Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
Arch Orthop Trauma Surg ; 142(1): 139-144, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33130933

RESUMO

BACKGROUND: Elective implant removal (IR) accounts for up to 30% of all orthopaedic surgeries. While there is general acceptance about the need of implant removal for obvious reasons, such as infections or implant failure, little is known about the beneficial aspects in cases of minor reasons such as patients' wish for IR. Therefore, we initiated this study to define patients' benefit of elective implant removal following plate osteosynthesis of displaced clavicle fractures. PATIENTS AND METHODS: Prospective evaluation of patients was conducted before implant removal and 6 weeks postoperative. Subjective and objective criteria included pain rating on a visual analogue scale (VAS) and active range of motion (ROM) pre- and 6 weeks postoperative. Functional scoring included Constant-Murley Score, DASH (Disabilities of Arm, Shoulder and Hand Score), MSQ (Munich Shoulder Questionnaire) and SPADI (Shoulder Pain and Disability Index). RESULTS: 37 patients were prospectively enrolled in this study and implant removal was performed after 16 ± 6.1 months. No re-fractures nor other complications were detected during routine follow up. Functional outcome increased through all scores (Constant score 73.3 ± 14.6 preoperative to 87.4 ± 12.0 postoperative (p = 0.000), MSQ 85.0 ± 7.3 preoperative to 91.8 ± 9.0 postoperative (p = 0.005), DASH Score 7.4 ± 8.2 preoperative to 5.7 ± 9.5 postoperative (p = 0.414), SPADI 93.4 ± 6.6 preoperative to 94.0 ± 10.1 postoperative (p = 0.734). CONCLUSIONS: Discomfort during daily activities or performing sports as well as limited range of motion were the main reasons for patients' wish for implant removal. We found increased functional outcome parameters and decreased irritation after implant removal. Therefore we suggest implant removal in case of patients' wish and completed fracture consolidation. TRIAL REGISTRATION: Trial registration no: NCT04343118, Retrospective registered: www.clinicaltrials.gov .


Assuntos
Clavícula , Fraturas Ósseas , Placas Ósseas , Clavícula/cirurgia , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Humanos , Estudos Retrospectivos , Resultado do Tratamento
2.
BMC Musculoskelet Disord ; 22(1): 905, 2021 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-34706701

RESUMO

BACKGROUND: Treatment of medial clavicle fractures is still controversially discussed in the community of upper extremity surgeons. An increasing number of symptomatic non-unions following conservative treatment of displaced fractures led to the development of various surgical approaches. Aim of this study was to evaluate the clinical and radiological outcome following operative treatment of displaced medial end clavicle fractures. METHODS: Patients who presented with a displaced fracture of the medial clavicle between September 2012 and December 2019 were retrospectively enrolled in this study. All patients were operatively treated with open reduction and internal fixation (ORIF) using an anatomically precontoured locking compression plate (LCP) originally designed for the lateral clavicle (Synthes®, Umkirch, Germany). Functional outcome was recorded using the American Shoulder and Elbow Surgeons (ASES) Score, the Munich Shoulder Questionnaire (MSQ), Shoulder Pain and Disability Index (SPADI) and Constant Score. RESULTS: Overall 18 patients with a mean age of 54.5 ± 23.5 years suffering from a displaced fracture of the medial clavicle were identified. The mean follow-up was 40.9 ± 26.2 months. The mean ASES accounted for 88.3 ± 20.8 points, the mean MSQ was 83.1 ± 21.7 points, the mean SPADI was 85.6 ± 22.5 and a mean normative age- and sex-specific Constant Score of 77.5 ± 19.1 points resulted. No minor or major complications were observed. Radiologic fracture consolidation was achieved in all patients after a mean of 6.4 months. CONCLUSION: Surgical treatment of displaced medial clavicle fractures using an anatomically precontoured locking plate originally designed for the lateral clavicle led to very good to excellent clinical and functional results. TRIAL REGISTRATION: No: DRKS00024813 , retrospectively registered 19.03.2021 ( www.drks.de ).


Assuntos
Clavícula , Fraturas Ósseas , Adulto , Idoso , Placas Ósseas , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Redução Aberta , Estudos Retrospectivos , Resultado do Tratamento
3.
Int Orthop ; 42(6): 1371-1377, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29353316

RESUMO

INTRODUCTION: Successful treatment of periprosthetic shoulder fractures depends on the right strategy, starting with a well-structured classification of the fracture. Unfortunately, clinically relevant factors for treatment planning are missing in the pre-existing classifications. Therefore, the aim of the present study was to describe a new specific classification system for periprosthetic shoulder fractures including a structured treatment algorithm for this important fragility fracture issue. METHODS: The classification was established, focussing on five relevant items, naming the prosthesis type, the fracture localisation, the rotator cuff status, the anatomical fracture region and the stability of the implant. After considering each single item, the individual treatment concept can be assessed in one last step. To evaluate the introduced classification, a retrospective analysis of pre- and post-operative data of patients, treated with periprosthetic shoulder fractures, was conducted by two board certified trauma surgery consultants. RESULTS: The data of 19 patients (8 male, 11 female) with a mean age of 74 ± five years have been analysed in our study. The suggested treatment algorithm was proven to be reliable, detected by good clinical outcome in 15 of 16 (94%) cases, where the suggested treatment was maintained. Only one case resulted in poor outcome due to post-operative wound infection and had to be revised. CONCLUSIONS: The newly developed six-step classification is easy to utilise and extends the pre-existing classification systems in terms of clinically-relevant information. This classification should serve as a simple tool for the surgeon to consider the optimal treatment for his patients.


