1.
Interv Neuroradiol ; 28(3): 302-310, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34515551

RESUMO

OBJECTIVE: This study aims to compare the efficacy, safety, and long-term outcomes of two flow diverters, i.e., pipeline embolization device and flow re-direction endoluminal device, in the treatment of distal carotid aneurysms. METHODS: A total of 138 patients with 175 aneurysms were included from February 2012 to September 2019. Ninety-nine aneurysms were treated with flow re-direction endoluminal device and 76 with pipeline embolization device. Angiographic follow-ups were at the 6th, 12th, 24th, 36th, and 60th months; the O'Kelly-Marotta grading scale was used to assess aneurysms occlusion. Outcomes of two devices were compared; possible associations regarding patient characteristics, aneurysm properties, treatment details, and adverse events were evaluated. RESULTS: The mean follow-up period was 33 months, with 10 patients lost to follow-up. Occlusion rates at the 6th and 12th months and during the last follow-up were similar for flow re-direction endoluminal device (81%, 84%, and 90%) and pipeline embolization device (82%, 85%, and 93%). Occlusion rates were also similar after stand-alone use without coiling. There was no significant difference regarding adverse event rates with a 10.9% overall complication rate, 3.6% mortality, and 0.7% permanent morbidity. All the mortality and morbidity were related to hemorrhagic complications. Device deployment failure was observed with five flow re-direction endoluminal devices and two pipeline embolization devices, whereas two severe in-stent stenoses occurred with each device. CONCLUSIONS: Both flow re-direction endoluminal device and pipeline embolization device are feasible and effective in flow diversion of distal internal carotid artery aneurysms, with similar adverse events rates and aneurysm occlusion success. Aneurysm occlusion rates increase with time, while the presence of an integrated branch significantly decreases treatment success.


Assuntos
Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Prótese Vascular , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/etiologia , Aneurisma Intracraniano/terapia , Estudos Retrospectivos , Stents/efeitos adversos , Resultado do Tratamento
2.
Curr Med Imaging ; 17(7): 897-903, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33966622

RESUMO

BACKGROUND: Greater Saphenous Vein (GSV) courses within saphenous compartment, an adipose-filled space bound by fasciae provides structural support. Ultrasound Shear-Wave Elastography (SWE) provides objective and quantitative data on tissue shear elasticity modulus. OBJECTIVE: This study aims to analyze possible associations between early stage GSV insufficiency and saphenous intracompartmental SWE measurements. METHODS: Two-hundred consecutive patients, ages 22 to 81 (mean=44.3) years, with venous insufficiency symptoms underwent Doppler and SWE examinations. Patients had no visible or palpable sign of venous disease or had telangiectasia and reticular veins only. Analyses regarding patient age, gender, presence of venous insufficiency of GSV proper and intracompartmental connective tissue elasticity were performed. RESULTS: Ninety-six patients had Doppler evidence for either bilateral or unilateral insufficiency of GSV proper at mid-thigh level. Intracompartmental elasticity of patients with venous insufficiency (mean=4.36±2.24 kilopascals; range 1.55 to 10.44 kPa) did not differ significantly from those with normal veins (mean=4.82±2.61 kPa; range 2.20 to 12.65 kPa) (p=0.231). No threshold for predicting the presence of venous insufficiency could be determined. Neither were there any correlations between age, gender and intracompartmental elasticity. In patients with unilateral insufficiency, however, elastography values around insufficient veins were significantly lower compared to contralateral normal GSV (p<0.001). CONCLUSION: Many intrinsic and patient factors affect intracompartmental connective tissue elastography measurements; thus, cut-off values obtained from specific populations have limited generalizability. Nevertheless, statistically significant intrapatient differences of intracompartmental elasticity among diseased and normal saphenous veins indicate that lack of elastic support from surrounding connective tissues contributes to venous insufficiency in early stages.


Assuntos
Técnicas de Imagem por Elasticidade , Insuficiência Venosa , Adulto , Idoso , Idoso de 80 Anos ou mais , Tecido Conjuntivo/diagnóstico por imagem , Elasticidade , Humanos , Pessoa de Meia-Idade , Veia Safena/diagnóstico por imagem , Insuficiência Venosa/diagnóstico por imagem , Adulto Jovem