1.
Prenat Diagn ; 41(2): 210-217, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33128403

RESUMO

OBJECTIVES: To assess the performance of the Danish first trimester screening program in twin pregnancies. METHOD: Retrospective, nation-wide, cohort study with data collected from the Danish Fetal Medicine Database (DFMD) and The Danish Central Cytogenetic Registry (DCCR). The cohort included all women with twin pregnancies participating in the national first trimester screening program for Trisomy 21. Risk assessment was based on maternal age, nuchal translucency (NT) thickness and, if available, biochemical markers (ß-hCG and PAPP-A). RESULTS: 8812 twin pregnancies including 42 pregnancies with Trisomy 21 had a risk assessment between 2009 and 2017. The detection rate (DR) for pregnancies with a risk assessment based on maternal age and NT only (missing data on biochemical markers, n = 4693) was 69.6% (95% CI: 50.8%-88.4%) for a 6.3% false positive rate (FPR) (95% CI: 5.6%-7.0%), whereas for pregnancies with a risk assessment based on all three parameters (n = 4119) the DR was 89.5% (95% CI: 76.7%-100.0%) for a 7.2% FPR (95% CI: 6.4%-8.0%). CONCLUSION: The DR of Trisomy 21 in twin pregnancies, seems as high as for singleton pregnancies, when using optimal screening techniques, but the FPR is nearly twice as high.


Assuntos
Gonadotropina Coriônica Humana Subunidade beta/sangue , Síndrome de Down/diagnóstico , Gravidez de Gêmeos , Proteína Plasmática A Associada à Gravidez/metabolismo , Adulto , Amniocentese , Amostra da Vilosidade Coriônica , Síndrome de Down/sangue , Reações Falso-Positivas , Feminino , Humanos , Idade Materna , Medição da Translucência Nucal , Gravidez , Primeiro Trimestre da Gravidez , Técnicas de Reprodução Assistida
2.
Phys Med Biol ; 52(16): 4893-904, 2007 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-17671342

RESUMO

The purpose of this study is to investigate whether the method of applicator reconstruction and/or the applicator orientation influence the dose calculation to points around the applicator for brachytherapy of cervical cancer with CT-based treatment planning. A phantom, containing a fixed ring applicator set and six lead pellets representing dose points, was used. The phantom was CT scanned with the ring applicator at four different angles related to the image plane. In each scan the applicator was reconstructed by three methods: (1) direct reconstruction in each image (DR), (2) reconstruction in multiplanar reconstructed images (MPR) and (3) library plans, using pre-defined applicator geometry (LIB). The doses to the lead pellets were calculated. The relative standard deviation (SD) for all reconstruction methods was less than 3.7% in the dose points. The relative SD for the LIB method was significantly lower (p < 0.05) than for the DR and MPR methods for all but two points. All applicator orientations had similar dose calculation reproducibility. Using library plans for applicator reconstruction gives the most reproducible dose calculation. However, with restrictive guidelines for applicator reconstruction the uncertainties for all methods are low compared to other factors influencing the accuracy of brachytherapy.


Assuntos
Braquiterapia/métodos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Braquiterapia/instrumentação , Imagens de Fantasmas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Phys Med Biol ; 48(12): 1753-71, 2003 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-12870581

RESUMO

The electron paramagnetic resonance (EPR) alanine dosimetry system is based on EPR measurements of radicals formed in alanine by ionizing radiation. The system has been studied to determine its energy dependence for photons in the 10-30 MV region relative to those of 60Co and to find out if the system would be suitable for dosimetry comparisons. The irradiations were carried out at the National Research Council, Ottawa, Canada and the doses ranged from 8 to 54 Gy. The EPR measurements were performed at the University of Oslo, Norway. The ratio of the slope of the alanine reading versus dose-to-water curve for a certain linac photon beam quality and the corresponding slope for a reference 60Co gamma-radiation gives an experimental measure of the relative dose-to-water response of the EPR alanine dosimetry system. For calculating the linear regression coefficients of these alanine reading versus dose curves, the method of weighted least squares was used. This method is assumed to produce more accurate regression coefficients when applied to EPR dosimetry than the common method of standard least squares. The overall uncertainty on the ratio of slopes was between 0.5 and 0.6% for all three linac energies. The relative response for all the linac beams compared to cobalt was less than unity: by about 0.5% for the 20 and 30 MV points but by more than 1% for the 10 MV point. The given standard uncertainties negate concluding that there is any significant internal variation in the measured response as a function of beam quality between the three linac energies. Thus, we calculated the average dose response for all three energies and found that the alanine response is 0.8% (+/-0.5%) lower for high energy x-rays than for 60Co gamma-rays. This result indicates a small energy dependence in the alanine response for the high-energy photons relative to 60Co which may be significant. This result is specific to our dosimetry system (alanine with 20% polyethylene binder pressed into a particular shape) including its waterproofing sleeve of PMMA (2 mm thick); however, we expect that this result may apply to other similar detectors.


Assuntos
Alanina/efeitos da radiação , Espectroscopia de Ressonância de Spin Eletrônica/métodos , Fótons , Radiometria/métodos , Alanina/química , Biometria , Fenômenos Biofísicos , Biofísica , Radioisótopos de Cobalto , Espectroscopia de Ressonância de Spin Eletrônica/estatística & dados numéricos , Análise dos Mínimos Quadrados , Modelos Teóricos , Aceleradores de Partículas , Polimetil Metacrilato , Radiometria/estatística & dados numéricos , Temperatura , Água