Assuntos
Fraturas Periprotéticas/classificação , Fraturas do Ombro/classificação , Prótese de Ombro/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Artroplastia/métodos , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas Periprotéticas/cirurgia , Estudos Retrospectivos , Fraturas do Ombro/cirurgia , Articulação do Ombro/cirurgia
4.
BMC Musculoskelet Disord ; 18(1): 547, 2017 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-29282027

RESUMO

BACKGROUND: Management of distal humeral fractures remains to be one of the most challenging aspects in trauma surgery. Low profile plating systems with variable angle screw fixation represent a crucial advancement to the established angular stable locking plates with considerable attention in current research. The aim of the prospective randomized trial was to review the preliminary results and patients' outcome following treatment with these newly developed implants and to rule out potential differences in fracture treatment of two different plating systems. METHODS: Twenty patients with distal humeral fractures (AO 13-A1 - AO 13-C3) were included in the current study since 2014. After completing the randomization plan, patients were distributed into two groups for different variable angle locking plates (DePuy Synthes® VA-LCP vs. Medartis® Aptus Elbow). Functional elbow scoring (ROM, MEPS, QuickDASH) served as primary outcome parameter, while radiological fracture consolidation served as secondary outcome parameter. Follow-ups were conducted 6 weeks, 12 weeks, 6 months and 12 months after the operation. RESULTS: Seventeen of 20 patients (85%) concluded all follow-up examinations. Postoperative elbow extension deficiencies showed significant differences between the two groups in all follow-up examinations with a mean of Ø 18 +/- 7.4 degrees in the DePuy Synthes® VA-LCP group compared to a mean of Ø 6.5 +/- 7.5 degrees in the Medartis® Aptus Elbow group (p = 0.002) 12 months postoperatively. Functional scoring showed a disparate pattern. The Medartis® Aptus Elbow group achieved significantly better MEP scores during follow-up. However, the analysis of the QuickDash revealed better results of the DePuy Synthes® VA-LCP group in the first half and better results of the Medartis® Aptus Elbow group in the second half of the follow-up examination instead. CONCLUSIONS: Considering the complexity of distal humeral fractures, the usage of anatomically preshaped low profile variable angle locking plates for operative treatment leads to good clinical results. Even though there might be some advances of the Medartis® Aptus Elbow plating system concerning postoperative ROM and elbow function, a consistent difference in the overall clinical outcome between the two plating systems could not be detected. TRIAL REGISTRATION: https://clinicaltrials.gov/ct2/show/NCT03272490 Retrospectively Registered 1. September 2017.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/instrumentação , Fraturas do Úmero/diagnóstico por imagem , Fraturas do Úmero/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Estudos Prospectivos , Resultado do Tratamento
5.
BMC Musculoskelet Disord ; 18(1): 129, 2017 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-28356152

RESUMO

BACKGROUND: Treatment of clavicular non- and malunion is still challenging. Current surgical procedures often result in frustrating functional outcome along with high-grade subjective impairment and increased rates of revision surgery. However, the combination of biological augmentation with vital bone graft and a biomechanically sufficient fixation system seems to be a promising concept of treatment. METHODS: In this retrospective study, 14 patients with a mean age of 44 years (26-67 years) suffering from non-union (n = 11) and/or malunion (n = 3) of the clavicle were enrolled. All patients were surgically treated using an anatomical precontoured locking compression plate (LCP) and autologous iliac crest bone graft. Functional outcome was assessed using the age- and sex-specific relative Constant Score. RESULTS: Mean follow-up was 27 months (range 12-44 months). The relative Constant Score significantly improved from preoperative 61 ± 8 (43-72) to 82 ± 10 (65-100) points at the final follow-up examination (p < 0.05). All patients showed bony union radiographically. One patient presented with a re-fracture of the clavicle nearly 3 years after revision surgery and 5 weeks after implant removal. Secondary fractures at the donor site of the anterior superior iliac spine were recorded in two patients. CONCLUSIONS: Iliac crest bone graft and anatomic locking plate fixation allow for a safe and adequate stabilization and radiographical bony union in non- and malunions of the clavicle with a high degree of patient satisfaction. However, secondary fractures of the anterior superior iliac spine constitute relevant complications and the time of hardware removal should be considered carefully.


Assuntos
Placas Ósseas/tendências , Transplante Ósseo , Clavícula/diagnóstico por imagem , Clavícula/cirurgia , Ílio/transplante , Reoperação/instrumentação , Adulto , Idoso , Transplante Ósseo/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Estudos Retrospectivos , Resultado do Tratamento
6.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2230-2236, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25982625

RESUMO

PURPOSE: To develop and validate an elbow self-assessment score considering subjective as well as objective parameters. METHODS: Each scale of the American Shoulder and Elbow Surgeons-Elbow Score, the Broberg and Morrey rating system (BMS), the Patient-Rated Elbow Evaluation (PREE) Questionnaire, the Mayo Elbow Performance Score (MEPS), the Oxford Elbow Score (OES) and the Quick Disabilities of the Arm, Shoulder and Hand (Quick-DASH) was analysed, and after matching of the general topics, the dedicated items underwent a fusion to the final ESAS's item and a score containing 22 items was created. In a prospective clinical study, validity, reliability and responsiveness in physically active patients with traumatic as well as degenerative elbow disorders were evaluated. RESULTS: Validation study included 103 patients (48 women, 55 men; mean age 43 years). A high test-retest reliability was found with intraclass correlation coefficients of at least 0.71. Construct validity and responsiveness were confirmed by correlation coefficients of -0.80 to -0.84 and 0.72-0.84 (p <0.05). Correlation coefficients of the ESAS and well-established elbow rating systems BMS, PREE, MEPS, OES and Quick-DASH were between 0.70 and 0.90 (p < 0.05). CONCLUSIONS: With this novel Elbow Self-Assessment Score (ESAS), a valid and reliable instrument for a qualitative self-assessment of subjective and objective parameters (e.g. range of motion) of the elbow joint is demonstrated. Quantitative measurement of elbow function may not longer be limited to specific elbow disorders or patient groups. The ESAS seems to allow for a broad application in clinical research studying elbow patients and may facilitate the comparison of treatment results in elbow disorders. The treatment efficacy can be easily evaluated, and treatment concepts could be reviewed and revised. LEVEL OF EVIDENCE: Diagnostic study, Level III.


Assuntos
Lesões no Cotovelo , Cotovelo/cirurgia , Artropatias/cirurgia , Medidas de Resultados Relatados pelo Paciente , Inquéritos e Questionários , Adulto , Cotovelo/fisiopatologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Autoavaliação (Psicologia) , Resultado do Tratamento
7.
Knee Surg Sports Traumatol Arthrosc ; 25(10): 3237-3241, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26590565

RESUMO

PURPOSE: To detect concomitant intra-articular glenohumeral injuries, in acute displaced fractures of the lateral clavicle, initially missed due to unfeasible clinical evaluation of the acutely injured shoulder. METHODS: All patients suffering from an acute displaced lateral clavicle fracture with indication to surgical treatment underwent diagnostic shoulder arthroscopy prior to open reduction and internal fixation. In case of therapy-relevant intra-articular glenohumeral injuries, subsequent surgical treatment was performed. RESULTS: Intra-articular injuries were found in 13 of 28 patients (46.4 %) with initially suspected isolated lateral clavicle fracture. Additional surgical treatment was performed in 8 of 28 cases (28.6 %). Superior labral anterior-posterior (SLAP) lesions were observed in 4 of 28 patients (14.3 %; SLAP II a: 1; II b: 1; III: 1; and IV: 1). Lesions of the pulley system were found in 3 of 28 patients (10.7 %; Habermeyer III°). One partial articular supraspinatus tendon avulsion lesion (3.6 %) and one lesion of the subscapularis tendon (3.6 %; Fox and Romeo II°) were observed. CONCLUSIONS: Traumatic concomitant glenohumeral injuries in lateral clavicle fractures seem to be more frequent than expected in general. Subsequent surgical treatment of these formerly missed but therapy-relevant injuries may increase functional outcome and reduce complication rate. LEVEL OF EVIDENCE: IV.


Assuntos
Artroscopia/estatística & dados numéricos , Clavícula/lesões , Lesões do Ombro , Lesões do Ombro/diagnóstico , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fixação Interna de Fraturas , Humanos , Cápsula Articular , Masculino , Pessoa de Meia-Idade , Redução Aberta , Estudos Prospectivos , Manguito Rotador , Ombro , Lesões do Ombro/terapia , Adulto Jovem
8.
Arch Orthop Trauma Surg ; 137(6): 789-795, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28432459

RESUMO

INTRODUCTION: For comminuted and displaced fractures of the radial head open reduction and internal fixation (ORIF) is recommended nowadays as the treatment of choice. Due to the development of locking plates the possibilities of ORIF in complex fracture types were extended. The purpose of this retrospective survey therefore was to review the preliminary subjective and objective results in patients treated by anatomically preshaped locked plating. A reliable fracture healing for these recently introduced plating devices was hypothesized. MATERIALS AND METHODS: Subjective and objective criteria included patient's satisfaction, pain rating on a visual analogue scale (VAS) and active range of motion (ROM) compared to the contralateral armside. Functional scoring included the Morrey elbow performance score (MEPS), the QuickDASH and the elbow self-assessment score (ESAS). Furthermore, follow-up radiographs were reviewed. RESULTS: Between 2011 and 2014 a total of 24 patients were managed with ORIF using anatomically preshaped low-profile locking plates. All patients had suffered from comminuted radial head fractures (type III-IV according to Mason classification). Twenty of 24 patients returned for follow-up examination after a mean of 30 months (range 18-53 months). Patients' satisfaction was rated as highly satisfied in 17 cases and satisfied in 3 cases. An unrestricted ROM for extension-flexion arc and pronation-supination arc was rated in 10 cases. Minor ROM deficiencies with a 5° limited extension compared to the contralateral side was evaluated in 6 cases. Only four patients were rated with and extension and supination deficiency of 10°, one of whom with an additional pronation deficiency of 10°. The calculated MEPS was Ø 98 ± 4 (range 85-100), and the QuickDASH was Ø 3 ± 6 (range 0-21). The ESAS was completed by 18 patients with a mean of Ø 96.54 ± 2.95 (range 94-100) indicating a non-restricted elbow function. CONCLUSIONS: The treatment of comminuted radial head fractures using anatomically preshaped locking radial head plates represents a reliable and safe surgical approach, leading to good to excellent functional results. Being aware of the importance of the radial head for elbow stability, open reduction and internal fixation should be preferred prior to radial head resection or replacement in complex radial head fractures. Further trials with a higher number of patients are needed to confirm the advantages of preshaped radial head plates.


