not assessable; 1, low; 2, average; 3, good. Diagnostic accuracy was calculated against conventional coronary angiography with a threshold of at least 50% for significant stenosis. RESULTS: There was no significant difference between demographics, BMI, prevalence of obstructive CAD, calcium score and heart rate between the two populations. The average image quality was 2.83 ± 0.37 for Group 1 and 2.86 ± 0.31 for Group 2 (P > 0.05). Per-segment sensitivity, specificity, positive and negative predictive values were 92.6% (87-95), 97.9% (97-98), 75.9% (69-81) and 99.5% (99-99), respectively, for Group 1, and 90.4% (85-93), 98.6% (98-99), 84.2% (78-88) and 99.2% (98-99), respectively, for Group 2 (P > 0.05). CONCLUSION: There is no significant difference in image quality and diagnostic accuracy of CTCA when the investigation is performed by the same properly trained team. CTCA is a robust imaging modality for the detection of coronary artery stenosis.


Assuntos
Competência Clínica , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Curva de Aprendizado , Tomografia Computadorizada Multidetectores , Centros Médicos Acadêmicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Técnicas de Imagem de Sincronização Cardíaca , Meios de Contraste , Doença da Artéria Coronariana/epidemiologia , Estenose Coronária/epidemiologia , Eletrocardiografia , Feminino , Número de Leitos em Hospital , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prevalência , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Ácidos Tri-Iodobenzoicos
13.
World J Radiol ; 4(6): 265-72, 2012 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-22778879

RESUMO

AIM: To assess the attenuation of non-calcified atherosclerotic coronary artery plaques with computed tomography coronary angiography (CTCA). METHODS: Four hundred consecutive patients underwent CTCA (Group 1: 200 patients, Sensation 64 Cardiac, Siemens; Group 2: 200 patients, VCT GE Healthcare, with either Iomeprol 400 or Iodixanol 320, respectively) for suspected coronary artery disease (CAD). CTCA was performed using standard protocols. Image quality (score 0-3), plaque (within the accessible non-calcified component of each non-calcified/mixed plaque) and coronary lumen attenuation were measured. Data were compared on a per-segment/per-plaque basis. Plaques were classified as fibrous vs lipid rich based on different attenuation thresholds. A P < 0.05 was considered significant. RESULTS: In 468 atherosclerotic plaques in Group 1 and 644 in Group 2, average image quality was 2.96 ± 0.19 in Group 1 and 2.93 ± 0.25 in Group 2 (P ≥ 0.05). Coronary lumen attenuation was 367 ± 85 Hounsfield units (HU) in Group 1 and 327 ± 73 HU in Group 2 (P < 0.05); non-calcified plaque attenuation was 48 ± 23 HU in Group 1 and 39 ± 21 HU in Group 2 (P < 0.05). Overall signal to noise ratio was 15.6 ± 4.7 in Group 1 and 21.2 ± 7.7 in Group 2 (P < 0.01). CONCLUSION: Higher intra-vascular attenuation modifies significantly the attenuation of non-calcified coronary plaques. This results in a more difficult characterization between lipid rich vs fibrous type.

14.
J Cardiovasc Comput Tomogr ; 4(2): 144-6, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20430348

RESUMO

We report a case of young male with a penetrating chest trauma due to a gunshot. The bullet was detected by conventional X-ray and localized within the lateral wall of the left ventricle by CT. During surgery the bullet was not found. Thereafter conventional X-ray showed migration of the bullet within the lung parenchyma.


Assuntos
Migração de Corpo Estranho/diagnóstico por imagem , Traumatismos Cardíacos/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ferimentos por Arma de Fogo/diagnóstico por imagem , Adulto , Humanos , Pulmão/diagnóstico por imagem , Masculino
16.
J Cardiovasc Med (Hagerstown) ; 10(12): 913-20, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19550352

RESUMO

PURPOSE: To determine the relationship between established cardiovascular risk factors, clinical presentation and the extent of coronary artery disease (CAD), as described with computed tomography coronary angiography. MATERIAL AND METHODS: In this cross-sectional study, we included 567 symptomatic individuals without a history of CAD who consecutively underwent 64-slice computed tomography coronary angiography for evaluation of suspected CAD. We analyzed the prevalence of CAD depending on sex, age, symptoms and risk factors. RESULTS: A total of 8542 segments were analyzed. No evidence of CAD was observed in 225 patients (40%), nonsignificant CAD in 221 patients (39%) and significant CAD (luminal narrowing >50%) in the remaining 121 patients (21%). CAD increased with advancing age, significantly above 50 years (P < 0.05). Female patients had a higher prevalence of normal coronary arteries and males of significant CAD (P < 0.01). With the increase of risk factors, there was a significant increase of the significant disease (P < 0.01). Typical pain with respect to atypical pain had the strongest association with significant CAD (16 vs. 38%; P < 0.05). In multivariate analysis, the number of risk factors, age, male sex and typical pain remained strong predictors of significant CAD (P < 0.0001). CONCLUSION: Computed tomography coronary angiography may play an important role in risk stratification of patients with suspected CAD.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Idoso , Angiografia Coronária , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Fatores de Risco , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA