RESUMO
STUDY QUESTION: Do embryologists from different European countries agree on embryo disposition decisions ('use' or 'discard') about Day 7 (>144 h post-insemination) and/or low-quality blastocysts (LQB; Assuntos
Inteligência Artificial
, Blastocisto
, Feminino
, Humanos
, Aneuploidia
, Blastocisto/fisiologia
, Transferência Embrionária/métodos
, Idade Materna
, Estudos Retrospectivos
, Masculino
RESUMO
An external quality-control programme for morphology-based embryo quality assessment, incorporating a standardized embryo grading scheme, was evaluated over a period of 5 years to determine levels of inter-observer reliability and agreement between practising clinical embryologists at IVF centres and the opinions of a panel of experts. Following Guidelines for Reporting Reliability and Agreement Studies, the Gwet index and proportion of positive (Ppos) and negative agreement were calculated. For embryo morphology assessment, a substantial degree of reliability was measured between the centres and the panel of experts (Gwet index: 0.76; 95% CI 0.70 to 0.84). The agreement was higher for good- versus poor-quality embryos. When multinucleation or vacuoles were observed, low levels of reliability were obtained (Ppos: 0.56 and 0.43, respectively). In blastocysts, the characteristic that presented the largest discrepancy was that related to the inner cell mass. In decisions about the final disposition of the embryo, reliability between centre and the panel of experts was moderate (Gwet index: 0.51; 95% CI 0.41 to 0.60). In conclusion, the ability of clinical embryologists to evaluate the presence of multinucleation and vacuoles in the early cleavage embryo, and to determine the category of the inner cell mass in blastocysts, needs to be improved.
Assuntos
Blastocisto/ultraestrutura , Embrião de Mamíferos/ultraestrutura , Desenvolvimento Embrionário , Processamento de Imagem Assistida por Computador/métodos , Controle de Qualidade , Feminino , Humanos , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: To assess whether high body mass index (BMI) in either oocyte donors or recipients is associated with poorer outcomes after the first single blastocyst transfer. DESIGN: Retrospective study including 1,394 first blastocyst single embryo transfers (SETs) conducted by 1,394 recipients during oocyte donation cycles with the gametes retrieved from 1,394 women (January 2019-July 2021). Four BMI clusters were defined for both donors and recipients (underweight: <18.5 kg; normal weight: 18.5-24.9 kg; overweight: 25-29.9 kg; and obese: ≥30 kg). SETTING: Network of private IVF centers. PATIENTS: A total of 1,394 recipients aged 42.4 ± 4.0 and with a BMI of 23.2 ± 3.8 kg/m2, and 1,394 donors aged 26.1 ± 4.2 and with a BMI of 21.9 ± 2.5 kg/m2. INTERVENTION: All oocytes were vitrified at 2 egg banks and warmed at 8 in vitro fertilization clinics that were part of the same network. Intracytoplasmic sperm injection, blastocyst culture, and either fresh or vitrified-warmed SETs were conducted. Putative confounders were investigated, and the data were adjusted through regression analyses. MAIN OUTCOME MEASURES: The primary outcome was the live birth rate (LBR) per SET according to donors' and/or recipients' BMI. The main secondary outcome was the miscarriage rate (<22 gestational weeks) per clinical pregnancy. RESULTS: The LBR per blastocyst SET showed no significant association with donors' BMI. Regarding recipients' BMI, instead, the multivariate odds ratio was significant in obese vs. normal-weight recipients (0.58, 95% confidence interval, 0.37-0.91). The miscarriage rate per clinical pregnancy was also significantly associated with recipients' obesity, with a multivariate odds ratio of 2.31 (95% confidence interval, 1.18-4.51) vs. normal-weight patients. A generalized additive model method was used to represent the relationship between predicted LBR or miscarriage rates and donors' or recipients' BMI; it pictured a scenario where the former outcome moderately but continuously decreases with increasing recipients' BMI to then sharply decline in the BMI range of 25-35 kg/m2. The miscarriage rate, instead, increases almost linearly with respect to both donors' and recipients' increasing BMI. CONCLUSION: Obesity mostly affects the uterus, especially because of higher miscarriage rates. Yet, poorer outcomes can be appreciated already with a BMI of 25 kg/m2 in both oocyte donors and recipients. Finer markers of nutritional homeostasis are therefore desirable; recipients should be counseled about poorer expected outcomes in cases of overweight and obesity; and oocyte banks should avoid assigning oocytes from overweight donors to overweight and obese recipients.
Assuntos
Aborto Espontâneo , Gravidez , Humanos , Masculino , Feminino , Índice de Massa Corporal , Aborto Espontâneo/epidemiologia , Aborto Espontâneo/etiologia , Estudos Retrospectivos , Taxa de Gravidez , Sobrepeso/diagnóstico , Sobrepeso/epidemiologia , Sobrepeso/terapia , Sêmen , Transferência Embrionária/efeitos adversos , Fertilização in vitro/efeitos adversos , Útero , Obesidade/diagnóstico , Obesidade/epidemiologia , Obesidade/terapia , Oócitos , BlastocistoRESUMO
The aim of this study is to determine inter-laboratory variability on embryo assessment using time-lapse platform and conventional morphological assessment. This study compares the data obtained from a pilot study of external quality control (EQC) of time lapse, performed in 2014, with the classical EQC of the Spanish Society for the Study of Reproductive Biology (ASEBIR) performed in 2013 and 2014. In total, 24 laboratories (8 using EmbryoScope™, 15 using Primo Vision™ and one with both platforms) took part in the pilot study. The clinics that used EmbryoScope™ analysed 31 embryos and those using Primo Vision™ analysed 35. The classical EQC was implemented by 39 clinics, based on an analysis of 25 embryos per year. Both groups were required to evaluate various qualitative morphological variables (cell fragmentation, the presence of vacuoles, blastomere asymmetry and multinucleation), to classify the embryos in accordance with ASEBIR criteria and to stipulate the clinical decision taken. In the EQC time-lapse pilot study, the groups were asked to determine, as well as the above characteristics, the embryo development times, the number, opposition and size of pronuclei, the direct division of 1 into 3 cells and/or of 3 into 5 cells and false divisions. The degree of agreement was determined by calculating the intra-class correlation coefficients and the coefficient of variation for the quantitative variables and the Gwet index for the qualitative variables. For both EmbryoScope™ and Primo Vision™, two periods of greater inter-laboratory variability were observed in the times of embryo development events. One peak of variability was recorded among the laboratories addressing the first embryo events (extrusion of the second polar body and the appearance of pronuclei); the second peak took place between the times corresponding to the 8-cell and morula stages. In most of the qualitative variables analysed regarding embryo development, there was almost-perfect inter-laboratory agreement among conventional morphological assessment (CMA), EmbryoScope™ and Primo Vision™, except for false divisions, vacuoles and asymmetry (users of all methods) and multinucleation (users of Primo Vision™), where the degree of agreement was lower. The inter-laboratory agreement on embryo classification according to the ASEBIR criteria was moderate-substantial (Gwet 0.41-0.80) for the laboratories using CMA and EmbryoScope™, and fair-moderate (Gwet 0.21-0.60) for those using Primo Vision™. The inter-laboratory agreement for clinical decision was moderate (Gwet 0.41-0.60) on day 5 for CMA users and almost perfect (Gwet 0.81-1) for time-lapse users. In conclusion, time-lapse technology does not improve inter-laboratory agreement on embryo classification or the analysis of each morphological variable. Moreover, depending on the time-lapse platform used, inter-laboratory agreement may be lower than that obtained by CMA. However, inter-laboratory agreement on clinical decisions is improved with the use of time lapse, regardless of the platform used.