Assuntos
Placas Ósseas , Parafusos Ósseos , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Fraturas do Rádio/cirurgia , Adulto , Idoso , Feminino , Seguimentos , Consolidação da Fratura , Fraturas Cominutivas/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Radiografia , Fraturas do Rádio/diagnóstico , Estudos Retrospectivos , Fatores de Tempo
9.
BMC Musculoskelet Disord ; 17: 167, 2016 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-27079377

RESUMO

BACKGROUND: Although self-assessment questionnaires for the wrist joint are numerous, most validation studies focus on a specific pathology and patient collectives. In addition the available questionnaires focus on subjective parameters such as pain, usual and specific activities but the range of motion (ROM) as an essential objective parameter in wrist disorders is rarely considered. Therefore the purpose of the presented study was to develop and validate a new universally applicable self-assessment score, the Munich Wrist Questionnaire (MWQ), which allows for the assessment of subjective as well as objective parameters of the wrist joint. METHODS: The MWQ consists of 16 items addressing three domains: pain, work and activities of daily living and wrist function including range of motion and grip strength. In a prospective clinical study validity, reliability and responsiveness of the MWQ of physical active patients were evaluated. RESULTS: Validation study included 100 patients (mean age 41 years, SD 16.3 years; range, 18-77 years). Test-retest reliability was substantial, with intraclass correlation coefficients ranging from 0.75 to 0.83 for the three domains. Construct validity and responsiveness were confirmed by correlation coefficients of at least 0.86 for construct validity and for responsiveness ranging from 0.61 to 0.65. CONCLUSIONS: The MWQ presents a valid and reliable instrument for a qualitative self-assessment of subjective and objective parameters (e.g. range of motion) of the wrist joint. Quantitative measurement of wrist function may not longer be limited to specific wrist disorders or patient groups. The MWQ seems to allow for a broad application in clinical research and may facilitate the comparison of treatment results in wrist disorders.


Assuntos
Medidas de Resultados Relatados pelo Paciente , Inquéritos e Questionários/normas , Traumatismos do Punho/diagnóstico , Articulação do Punho/fisiologia , Adolescente , Adulto , Idoso , Estudos de Coortes , Feminino , Alemanha/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Amplitude de Movimento Articular/fisiologia , Traumatismos do Punho/epidemiologia , Traumatismos do Punho/fisiopatologia , Adulto Jovem
10.
BMC Musculoskelet Disord ; 17(1): 482, 2016 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-27855665

RESUMO

BACKGROUND: The aim of this study was to evaluate potential benefits of a new diagnostic software prototype (Trauma Viewer, TV) automatically reformatting computed tomography (CT) data on diagnostic speed and quality, compared to CT-image data evaluation using a conventional CT console. METHODS: Multiple trauma CT data sets were analysed by one expert radiology and one expert traumatology fellow independently twice, once using the TV and once using the secondary conventional CT console placed in the CT control room. Actual analysis time and precision of diagnoses assessment were evaluated. The TV and CT-console results were compared respectively, but also a comparison to the initial multiple trauma CT reports assessed by emergency radiology fellows considered as the gold standard was performed. Finally, design and function of the Trauma Viewer were evaluated in a descriptive manner. RESULTS: CT data sets of 30 multiple trauma patients were enrolled. Mean time needed for analysis of one CT dataset was 2.43 min using the CT console and 3.58 min using the TV respectively. Thus, secondary conventional CT console analysis was on average 1.15 min shorter compared to the TV analysis. Both readers missed a total of 11 diagnoses using the secondary conventional CT console compared to 12 missed diagnoses using the TV. However, none of these overlooked diagnoses resulted in an Abbreviated Injury Scale (AIS) > 2 corresponding to life threatening injuries. CONCLUSIONS: Even though it took the two expert fellows a little longer to analyse the CT scans on the prototype TV compared to the CT console, which can be explained by the new user interface of the TV, our preliminary results demonstrate that, after further development, the TV might serve as a new diagnostic feature in the trauma room management. Its high potential to improve time and quality of CT-based diagnoses might help in fast decision making regarding treatment of severely injured patients.


Assuntos
Serviço Hospitalar de Emergência , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Ferimentos e Lesões/diagnóstico por imagem , Humanos , Software , Fatores de Tempo
11.
BMC Musculoskelet Disord ; 17(1): 498, 2016 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-27955655

RESUMO

BACKGROUND: Compromised bone stock and heavily impaired structural integrity after multiple endoprosthetic revision surgeries can lead to a comparable condition as encountered in musculoskeletal tumor surgery. Total femoral replacement (TFR) can restore femoral integrity and allow patients to resume ambulation. Even though several authors reported their results of TFR, so far many questions are still on debate: Which patients are at risk to experience low functional outcome? Do complications and clinical outcome after TFR depend on the indication for the surgery (e.g. periprosthetic fractures or aseptic loosening) or the age of the patients? The purpose of the present study was to compare complication rates after TFR performed with modular total femur prosthesis MML (Fa. ESKA/Orthodynamics) in patients without malignant disease. METHODS: We conducted a retrospective chart review and functional investigation of patients treated with a TFR for non-oncologic conditions from 1995 to 2015 and a minimum follow-up of 2 years. Complications were recorded according to the Henderson-Classification; outcome was evaluated with established clinical scores. The indication for TFR was periprosthetic fracture (Group A, n = 11) or aseptic loosening (Group B, n = 7) with massive bone defect of the femur deemed unsuitable for conventional arthroplastic or biologic reconstruction. RESULTS: Eighteen patients matched the inclusion criteria and could be investigated clinically after a mean follow-up of 80 months (range: 28-132). Before TFA, all patients had previously undergone multiple operations (range: 1-8). The overall failure rate for any reason was 72% (n = 13/18), leading to a total of 37 surgical revisions with total exchange of TFR in 22% (n = 4/18). Most common failure mechanism was Type I (soft tissue), followed by Type IV (infection) and Type III (mechanical failure). According to Enneking's functional evaluation method (MSTS-Score), the function ranged from 1 to 15 with a mean of 10 ± 4 out of 30. CONCLUSION: TFR is a salvage procedure to restore mechanical integrity and regain functional ability after extensive femoral bone loss. Outcome of the patients in the present study did mainly depend on the age at reconstruction and not on the indication for TFR.


Assuntos
Fêmur/cirurgia , Salvamento de Membro/efeitos adversos , Procedimentos de Cirurgia Plástica/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Falha de Prótese , Reoperação/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Feminino , Fêmur/patologia , Seguimentos , Humanos , Salvamento de Membro/métodos , Masculino , Fraturas Periprotéticas/cirurgia , Complicações Pós-Operatórias/etiologia , Desenho de Prótese , Radiografia , Procedimentos de Cirurgia Plástica/métodos , Estudos Retrospectivos , Resultado do Tratamento
12.
Mediators Inflamm ; 2015: 197150, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26568661

RESUMO

In traumatic brain injury (TBI) the analysis of neuroinflammatory mechanisms gained increasing interest. In this context certain immunocompetent cells might play an important role. Interestingly, in the actual literature there exist only a few studies focusing on the role of monocytes and granulocytes in TBI patients. In this regard it has recently reported that the choroid plexus represents an early, selective barrier for leukocytes after brain injury. Therefore the aim of this study was to evaluate the very early dynamics of CD14+ monocytes and CD15+ granulocyte in CSF of patients following severe TBI with regard to the integrity of the BBB. Cytometric flow analysis was performed to analyze the CD14+ monocyte and CD15+ granulocyte population in CSF of TBI patients. The ratio of CSF and serum albumin as a measure for the BBB's integrity was assessed in parallel. CSF samples of patients receiving lumbar puncture for elective surgery were obtained as controls. Overall 15 patients following severe TBI were enrolled. 10 patients were examined as controls. In patients, the monocyte population as well as the granulocyte population was significantly increased within 72 hours after TBI. The BBB's integrity did not have a significant influence on the cell count in the CSF.


Assuntos
Lesões Encefálicas/imunologia , Granulócitos/imunologia , Antígenos CD15/análise , Receptores de Lipopolissacarídeos/análise , Monócitos/imunologia , Adulto , Barreira Hematoencefálica , Lesões Encefálicas/líquido cefalorraquidiano , Estudos de Coortes , Feminino , Humanos , Contagem de Leucócitos , Masculino , Pessoa de Meia-Idade
13.
BMC Musculoskelet Disord ; 16: 128, 2015 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-26018526

RESUMO

BACKGROUND: Fractures of the clavicle present very common injuries with a peak of incidence in young active patients. Recently published randomized clinical trials demonstrated an improved functional outcome and a lower rate of nonunions in comparison to non-operative treatment. Anterior chest wall numbness due to injury of the supraclavicular nerve and postoperative pain constitute common surgery related complications in plate fixation of displaced clavicle fractures. We recently developed a technique for mini open plating (MOP) of the clavicle to reduce postoperative numbness and pain. The purpose of this study was to analyze the size of anterior chest wall numbness and the intensity of postoperative pain in MOP in comparison to conventional open plating (COP) of clavicle fractures. METHODS: 24 patients (mean age 38.2 ± 14.2 yrs.) with a displaced fracture of the clavicle (Orthopaedic Trauma Association B1.2-C1.2) surgically treated using a locking compression plate (LCP) were enrolled. 12 patients underwent MOP and another 12 patients COP. Anterior chest wall numbness was measured with a transparency grid on the second postoperative day and at the six months follow-up. Postoperative pain was evaluated using the Visual Analog Scale (VAS). RESULTS: Mean ratio of skin incision length to plate length was 0.61 ± 0.04 in the MOP group and 0.85 ± 0.06 in the COP group (p < 0.05). Mean ratio of the area of anterior chest wall numbness to plate length was postoperative 7.6 ± 5.9 (six months follow-up 4.7 ± 3.9) in the MOP group and 22.1 ± 19.1 (16.9 ± 14.1) in the COP group (p < 0.05). Mean VAS was 2.6 ± 1.4 points in the MOP group and 3.4 ± 1.6 points in the COP group (p = 0.20). CONCLUSIONS: In our study, MOP significantly reduced anterior chest wall numbness in comparison to a conventional open approach postoperative as well as at the six months follow-up. Postoperative pain tended to be lower in the MOP group, however this difference was not statistically significant. TRIAL REGISTRATION: ClinicalTrials.gov NCT02247778 . Registered 21 September 2014.


Assuntos
Placas Ósseas , Clavícula/cirurgia , Fixação Interna de Fraturas/instrumentação , Fraturas Ósseas/cirurgia , Hipestesia/prevenção & controle , Dor Pós-Operatória/prevenção & controle , Parede Torácica/inervação , Adulto , Idoso , Clavícula/diagnóstico por imagem , Clavícula/lesões , Feminino , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/diagnóstico , Alemanha , Humanos , Hipestesia/diagnóstico , Hipestesia/etiologia , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Radiografia , Resultado do Tratamento , Adulto Jovem
14.
Arthroscopy ; 31(8): 1522-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25882181

RESUMO

PURPOSE: To develop and validate an all-purpose patient-reported outcome questionnaire for a patient-based follow-up examination regarding knee disorders. METHODS: Each scale of the Knee Injury and Osteoarthritis Outcome Score (KOOS), International Knee Documentation Committee (IKDC) score, Lysholm knee score, Western Ontario Meniscal Evaluation Tool (WOMET) score, and Tegner score was analyzed, and after matching of the general topics, the dedicated items underwent a fusion to the final Munich Knee Questionnaire (MKQ) item and a score comprising 33 items was created. In a prospective clinical study, we evaluated validity, reliability, and responsiveness in 152 physical active patients (75 women and 77 men; mean age, 47 years) with traumatic as well as degenerative knee disorders. RESULTS: Test-retest reliability was substantial, with intraclass correlation coefficients of at least 0.91. Construct validity and responsiveness were confirmed by correlation coefficients of 0.78 to 0.86 (P = .01) and 0.41 to 0.71, respectively. Correlation coefficients of the original scores (KOOS, IKDC, Lysholm, WOMET, and Tegner) and the scores calculated from the MKQ were between 0.80 and 0.91 (P = .01). CONCLUSIONS: The MKQ is a reliable and valid patient-reported outcome questionnaire for assessing knee function. It seems to enable the calculation of the original items of the KOOS, IKDC score, Lysholm knee score, WOMET score, and Tegner score. CLINICAL RELEVANCE: The MKQ facilitates the comparison of treatment results in knee disorders and allows the evaluation of treatment efficacy. Identified inadequate treatment concepts could be eliminated, leading to increased patient satisfaction and optimized quality of health care.


Assuntos
Traumatismos do Joelho/diagnóstico , Osteoartrite do Joelho/diagnóstico , Avaliação de Resultados da Assistência ao Paciente , Adolescente , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Traumatismos do Joelho/fisiopatologia , Articulação do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/fisiopatologia , Satisfação do Paciente , Estudos Prospectivos , Reprodutibilidade dos Testes , Inquéritos e Questionários , Resultado do Tratamento , Adulto Jovem
15.
Int Orthop ; 39(5): 865-70, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25294307

RESUMO

PURPOSE: Anterior cruciate ligament (ACL) injury represents one of the most common diagnoses in orthopaedic sports medicine. In the past, anatomic knowledge about the different bundles within the cruciate ligaments triggered new treatment concepts, such as double-bundle ACL reconstruction. Recently, besides complete tearing, partial ACL ruptures and bundle augmentation became a focus. However, only little is known regarding rotational stability of the knee with an isolated torn postero-lateral (PL) bundle. Therefore, the aim of the present study was the torsiometric analysis of tibio-femoral restraint patterns of the PL-insufficient knee joint. METHODS: Fresh human whole body cadavers were enrolled. After diagnostic arthroscopy to ensure the structural integrity of the cruciate ligaments, knee joints underwent torsiometry at 0°, 30°, and 90° degree flexion. Then stepwise the PL bundle and the anteromedial (AM) bundle were arthroscopically resected, while torsiometry of the PL- as well as of the ACL-deficient knee joints was repeated. An area under the curve (AUC) was calculated. All statistical analyses were conducted using a p-value of 0.05 as level of significance. RESULTS: The comparison of charged and equilibrated curves during internal rotation revealed significant results at low flexion (30° flexion) angles between the ACL intact versus PL absent conditions (p = 0.04). In addition, charged and equilibrated curves during external rotation at 90° flexion, thus high angles, resulted in a significant difference when comparing the ACL-intact with the PL-deficient condition (p = 0.01). CONCLUSIONS: In the present cadaver study using the Torsiometer tool we found a distinct destabilization of the rotational restraints in full knee extension only after total ACL resection. In contrast, no significant findings resulted after an isolated dissection of the PL bundle during internal deflection. Nevertheless, a significant loss of stability was found during unstressed external deflection after isolated PL bundle dissection. Therefore patients, undergoing PL augmentation might benefit regarding rotational instability patterns.


Assuntos
Lesões do Ligamento Cruzado Anterior , Traumatismos do Joelho/cirurgia , Articulação do Joelho/fisiopatologia , Adulto , Reconstrução do Ligamento Cruzado Anterior , Cadáver , Feminino , Fêmur/fisiologia , Humanos , Instabilidade Articular/cirurgia , Traumatismos do Joelho/fisiopatologia , Masculino , Pessoa de Meia-Idade , Amplitude de Movimento Articular , Rotação , Ruptura , Tíbia/fisiologia , Torção Mecânica
16.
BMC Musculoskelet Disord ; 15: 380, 2014 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-25406639

RESUMO

BACKGROUND: Treatment of lateral fractures of the clavicle is challenging and has been controversially discussed for a long time due to high non-union rates in non-operative treatment and high complication rates in surgical treatment. Acromioclavicular joint instability due to the injury of the closely neighbored coraco-clavicular ligaments can result in a cranialization of the medial clavicle shaft. A recently developed implant showed a promising functional outcome in a small collective of patients. METHODS: In this prospective study, 20 patients with a mean age of 40.7 ± 11.3 years with a dislocated fracture of the lateral clavicle (Jäger&Breitner I-III, Neer I-III) were enrolled. All patients were surgically treated using the locking compression plate (LCP) for the superior anterior clavicle (Synthes®). Functional outcome was recorded using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self-assessment of the Shoulder Pain and Disability Index (SPADI), of the Disability of the Arm, Shoulder and Hand (DASH) score and of the Constant Score. Acromioclavicular joint stability was evaluated using the Taft-Score. RESULTS: The mean follow-up was 14.2 ± 4.0 months. The mean MSQ was 87.0 ± 7.4 points, the mean SPADI 91.1 ± 11.3 points, the mean DASH score 7.6 ± 7.3 points and the mean normative age- and sex-specific Constant Score 85.6 ± 8.0 points. The mean Taft Score resulted in 10.7 ± 1.0 points. The mean Taft Score in lateral clavicular fractures with fracture gap between the coracoclavicular ligaments in combination with a rupture of the conoid ligament (J&B II a, Neer II B; n =11) was with 10.3 ± 0.9 points significantly lower than the mean Taft Score of all other types of lateral clavicle fractures (J&B I, II b, III; n =9) which resulted in 11.3 ± 0.9 points (p<0.05). CONCLUSIONS: The Synthes® LCP superior anterior clavicle plate allows for a safe stabilization and good functional outcome with high patient satisfaction in fractures of the lateral clavicle. However, in fractures type Jäger&Breitner II a, Neer II B a significant acromioclavicular joint instability was observed and additional reconstruction of the coracoclavicular ligaments should be performed. TRIAL REGISTRATION: ClinicalTrials.gov NCT02256059. Registered 02 October 2014.


Assuntos
Placas Ósseas/estatística & dados numéricos , Clavícula/diagnóstico por imagem , Clavícula/lesões , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/terapia , Adulto , Força Compressiva , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Resultado do Tratamento , Adulto Jovem
17.
J Emerg Med ; 46(1): e13-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24011627

RESUMO

BACKGROUND: Acute aortic dissection during pregnancy is an uncommon but important emergency due to its lethal risk to both mother and child. The dissection usually involves the ascending aorta or the aortic arch. Although additional affection of the descending aorta up to bifurcation is possible, further increasing the risk of organ malperfusion, full-length aortic dissection (DeBakey I) is known to be very rare. Dissection during pregnancy has been reported predominantly in combination with Marfan syndrome. Acute aortic dissection Stanford type A (AADA) DeBakey I during pregnancy without signs of Marfan syndrome as a warning signal is very uncommon in the current literature. OBJECTIVES: The etiology, diagnosis, differential diagnosis, and management of this rare disease are discussed in relation to the current literature. CASE REPORT: We report the case of an athletic 34-year-old woman in the third trimester of pregnancy, without history of previous diseases, who presented to our Emergency Department after collapsing. In the resuscitation department, an emergency cesarean section was performed due to the start of circulation failure in the mother. Computed tomography scan revealed a severe aortic dissection starting from 1 cm distal the aortic valve over the full length up to the iliac arteries, involving the brachiocephalic and carotid arteries up to the level of the larynx. Emergency replacement of the ascending aorta and the aortic arch was performed. Both the mother and baby survived and were doing well 1 year postoperatively. CONCLUSION: This alarming result of AADA (DeBakey I) in late pregnancy without obvious warnings such as Marfan syndrome illustrates the importance of performing early imaging in similar cases.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Cesárea , Complicações Cardiovasculares na Gravidez/cirurgia , Adulto , Dissecção Aórtica/diagnóstico por imagem , Aneurisma Aórtico/diagnóstico por imagem , Emergências , Feminino , Humanos , Síndrome de Marfan , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico por imagem , Terceiro Trimestre da Gravidez , Radiografia
18.
Int Orthop ; 37(3): 457-62, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23322064

RESUMO

BACKGROUND: Patients suffering from isolated subacromial impingement (SI) of their shoulder but who are resistant to other therapies benefit substantially from arthroscopic subacromial decompression (ASD) if they are young (<60 years). Although physical demands rise notably in the older population, it still remains unclear if surgery leads to better results in these patients. Therefore, the aim of this study was to focus on the impact of age on the functional outcome in elderly patients suffering from SI. METHODS: In this retrospective analysis, 307 patients (age range: 42-63 years) with isolated SI were enrolled. The 165 patients were allocated to physical therapy whereas 142 underwent ASD. The patient cohort was divided into two groups according to the median age (<57 years). Functional outcome was recorded using the Munich Shoulder Questionnaire (MSQ) allowing for qualitative self -assessment of the Constant, SPADI and Dark Scores. RESULTS: Median age was 57 (25%-75%: 48-63) years, follow-up was 55 (25%-75%: 25-87) months. In group I (age < 57 years, n = 165) no significant differences in outcome between physical therapy and ASD were detected. In contrast, in group II (age > 57 years; n = 142) the patients reported significantly better results after ASD in the overall MSQs. CONCLUSION: Despite their higher age, elderly patients with isolated SI actually benefit significantly from ASD in comparison to physical therapy.


Assuntos
Descompressão Cirúrgica/métodos , Síndrome de Colisão do Ombro/cirurgia , Adulto , Fatores Etários , Artroscopia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recuperação de Função Fisiológica , Estudos Retrospectivos , Resultado do Tratamento
19.
Int Orthop ; 36(7): 1341-7, 2012 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-22262250

RESUMO

PURPOSE: Short-stem hip arthroplasty preserves femoral bone stock which includes the femoral neck. This implies that the stem has to follow the anatomy of the femoral neck. Therefore, it has been questioned whether biomechanical reconstruction of the hip can be safely achieved with SHA. METHODS: Biomechanical reconstruction of the hip was analysed for 50 modular short-stem hip arthroplasties (SHA) and compared to 50 conventional total hip arthroplasties (THA). Biomechanical parameters were analysed on pre- and postoperative pelvic overviews and compared to those of the contralateral side. RESULTS: The position of the acetabular cup (vertical and horizontal hip centre of rotation) changed slightly and was comparable for both groups. Horizontal femoral offset increased more in SHA (6.2 mm) than in THA (2.0 mm). Compared to the contralateral side it was significantly greater after SHA (+3.6 mm) but almost balanced after THA (-0.2 mm). Limb length increased with both procedures (8.0 mm SHA, 9.1 mm THA), but showed a significantly greater discrepancy after SHA (3.3 mm) as compared to THA (1.3 mm). According to the different implant designs, the stem-shaft axis showed a wider varus-valgus range for SHA (6.2° varus to 8.8° valgus) than for THA (2.6° varus to 3.3° valgus). CONCLUSION: Horizontal femoral offset increased more with modular SHA than with conventional THA, but was within a beneficial range. Restoration of limb length appears more difficult in SHA and has a tendency to prolong limb length, which is probably related to the higher femoral resection level. This should be taken into consideration when considering SHA for a patient as well as during implantation.


Assuntos
Artroplastia de Quadril/instrumentação , Articulação do Quadril/cirurgia , Prótese de Quadril , Desenho de Prótese , Acetábulo/patologia , Acetábulo/cirurgia , Adulto , Idoso , Artrite Reumatoide/cirurgia , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fenômenos Biomecânicos , Mau Alinhamento Ósseo , Análise de Falha de Equipamento , Feminino , Fêmur/patologia , Fêmur/cirurgia , Necrose da Cabeça do Fêmur/cirurgia , Luxação Congênita de Quadril/cirurgia , Articulação do Quadril/fisiopatologia , Humanos , Desigualdade de Membros Inferiores/etiologia , Desigualdade de Membros Inferiores/prevenção & controle , Masculino , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Falha de Prótese/etiologia , Estudos Retrospectivos , Adulto Jovem
20.
J Clin Med ; 10(20)2021 Oct 13.
Artigo em Inglês | MEDLINE | ID: mdl-34682807

RESUMO

PURPOSE: Operative therapy for unstable lateral clavicle fractures is necessary to reduce the risk of bony non-union. Irritation and restriction during sportive activities due to the implanted materials are a common reason for impaired function and implant removal. The aim of this study was to gain information on functional outcome and time until return to sport (RTS) after surgical treatment of unstable lateral clavicle fractures, comparing two coracoclavicular button techniques. METHODS: A retrospective chart review of patients who were consecutively treated for unstable lateral clavicle fractures at our level one trauma center from 2014 to 2018 was conducted. Two different surgical techniques were evaluated and compared. Group 1 was treated using a locking compression plate and knotted DogBone™ Button, while group 2 received an LCP and knotless DogBone™ Button. Functional outcome (ASES (American Shoulder and Elbow Score), Constant-Score, DASH (Disability of Arm, Shoulder and Hand), MSQ (Munich Shoulder Questionnaire) and SPADI (Shoulder Pain and Disability Index) and time until RTS were investigated and compared between both groups, 1 year postoperatively. RESULTS: A total of 56 patients (n = 35 group 1, n = 21 group 2) with a mean age of 45.1 ± 14.6 years met the inclusion criteria. Functional outcome reached good to excellent results (ASES 94.7 ± 9.8, Constant Score 85.1 ± 8.1, DASH 5.5 ± 8.4, MSQ 90.9 ± 7.2, SPADI 96.1 ± 5.7). Implant removal rates were higher in group 1 (48.3% vs. 35.3%) yet without statistical significance (p = 0.122). All patients returned to sports postoperatively with a mean time period until return to sport of 4.6 (3-9) months. CONCLUSION: Locking compression plating and coracoclavicular fixation using a knotless Dogbone™ technique provides good to excellent functional outcomes, a high and fast rate of return to sport and lower irritation rates compared to the knotted DogBone™ technique.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA