Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
J Magn Reson Imaging ; 59(3): 929-938, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37366349

RESUMO

BACKGROUND: Apparent diffusion coefficient is not specifically sensitive to tumor microstructure and therapy-induced cellular changes. PURPOSE: To investigate time-dependent diffusion imaging with the short-time-limit random walk with barriers model (STL-RWBM) for quantifying microstructure parameters and early cancer cellular response to therapy. STUDY TYPE: Prospective. POPULATION: Twenty-seven patients (median age of 58 years and 7.4% of females) with p16+/p16- oropharyngeal/oral cavity squamous cell carcinomas (OPSCC/OCSCC) underwent MRI scans before therapy, of which 16 patients had second scans at 2 weeks of the 7-weeks chemoradiation therapy (CRT). FIELD STRENGTH/SEQUENCE: 3-T, diffusion sequence with oscillating gradient spine echo (OGSE) and pulse gradient spin echo (PGSE). ASSESSMENT: Diffusion weighted images were acquired using OGSE and PGSE. Effective diffusion times were derived for the STL-RWBM to estimate free diffusion coefficient D0 , volume-to-surface area ratio of cellular membranes V/S, and cell membrane permeability κ. Mean values of these parameters were calculated in tumor volumes. STATISTICAL TESTS: Tumor microstructure parameters were compared with clinical stages of p16+ I-II OPSCC, p16+ III OPSCC, and p16- IV OCSCC by Spearman's rank correlation and with digital pathological analysis of a resected tissue sample. Tumor microstructure parameter responses during CRT in the 16 patients were assessed by paired t-tests. A P-value of <0.05 was considered statistically significant. RESULTS: The derived effective diffusion times affected estimated values of V/S and κ by 40%. The tumor V/S values were significantly correlated with clinical stages (r = 0.47) as an increase from low to high clinical stages. The in vivo estimated cell size agreed with one from pathological analysis of a tissue sample. Early tumor cellular responses showed a significant increase in D0 (14%, P = 0.03) and non-significant increases in κ (56%, P = 0.6) and V/S (10%, P = 0.1). DATA CONCLUSION: Effective diffusion time estimation might impact microstructure parameter estimation. The tumor V/S was correlated with OPSCC/OCSCC clinical stages. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 1.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Feminino , Humanos , Pessoa de Meia-Idade , Carcinoma de Células Escamosas de Cabeça e Pescoço , Estudos Prospectivos , Imageamento por Ressonância Magnética , Imagem de Difusão por Ressonância Magnética/métodos
2.
Magn Reson Med ; 88(6): 2592-2608, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36128894

RESUMO

Radiation therapy is a major component of cancer treatment pathways worldwide. The main aim of this treatment is to achieve tumor control through the delivery of ionizing radiation while preserving healthy tissues for minimal radiation toxicity. Because radiation therapy relies on accurate localization of the target and surrounding tissues, imaging plays a crucial role throughout the treatment chain. In the treatment planning phase, radiological images are essential for defining target volumes and organs-at-risk, as well as providing elemental composition (e.g., electron density) information for radiation dose calculations. At treatment, onboard imaging informs patient setup and could be used to guide radiation dose placement for sites affected by motion. Imaging is also an important tool for treatment response assessment and treatment plan adaptation. MRI, with its excellent soft tissue contrast and capacity to probe functional tissue properties, holds great untapped potential for transforming treatment paradigms in radiation therapy. The MR in Radiation Therapy ISMRM Study Group was established to provide a forum within the MR community to discuss the unmet needs and fuel opportunities for further advancement of MRI for radiation therapy applications. During the summer of 2021, the study group organized its first virtual workshop, attended by a diverse international group of clinicians, scientists, and clinical physicists, to explore our predictions for the future of MRI in radiation therapy for the next 25 years. This article reviews the main findings from the event and considers the opportunities and challenges of reaching our vision for the future in this expanding field.


Assuntos
Neoplasias , Planejamento da Radioterapia Assistida por Computador , Humanos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos
3.
J Appl Clin Med Phys ; 23(3): e13554, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35128786

RESUMO

PURPOSE: Medical physics residents (MPRs) will define and shape the future of physics in medicine. We sought to better understand the residency experience, as related to resilience and well-being, through the lens of current MPRs and medical physicists (MPs) working with residents. METHODS AND MATERIALS: From February-May 2019, we conducted 32, 1-h, confidential, semi-structured interviews with MPs either currently enrolled in an accredited residency (n = 16) or currently employed by a department with an accredited residency (n = 16). Interviews centered on the topics of mentorship, work/life integration, and discrimination. Qualitative analysis methods were used to derive key themes from the interview transcripts. RESULTS: With regard to the medical physics residency experience, four key themes emerged during qualitative analysis: the demanding nature of medical physics residencies, the negative impacts of residency on MPRs during training and beyond, strategies MPRs use to cope with residency stress, and the role of professional societies in addressing residency-related change. CONCLUSIONS: Residency training is a stress-inducing time in the path to becoming a board-certified MP. By uncovering several sources of this stress, we have identified opportunities to support the resiliency and well-being of MPs in training through recommendations by professional societies, programmatic changes, and interventions at the department and residency program director level for residency programs, as well as strategies that MPRs themselves can use to support well-being on their career journey.


Assuntos
Internato e Residência , Humanos , Mentores , Física
4.
Magn Reson Med ; 79(3): 1345-1353, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28617993

RESUMO

PURPOSE: Respiratory motion can affect pharmacokinetic perfusion parameters quantified from liver dynamic contrast-enhanced MRI. Image registration can be used to align dynamic images after reconstruction. However, intra-image motion blur remains after alignment and can alter the shape of contrast-agent uptake curves. We introduce a method to correct for inter- and intra-image motion during image reconstruction. METHODS: Sixteen liver dynamic contrast-enhanced MRI examinations of nine subjects were performed using a golden-angle stack-of-stars sequence. For each examination, an image time series with high temporal resolution but severe streak artifacts was reconstructed. Images were aligned using region-limited rigid image registration within a region of interest covering the liver. The transformations resulting from alignment were used to correct raw data for motion by modulating and rotating acquired lines in k-space. The corrected data were then reconstructed using view sharing. RESULTS: Portal-venous input functions extracted from motion-corrected images had significantly greater peak signal enhancements (mean increase: 16%, t-test, P < 0.001) than those from images aligned using image registration after reconstruction. In addition, portal-venous perfusion maps estimated from motion-corrected images showed fewer artifacts close to the edge of the liver. CONCLUSIONS: Motion-corrected image reconstruction restores uptake curves distorted by motion. Motion correction also reduces motion artifacts in estimated perfusion parameter maps. Magn Reson Med 79:1345-1353, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Algoritmos , Artefatos , Meios de Contraste , Humanos , Movimento
5.
J Appl Clin Med Phys ; 16(6): 490-500, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699556

RESUMO

We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used to evaluate vaginal cylinders ranging from 20 to 35 mm in diameter with CT and MR. Finally, three patients undergoing HDR brachytherapy with vaginal cylinders that were simulated with both CT and MR were evaluated. In these assessments, the solid applicator models were aligned based on the outline of the applicators on the corresponding volumetric image, and deviations between the central source positions defined based on X-ray markers (on CT) and solid applicator models (on CT and MR), and the percent dose difference between select reference points were calculated. The mean central source deviation defined based on X-ray markers (on CT) and solid applicator models (on CT and MR) for the 15-patient cohort, the phantom, and the 3-patient cohort is 0.6 mm, 0.6 mm, and 1.2 mm, respectively. The average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points were 2.2%, 2.3%, 2.2%, and 2.4%, respectively, for the 15 patient cohort. For the phantom study, the average, absolute percent dose difference for the prescription and inferior reference points are 2.0% and 2.1% for the CT, 2.3% and 2.2% for the T1W, and 2.8% and 3.0% for the T2W images. For the three patient cohort, the average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points are 2.9%, 2.6%, 3.0%, and 4.2% for the CT, 6.5%, 1.6%, 2.5%, and 4.7% for the T1W, and 6.0%, 7.4%, 2.6, and 2.0% for the T2W images. Based on the current study, aligning the applicator model to MR images provides a practical, efficient approach to perform MR-based brachytherapy planning.


Assuntos
Braquiterapia/instrumentação , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Braquiterapia/métodos , Estudos de Coortes , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/radioterapia , Feminino , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Vagina
6.
Med Phys ; 51(4): 2526-2537, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38014764

RESUMO

BACKGROUND: Volumetric reconstruction of magnetic resonance imaging (MRI) from sparse samples is desirable for 3D motion tracking and promises to improve magnetic resonance (MR)-guided radiation treatment precision. Data-driven sparse MRI reconstruction, however, requires large-scale training datasets for prior learning, which is time-consuming and challenging to acquire in clinical settings. PURPOSE: To investigate volumetric reconstruction of MRI from sparse samples of two orthogonal slices aided by sparse priors of two static 3D MRI through implicit neural representation (NeRP) learning, in support of 3D motion tracking during MR-guided radiotherapy. METHODS: A multi-layer perceptron network was trained to parameterize the NeRP model of a patient-specific MRI dataset, where the network takes 4D data coordinates of voxel locations and motion states as inputs and outputs corresponding voxel intensities. By first training the network to learn the NeRP of two static 3D MRI with different breathing motion states, prior information of patient breathing motion was embedded into network weights through optimization. The prior information was then augmented from two motion states to 31 motion states by querying the optimized network at interpolated and extrapolated motion state coordinates. Starting from the prior-augmented NeRP model as an initialization point, we further trained the network to fit sparse samples of two orthogonal MRI slices and the final volumetric reconstruction was obtained by querying the trained network at 3D spatial locations. We evaluated the proposed method using 5-min volumetric MRI time series with 340 ms temporal resolution for seven abdominal patients with hepatocellular carcinoma, acquired using golden-angle radial MRI sequence and reconstructed through retrospective sorting. Two volumetric MRI with inhale and exhale states respectively were selected from the first 30 s of the time series for prior embedding and augmentation. The remaining 4.5-min time series was used for volumetric reconstruction evaluation, where we retrospectively subsampled each MRI to two orthogonal slices and compared model-reconstructed images to ground truth images in terms of image quality and the capability of supporting 3D target motion tracking. RESULTS: Across the seven patients evaluated, the peak signal-to-noise-ratio between model-reconstructed and ground truth MR images was 38.02 ± 2.60 dB and the structure similarity index measure was 0.98 ± 0.01. Throughout the 4.5-min time period, gross tumor volume (GTV) motion estimated by deforming a reference state MRI to model-reconstructed and ground truth MRI showed good consistency. The 95-percentile Hausdorff distance between GTV contours was 2.41 ± 0.77 mm, which is less than the voxel dimension. The mean GTV centroid position difference between ground truth and model estimation was less than 1 mm in all three orthogonal directions. CONCLUSION: A prior-augmented NeRP model has been developed to reconstruct volumetric MRI from sparse samples of orthogonal cine slices. Only one exhale and one inhale 3D MRI were needed to train the model to learn prior information of patient breathing motion for sparse image reconstruction. The proposed model has the potential of supporting 3D motion tracking during MR-guided radiotherapy for improved treatment precision and promises a major simplification of the workflow by eliminating the need for large-scale training datasets.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Humanos , Estudos Retrospectivos , Movimento (Física) , Respiração , Espectroscopia de Ressonância Magnética , Imageamento Tridimensional
7.
Artigo em Inglês | MEDLINE | ID: mdl-38971385

RESUMO

INTRODUCTION: Local failure rates after treatment for locally advanced non-small-cell lung cancer (NSCLC) remain high. Efforts to improve local control with uniform dose-escalation or dose-escalation to mid-treatment PET-avid residual disease have been limited by heightened toxicity. This trial aimed to refine response-based adaptive radiation (RT) and minimize toxicity by incorporating FDG-PET and V/Q SPECT imaging mid-treatment. METHODS: 47 patients with Stage IIA-III unresectable NSCLC were prospectively enrolled in this single-institution trial (NCT02492867). Patients received concurrent chemoradiation with personalized response-based adaptive RT over 30 fractions incorporating V/Q SPECT and FDG-PET. The first 21 fractions (46.2Gy at 2.2 Gy/fraction) were delivered to the tumor while minimizing dose to SPECT-defined functional lung. The plan was then adapted for the final 9 fractions (2.2-3.8Gy/fraction) up to a total of 80.4Gy, based on mid-treatment FDG-PET tumor response to escalate dose to residual tumor while minimizing dose to SPECT-defined functional lung. Non-progressing patients received consolidative carboplatin/paclitaxel or durvalumab. The primary endpoint of the study was ≥ grade 2 lung and esophageal toxicities. Secondary endpoints included time to local progression, tumor response, and overall survival. RESULTS: At one year post-treatment, the rates of grade 2 and grade 3 pneumonitis were 21.3% and 2.1%, respectively, with no difference in pneumonitis rates among patients who received and did not receive adjuvant durvalumab (p=0.74). While there were no grade 3 esophageal-related toxicities, 66.0% of patients experienced grade 2 esophagitis. 1- and 2-year local control rates were 94.5% (95% CI, 87.4% - 100%) and 87.5% (95% CI, 76.7% - 100%), respectively. Overall survival was 82.8% (95% CI, 72.6% -94.4%) at 1 year and 62.3% (95% CI, 49.6%-78.3%) at 2 years. CONCLUSIONS: Response-based adaptive dose-escalation accounting for tumor change and normal tissue function during treatment provided excellent local control, comparable toxicity to standard chemoradiation, and did not increase toxicity with adjuvant immunotherapy.

8.
Phys Med Biol ; 68(7)2023 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-36791470

RESUMO

Objective.Online adaptive radiotherapy has demonstrated improved dose conformality in response to inter-fraction geometric variations in the abdomen. The dosimetric impact of intra-fractional variations in anatomic configuration resulting from breathing, gastric contraction and slow configuration motion, however, have been largely ignored, leading to differences between delivered and planned. To investigate the impact of intra-fractional abdominal motions on delivered dose, anatomical deformations due to these three motion modes were extracted from dynamic MRI data using a previously developed hierarchical motion modeling methodology.Approach. Motion magnitudes were extracted from deformation fields between a reference state and all other motion states of the patient. Delivered dose estimates to various gastrointestinal organs (stomach, duodenum, small bowel and colon) were calculated on each motion state of the patient and accumulated to estimate the delivered dose to each organ for the entire treatment fraction.Main results. Across a sample of 10 patients, maximal motions of 33.6, 33.4, 47.6 and 49.2 mm were observed over 20 min for the stomach, duodenum, small bowel and colon respectively. Dose accumulation results showed that motions could lead to average increases of 2.0, 2.1, 1.1, 0.7 Gy to the maximum dose to 0.5cc (D0.5cc) and 3.0, 2.5, 1.3, 0.9 Gy to the maximum dose to 0.1cc (D0.1cc) for these organs at risk. From the 40 dose accumulations performed (10 for each organ at risk), 27 showed increases of modeled delivered dose compared to planned doses, 4 of which exceeded planned dose constraints.Significance. The use of intra-fraction motion measurements to accumulate delivered doses is feasible, and supports retrospective estimation of dose delivery to improve estimates of delivered doses, and further guide strategies for both plan adaptation as well as advances in intra-fraction motion management.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Estudos Retrospectivos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Abdome
9.
Int J Radiat Oncol Biol Phys ; 117(5): 1236-1240, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37414260

RESUMO

There is debate about why stereotactic body radiation therapy (SBRT) produces superior control of hepatocellular cancer (HCC) compared to fractionated treatment. Both preclinical and clinical evidence has been presented to support a "classic" biological explanation: the greater BED of SBRT produces more DNA damage and tumor cell kill. More recently, preclinical evidence has supported the concept of a "new biology", particularly radiation-induced vascular collapse, which increases hypoxia and free radical activation. This is hypothesized to cause much greater tumor cell death than was produced by the initial radiation-induced DNA damage to the tumor. We decided to investigate if vascular collapse occurs after standard SBRT for patients with HCC. Eight patients with 10 lesions underwent dynamic contrast enhanced MRI at the time of simulation and either 48 or 96 hours after the first fraction. Only three of 10 tumors showed a decrease in blood flow. These findings suggest that vascular collapse does not typically occur after SBRT for HCC.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Radiocirurgia , Humanos , Neoplasias Hepáticas/patologia , Carcinoma Hepatocelular/patologia , Radiocirurgia/efeitos adversos , Fracionamento da Dose de Radiação , Dano ao DNA
10.
Int J Radiat Oncol Biol Phys ; 116(2): 314-327, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36252781

RESUMO

PURPOSE: Gender-based discrimination and sexual harassment have been well-studied in the fields of science, technology, engineering, math, and medicine. However, less is known about these topics and their effect within the profession of medical physics. We aimed to better understand and clarify the views and experiences of practicing medical physicists and medical physics residents regarding gender-based discrimination and sexual harassment. METHODS AND MATERIALS: We conducted in-depth, semistructured, and confidential interviews with 32 practicing medical physicists and medical physics residents across the United States. The interviews were broad and covered the topics of discrimination, mentorship, and work/life integration. All participants were associated with a department with a residency program accredited by the Commission on Accreditation of Medical Physics Education Programs and had appointments with a clinical component. RESULTS: Participants shared views about gender-based discrimination and sexual harassment that were polarized. Some perceived that discrimination and harassment were a current concern within medical physics, while some either perceived that they were not a concern or that discrimination positively affected women and minoritized populations. Many participants shared personal experiences of discrimination and harassment, including those related to unequal compensation, discrimination against mothers, discrimination during the hiring process, gender-biased assumptions about behaviors or goals, communication biases, and overt and persistent sexual harassment. CONCLUSIONS: There is an urgent need to acknowledge, better understand, and address gender-based discrimination and sexual harassment in the field of medical physics.


Assuntos
Medicina , Assédio Sexual , Humanos , Feminino , Estados Unidos , Inquéritos e Questionários , Sexismo , Física
12.
Med Phys ; 39(11): 6672-81, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23127061

RESUMO

PURPOSE: Arteriovenous malformations are often treated with a combination of embolization and stereotactic radiosurgery. Concern has been expressed in the past regarding the dosimetric properties of materials used in embolization and the effects that the introduction of these materials into the brain may have on the quality of the radiosurgery plan. To quantify these effects, the authors have taken large volumes of Onyx 34 and Onyx 18 (ethylene-vinyl alcohol copolymer doped with tantalum) and measured the attenuation and interface effects of these embolization materials. METHODS: The manufacturer provided large cured volumes (∼28 cc) of both Onyx materials. These samples were 8.5 cm in diameter with a nominal thickness of 5 mm. The samples were placed on a block tray above a stack of solid water with an Attix chamber at a depth of 5 cm within the stack. The Attix chamber was used to measure the attenuation. These measurements were made for both 6 and 16 MV beams. Placing the sample directly on the solid water stack and varying the thickness of solid water between the sample and the Attix chamber measured the interface effects. The computed tomography (CT) numbers for bulk material were measured in a phantom using a wide bore CT scanner. RESULTS: The transmission through the Onyx materials relative to solid water was approximately 98% and 97% for 16 and 6 MV beams, respectively. The interface effect shows an enhancement of approximately 2% and 1% downstream for 16 and 6 MV beams. CT numbers of approximately 2600-3000 were measured for both materials, which corresponded to an apparent relative electron density (RED) ρ(e) (w) to water of approximately 2.7-2.9 if calculated from the commissioning data of the CT scanner. CONCLUSIONS: We performed direct measurements of attenuation and interface effects of Onyx 34 and Onyx 18 embolization materials with large samples. The introduction of embolization materials affects the dose distribution of a MV therapeutic beam, but should be of negligible consequence for effective thicknesses of less than 8 mm. The measured interface effects are also small, particularly at 6 MV. Large areas of high-density artifacts and low-density artifacts can cause errors in dose calculations and need to be identified and resolved during planning.


Assuntos
Embolização Terapêutica/métodos , Radiometria/métodos , Radiocirurgia/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X
13.
Med Phys ; 49(9): 6110-6119, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35766221

RESUMO

PURPOSE: To develop a geometry-informed deep learning framework for volumetric MRI with sub-second acquisition time in support of 3D motion tracking, which is highly desirable for improved radiotherapy precision but hindered by the long image acquisition time. METHODS: A 2D-3D deep learning network with an explicitly defined geometry module that embeds geometric priors of the k-space encoding pattern was investigated, where a 2D generation network first augmented the sparsely sampled image dataset by generating new 2D representations of the underlying 3D subject. A geometry module then unfolded the 2D representations to the volumetric space. Finally, a 3D refinement network took the unfolded 3D data and outputted high-resolution volumetric images. Patient-specific models were trained for seven abdominal patients to reconstruct volumetric MRI from both orthogonal cine slices and sparse radial samples. To evaluate the robustness of the proposed method to longitudinal patient anatomy and position changes, we tested the trained model on separate datasets acquired more than one month later and evaluated 3D target motion tracking accuracy using the model-reconstructed images by deforming a reference MRI with gross tumor volume (GTV) contours to a 5-min time series of both ground truth and model-reconstructed volumetric images with a temporal resolution of 340 ms. RESULTS: Across the seven patients evaluated, the median distances between model-predicted and ground truth GTV centroids in the superior-inferior direction were 0.4 ± 0.3 mm and 0.5 ± 0.4 mm for cine and radial acquisitions, respectively. The 95-percentile Hausdorff distances between model-predicted and ground truth GTV contours were 4.7 ± 1.1 mm and 3.2 ± 1.5 mm for cine and radial acquisitions, which are of the same scale as cross-plane image resolution. CONCLUSION: Incorporating geometric priors into deep learning model enables volumetric imaging with high spatial and temporal resolution, which is particularly valuable for 3D motion tracking and has the potential of greatly improving MRI-guided radiotherapy precision.


Assuntos
Aprendizado Profundo , Radioterapia Guiada por Imagem , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética , Movimento (Física) , Radioterapia Guiada por Imagem/métodos
14.
Phys Med Biol ; 68(1)2022 12 16.
Artigo em Inglês | MEDLINE | ID: mdl-36174550

RESUMO

Objective.Precision radiation therapy requires managing motions of organs at risk that occur during treatment. While methods have been developed for real-time respiratory motion tracking, non-breathing intra-fractional variations (including gastric contractile motion) have seen little attention to date. The purpose of this study is to develop a cyclic gastric contractile motion prediction model to support real-time management during radiotherapy.Approach. The observed short-term reproducibility of gastric contractile motion permitted development of a prediction model that (1) extracts gastric contraction motion phases from few minutes of golden angle stack of stars scanning (at patient positioning), (2) estimate gastric phase of real-time sampled data acquired during treatment delivery to these reconstructed phases and (3) predicting future gastric phase by linear extrapolation using estimation results from step 2 to account for processing and system latency times. Model was evaluated on three parameters including training time window for step 1, number of spokes for real-time sampling data in step 2 and future prediction time. Mainresults. The model was tested on a population of 20 min data samples from 25 scans from 15 patients. The mean prediction error with 10 spokes and 2 min training was 0.3 ± 0.1 mm (0.1-0.7 mm) with 5.1 s future time, slowly rising to 0.6 ± 0.2 mm (0.2-1.1 mm) for 6.8 s future time and then increasing rapidly for longer forward predictions, for an average 3.6 ± 0.5 mm (2.8-4.7 mm) HD95 of gastric motion. Results showed that reducing of train time window (5-2 min) does not influence the prediction performance, while using 5 spokes increased prediction errors.Significance. The proposed gastric motion prediction model has sufficiently accurate prediction performance to allow for sub-millimeter accuracy while allowing sufficient time for data processing and machine interaction and shows the potential for clinical implementation to support stomach motion tracking during radiotherapy.


Assuntos
Respiração , Estômago , Humanos , Reprodutibilidade dos Testes , Movimento (Física) , Estômago/diagnóstico por imagem
15.
J Med Imaging (Bellingham) ; 9(6): 064503, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36466078

RESUMO

Purpose: Building accurate and robust artificial intelligence systems for medical image assessment requires the creation of large sets of annotated training examples. However, constructing such datasets is very costly due to the complex nature of annotation tasks, which often require expert knowledge (e.g., a radiologist). To counter this limitation, we propose a method to learn from medical images at scale in a self-supervised way. Approach: Our approach, based on contrastive learning and online feature clustering, leverages training datasets of over 100,000,000 medical images of various modalities, including radiography, computed tomography (CT), magnetic resonance (MR) imaging, and ultrasonography (US). We propose to use the learned features to guide model training in supervised and hybrid self-supervised/supervised regime on various downstream tasks. Results: We highlight a number of advantages of this strategy on challenging image assessment problems in radiography, CT, and MR: (1) significant increase in accuracy compared to the state-of-the-art (e.g., area under the curve boost of 3% to 7% for detection of abnormalities from chest radiography scans and hemorrhage detection on brain CT); (2) acceleration of model convergence during training by up to 85% compared with using no pretraining (e.g., 83% when training a model for detection of brain metastases in MR scans); and (3) increase in robustness to various image augmentations, such as intensity variations, rotations or scaling reflective of data variation seen in the field. Conclusions: The proposed approach enables large gains in accuracy and robustness on challenging image assessment problems. The improvement is significant compared with other state-of-the-art approaches trained on medical or vision images (e.g., ImageNet).

16.
Int J Radiat Oncol Biol Phys ; 112(2): 417-425, 2022 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-34509552

RESUMO

PURPOSE: Radiation therapy (RT) can increase the risk of cardiac events in patients with breast cancer (BC), but biomarkers predicting risk for developing RT-induced cardiac disease are currently lacking. We report results from a prospective clinical trial evaluating early magnetic resonance imaging (MRI) and serum biomarker changes as predictors of cardiac injury and risk of subsequent cardiac events after RT for left-sided disease. METHODS: Women with node-negative and node-positive (N-/+) left-sided BC were enrolled on 2 institutional review board (IRB)-approved protocols at 2 institutions. MRI was conducted pretreatment (within 1 week of starting radiation), at the end of treatment (last day of treatment ±1 week), and 3 months after the last day of treatment (±2 weeks) to quantify left and right ventricular volumes and function, myocardial fibrosis, and edema. Perfusion changes during regadenoson stress perfusion were also assessed on a subset of patients (n = 28). Serum was collected at the same time points. Whole heart and cardiac substructures were contoured using CT and MRI. Models were constructed using baseline cardiac and clinical risk factors. Associations between MRI-measured changes and dose were evaluated. RESULTS: Among 51 women enrolled, mean heart dose ranged from 0.80 to 4.7 Gy and mean left ventricular (LV) dose from 1.1 to 8.2 Gy, with mean heart dose 2.0 Gy. T1 time, a marker of fibrosis, and right ventricular (RV) ejection fraction (EF) significantly changed with treatment; these were not dose dependent. T2 (marker of edema) and LV EF did not significantly change. No risk factors were associated with baseline global perfusion. Prior receipt of doxorubicin was marginally associated with decreased myocardial perfusion after RT (P = .059), and mean MHD was not associated with perfusion changes. A significant correlation between baseline IL-6 and mean heart dose (MHD) at the end of RT (ρ 0.44, P = .007) and a strong trend between troponin I and MHD at 3 months post-treatment (ρ 0.33, P = .07) were observed. No other significant correlations were identified. CONCLUSIONS: In this prospective study of women with left-sided breast cancer treated with contemporary treatment planning, cardiac radiation doses were very low relative to historical doses reported by Darby et al. Although we observed significant changes in T1 and RV EF shortly after RT, these changes were not correlated with whole heart or substructure doses. Serum biomarker analysis of cardiac injury demonstrates an interesting trend between markers and MHD that warrants further investigation.


Assuntos
Neoplasias da Mama , Cardiotoxicidade , Biomarcadores , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/patologia , Neoplasias da Mama/radioterapia , Cardiotoxicidade/diagnóstico por imagem , Cardiotoxicidade/etiologia , Feminino , Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos
17.
Med Phys ; 48(5): 2521-2527, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33595909

RESUMO

PURPOSE: Gastrointestinal motion patterns such as peristalsis and segmental contractions can alter the shape and position of the stomach and intestines with respect to other irradiated organs during radiation therapy. Unfortunately, these deformations are concealed by conventional four-dimensional (4D)-MRI techniques, which were developed to visualize respiratory motion by binning acquired data into respiratory motion states without considering the phases of GI motion. We present a method to reconstruct breathing-compensated images showing the phases of periodic gastric motion and study the effect of this motion on regional anatomical structures. METHODS: Sixty-seven DCE-MRI examinations were performed on patients undergoing MRI simulation for hepatocellular carcinoma using a golden-angle stack-of-stars sequence that collected 2000 radial spokes over 5 min. The collected data were reconstructed using a method with integrated respiratory motion correction into a time series of 3D image volumes without visible breathing motion. From this series, a gastric motion signal was extracted by temporal filtering of time-intensity curves in the stomach. Using this motion signal, breathing-corrected back-projection images were sorted according to the gastric phase and reconstructed into 21 gastric motion state images showing the phases of gastric motion. RESULTS: Reconstructed image volumes showed gastric motion states clearly with no visible breathing motion or related artifacts. The mean frequency of the gastric motion signal was 3 cycles/min with a standard deviation of 0.27 cycles/min. CONCLUSIONS: Periodic gastrointestinal motion can be visualized without confounding respiratory motion using the presented GI 4D MRI technique. GI 4D MRIs may help define internal target volumes for treatment planning, aid in planning organ at risk volume definition, or support motion model development for gastrointestinal motion tracking algorithms for real-time MR-guided radiation therapy.


Assuntos
Imageamento Tridimensional , Imageamento por Ressonância Magnética , Algoritmos , Artefatos , Humanos , Movimento (Física) , Respiração
18.
Phys Med Biol ; 66(4): 045018, 2021 02 09.
Artigo em Inglês | MEDLINE | ID: mdl-33361579

RESUMO

Abdominal organs are subject to a variety of physiological forces that superimpose their effects to influence local motion and configuration. These forces not only include breathing, but can also arise from cyclic antral contractions and a range of slow configuration changes. To elucidate each individual motion pattern as well as their combined effects, a hierarchical motion model was built for characterization of these 3 motion modes (characterized as deformation maps between states) using golden angle radial MR signals. Breathing motions are characterized first. Antral contraction states are then reconstructed after breathing motion-induced deformation are corrected; slow configuration change states are further extracted from breathing motion-corrected image reconstructions. The hierarchical model is established based on these multimodal states, which can be either individually shown or combined to demonstrate any arbitrary composited motion patterns. The model was evaluated using 20 MR scans acquired from 9 subjects. Poor reproducibility of breathing motions both within as well as between scan sessions was observed, with an average intra-subject difference of 1.6 cycles min-1 for average breathing frequencies of 12.0 cycles min-1. Antral contraction frequency distributions were more stable than breathing, but also presented poor reproducibility between scans with an average difference of 0.3 cycles min-1 for average frequencies of 3.2 cycles min-1. The magnitudes of motions beyond breathing were found to be significant, with 14.4 and 33.8 mm maximal motions measured from antral contraction and slow configuration changes, respectively. Hierarchical motion models have potential in multiple applications in radiotherapy, including improving the accuracy of dose delivery estimation, providing guidance for margin creation, and supporting advanced decisions and strategies for immobilization, treatment monitoring and gating.


Assuntos
Abdome/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Modelos Teóricos , Humanos , Movimento , Reprodutibilidade dos Testes , Respiração
19.
Phys Med Biol ; 66(17)2021 09 03.
Artigo em Inglês | MEDLINE | ID: mdl-34412047

RESUMO

Abdominal organ motions introduce geometric uncertainties to radiotherapy. This study investigates a multi-temporal resolution 3D motion prediction scheme that accounts for both breathing and slow drifting motion in the abdomen in support of MRI-guided radiotherapy. Ten-minute MRI scans were acquired for 8 patients using a volumetric golden-angle stack-of-stars sequence. The first five-minutes was used for patient-specific motion modeling. Fast breathing motion was modeled from high temporal resolution radial k-space samples, which served as a navigator signal to sort k-space data into different bins for high spatial resolution reconstruction of breathing motion states. Slow drifting motion was modeled from a lower temporal resolution image time series which was reconstructed by sequentially combining a large number of breathing-corrected k-space samples. Principal components analysis (PCA) was performed on deformation fields between different motion states. Gaussian kernel regression and linear extrapolation were used to predict PCA coefficients of future motion states for breathing motion (340 ms ahead of acquisition) and slow drifting motion (8.5 s ahead of acquisition) respectively. k-space data from the remaining five-minutes was used to compare ground truth motions states obtained from retrospective reconstruction/deformation with predictions. Median distances between predicted and ground truth centroid positions of gross tumor volume (GTV) and organs at risk (OARs) were less than 1 mm on average. 95- percentile Hausdorff distances between predicted and ground truth GTV contours of various breathing motions states were 2 mm on average, which was smaller than the imaging resolution and 95-percentile Hausdorff distances between predicted and ground truth OAR contours of different slow drifting motion states were less than 0.2 mm. These results suggest that multi-temporal resolution motion models are capable of volumetric predictions of breathing and slow drifting motion with sufficient accuracy and temporal resolution for MRI-based tracking, and thus have potential for supporting MRI-guided abdominal radiotherapy.


Assuntos
Abdome , Imageamento por Ressonância Magnética , Respiração , Abdome/diagnóstico por imagem , Humanos , Imageamento Tridimensional , Movimento (Física) , Estudos Retrospectivos
20.
Med Phys ; 48(2): 715-723, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33617034

RESUMO

PURPOSE: Most existing computed tomography (CT)-ventilation imaging techniques are based on deformable image registration (DIR) of different respiratory phases of a four-dimensonal CT (4DCT) scan of the lung, followed by the quantification of local breathing-induced changes in Hounsfield Units (HU) or volume. To date, only moderate correlations have been reported between these CT-ventilation metrics and standard ventilation imaging modalities for adaptive lung radiation therapy. This study evaluates the use of stress maps derived from biomechanical model-based DIR as an alternative CT-ventilation metric. MATERIALS AND METHODS: Six patients treated for lung cancer with conventional radiation therapy were retrospectively analyzed. For each patient, a 4DCT scan and Tc-99m SPECT-V image acquired for treatment planning were collected. Biomechanical model-based DIR was applied between the inhale and exhale phase of the 4DCT scans and stress maps were calculated. The voxel-wise correlation between the reference SPECT-V image and map of the maximum principal stress was measured with a Spearman correlation coefficient. The overlap between high (above the 75th percentile) and low (below the 25th percentile) functioning volumes extracted from the reference SPECT-V and the stress maps was measured with Dice similarity coefficients (DSC). The results were compared to those obtained when using two classical CT-ventilation metrics: the change in HU and Jacobian determinant. RESULTS: The mean Spearman correlation coefficients were: 0.37 ± 18 and 0.39 ± 13 and 0.59 ± 0.13 considering the changes in HU, Jacobian and maximum principal stress, respectively. The corresponding mean DSC coefficients were 0.38 ± 0.09, 0.37 ± 0.07 and 0.52 ± 0.07 for the high ventilation function volumes and 0.48 ± 0.13, 0.44 ± 0.09 and 0.52 ± 0.07 for the low ventilation function volumes. CONCLUSION: For presenting a significantly stronger and more consistent correlation with standard SPECT-V images than previously proposed CT-ventilation metrics, stress maps derived with the proposed method appear to be a promising tool for incorporation into functional lung avoidance strategies.


Assuntos
Neoplasias Pulmonares , Ventilação Pulmonar , Tomografia Computadorizada Quadridimensional , Humanos , Pulmão/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA