Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 42
Filtrar
1.
Respir Res ; 20(1): 207, 2019 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-31511032

RESUMO

BACKGROUND: The diagnostic yield of peripheral pulmonary lesions has significantly increased with the use of radial endobronchial ultrasound with guide sheath within the lesion. Here, we retrospectively evaluated factors leading to misdiagnosis of pulmonary malignant tumors using endobronchial ultrasound with the guide sheath within the lesion. METHODS: We assessed the final histopathological diagnosis of biopsy samples taken from 130 patients with lung malignant tumors that underwent endobronchial ultrasound with guide sheath within the lesion. RESULTS: Among 130 patients, 8 (6%) showed no definite malignant findings in biopsy samples but the presence of malignant cells (primary lung cancer 7, diffuse large B cell lymphoma 1) was subsequently confirmed by histopathological study of specimens taken by computed tomography-guided needle biopsy or surgery. Of the eight cases with diagnostic failure, the size of the biopsy sample was insufficient in five due to technical difficulties during the diagnostic procedure, and the diagnosis of malignant tumor was difficult in five cases because of extensive scarring tissue or central necrosis. CONCLUSIONS: The results of this study showed that technical difficulties and/or pathological heterogeneity of the tumor might lead to failure to diagnose lung malignant tumor in cases using endobronchial ultrasound with guide sheath within the lesion.


Assuntos
Broncoscopia/métodos , Endossonografia/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Diagnóstico Ausente , Ultrassonografia de Intervenção/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncoscopia/normas , Endossonografia/normas , Feminino , Humanos , Neoplasias Pulmonares/terapia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Ultrassonografia de Intervenção/normas
2.
BMC Pulm Med ; 17(1): 184, 2017 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-29228929

RESUMO

BACKGROUND: Transbronchial biopsy for peripheral pulmonary lesions is generally performed under X-ray fluoroscopy. Virtual bronchoscopic navigation (VBN) is a method in which virtual images of the bronchial route to the lesion are produced based on CT images obtained before VBN, and the bronchoscope is guided using these virtual images, improving the diagnostic yield of peripheral pulmonary lesions. VBN has the possibility of eliminating the need for X-ray fluoroscopy in the bronchoscopic diagnosis of peripheral lesions. To determine whether VBN can be a substitute for X-ray fluoroscopy, a randomized multicenter trial (non-inferiority trial) was performed in VBN and X-ray fluoroscopy (XRF) -assisted groups. METHODS: The non-inferiority margin in the VBN-assisted group compared with the XRF-assisted group was set at 15%. The subjects consisted of 140 patients with peripheral pulmonary lesions with a mean diameter > 3 cm. In the VBN-assisted group, the bronchoscope was guided to the lesion using a VBN system without X-ray fluoroscopy. In the XRF-assisted group, the same bronchoscope was guided to the lesion under X-ray fluoroscopy. Subsequently, in both groups, the lesion was visualized using endobronchial ultrasonography with a guide sheath (EBUS/GS), and biopsy was performed. In this serial procedure, X-ray fluoroscopy was not used in the VBNA group. RESULTS: The subjects of analysis consisted of 129 patients. The diagnostic yield was 76.9% (50/65) in the VBN-assisted group and 85.9% (55/64) in the XRF-assisted group. The difference in the diagnostic yield between the two groups was -9.0% (95% confidence interval: -22.3% ~ 4.3%). The non-inferiority of the VBN-assisted group could not be confirmed. The rate of visualizing lesions by EBUS was 95.4% (62/65) in the VBN-assisted group and 96.9% (62/64) in the XRF-assisted group, being high in both groups. CONCLUSIONS: On EBUS/GS, a bronchoscope and biopsy instruments may be guided to the lesions using VBN without X-ray fluoroscopy, but X-ray fluoroscopy is necessary to improve the accuracy of sample collection from lesions. During transbronchial biopsy for peripheral pulmonary lesions, VBN cannot be a substitute for X-ray fluoroscopy. TRIAL REGISTRATION: UMIN-CTR (UMIN000001710); registered 16 February 2009.


Assuntos
Broncoscopia/métodos , Endossonografia/métodos , Fluoroscopia/métodos , Neoplasias Pulmonares , Pulmão , Tomografia Computadorizada por Raios X/métodos , Idoso , Biópsia/métodos , Pesquisa Comparativa da Efetividade , Precisão da Medição Dimensional , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/patologia , Masculino , Pessoa de Meia-Idade
3.
Am J Respir Crit Care Med ; 192(4): 468-76, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26039792

RESUMO

RATIONALE: The combination of an ultrathin bronchoscope, navigational technology, and endobronchial ultrasound (EBUS) seems to combine the best of mutual abilities for evaluating peripheral pulmonary lesions, but ultrathin bronchoscopes that allow the use of EBUS have not been developed so far. OBJECTIVES: To compare the diagnostic yield of transbronchial biopsy under EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a novel ultrathin bronchoscope with that using a thin bronchoscope with a guide sheath for peripheral pulmonary lesions. METHODS: In four centers, patients with suspected peripheral pulmonary lesions less than or equal to 30 mm in the longest diameter were included and randomized to undergo transbronchial biopsy with EBUS, fluoroscopy, and virtual bronchoscopic navigation guidance using a 3.0-mm ultrathin bronchoscope (UTB group) or a 4.0-mm thin bronchoscope with a guide sheath (TB-GS group). MEASUREMENTS AND MAIN RESULTS: A total of 310 patients were enrolled and randomized, among whom 305 patients (150, UTB group; 155, TB-GS group) were analyzed. The ultrathin bronchoscope could reach more distal bronchi than the thin bronchoscope (median fifth- vs. fourth-generation bronchi; P < 0.001). Diagnostic histologic specimens were obtained in 74% (42% for benign and 81% for malignant lesions) of the UTB group and 59% (36% for benign and 70% for malignant lesions) of the TB-GS group (P = 0.044, Mantel-Haenszel test). Complications including pneumothorax, bleeding, chest pain, and pneumonia occurred in 3% and 5% in the respective groups. CONCLUSIONS: The diagnostic yield of the UTB method is higher than that of the TB-GS method. Clinical trial registered with www.umin.ac.jp/ctr/ (UMIN 000003177).


Assuntos
Broncoscópios , Broncoscopia/instrumentação , Endossonografia/instrumentação , Biópsia Guiada por Imagem/instrumentação , Neoplasias Pulmonares/patologia , Imagem Multimodal/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Fluoroscopia/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade
4.
Respiration ; 88(5): 430-40, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25402610

RESUMO

Virtual bronchoscopic navigation (VBN) is a method in which the bronchoscope is guided on the bronchial route to a peripheral lesion using virtual bronchoscopic images. In reports on VBN for peripheral pulmonary lesions searched in PubMed as of November 2013, the diagnostic yield by ultrathin bronchoscopy in combination with computed tomography and VBN was within the range of 65.4-81.6%. Using endobronchial ultrasonography with a guide sheath (EBUS-GS) and VBN, it was between 63.3 and 84.4%, and using X-ray fluoroscopy and VBN, it was between 62.5 and 78.7%. The overall diagnostic yield was 73.8% [95% confidence interval (CI) 70.9-76.8%] and that for lesions ≤ 2 cm was 67.4% (95% CI 63.3-71.5%). These values indicate high diagnostic rates. In randomized comparative trials, the combination of VBN with EBUS-GS improved the diagnostic yield and shortened the examination time. The diagnostic yields for lesions in the right upper lobe, those invisible on posterior-anterior radiographs and those located in the peripheral third of the lung field were improved by VBN on ultrathin bronchoscopy in combination with X-ray fluoroscopy. The usefulness of VBN was also found on meta-analysis. Taken together, VBN is a promising navigational bronchoscopy method as it requires no specific training, has a low overall complication rate of 1.0% (95% CI 0.2-1.8%) and does not directly induce or cause severe complications. To maximize the full potential of VBN and promote its use, investigation of cases in which it is useful, determination of the optimum combination of procedures, a cost/benefit analysis and advancement of the VBN system are warranted.


Assuntos
Broncoscopia , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/cirurgia , Cirurgia Assistida por Computador , Humanos , Biópsia Guiada por Imagem , Imageamento Tridimensional , Imagem Multimodal , Tomografia Computadorizada Espiral
5.
Am J Respir Crit Care Med ; 188(3): 327-33, 2013 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-23600452

RESUMO

RATIONALE: In bronchoscopy, an ultrathin bronchoscope can be advanced to more peripheral bronchi. Because virtual bronchoscopic navigation (VBN) is a method to guide a bronchoscope under direct observation using VB images, VBN may be particularly useful when combined with ultrathin bronchoscopy. OBJECTIVES: This prospective multicenter study evaluated the value of VBN-assisted ultrathin bronchoscopy for diagnosing peripheral pulmonary lesions. METHODS: We randomly assigned 350 patients with peripheral pulmonary lesions (diameter, ≤30 mm) to VBN-assisted or non-VBN-assisted groups. An ultrathin bronchoscope (outer diameter, 2.8 mm) was introduced to the target bronchus using a VBN system in the VBN-assisted group, whereas only computed tomography axial images were referred to in the non-VBN-assisted group. Specimen sampling sites were verified using X-ray fluoroscopy. MEASUREMENTS AND MAIN RESULTS: Subjects for analysis included 334 patients. There was no significant difference in the diagnostic yield between the VBN-assisted group (67.1%) and the non-VBN-assisted group (59.9%; P = 0.173). The subgroup analysis showed that the diagnostic yield was significantly higher in the VBN-assisted group than in the non-VBN-assisted group for right upper lobe lesions (81.3% vs. 53.2%; P = 0.004); lesions invisible on posterior-anterior radiographs (63.2% vs. 40.5%; P = 0.043); and lesions in the peripheral third of the lung field (64.7% vs. 52.1%; P = 0.047). CONCLUSIONS: VBN-assisted ultrathin bronchoscopy does not improve the diagnostic yield for peripheral pulmonary lesions. However, the method improves the diagnostic yield for lesions in the subcategories (right upper lobe, invisible, peripheral third), warranting further study. Clinical trial registered with www.umin.ac.jp/ctr/ (UMIN 000001536).


Assuntos
Broncoscópios , Broncoscopia/métodos , Neoplasias Pulmonares/diagnóstico , Miniaturização/instrumentação , Nódulo Pulmonar Solitário/diagnóstico , Interface Usuário-Computador , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia/métodos , Diagnóstico Diferencial , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
6.
Respir Res ; 14: 50, 2013 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-23663438

RESUMO

BACKGROUND: With the recent widespread use of endobronchial ultrasound-guided transbronchial needle aspiration (EBUS-TBNA), there have been occasional reports on complications associated with its use. Previous reviews on EBUS-TBNA have been limited to studies by skilled operators, thus the results may not always be applicable to recent clinical practice. To assess the safety of EBUS-TBNA for the staging and diagnosis of lung cancer in Japan, a nationwide survey on its current usage status and complications associated with its use was conducted by the Japan Society for Respiratory Endoscopy (JSRE). METHODS: A questionnaire about EBUS-TBNA performed between January 2011 and June 2012 was mailed to 520 JSRE-accredited facilities. RESULTS: Responses were obtained from 455 facilities (87.5%). During the study period, EBUS-TBNA was performed in 7,345 cases in 210 facilities (46.2%) using a convex probe ultrasound bronchoscope, for 6,836 mediastinal and hilar lesions and 275 lung parenchymal lesions. Ninety complications occurred in 32 facilities. The complication rate was 1.23% (95% confidence interval, 0.97%-1.48%), with hemorrhage being the most frequent complication (50 cases, 0.68%). Infectious complications developed in 14 cases (0.19%) (Mediastinitis, 7; pneumonia, 4; pericarditis, 1; cyst infection, 1; and sepsis, 1). Pneumothorax developed in 2 cases (0.03%), one of which required tube drainage. Regarding the outcome of the cases with complications, prolonged hospitalization was observed in 14 cases, life-threatening conditions in 4, and death in 1 (severe cerebral infarction) (mortality rate, 0.01%). Breakage of the ultrasound bronchoscope occurred in 98 cases (1.33%) in 67 facilities (31.9%), and that of the puncture needle in 15 cases (0.20%) in 8 facilities (3.8%). CONCLUSIONS: Although the complication rate associated with EBUS-TBNA was found to be low, severe complications, including infectious complications, were observed, and the incidence of device breakage was high. Since the use of EBUS-TBNA is rapidly expanding in Japan, an educational program for its safe performance should be immediately established.


Assuntos
Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/mortalidade , Hemorragia/mortalidade , Neoplasias Pulmonares/mortalidade , Neoplasias Pulmonares/patologia , Pneumotórax/mortalidade , Complicações Pós-Operatórias/mortalidade , Infecção da Ferida Cirúrgica/mortalidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Comorbidade , Coleta de Dados , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/estatística & dados numéricos , Feminino , Humanos , Incidência , Japão/epidemiologia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Taxa de Sobrevida
8.
Respirology ; 18(2): 284-90, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23016914

RESUMO

BACKGROUND AND OBJECTIVE: To ensure the safety of bronchoscopic practice, the Japan Society for Respiratory Endoscopy conducted a national survey to investigate the current state of procedure for this technique. METHODS: A questionnaire survey about procedures carried out during the whole of the year 2010 was mailed to 538 facilities accredited by the society. RESULTS: Responses were obtained from 511 facilities (95.0%). Rigid bronchoscopes were used in only 18.5% of the facilities, while mobile/thin bronchoscopes were used in ≥ 50%, and fluoroscopy systems were used in 99.8%. Biopsies were performed after discontinuation of therapy in patients receiving antiplatelet drugs and anticoagulants in 96.7% and 97.4% of the facilities, respectively. Atropine was administered for premedication in 67.5% of the facilities, a decrease from previous surveys. Intravenous sedation was given in 36.1% of the facilities. In 21.9% of these, the procedure was conducted in the outpatient clinic for ≥ 70% of patients. A bronchoscope was orally inserted in ≥ 70% of patients in 95.7% of the facilities. Intravenous access was maintained during the examination in 92.5% of the facilities, oxygen saturation was monitored during examinations in 99.0%, oxygen was administered in 97.6% and resuscitation equipment was available in 96%. In 98.6% of the facilities, bronchoscopes were disinfected using an automatic washing machine, with glutaraldehyde used in 42.2%. CONCLUSIONS: Japan-specific characteristics of bronchoscopic practice were identified. Whether procedures used in Japan meet international guidelines with respect to safety should be monitored continuously. In addition, a Japanese evidence-based consensus is needed.


Assuntos
Broncoscopia/métodos , Broncoscopia/estatística & dados numéricos , Coleta de Dados , Padrões de Prática Médica/estatística & dados numéricos , Administração Intravenosa , Biópsia , Broncoscopia/efeitos adversos , Humanos , Hipnóticos e Sedativos/administração & dosagem , Japão , Pulmão/patologia , Estudos Retrospectivos , Inquéritos e Questionários
9.
Int J Emerg Med ; 16(1): 23, 2023 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-37024788

RESUMO

BACKGROUND: This study aimed to understand whether the one-time chair stand test (CS-1) is useful for predicting the severity of coronavirus disease (COVID-19) in 101 patients admitted to the hospital with acute respiratory failure. METHODS: This single-centered, prospective observational cohort study enrolled 101 critically ill adult patients hospitalized with COVID-19 who underwent the CS-1 as a dynamic evaluation tool in clinical practice between late April 2020 and October 2021. Data on demographic characteristics, symptoms, laboratory values, computed tomography findings, and clinical course after admission were collected. Furthermore, the data was compared, and the association between the intubation and non-intubation groups was determined. We also calculated the cutoff point, area under the curve (AUC), and 95% confidence interval (CI) of the change in oxygen saturation (ΔSpO2) during the CS-1. RESULTS: Thirty-three out of 101 patients (33%) were intubated during hospitalization. There was no significant difference in the resting SpO2 (93.3% versus 95.2%, P = 0.22), but there was a significant difference in ΔSpO2 during the CS-1 between the intubation and non-intubation groups (10.8% versus 5.5%, P < 0.01). In addition, there was a significant correlation between hospitalization and ΔSpO2 during the CS-1 (ρ = 0.60, P < 0.01). The generated cutoff point was calculated as 9.5% (AUC = 0.94, 95% CI = 0.88-1.00). CONCLUSION: For COVID-19 patients with acute respiratory failure, the CS-1 performed on admission was useful for predicting the severity of COVID-19. Furthermore, the CS-1 can be utilized as a remote and simple evaluation parameter. Thus, it could have potential clinical applications in the future.

10.
Intern Med ; 62(23): 3519-3523, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37779072

RESUMO

The prognosis of patients with post-coronavirus disease 2019 (COVID-19) interstitial lung disease remains unclear. We herein report an autopsy case in which serial progression after the onset of post-COVID-19 interstitial lung disease resulted in an acute exacerbation, leading to a fatal outcome. Autopsy findings included hyaline membrane formation/interstitial inflammatory cell infiltration, suggestive of acute lesions, and severe regional fibrosis, indicating a preexisting chronic condition. In the present case, we histopathologically confirmed the acute exacerbation of post-COVID-19 interstitial lung disease.


Assuntos
COVID-19 , Doenças Pulmonares Intersticiais , Humanos , COVID-19/complicações , Autopsia , Doenças Pulmonares Intersticiais/complicações , Doenças Pulmonares Intersticiais/patologia
11.
Sci Rep ; 13(1): 14724, 2023 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-37679360

RESUMO

Bronchoscopy with radial-probe endobronchial ultrasound, a guide sheath, and electromagnetic navigation can improve the diagnostic yield of peripheral lung nodules. However, the suitability of specimens for genetic analysis remains unsatisfactory. We hypothesized that a transbronchial biopsy performed after closely approaching the bronchoscope tip to the lesion might provide more suitable specimens for genetic analysis. We enrolled 155 patients with peripheral pulmonary lesions who underwent bronchoscopy with a thin or ultrathin bronchoscope. Bronchoscopy was performed using virtual bronchoscopic navigation and radial-probe endobronchial ultrasound with a guide sheath. The bronchoscope tip was placed closer to the lesion during bronchoscopy to collect larger specimens with higher malignant cell content. The patients who underwent a close-to-lesion biopsy had higher rates of overall diagnostic yield, histopathological diagnostic yield, and specimen quality for genetic testing than those who did not. The significant determinants of the specimen's suitability were the close-to-lesion approach, within-the-lesion image, the use of standard 1.9-mm-forceps, and the number of cancer-cell-positive specimens. The significant predictors of the specimen's suitability for genetic analysis were close-to-lesion biopsy and the number of malignant cell-positive tissue samples. This study demonstrates that the close-to-lesion transbronchial biopsy significantly improves the suitability of bronchoscopic specimens for genetic analysis.


Assuntos
Broncoscopia , Testes Genéticos , Humanos , Masculino , Biópsia , Endossonografia , Prepúcio do Pênis
12.
Respirology ; 17(3): 478-85, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22222022

RESUMO

BACKGROUND AND OBJECTIVE: In order to survey the current status of the use and complications associated with respiratory endoscopy, the Japan Society for Respiratory Endoscopy conducted a nationwide postal questionnaire survey. METHODS: The survey was mailed to all 538 facilities certified by the society. The subjects were patients who underwent respiratory endoscopy in 2010. The numbers of procedures, and associated complications and deaths were investigated according to lesion and procedure using a specific inventory. RESULTS: The inventory was completed by 483 facilities (89.8%). The total number of diagnostic flexible bronchoscopy procedures performed was 103 978, and four patients died (0.004%). The complication rate according to lesion ranged from 0.51% to 2.06%, with the highest rate being observed in patients with diffuse lesions. The complication rate according to procedure ranged from 0.17% to 1.93%, with the highest rate being observed in patients who underwent forceps biopsy. The complication rate after forceps biopsy of solitary peripheral pulmonary lesions was 1.79% (haemorrhage: 0.73%, pneumothorax: 0.63%), and that after endobronchial ultrasound-guided transbronchial needle aspiration of hilar and/or mediastinal lymph node lesions was 0.46%. Therapeutic bronchoscopy was performed in 3020 patients; one patient (0.03%) died due to haemorrhage induced by insertion of an expandable metallic stent. The complication rate according to procedure was highest for foreign body removal (2.2%). Medical pleuroscopy was performed in 1563 patients. The highest complication rate was for biopsy without electrocautery (1.86%). A total of 228 facilities (47.2%) experienced breakage of bronchoscopes and/or devices. CONCLUSIONS: Respiratory endoscopy was performed safely, but education regarding complications caused by new techniques is necessary.


Assuntos
Broncoscopia/efeitos adversos , Broncoscopia/mortalidade , Causas de Morte , Broncoscopia/instrumentação , Feminino , Pesquisas sobre Atenção à Saúde , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Japão/epidemiologia , Masculino , Estudos Retrospectivos , Inquéritos e Questionários
13.
Thorax ; 66(12): 1072-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21749984

RESUMO

BACKGROUND: Bronchoscopy using endobronchial ultrasound (EBUS) can help to diagnose small peripheral pulmonary lesions. However, although biopsy sites can be confirmed, a bronchoscope cannot be guided in EBUS. Virtual bronchoscopic navigation (VBN) can guide a bronchoscope with virtual images, but its value has not been confirmed. METHODS: This prospective multicentre study examines the value of VBN-assisted EBUS for diagnosing small peripheral pulmonary lesions. 199 patients with small peripheral pulmonary lesions (diameter ≤30 mm) were randomly assigned to VBN-assisted (VBNA) or non-VBN-assisted (NVBNA) groups. A bronchoscope was introduced into the target bronchus of the VBNA group using the VBN system. Sites of specimen sampling were verified using EBUS with a guide sheath under fluoroscopy. RESULTS: The diagnostic yield was higher for the VBNA than for the NVBNA group (80.4% vs 67.0%; p = 0.032). The duration of the examination and time elapsed until the start of sample collection were reduced in the VBNA compared with the NVBNA group (median (range), 24.0 (8.7-47.0) vs 26.2 (11.6-58.6) min, p = 0.016) and 8.1 (2.8-39.2) vs 9.8 (2.3-42.3) min, p = 0.045, respectively). The only adverse event was mild pneumothorax in a patient from the NVBNA group. CONCLUSIONS: The diagnostic yield for small peripheral pulmonary lesions is increased when VBN is combined with EBUS. Clinical trial number UMIN000000569.


Assuntos
Endossonografia/métodos , Neoplasias Pulmonares/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Broncoscópios , Broncoscopia/métodos , Distribuição de Qui-Quadrado , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Tomografia Computadorizada por Raios X
14.
Intern Med ; 60(4): 595-599, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-32999226

RESUMO

A 68-year-old man visited a physician with a chief complaint of difficulty breathing. Right pleural effusion was noted, and he was referred to our department for a close examination and treatment. Thoracoscopy was performed under local anesthesia, and pleural dissemination of lung adenocarcinoma was noted, so a chest drain was placed. Since poor right lung inflation persisted and whole right lung torsion was observed on computed tomography, thoracoscopy-assisted thoracotomic reduction of lung torsion was performed. In this patient, the right middle lobe and anterior chest wall were adhered, suggesting that whole right lung torsion occurred when atelectasis was formed due to pleural effusion.


Assuntos
Adenocarcinoma de Pulmão , Neoplasias Pulmonares , Derrame Pleural , Adenocarcinoma de Pulmão/complicações , Adenocarcinoma de Pulmão/diagnóstico por imagem , Idoso , Humanos , Pulmão , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Derrame Pleural/diagnóstico por imagem , Derrame Pleural/etiologia , Anormalidade Torcional/complicações , Anormalidade Torcional/diagnóstico por imagem , Anormalidade Torcional/cirurgia
15.
Intern Med ; 60(4): 605-609, 2021 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-32999228

RESUMO

The patient was a 75-year-old man who developed polyopia and exophthalmos. Chest computed tomography (CT) revealed a mass in the left upper lobe. A CT-guided biopsy suggested lung adenocarcinoma. He was treated by neoadjuvant chemotherapy followed by left upper lobectomy. He was diagnosed with stage IIB pleomorphic carcinoma postoperatively. Preoperative head magnetic resonance imaging revealed exophthalmos and bilateral swelling of the extraocular muscles. The thyroid function of the patient was within the normal range, and he tested negative for autoantibodies. As his symptoms and swelling of the extraocular muscles improved postoperatively, he was diagnosed with paraneoplastic syndrome.


Assuntos
Carcinoma , Exoftalmia , Neoplasias Pulmonares , Síndromes Paraneoplásicas , Idoso , Diplopia , Exoftalmia/diagnóstico , Exoftalmia/etiologia , Humanos , Neoplasias Pulmonares/complicações , Neoplasias Pulmonares/diagnóstico , Masculino , Síndromes Paraneoplásicas/diagnóstico , Síndromes Paraneoplásicas/etiologia , Tomografia Computadorizada por Raios X
17.
J Bronchology Interv Pulmonol ; 27(4): 253-258, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32282445

RESUMO

BACKGROUND: The Japan Society for Respiratory Endoscopy performed a nationwide survey to evaluate the current status and complications of bronchoscopy. Data on deaths due to bronchoscopy, complications after bronchoscopy, and particularly, complications of forceps biopsy were surveyed. METHODS: The survey form was mailed to 532 facilities accredited by the society. The numbers of procedures, complications, and deaths were investigated. RESULTS: The response rate was 79.1% (421 facilities). Deaths attributable to diagnostic bronchoscopy occurred in 11 (0.011%) of 98,497 cases.In regards to forceps biopsy, the guide sheath method was applied in 23,916 cases and the conventional method in 31,419 cases was done with conventional method. Complications of forceps biopsy developed in 1019 cases in total, with an incidence rate of 1.84%. The most frequent complication was pneumothorax (0.70%), followed by pneumonia/pleurisy (0.46%) and hemorrhage (0.45%). The incidence of hemorrhagic complication was significantly lower in the guide sheath group than in the non-guide sheath group (0.29% vs. 0.58%; P<0.001). The overall incidence of complications (1.63% vs. 2.00%; P=0.002) and the mortality rate (0% vs. 0.02%; P=0.04) were significantly lower in the guide sheath group. CONCLUSION: The incidence of hemorrhagic complications in forceps biopsy of peripheral pulmonary lesions was lower when the guide sheath method was applied. It is necessary to increase the awareness for safety control in diagnostic bronchoscopy for new procedures.


Assuntos
Broncoscopia/efeitos adversos , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico/instrumentação , Hemorragia/epidemiologia , Biópsia Guiada por Imagem/efeitos adversos , Neoplasias Pulmonares/patologia , Instrumentos Cirúrgicos/efeitos adversos , Broncoscopia/métodos , Broncoscopia/mortalidade , Broncoscopia/estatística & dados numéricos , Endoscopia , Hemorragia/etiologia , Hemorragia/mortalidade , Humanos , Incidência , Japão , Mortalidade/tendências , Pleurisia/epidemiologia , Pleurisia/etiologia , Pneumonia/epidemiologia , Pneumonia/etiologia , Pneumotórax/epidemiologia , Pneumotórax/etiologia , Estudos Retrospectivos , Sociedades Médicas/organização & administração , Inquéritos e Questionários/estatística & dados numéricos
18.
Front Med (Lausanne) ; 7: 588048, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33385003

RESUMO

There are cases of peripheral lung nodules that are difficult to approach despite using ancillary diagnostic devices during multimodal bronchoscopy. The use of ultrathin bronchoscopes has shown superiority over standard thin bronchoscopes. We retrospectively evaluated whether substitution of the thin-bronchoscope by the ultrathin device during multimodal bronchoscopy improves lesion ultrasound visualization and diagnostic yield in patients with difficult-to-approach pulmonary lesions. The study comprised 44 out of 338 patients that underwent multimodal bronchoscopy at Matsusaka Municipal Hospital. The thin-bronchoscope with an external diameter of 4 mm was substituted by the ultrathin-bronchoscope with an external diameter of 3 mm when the radial endobronchial ultrasound showed that the probe position was not within the target lesion. The median diameter of the pulmonary tumors was 17.5 mm (range: 6.0-5.2.0 mm). The endobronchial ultrasound showed the probe's position adjacent to the lesion in 12 cases and no visible lesion in 32 cases using a thin-bronchoscope. However, the endobronchial ultrasound views changed from adjacent to the lesion to within the lesion in nine cases, from no visible lesion to within the lesion in 17 cases, and from no visible lesion to adjacent to the lesion in nine cases after bronchoscope substitution. After substitution, the diagnostic yield was 80.8% in cases with the radial probe within the target lesion, 72.7% in cases with the probe adjacent to the target lesion, and 0% in cases with no visible lesion. The overall diagnostic yield was 65.9% after bronchoscope substitution. The substitution of the thin bronchoscope by the ultrathin device on a need basis improves the position of the radial endobronchial ultrasound probe and diagnostic yield of pulmonary lesions during multimodal diagnostic bronchoscopy.

19.
Respiration ; 78(4): 423-31, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19672051

RESUMO

BACKGROUND: Mediastinal lymph node staging (N-staging) is essential to optimize the treatment in non-small cell lung cancer (NSCLC). Transesophageal endoscopic ultrasonography-guided fine needle aspiration (EUS-FNA) has recently been introduced as a complementary method. However, in most reports, EUS-FNA has been performed in patients who have demonstrated enlarged lymph nodes (LNs) on CT findings. The yield of EUS/EUS-FNA in patients without enlarged mediastinal LNs by CT has so far only been evaluated in a few reports. AIMS: Our aim was to compare the diagnostic accuracy of CT and EUS with or without EUS-FNA (EUS/EUS-FNA) prospectively, for N-stage in all patients with potentially resectable NSCLC, including patients with and without mediastinal LN enlargement based on CT findings. METHODS: Eighty consecutive patients with potentially resectable NSCLC based on CT findings were enrolled in this prospective comparative study, and underwent EUS/EUS-FNA. RESULTS: Pathological N-stage was established in 78 patients, while in another 2 cases, malignant pleural effusion was proven by EUS-FNA, and we avoided further N-staging. In the 78 patients, the prevalence of malignant mediastinal LNs was 21%. The accuracy of EUS/EUS-FNA (91%) was significantly higher than that of CT (71%). The negative predictive value of EUS/EUS-FNA was 90%. In addition, EUS-FNA identified 2 patients as N3 disease in 56 patients without mediastinal LN involvement on CT. CONCLUSIONS: EUS/EUS-FNA gave more accurate N-staging in patients with possibly resectable NSCLC than CT, and is thus considered to be useful to determine the optimal treatment strategy.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Aspiração por Agulha Fina Guiada por Ultrassom Endoscópico , Neoplasias Pulmonares/patologia , Linfonodos/patologia , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Metástase Linfática/patologia , Masculino , Mediastino , Pessoa de Meia-Idade , Estudos Prospectivos , Tomografia Computadorizada por Raios X
20.
Chest ; 156(5): 954-964, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31356810

RESUMO

BACKGROUND: When evaluating peripheral pulmonary lesions, a 3.0-mm ultrathin bronchoscope (UTB) with a 1.7-mm working channel is advantageous regarding good access to the peripheral airway, whereas a 4.0-mm thin bronchoscope provides a larger 2.0-mm working channel, which allows the use of various instruments including a guide sheath (GS), larger forceps, and an aspiration needle. This study compared multimodal bronchoscopy using a UTB and a thin bronchoscope with multiple sampling methods for the diagnosis of peripheral pulmonary lesions. METHODS: Patients with peripheral pulmonary lesions ≤ 30 mm in diameter were recruited and randomized to undergo endobronchial ultrasonography, virtual bronchoscopy, and fluoroscopy-guided bronchoscopy using a 3.0-mm UTB (UTB group) or a 4.0-mm thin bronchoscope (thin bronchoscope group). In the thin bronchoscope group, the use of small forceps with a GS or standard forceps without the GS was permitted. In addition, needle aspiration was performed for lesions into which an ultrasound probe could not be inserted. RESULTS: A total of 360 patients were enrolled, and 356 were included in the analyses (median largest lesional diameter, 19 mm). The overall diagnostic yield was significantly higher in the UTB group than in the thin bronchoscope group (70.1% vs 58.7%, respectively; P = .027). The procedure duration was significantly shorter in the UTB group (median, 24.8 vs 26.8 min, respectively; P = .008). The complication rates were 2.8% and 4.5%, respectively (P = .574). CONCLUSIONS: Multimodal bronchoscopy using a UTB afforded a higher diagnostic yield than that using a thin bronchoscope in the diagnosis of small peripheral pulmonary lesions. TRIAL REGISTRY: UMIN Clinical Trials Registry; No.: UMIN000010133; URL: https://www.umin.ac.jp/ctr/.


Assuntos
Broncoscópios , Broncoscopia/métodos , Neoplasias Pulmonares/diagnóstico , Pulmão/diagnóstico por imagem , Nódulo Pulmonar Solitário/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Endossonografia , Desenho de Equipamento , Feminino , Humanos , Biópsia Guiada por Imagem/métodos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA