Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Arterioscler Thromb Vasc Biol ; 35(9): 1945-53, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26183619

RESUMO

OBJECTIVE: Despite advances in stent technology for vascular interventions, in-stent restenosis (ISR) because of myointimal hyperplasia remains a major complication. APPROACH AND RESULTS: We investigated the regulatory role of microRNAs in myointimal hyperplasia/ISR, using a humanized animal model in which balloon-injured human internal mammary arteries with or without stenting were transplanted into Rowett nude rats, followed by microRNA profiling. miR-21 was the only significantly upregulated candidate. In addition, miR-21 expression was increased in human tissue samples from patients with ISR compared with coronary artery disease specimen. We systemically repressed miR-21 via intravenous fluorescein-tagged-locked nucleic acid-anti-miR-21 (anti-21) in our humanized myointimal hyperplasia model. As expected, suppression of vascular miR-21 correlated dose dependently with reduced luminal obliteration. Furthermore, anti-21 did not impede reendothelialization. However, systemic anti-miR-21 had substantial off-target effects, lowering miR-21 expression in liver, heart, lung, and kidney with concomitant increase in serum creatinine levels. We therefore assessed the feasibility of local miR-21 suppression using anti-21-coated stents. Compared with bare-metal stents, anti-21-coated stents effectively reduced ISR, whereas no significant off-target effects could be observed. CONCLUSION: This study demonstrates the efficacy of an anti-miR-coated stent for the reduction of ISR.


Assuntos
Anticorpos Antinucleares/farmacologia , Materiais Revestidos Biocompatíveis , Reestenose Coronária/prevenção & controle , Regulação da Expressão Gênica , Oclusão de Enxerto Vascular/prevenção & controle , MicroRNAs/genética , Animais , Proliferação de Células/efeitos dos fármacos , Reestenose Coronária/genética , Reestenose Coronária/metabolismo , Vasos Coronários/efeitos dos fármacos , Vasos Coronários/metabolismo , Vasos Coronários/ultraestrutura , Modelos Animais de Doenças , Stents Farmacológicos , Feminino , Oclusão de Enxerto Vascular/genética , Oclusão de Enxerto Vascular/metabolismo , Humanos , Masculino , MicroRNAs/biossíntese , MicroRNAs/imunologia , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Músculo Liso Vascular/efeitos dos fármacos , Músculo Liso Vascular/ultraestrutura , Neointima/metabolismo , Neointima/patologia , Desenho de Prótese , Ratos , Ratos Nus
2.
J Mater Sci Mater Med ; 26(10): 241, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26411437

RESUMO

Activated protein C (APC), an endogenous protein, inhibits inflammation and thrombosis and interrupts the coagulation cascade. Here, we investigated the effect of human recombinant APC on the development of neointimal hyperplasia in porcine coronary arteries. Yukon Choice bare metal stents were coated with 2.6 µg APC/mm(2). Under general anesthesia, APC-coated and bare stents were implanted in the left anterior descending and circumflex coronary arteries of 10 domestic pigs. During the 4-week follow-up, animals were treated with dual antiplatelet therapy and neointimal hyperplasia was evaluated via histology. Scanning electron microscopy indicated successful but unequal coating of stents with APC; nearly complete drug release occurred within 4 h. Enzyme-linked immunosorbent assay revealed that intracoronary stent implantation rapidly increased the levels of monocyte chemoattractant protein-1, an effect that was inhibited by APC release from the coated stent. Fibrin deposition and adventitial inflammation were significantly decreased 1 month after implanting APC-coated stents versus bare stents, paralleled by significantly smaller neointimal area (0.98 ± 0.92 vs. 1.44 ± 0.91 mm(2), P = 0.028), higher lumen area (3.47 ± 0.94 vs. 3.06 ± 0.91 mm(2), P = 0.046), and lower stenosis area (22.2 ± 21.2% vs. 32.1 ± 20.1%, P = 0.034). Endothelialization was complete with APC-coated but not bare (90%) stents. P-selectin immunostaining revealed significantly fewer activated endothelial cells in the neointima in the APC group (4.6 ± 1.9 vs. 11.6 ± 4.1%, P < 0.001). Thus, short exposure of coronary arteries to APC reduced inflammatory responses, neointimal proliferation, and in-stent restenosis, offering a promising therapy to improve clinical outcomes of coronary stenting. However, coating stents with APC for prolonged, controlled drug release remains technically challenging.


Assuntos
Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Proteína C/administração & dosagem , Animais , Materiais Revestidos Biocompatíveis/administração & dosagem , Materiais Revestidos Biocompatíveis/farmacocinética , Angiografia Coronária , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/patologia , Stents Farmacológicos/economia , Humanos , Masculino , Teste de Materiais , Modelos Animais , Neointima/diagnóstico por imagem , Neointima/patologia , Neointima/prevenção & controle , Proteína C/farmacocinética , Proteínas Recombinantes/administração & dosagem , Proteínas Recombinantes/farmacocinética , Sus scrofa
3.
Catheter Cardiovasc Interv ; 81(4): 698-708, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22581717

RESUMO

OBJECTIVE: The aim of this study was to assess the efficacy of stent-based delivery of succinobucol alone and in combination with rapamycin in a porcine coronary model. BACKGROUND: Current drugs and polymers used to coat coronary stents remain suboptimal in terms of long term efficacy and safety. Succinobucol is a novel derivative of probucol with improved antioxidant and anti-inflammatory properties. METHODS: Polymer-free Yukon stents were coated with 1% succinobucol (SucES), 2% rapamycin (RES), or 1% succinobucol plus 2% rapamycin solutions (SucRES) and compared with a bare metal stent (BMS). RESULTS: The in vivo release profile of SucES indicated drug release up to 28 days (60% drug released at 7 days); 41 stents (BMS, n = 11; SucES, n =10; RES, n = 10; SucRES, n = 10) were implanted in the coronary arteries of 17 pigs. After 28 days, mean neointimal thickness was 0.31 ± 0.14 mm for BMS, 0.51 ± 0.14 mm for SucES, 0.19 ± 0.11 mm for RES, and 0.36 ± 0.17 mm for SucRES (P < 0.05 for SucES vs. BMS). SucES increased inflammation and fibrin deposition compared with BMS (P < 0.05), whereas RES reduced inflammation compared with BMS (P < 0.05). CONCLUSION: In this model, stent-based delivery of 1% succinobucol using a polymer-free stent platform increased neointimal formation and inflammation following coronary stenting.


Assuntos
Fármacos Cardiovasculares/toxicidade , Vasos Coronários/efeitos dos fármacos , Stents Farmacológicos , Inflamação/induzido quimicamente , Intervenção Coronária Percutânea/instrumentação , Probucol/análogos & derivados , Animais , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/farmacocinética , Bovinos , Sobrevivência Celular/efeitos dos fármacos , Células Cultivadas , Vasos Coronários/metabolismo , Vasos Coronários/patologia , Relação Dose-Resposta a Droga , Quimioterapia Combinada , Células Endoteliais/efeitos dos fármacos , Células Endoteliais/patologia , Fibrina/metabolismo , Inflamação/patologia , Masculino , Metais , Modelos Animais , Músculo Liso Vascular/efeitos dos fármacos , Músculo Liso Vascular/patologia , Miócitos de Músculo Liso/efeitos dos fármacos , Miócitos de Músculo Liso/patologia , Neointima , Intervenção Coronária Percutânea/efeitos adversos , Probucol/administração & dosagem , Probucol/farmacocinética , Probucol/toxicidade , Desenho de Prótese , Sirolimo/administração & dosagem , Suínos
4.
Artigo em Inglês | MEDLINE | ID: mdl-19502256

RESUMO

INTRODUCTION: Orally administered angiotensin receptor antagonists administered after bare-metal stent implantation and even after drug-eluting stent implantation seem to lower in-stent restenosis rates.Whether valsartan-eluting stents are similarly effective was tested here in a first-in-man trial. MATERIALS AND METHODS: The efficacy of a polymer-free drug-eluting stent coated with 300 mcg valsartan was compared to a coating with a 2% rapamycin solution in small (

Assuntos
Tetrazóis/administração & dosagem , Valina/análogos & derivados , Idoso , Vasos Coronários , Stents Farmacológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sirolimo/administração & dosagem , Valina/administração & dosagem , Valsartana
5.
Arterioscler Thromb Vasc Biol ; 25(4): 748-53, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15681298

RESUMO

OBJECTIVE: The risk of in-stent restenosis can be considerably reduced by stents eluting cytostatic compounds. We created a novel drug-eluting stent system that includes several new features in the rapidly evolving field of stent-based drug delivery. METHODS AND RESULTS: The aim of the present study was the preclinical evaluation of a stent-coating system permitting individual, on-site coating of stents with a unique microporous surface allowing for individualizable, dose-adjustable, and multiple coatings with identical or various compounds, designated ISAR (individualizable drug-eluting stent system to abrogate restenosis). Stents were coated with 0.75% rapamycin solution, and high-performance liquid chromatography (HPLC)-based determination of drug release profile indicated drug release for >21 days. Rapamycin-eluting microporous (REMP) stents implanted in porcine coronary arteries were safe. To determine the efficacy of REMP stents, this novel drug-eluting stent platform was compared with the standard sirolimus-eluting stent. At 30 days, in-stent neointima formation in porcine coronary arteries was similar in both groups, yielding a significant decrease of neointimal area and injury-dependent neointimal thickness compared with bare-metal stents. CONCLUSIONS: The ISAR drug-eluting stent platform as a novel concept for stent coating allows for a safe, effective, on-site stent coating process, thus justifying further clinical evaluation to decrease in-stent restenosis in humans.


Assuntos
Antibióticos Antineoplásicos/farmacocinética , Materiais Revestidos Biocompatíveis , Reestenose Coronária/prevenção & controle , Sirolimo/farmacocinética , Stents , Animais , Antibióticos Antineoplásicos/administração & dosagem , Reestenose Coronária/patologia , Vasos Coronários/patologia , Modelos Animais de Doenças , Humanos , Técnicas In Vitro , Sirolimo/administração & dosagem , Suínos , Túnica Íntima/patologia
6.
Cardiovasc Intervent Radiol ; 36(3): 756-63, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23435745

RESUMO

PURPOSE: The efficacy of drug-eluting balloons has been demonstrated in clinical trials. The drug predominantly used is paclitaxel because of its lipophilic properties and the rapid onset of action. The aim of the investigation was to evaluate the feasibility and efficacy of an alternative balloon coating with rapamycin that can be applied on site. METHODS: The balloon coating (3.0/18 and 3.0/12 mm, Cathy No. 4, Translumina GmbH) with rapamycin was conducted with a coating machine (Translumina GmbH). Concentrations were 2, 2 × 2, 3, and 4 %. Measurements regarding the amount of substance released to the vessel wall were carried out on explanted porcine coronaries by means of ultraviolet and visible-light spectroscopy. Inflation time varied between 30 and 120 s. The biological effect of the coating was evaluated in a porcine peripheral overstretch and stent implantation model. RESULTS: The amount of rapamycin on the balloon surface ranged from 558 ± 108 µg for the 2 % solution to 1,441 ± 228 µg in the 4 % solution. An amount of 95 ± 63-193 ± 113 µg was released into the vessel wall. The quantitative measurements of the angiographic examinations 4 weeks after treatment revealed a reduction of diameter stenosis from 20.6 ± 17.4 % in the control group to 11.6 ± 5.5 % in the drug-eluting balloon group. CONCLUSION: A balloon coating with rapamycin omitting an excipient is possible with a dose-adjustable coating machine. However, the biological effects are moderate, which make further optimization of the coating process and evaluation of appropriate excipients necessary.


Assuntos
Angioplastia Coronária com Balão , Sistemas de Liberação de Medicamentos , Sirolimo/farmacologia , Animais , Angiografia Coronária , Estudos de Viabilidade , Imuno-Histoquímica , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Suínos
7.
J Vis Exp ; (63): e3663, 2012 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-22617624

RESUMO

Preclinical in vivo research models to investigate pathobiological and pathophysiological processes in the development of intimal hyperplasia after vessel stenting are crucial for translational approaches (1,2). The commonly used animal models include mice, rats, rabbits, and pigs (3-5). However, the translation of these models into clinical settings remains difficult, since those biological processes are already studied in animal vessels but never performed before in human research models (6,7). In this video we demonstrate a new humanized model to overcome this translational gap. The shown procedure is reproducible, easy, and fast to perform and is suitable to study the development of intimal hyperplasia and the applicability of diverse stents. This video shows how to perform the stent technique in human vessels followed by transplantation into immunodeficient rats, and identifies the origin of proliferating cells as human.


Assuntos
Oclusão de Enxerto Vascular/etiologia , Artéria Torácica Interna/transplante , Stents , Enxerto Vascular/métodos , Animais , Processos de Crescimento Celular/fisiologia , Oclusão de Enxerto Vascular/patologia , Humanos , Artéria Torácica Interna/citologia , Ratos , Ratos Nus , Transplante Heterólogo
8.
Atherosclerosis ; 200(1): 126-34, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18295768

RESUMO

BACKGROUND: We here describe the pharmacological characteristic, in vivo efficacy, and in vitro mechanisms of a polymer-free leflunomide eluting stent in comparison to its rapamycin-coated equivalent. METHODS: Stents were coated with 40 mM solutions of leflunomide (L) or rapamycin (R) or were left uncoated (BM). Neointima formation was assessed 6 weeks after implantation into Sprague Dawley rats by optical coherence tomographies (OCT) and histopathology. In vitro proliferation assays were performed using isolated endothelial and smooth-muscle-cells from Sprague Dawley rats to investigate the cell-specific pharmacokinetic effect of leflunomide and rapamycin. RESULTS: HPLC-based drug release kinetics revealed a similar profile with 90% of the drug being released after 12.1+/-0.2 (L) and 13.0+/-0.2 days (R). After 6 weeks, OCTs showed that in-stent luminal obliteration was less for the coated stents (L:12.0+/-9.4%, R:13.3+/-13.1%) when compared to identical bare metal stents (BM:26.4+/-4.7%; p

Assuntos
Stents Farmacológicos , Inibidores Enzimáticos/farmacologia , Isoxazóis/farmacologia , Túnica Íntima/efeitos dos fármacos , Túnica Média/efeitos dos fármacos , Animais , Células Cultivadas , Células Endoteliais/efeitos dos fármacos , Inibidores Enzimáticos/farmacocinética , Humanos , Isoxazóis/farmacocinética , Leflunomida , Miócitos de Músculo Liso/efeitos dos fármacos , Ratos , Ratos Sprague-Dawley , Sirolimo/farmacocinética , Sirolimo/farmacologia , Tomografia de Coerência Óptica , Túnica Íntima/patologia , Túnica Média/patologia
9.
Eur Heart J ; 26(15): 1475-81, 2005 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15975990

RESUMO

AIMS: Drug-eluting stents (DES) represent a major advance in interventional cardiology. Along with the success shown, current DES also present limitations related to the presence of polymer-coating, fixed drug, and dose used. With the ISAR (Individualized Drug-Eluting Stent System to Abrogate Restenosis) project, a DES system has been developed that permits individualized choice of the drug and dose to use for the given patient. The objective of this prospective dose finding study was to assess the feasibility, safety, and efficacy of a polymer-free on-site stent coating with increasing rapamycin doses. METHODS AND RESULTS: In this dose finding study, 602 patients were sequentially enrolled in four groups: microporous bare metal stent (BMS), DES stents coated with a 0.5, 1.0, and 2.0% rapamycin solution. The angiographic in-segment restenosis rate at follow-up angiography was the primary study endpoint. In-segment restenosis was significantly reduced from 25.9% with BMS to 18.9, 17.2, and 14.7% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.024). Similarly, the need for target lesion revascularization at 1 year follow-up was reduced from 21.5% with BMS to 16.4, 12.6, and 8.8% with 0.5, 1.0, and 2.0% rapamycin-eluting stents, respectively (P=0.006). CONCLUSION: The placement of polymer-free stents coated on-site with rapamycin is feasible and safe. Furthermore, a dose-dependent efficacy in restenosis prevention is achievable with this new DES concept.


Assuntos
Reestenose Coronária/prevenção & controle , Imunossupressores/administração & dosagem , Sirolimo/administração & dosagem , Stents , Idoso , Relação Dose-Resposta a Droga , Implantes de Medicamento , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Polímeros , Estudos Prospectivos , Análise de Regressão , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA