Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Oral Health ; 22(1): 376, 2022 09 05.
Artigo em Inglês | MEDLINE | ID: mdl-36064526

RESUMO

BACKGROUND: Attachments' configuration play an important role during Clear Aligner Treatment (CAT) for aligner retention and control of movements planned. The aims were to compare the macroscopic morphology of attachments reproduced with flowable (FNC) and conventional (CNC) composites and the effects on them of two light-guide tips with different dimensions. METHODS: 4 resin casts derived from the initial scan of the same patient were obtained. 10 vestibular attachments were replaced on both upper and lower arches of each model with CNC (Models A, B) and FNC (Models C, D). Each composite was cured by means of the same LED lamp with both regular light-guide (Models A, B) and push and light tool® (Models C, D). The 80 attachments were qualitative analyzed by means of a digital stereo microscope. Surface roughness and waviness measurements were assessed by contact probe surface profiler (TalySurf CLI 2000; Taylor Hobson, Leicester, United Kingdom). Statistical analysis was performed with independent samples t-tests. Significance was established at the P < 0.05 level. RESULTS: Model A showed lower values of surface roughness (Ra - 1.41 µm, Rt - 3.46 µm) and waviness (Wa - 2.36 µm, Wt - 10.95 µm) when compared with Model C. Significant reduction of waviness (Wa - 3.85 µm, Wt - 4.90 µm) was observed on Model B when compared with Model D. Significant increase of roughness and waviness parameters (Ra 3.88 µm, Rt 21.07, Wa 2.89 µm, Wt 14.74 µm) was found when CNC sample (Model A) was cured with regular light-guide tip. Higher values (Ra 2.33 µm, Rt 24.07 µm, Wa 1.67 µm, Wt 20.79 µm) were observed after regular light-guide tips curing on FNC sample (Model C). CONCLUSIONS: CNC resins determine more regular surfaces of attachments profiles. The additional use of a smaller light- guide of the LED push and light tool® allows to improve the macroscopic morphology of the attachments and to maximize light irradiance delivering by enhancing the polymerization process and the integrity of the features during the treatment.


Assuntos
Nanocompostos , Aparelhos Ortodônticos Removíveis , Resinas Compostas/uso terapêutico , Lâmpadas de Polimerização Dentária , Cura Luminosa de Adesivos Dentários , Teste de Materiais , Reprodução , Propriedades de Superfície
2.
Angle Orthod ; 94(3): 336-345, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38417457

RESUMO

OBJECTIVES: To evaluate wear and friction properties of oscillating strips in order to validate the importance of a standardized interproximal enamel reduction (IPR) sequence to preserve their efficiency and lifetime. MATERIALS AND METHODS: Fifteen complete oscillating IPR sequences were tested by means of tribological tests (Linear Reciprocating Tribometer, C.S.M. Instruments, Peseaux, Switzerland). Fifteen single 0.2-mm metallic strips underwent a long continuous cycle of 240 minutes. Strip surface roughness and waviness measurements were assessed by means of a contact probe surface profiler (TalySurf CLI 2000; Taylor Hobson, Leicester, UK) and TayMap software. Statistical analysis was performed with independent-samples t-test. Significance was at the P < .05 level. Scanning electronic microscopy analysis of strip surfaces was conducted with an FEI Quanta 200 (Hillsboro, Ore) in high vacuum at 30.00 kV. RESULTS: Resin strips revealed a significant reduction in surface roughness (Ra, Rt, RDq) and a significant increase in waviness parameters (Wa, Wt). Rt and RDq values significantly decreased upon use of the metallic strips. Significantly higher values of Wa (+ 2.84 µm) and Wt (+0.1 µm) were observed only for the 0.2-mm metallic strips. Higher friction values were observed when the metallic strips were tested singularly rather than within the entire sequence. Lower Ra and Rt values were revealed when 0.2-mm metallic strips were tested up to 240 minutes. CONCLUSIONS: The application of a standardized oscillating sequence allows for more efficient wear performance of the strips with a significant impact on their abrasive power and lifetime.


Assuntos
Esmalte Dentário , Eletrônica , Fricção , Propriedades de Superfície , Microscopia Eletrônica de Varredura , Teste de Materiais
3.
Prog Orthod ; 24(1): 9, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36907908

RESUMO

BACKGROUND: To evaluate by means of profilometric analysis and scanning electronic microscope (SEM) the effects on enamel surfaces of oscillating mechanical systems for interproximal enamel reduction (IPR). Fifteen complete (Group 1) oscillating IPR sequence and 15 single metallic strips (Group 2) for active IPR phase of 0.2 mm were selected and tested on 30 freshly extracted teeth by means of tribological tests with alternative dry-sliding motion (Linear Reciprocating Tribometer, C.S.M. Instruments, Peseaux, Switzerland). Enamel surface roughness and waviness measurements were assessed by contact probe surface profiler (TalySurf CLI 2000; Taylor Hobson, Leicester, UK) and a TayMap software for the 3D analysis. Statistical analysis was performed with independent samples t-test. Significance was established at the P < .05 level. SEM analysis of enamel surfaces was conducted with a FEI Quanta 200 (Hillsboro, USA) in high vacuum at 30.00 kV. Images were acquired at 30X, 100X, and 300X of magnification. RESULTS: Teeth undergone Group 1 showed lower values of surface roughness (Ra - 0.34 µm, Rt - 1.55 µm) and significant increase of waviness parameters (Wa 0.25 µm, Wt 4.02 µm) when compared with those treated with Group 2. SEM evaluation showed smoothers and more regular surfaces when IPR was performed by complete IPR sequence. Single metallic strip determined more irregular surfaces characterized by extended grooves, alternated with enamel ridges and irregular fragments. CONCLUSION: The adoption of a standardized oscillating IPR sequence determines more regular and harmonious enamel surfaces at the end of the procedure. An adequate polishing after IPR plays a crucial role to guarantee a good long-term prognosis and a good respect of biological structures.


Assuntos
Esmalte Dentário , Dente , Humanos , Microscopia Eletrônica de Varredura , Propriedades de Superfície , Extração Dentária
4.
Antibiotics (Basel) ; 12(5)2023 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-37237827

RESUMO

The development of biocompatible nanomaterials that interface with human skin and tissue is critical for advancing prosthetics and other therapeutic medical needs. In this perspective, the development of nanoparticles with cytotoxicity and antibiofilm properties and biocompatibility characteristics are important. Metallic silver (Ag) exhibits good biocompatibility, but it is often challenging to integrate it into a nanocomposite without compromising its antibiofilm properties for optimal applications. In this study, new polymer nanocomposites (PNCs) with ultra-low filling content (0.0023-0.046 wt%) of Ag nanoplates were manufactured and tested. The cytotoxicity and antibiofilm activity of different composites with polypropylene (PP) matrix were examined. At first, PNCs surface were analyzed by means of AFM (atomic force microscopy) with phase contrast evaluation and FTIR (Fourier-transform infrared spectroscopy) to study the Ag nanoplates distribution. Subsequently, the cytotoxicity and growth properties of biofilms were assessed by MTT assay protocol and detection of nitric oxide radicals. Antibacterial and antibiofilm activities were measured against Gram-positive bacteria (Staphylococcus aureus) and Gram-negative bacteria (K. pneumoniae). The PNCs with silver exhibited antibiofilm activity although they did not inhibit regular planktonic bacterial growth. Moreover, the PNCs were not cytotoxic to mammalian cells and did not induce significant immune response. These features reveal the potential of the PNCs developed in this study for usage in fabrication of prosthetics and other smart structures for biomedical applications.

5.
Polymers (Basel) ; 14(14)2022 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-35890721

RESUMO

Three multifunctional smart composites for next-generation applications have been studied differently through versatile nanoindentation investigation techniques. They are used in order to determine peculiarities and specific properties for the different composites and to study the charge/matrix, charge/surface, or smart functions interactions. At first, a mapping indentation test was used to check the distribution of hardness and modulus across a large region to examine any non-uniformity due to structural anomalies or changes in properties for a carbon nanotubes (CNTs)-reinforced polypropylene (PP V-2) nanocomposite. This smart composite is suitable to be used in axial impeller fans and the results can be used to improve the process of the composite produced by injection moulding. Secondly, the interfacial properties of the carbon fibre (CF) and the resin were evaluated by a push-out method utilizing the smaller indentation tip to target the individual CF and apply load to measure its displacement under loads. This is useful to evaluate the effectiveness of the surface modification on the CFs, such as sizing. Finally, nanoindentation at different temperatures was used for the probing of the in situ response of smart shape memory polymer composite (SMPC) usable in grabbing devices for aerospace applications. Furthermore, the triggering temperature of the shape memory polymer response can be determined by observing the change of indentations after the heating and cooling cycles.

6.
Materials (Basel) ; 15(3)2022 Feb 05.
Artigo em Inglês | MEDLINE | ID: mdl-35161152

RESUMO

A non-destructive evaluation (NDE) technique capable of testing the dispersion of nanoparticles in a nanocomposite would be of great use to the industry to check the quality of the products made and to ensure compliance with their specifications. Very few NDE techniques found in the literature can evaluate the level of dispersion of the nanoparticles in the whole nanocomposite. Here, a recently developed NDE technique based on pulsed phase thermography (PPT) in transmission mode was used to assess the particle dispersion in ultra-low, less than 0.05 wt%, Ag enriched polymeric based nanocomposite manufactured with an innovative nano-coating fragmentation technique. The phasegrams obtained with the presented technique clearly showed clusters or bundles of Ag nanoparticles when present, down to the size of 6 µm. Therefore, the new NDE approach can be applied to verify that the expected levels of dispersion are met in the production process.

7.
Polymers (Basel) ; 13(18)2021 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-34577957

RESUMO

In this study, Polyurea/Formaldehyde (PUF) microcapsules containing Dicyclopentadiene (DCPD) as a healing substance were fabricated in situ and mixed at relatively low concentrations (<2 wt%) with a thermosetting polyurethane (PU) foam used in turn as the core of a sandwich structure. The shape memory (SM) effect depended on the combination of the behavior of the PU foam core and the shape memory polymer composite (SMPC) laminate skins. SMPC laminates were manufactured by moulding commercial carbon fiber-reinforced (CFR) prepregs with a SM polymer interlayer. At first, PU foam samples, with and without microcapsules, were mechanically tested. After, PU foam was inserted into the SMPC sandwich structure. Damage tests were carried out by compression and bending to deform and break the PU foam cells, and then assess the structure self-healing (SH) and recovery capabilities. Both SM and SH responses were rapid and thermally activated (120 °C). The CFR-SMPC skins and the PU foam core enable the sandwich to exhibit excellent SM properties with a shape recovery ratio up to 99% (initial configuration recovery). Moreover, the integration of microcapsules (0.5 wt%) enables SH functionality with a structural restoration up to 98%. This simple process makes this sandwich structure ideal for different industrial applications.

8.
J Thorac Dis ; 12(5): 2304-2316, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-32642135

RESUMO

BACKGROUND: We sought to investigate and compare biomechanical properties and histomorphometric findings of thoracic ascending aorta aneurysm (TAA) tissue from patients with bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) in order to clarify mechanisms underlying differences in the clinical course. METHODS: Circumferential sections of TAA tissue in patients with BAV (BAV-TAA) and TAV (TAV-TAA) were obtained during surgery and used for biomechanical tests and histomorphometrical analysis. RESULTS: In BAV-TAA, we observed biomechanical higher peak stress and lower Young modulus values compared with TAV-TAA wall. The right lateral longitudinal region seemed to be the most fragile zone of the TAA wall. Mechanical stress-induced rupture of BAV-TAA tissue was sudden and uniform in all aortic wall layers, whereas a gradual and progressive aortic wall breakage was described in TAV-TAA. Histomorphometric analysis revealed higher amount of collagen but not elastin in BAV-TAA tunica media. CONCLUSIONS: The higher deformability of BAV-TAA tissue supports the hypothesis that increased wall shear stress doesn't explain the increased risk of sudden onset of rupture and dissection; other mechanisms, likely related to alteration of specific genetic pathways and epigenetic signals, could be investigated to explain differences in aortic dissection and rupture in BAV patients.

9.
Polymers (Basel) ; 10(2)2018 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30966151

RESUMO

Shape memory properties of PET (polyethylene-terephthalate) foams have been evaluated for two different foam densities. Samples were subjected to multiple memory-recovery cycles along three different directions to measure the effect of foam anisotropy on static mechanical and shape memory properties. The memory cycle was performed by uniaxial compression tests at room temperature. Despite these severe conditions, PET foams demonstrated very good shape memory behavior with shape recovery always higher than 90%. Due to cycling, the mechanical performance of foam samples is partially reduced, mainly along the extrusion direction of the foam panels. Despite this loss of static performance, shape memory properties are only partially affected by thermo-mechanical cycles. The maximum reduction is 10% for shape fixity and 3% for shape recovery. The experimental results are particularly interesting considering that compression tests were undertaken at room temperature. Indeed, PET foams seem to be optimal candidates for self-repairing structures.

10.
Ann Ist Super Sanita ; 51(3): 229-35, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26428048

RESUMO

AIM: The aim of this work is the qualification of commercially available collagen membranes in a comparative manner. The natural origin of collagen makes standardization difficult. Nevertheless, through dimensional and mechanical measures it is possible to mechanically qualify collagen membranes, and compare them. METHODS: Three commercially available collagen membranes used in Guided Bone Regeneration (GBR) and in Guided Tissue Regeneration (GTR) techniques, namely Bio-Gide, Collprotect and Jason, were chosen for the comparison. Quasi-static (tensile tests) and time-dependent (stress relaxation test) mechanical tests together with a functional test (tear test) were done to determine the responses of collagen membranes under different loading conditions. RESULTS: The tested membranes exhibited different behaviours, different deformability values and thickness, Jason being the thinnest and Bio-Gide the thickest. Similar differences were also observed in terms of surface density. DISCUSSION: Even though clinical observations were not within the aim of this study, our findings indicate that a better understanding of the correlation between mechanical properties and thickness could lead to a more rational design and use of these membranes in the face of specific clinical cases.


Assuntos
Colágeno/química , Materiais Dentários , Odontologia/métodos , Materiais Biocompatíveis , Regeneração Óssea , Humanos , Fenômenos Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA