Blood Purif ; 50(2): 180-187, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33454709

RESUMO

INTRODUCTION: Patients in hemodiafiltration (HDF) eliminate volume overload by ultrafiltration. Vascular volume loss is among the main mechanisms contributing to adverse events such as intradialytic hypotension. Here, we hypothesize that the intradialytic exercise (IDEX) is an intervention that could improve the acute response of physiological mechanisms involved during vascular volume loss. To test this hypothesis, we evaluated the hemodynamic response to mild aerobic exercise during HDF. METHODS: Nineteen end-stage renal disease (ESRD) patients (11 women: 40 ± 10.8 years old, and 8 men: 42 ± 21 years old) receiving HDF thrice a week, with 6 months of previous physical conditioning, participated in this study. Three HDF sessions were scheduled for each patient: 1 resting in supine position, 1 resting in sitting position, and 1 doing aerobic exercise. The first 2 sessions were taken as control. The ultrafiltration rate was set to 800 mL/h in each session. The hemodynamic response was monitored through the relative blood volume (RBV), and cardiovascular variables measured noninvasively by photoplethysmography. Adequacy variables such as Kt/V and percentage reduction of urate, urea, creatinine (Cr), and phosphate were also monitored. FINDINGS: The decrease rate of the RBV was smaller in the session with IDEX compared to the sessions with no exercise. No differences were found neither in the cardiovascular variables nor in the adequacy variables among the 3 sessions. There were no hypotension events during the session with exercise, and 8 events during the sessions without exercise (p = 0.002). DISCUSSION: Mild exercise during HDF decreased the RBV drop and was associated with less hypotension events. The lack of differences in the hemodynamic variables suggests an adequate acute response of cardiovascular compensation variables to intradialytic hypovolemia.


Assuntos
Volume Sanguíneo , Exercício Físico , Hemodiafiltração , Falência Renal Crônica/terapia , Adulto , Feminino , Hemodiafiltração/efeitos adversos , Hemodiafiltração/métodos , Hemodinâmica , Humanos , Hipotensão/etiologia , Falência Renal Crônica/sangue , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
2.
Artif Organs ; 40(7): 684-91, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26582542

RESUMO

Hemodialysis (HD) is usually performed with the gradually decreasing ultrafiltration rate (UFR) profile (dUFR). The aim of the present study was to compare the hemodynamic response to HD with the dUFR to that of HD with the gradually increasing UFR profile (iUFR). The study population included 10 patients (three women, mean age: 28 ± 8 years) undergoing maintenance HD who had reached dry weight without taking antihypertensive medications. Each patient received (in random order) one HD session with the dUFR and another with the iUFR (both with 3 h total UFR = 2200 mL). Hemodynamic response was evaluated with a brachial blood pressure (BP) monitor, echocardiogram and Portapres to measure digital BP, heart rate, cardiac output, stroke volume, and peripheral resistance. Mean values were compared at each HD hour during the first 3 h of a 4-h HD session. The HD characteristics, including Kt/V, were similar for both UFR profiles. Relative blood volume decreased more gradually and linearly with the iUFR. Hemodynamic variables were not significantly different between the two profiles, but brachial BP was more stable with the iUFR. Digital diastolic BP increased with both profiles. Peripheral resistance increased with both profiles, and tended to increase more with the iUFR. Echocardiographic variables changed similarly during the HD session with both profiles. In conclusion, these two UFR profiles are similar in most hemodynamic variables. The statistical equivalence of both profiles suggests that either could be prescribed based on the clinical characteristics of the patient.


Assuntos
Hemodinâmica , Diálise Renal/métodos , Ultrafiltração/métodos , Adulto , Pressão Sanguínea , Débito Cardíaco , Feminino , Frequência Cardíaca , Humanos , Masculino , Adulto Jovem
3.
Arch Cardiol Mex ; 82(3): 197-203, 2012.
Artigo em Espanhol | MEDLINE | ID: mdl-23021355

RESUMO

OBJECTIVE: To develop a portable signal monitoring equipment for electrocardiography (ECG) and heart rate (HR), communicated with a mobile phone using the Bluetooth (BT) communication protocol for display of the signal on screen. METHODS: A monitoring system was designed in which the electronic section performs the ECG signal acquisition, as well as amplification, filtering, analog to digital conversion and transmission of the ECG and HR using BT. Two programs were developed for the system. The first one calculates HR through QRS identification and sends the ECG signals and HR to the mobile, and the second program is an application to acquire and display them on the mobile screen. RESULTS: We developed a portable electronic system powered by a 9 volt battery, with amplification and bandwidth meeting the international standards for ECG monitoring. The QRS complex identification was performed using the second derivative algorithm, while the programs allow sending and receiving information from the ECG and HR via BT, and viewing it on the mobile screen. The monitoring is feasible within distances of 15 m and it has been tested in various mobiles telephones of brands Nokia®, Sony Ericsson® and Samsung®. CONCLUSIONS: This system shows an alternative for mobile monitoring using BT and Java 2 Micro Edition (J2ME) programming. It allows the register of the ECG trace and HR, and it can be implemented in different phones.


Assuntos
Telefone Celular , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca , Humanos
4.
Life (Basel) ; 12(7)2022 Jul 09.
Artigo em Inglês | MEDLINE | ID: mdl-35888108

RESUMO

Cardiovascular regulatory mechanisms that fail to compensate for ultrafiltration and cause hypovolemia during hemodialysis (HD) are not completely understood. This includes the interaction between the autonomic nervous system and the biochemistry that regulates blood pressure and modulates cardiac activity and vascular tone in response to hypovolemia in patients treated with HD. The objective was to evaluate the association of spectral indices of heart rate variability (HRV) with serum levels of angiotensin II, angiotensin 1-7, nitric oxide and total antioxidant capacity during HD. Electrocardiographic records were obtained from 20 patients during HD (3 h), from which HRV data and spectral power data in the very-low-frequency (VLF), low-frequency (LF) and high-frequency (HF) bands were generated. Three blood samples per patient were collected during HD (0.0, 1.5, 3.0 h) to determine the levels of biomarkers involved in the pressor response during HD. Angiotensin II had a positive correlation with VLF (r = 0.390) and with LF/HF (r = 0.359) and a negative correlation with LF (r = -0.262) and HF (r = -0.383). There were no significant correlations between HRV and the other biomarkers. These results suggest that during HD, VLF could reflect the serum levels of angiotensin II, which may be associated with the autonomic response to HD.

5.
Arch Cardiol Mex ; 87(1): 61-71, 2017.
Artigo em Espanhol | MEDLINE | ID: mdl-27956339

RESUMO

OBJECTIVE: To improve the identification of peaks and feet in photoplethysmographic (PPG) pulses deformed by myokinetic noise, through the implementation of a modified fingertip and applying adaptive filtering. METHOD: PPG signals were recordedfrom 10 healthy volunteers using two photoplethysmography systems placed on the index finger of each hand. Recordings lasted three minutes andwere done as follows: during the first minute, both handswere at rest, and for the lasting two minutes only the left hand was allowed to make quasi-periodicmovementsin order to add myokinetic noise. Two methodologies were employed to process the signals off-line. One consisted on using an adaptive filter based onthe Least Mean Square (LMS) algorithm, and the other includeda preprocessing stage in addition to the same LMS filter. Both filtering methods were compared and the one with the lowest error was chosen to assess the improvement in the identification of peaks and feet from PPG pulses. RESULTS: Average percentage errorsobtained wereof 22.94% with the first filtering methodology, and 3.72% withthe second one. On identifying peaks and feet from PPG pulsesbefore filtering, error percentages obtained were of 24.26% and 48.39%, respectively, and once filtered error percentageslowered to 2.02% for peaks and 3.77% for feet. CONCLUSIONS: The attenuation of myokinetic noise in PPG pulses through LMS filtering, plusa preprocessing stage, allows increasingthe effectiveness onthe identification of peaks and feet from PPG pulses, which are of great importance for medical assessment.


Assuntos
Fotopletismografia/métodos , Artefatos , Humanos , Modelos Lineares
6.
Arq Bras Cardiol ; 105(3): 276-84, 2015 Sep.
Artigo em Inglês, Português | MEDLINE | ID: mdl-26176187

RESUMO

BACKGROUND: Diabetes affects approximately 250 million people in the world. Cardiovascular autonomic neuropathy is a common complication of diabetes that leads to severe postural hypotension, exercise intolerance, and increased incidence of silent myocardial infarction. OBJECTIVE: To determine the variability of heart rate (HR) and systolic blood pressure (SBP) in recently diagnosed diabetic patients. METHODS: The study included 30 patients with a diagnosis of type 2 diabetes of less than 2 years and 30 healthy controls. We used a Finapres® device to measure during five minutes beat-to-beat HR and blood pressure in three experimental conditions: supine position, standing position, and rhythmic breathing at 0.1 Hz. The results were analyzed in the time and frequency domains. RESULTS: In the HR analysis, statistically significant differences were found in the time domain, specifically on short-term values such as standard deviation of NN intervals (SDNN), root mean square of successive differences (RMSSD), and number of pairs of successive NNs that differ by more than 50 ms (pNN50). In the BP analysis, there were no significant differences, but there was a sympathetic dominance in all three conditions. The baroreflex sensitivity (BRS) decreased in patients with early diabetes compared with healthy subjects during the standing maneuver. CONCLUSIONS: There is a decrease in HR variability in patients with early type 2 diabetes. No changes were observed in the BP analysis in the supine position, but there were changes in BRS with the standing maneuver, probably due to sympathetic hyperactivity.


Assuntos
Pressão Sanguínea/fisiologia , Diabetes Mellitus Tipo 2/fisiopatologia , Frequência Cardíaca/fisiologia , Adulto , Sistema Nervoso Autônomo/fisiopatologia , Barorreflexo/fisiologia , Estudos de Casos e Controles , Neuropatias Diabéticas/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Postura/fisiologia , Fatores de Tempo
7.
Arch. cardiol. Méx ; 87(1): 61-71, ene.-mar. 2017. tab, graf
Artigo em Espanhol | LILACS | ID: biblio-887494

RESUMO

Resumen: Objetivo: Mejorar la identificación de cimas y pies en el pulso fotopletismográfico (PPG, por sus siglas en inglés), deformado por efecto del ruido miocinético, mediante la implementación de un dedal modificado y filtrado adaptativo. Método: Se obtuvo el PPG en 10 voluntarios sanos empleando 2 sistemas de fotopletismografía colocados en el dedo índice de cada mano, y registrándolos simultáneamente durante 3 min. Durante el primer minuto de registro, ambas manos estuvieron en reposo, y durante los 2 min posteriores, solo la mano izquierda realizó movimientos cuasi-periódicos para añadir ruido miocinético. Se emplearon 2 metodologías para procesar las señales fuera de línea, en una se usó un filtro con el algoritmo de mínimos cuadrados promediados (LMS, por sus siglas en inglés) y en la otra se hizo un preprocesamiento adicional al filtrado LMS. Ambas metodologías fueron comparadas y la de menor error porcentual en la señal recuperada se utilizó para valorar la mejora en la identificación de cimas y pies del PPG. Resultados: El error promedio obtenido fue del 22.94% para la primera metodología, y del 3.72% para la segunda. Los errores en la identificación de cimas y pies antes de filtrar el PPG fueron del 24.26 y 48.39%, respectivamente, una vez filtrados, disminuyeron a 2.02 y 3.77%, respectivamente. Conclusiones: El filtrado adaptativo basado en el algoritmo LMS, más una etapa de preprocesamiento, permite atenuar el ruido miocinético en el PPG, y aumentar la efectividad en la identificación de cimas y pies de pulso, que resultan de gran importancia para una valoración médica.


Abstract: Objective: To improve the identification of peaks and feet in photoplethysmographic (PPG) pulses deformed by myokinetic noise, through the implementation of a modified fingertip and applying adaptive filtering. Method: PPG signals were recordedfrom 10 healthy volunteers using two photoplethysmography systems placed on the index finger of each hand. Recordings lasted three minutes andwere done as follows: during the first minute, both handswere at rest, and for the lasting two minutes only the left hand was allowed to make quasi-periodicmovementsin order to add myokinetic noise. Two methodologies were employed to process the signals off-line. One consisted on using an adaptive filter based onthe Least Mean Square (LMS) algorithm, and the other includeda preprocessing stage in addition to the same LMS filter. Both filtering methods were compared and the one with the lowest error was chosen to assess the improvement in the identification of peaks and feet from PPG pulses. Results: Average percentage errorsobtained wereof 22.94% with the first filtering methodology, and 3.72% withthe second one. On identifying peaks and feet from PPG pulsesbefore filtering, error percentages obtained were of 24.26% and 48.39%, respectively, and once filtered error percentageslowered to 2.02% for peaks and 3.77% for feet. Conclusions: The attenuation of myokinetic noise in PPG pulses through LMS filtering, plusa preprocessing stage, allows increasingthe effectiveness onthe identification of peaks and feet from PPG pulses, which are of great importance for medical assessment.


Assuntos
Humanos , Fotopletismografia/métodos , Modelos Lineares , Artefatos
9.
Arq. bras. cardiol ; 105(3): 276-284, Sept. 2015. tab, ilus
Artigo em Inglês | LILACS | ID: lil-761507

RESUMO

Background:Diabetes affects approximately 250 million people in the world. Cardiovascular autonomic neuropathy is a common complication of diabetes that leads to severe postural hypotension, exercise intolerance, and increased incidence of silent myocardial infarction.Objective:To determine the variability of heart rate (HR) and systolic blood pressure (SBP) in recently diagnosed diabetic patients.Methods:The study included 30 patients with a diagnosis of type 2 diabetes of less than 2 years and 30 healthy controls. We used a Finapres® device to measure during five minutes beat-to-beat HR and blood pressure in three experimental conditions: supine position, standing position, and rhythmic breathing at 0.1 Hz. The results were analyzed in the time and frequency domains.Results:In the HR analysis, statistically significant differences were found in the time domain, specifically on short-term values such as standard deviation of NN intervals (SDNN), root mean square of successive differences (RMSSD), and number of pairs of successive NNs that differ by more than 50 ms (pNN50). In the BP analysis, there were no significant differences, but there was a sympathetic dominance in all three conditions. The baroreflex sensitivity (BRS) decreased in patients with early diabetes compared with healthy subjects during the standing maneuver.Conclusions:There is a decrease in HR variability in patients with early type 2 diabetes. No changes were observed in the BP analysis in the supine position, but there were changes in BRS with the standing maneuver, probably due to sympathetic hyperactivity.


Fundamento:O diabetes afeta aproximadamente 250 milhões de pessoas no mundo. A neuropatia autonômica cardiovascular é uma complicação comum do diabetes que leva à hipotensão postural grave, intolerância ao exercício e aumento na incidência de infarto do miocárdio silencioso.Objetivo:Determinar a variabilidade da frequência cardíaca (FC) e da pressão arterial sistólica (PAS) em pacientes diabéticos com diagnóstico recente.Métodos:O estudo incluiu 30 pacientes com diabetes tipo 2 diagnosticado há menos de 2 anos e 30 controles saudáveis. Nós utilizamos o dispositivo Finapres® para medir durante cinco minutos a FC batimento-a-batimento e a pressão arterial (PA) em três condições experimentais: posição supina, em pé e durante respiração rítmica na frequência de 0,1 Hz. Os resultados foram analisados nos domínios do tempo e da frequência.Resultados:Em relação à FC, foram encontradas diferenças estatisticamente significativas nos valores da análise do domínio do tempo, especificamente em valores determinados a curto prazo, tais como o desvio-padrão dos intervalos NN (DPNN), a raiz quadrada da média das diferenças sucessivas (RQMDS) para a FC e o número de pares de NNs sucessivos que diferem em mais de 50 ms (pNN50). Não houve diferença significativa na análise da PA, mas houve uma dominância simpática nas três condições. A sensibilidade do barorreflexo (SBR) esteve diminuída em pacientes com diabetes de início recente, em comparação aos indivíduos saudáveis durante execução da manobra na posição ortostática.Conclusões:Há uma diminuição na variabilidade da FC em pacientes com diabetes tipo 2 de início recente. Não foram observadas alterações na análise da PA na posição supina, mas a SBR apresentou mudança com a manobra em pé provavelmente causada por hiperatividade simpática.


Assuntos
Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pressão Sanguínea/fisiologia , /fisiopatologia , Frequência Cardíaca/fisiologia , Sistema Nervoso Autônomo/fisiopatologia , Barorreflexo/fisiologia , Estudos de Casos e Controles , Neuropatias Diabéticas/fisiopatologia , Postura/fisiologia , Fatores de Tempo
10.
Arch. cardiol. Méx ; 82(3): 197-203, jul.-sept. 2012. ilus
Artigo em Espanhol | LILACS | ID: lil-685329

RESUMO

Objetivo: Desarrollar un equipo de monitoreo de señales de electrocardiografía (ECG) y frecuencia cardiaca (FC) portátil, comunicado con un teléfono móvil mediante el protocolo de comunicación Bluetooth (BT), para su visualización en pantalla. Métodos: Se diseñó un sistema de monitoreo que en su sección electrónica realiza la adquisición de la señal de ECG, así como su amplificación, filtrado, conversión analógica a digital y transmisión por BT del ECG y la FC. Se desarrollaron dos programas para el sistema. El primero calcula la FC a través de la identificación del QRS, y envía las señales del ECG y FC al teléfono móvil. El segundo es una aplicación que permite adquirirlas y visualizarlas en la pantalla del móvil. Resultados: Se desarrolló un sistema electrónico portátil alimentado por una batería de 9 volts, de amplificación y ancho de banda que cumplen con los estándares internacionales, para monitoreo de ECG. La identificación del complejo QRS se realizó con el algoritmo de la segunda derivada, mientras que los programas realizados permiten enviar y recibir la información del ECG y la FC a través de BT, para visualizarlos en la pantalla del móvil. El monitoreo es factible hasta 15 m de distancia. Se probó en distintos móviles de Nokia®, Sony Ericsson® y Samsung®. Conclusiones: Este sistema muestra una alternativa de monitoreo móvil, con un teléfono por medio de BT y la programación en Java 2 Micro Edition (J2ME). Permite registrar el trazo del ECG y la FC, y puede implementarse en diferentes móviles.


Objective: To develop a portable signal monitoring equipment for electrocardiography (ECG) and heart rate (HR), communicated with a mobile phone using the Bluetooth (BT) communication protocol for display of the signal on screen. Methods: A monitoring system was designed in which the electronic section performs the ECG signal acquisition, as well as amplification, filtering, analog to digital conversion and transmission of the ECG and HR using BT. Two programs were developed for the system. The first one calculates HR through QRS identification and sends the ECG signals and HR to the mobile, and the second program is an application to acquire and display them on the mobile screen. Results: We developed a portable electronic system powered by a 9 volt battery, with amplification and bandwidth meeting the international standards for ECG monitoring. The QRS complex identification was performed using the second derivative algorithm, while the programs allow sending and receiving information from the ECG and HR via BT, and viewing it on the mobile screen. The monitoring is feasible within distances of 15 m and it has been tested in various mobiles telephones of brands Nokia®, Sony Ericsson® and Samsung®. Conclusions: This system shows an alternative for mobile monitoring using BT and Java 2 Micro Edition (J2ME) programming. It allows the register of the ECG trace and HR, and it can be implemented in different phones.


Assuntos
Humanos , Telefone Celular , Eletrocardiografia Ambulatorial/instrumentação , Frequência Cardíaca