RESUMO
INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.
Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Estudos Retrospectivos , CatéteresRESUMO
INTRODUCTION: Catheter stability during atrial fibrillation ablation is associated with higher ablation success rates. Rapid cardiac pacing and high-frequency jet ventilation (HFJV) independently improve catheter stability. Simultaneous modulation of cardiac and respiratory motion has not been previously studied. The objective of this study was to determine the effect of simultaneous heart rate and respiratory rate modulation on catheter stability. METHODS: Forty patients undergoing paroxysmal atrial fibrillation ablation received ablation lesions at 15 prespecified locations (12 left atria, 3 right atria). Patients were randomly assigned to undergo rapid atrial pacing for either the first or the second half of each lesion. Within each group, half of the patients received HFJV and the other half standard ventilation. Contact force and ablation data for all lesions were compared among the study groups. Standard deviation of contact force was the primary endpoint defined to examine contact force variability. RESULTS: Lesions with no pacing and standard ventilation had the greatest contact force standard deviation (5.86 ± 3.08 g), compared to lesions with pacing and standard ventilation (5.45 ± 3.28 g; P < .01) or to lesions with no pacing and HFJV (4.92 ± 3.00 g; P < .01). Lesions with both pacing and HFJV had the greatest reduction in contact force standard deviation (4.35 ± 2.81 g; P < .01), confirming an additive benefit of each maneuver. Pacing and HFJV together was also associated with a reduction in the proportion of lesions with excessive maximum contact force (P < .001). DISCUSSION: Rapid pacing and HFJV additively improve catheter stability. Simultaneous pacing with HFJV further improves catheter stability over pacing or HFJV alone to optimize ablation lesions.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Ventilação em Jatos de Alta Frequência , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Catéteres , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , HumanosRESUMO
OBJECTIVES: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS: We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: There were no differences in baseline demographics, atrial size, or valvular disease between HCM and control patients. Patients with HCM had significantly reduced atrial conduction velocity compared to controls (0.44 ± 0.17 vs 0.56 ± 0.10 m/s, p = 0.01), despite no significant differences in bipolar voltage amplitude (1.23 ± 0.38 vs 1.20 ± 0.41 mV, p = 0.76). There was a statistically significant reduction in conduction velocity in the posterior left atrium in HCM patients relative to controls (0.43 ± 0.18 vs 0.58 ± 0.10 m/s, p = 0.003), but not in the anterior left atrium (0.46 ± 0.17 vs 0.55 ± 0.10 m/s, p = 0.05). There was a significant association between conduction velocity and interventricular septal thickness (slope = -0.013, R2 = 0.13, p = 0.03). CONCLUSIONS: Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.
Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Apêndice Atrial/cirurgia , Ablação por Cateter/efeitos adversosRESUMO
BACKGROUND: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE: The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS: Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS: Both abnormal bipolar voltage and omnipolar voltage encompassed all critical sites and were observed over a median of 66 cm2 (interquartile range [IQR] 41.3-86 cm2) and 52 cm2 (IQR 37.7-65.5 cm2), respectively. ILAM deceleration zones were observed over a median of 9 cm2 (IQR 5.0-11.1 cm2) and encompassed 22 critical sites (67%), while abnormal omnipolar conduction velocity (CV <1 mm/ms) was observed over 10 cm2 (IQR 5.3-16.6 cm2) and identified 22 critical sites (67%), and fractionation mapping was observed over a median of 4 cm2 (IQR 1.5-7.6 cm2) and encompassed 20 critical sites (61%). The mapping yield was the highest for fractionation + CV (2.1 critical sites/cm2) and least for bipolar voltage mapping (0.5 critical sites/cm2). CV identified 100% of critical sites in areas with a local point density of >50 points/cm2. CONCLUSION: ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.
Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ablação por Cateter/métodosRESUMO
BACKGROUND: The Medtronic Sprint Fidelis (Medtronic Inc., Minneapolis, MN, USA) lead family is associated with an unacceptable incidence of premature lead failure. There are limited data on risk factors for lead fracture. We hypothesized that factors leading to potential increased forces on the lead related to device implantation or technique may be associated with premature lead failure. METHODS: We reviewed the implant data from our group and identified 176 patients who received active fixation Medtronic Fidelis (Model 6931, single coil and Model 6949, dual coil) leads. Implant data, including age, sex, venous access site, implant side, implant location, and number of venous leads were reviewed. Hospital, pacemaker clinic, and Medtronic registration databases were reviewed for evidence of lead failure, replacement, or abandonment. Data was evaluated in univariate and multivariate regression analyses. RESULTS: Of the 176 leads implanted, 10 (5.7%) were noted to develop malfunction. This presented as inappropriate shocks from sensed noise or elevated impedance measurements. Of the above noted implant features, only right-sided (vs left-sided) implant (hazard ratio [HR] 18.8, 95% confidence intervals [CI] 3.8, 93.3), and subpectoral implant (vs prepectoral; HR 14.31, 95% CI 3.2, 64.0) were predictive of lead failure in maximally adjusted models. CONCLUSIONS: We have identified both right-sided implantation and subpectoral generator positioning as factors associated with premature lead malfunction in Fidelis active fixation leads. Clinical decisions regarding patient management should incorporate these findings in regard to lead replacement in high-risk patients.
Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Eletrodos Implantados/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Ventrículos do Coração/cirurgia , Idoso , Feminino , Humanos , Masculino , Fatores de Risco , Estados Unidos/epidemiologiaRESUMO
AIMS: High recurrence rates after complex radiofrequency ablation procedures, such as for atrial fibrillation, remain a major clinical problem. Local electrophysiological changes that occur following cardiac ablation therapy are incompletely described in the literature. The purpose of this study was to determine whether alterations in conduction velocity, action potential duration (APD), and effective refractory period resolve dynamically following cardiac ablation. METHODS AND RESULTS: Lesions were delivered to the right ventricle of mice using a subxiphoid approach. The sham-operated control group (SHAM) received the same procedure without energy delivery. Hearts were isolated at 0, 1, 7, 30, and 60 days following the procedure and electrophysiological parameters were obtained using high-resolution optical mapping with a voltage-sensitive dye. Conduction velocity was significantly decreased at the lesion border in the 0, 7, and 30 day groups compared to SHAM. APD(70) at the lesion border was significantly increased at all time points compared to SHAM. Effective refractory period was significantly increased at the lesion border at 0, 1, 7, and 30 days but not at 60 days post-ablation. This study demonstrated that post-ablation electrophysiological changes take place immediately following energy delivery and resolve within 60 days. CONCLUSIONS: Cardiac ablation causes significant electrophysiological changes both within the lesion and beyond the border zone. Late recovery of electrical conduction in individual lesions is consistent with clinical data demonstrating that arrhythmia recurrence is associated with failure to maintain bi-directional conduction block.
Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/cirurgia , Ablação por Cateter , Fenômenos Eletrofisiológicos/fisiologia , Potenciais de Ação/fisiologia , Animais , Arritmias Cardíacas/epidemiologia , Feminino , Sistema de Condução Cardíaco/fisiologia , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Camundongos , Camundongos Endogâmicos C57BL , Modelos Animais , RecidivaRESUMO
BACKGROUND: There are little data on the appropriate endpoint for slow pathway ablation that balances acceptable procedural times, recurrence rates, and complication rates. This study compared recurrence rates of three commonly utilized endpoints of slow pathway ablation for atrioventricular nodal reentrant tachycardia (AVNRT). METHODS: We performed a meta-analysis of AVNRT slow pathway ablation cohorts by searching electronic databases, the Internet, and conference proceedings. Inclusion criteria were age >18 years, >20 human subjects per study, primary AVNRT ablation, English language publication, and >1 month of follow-up. Data were analyzed with a fixed-effects model using Comprehensive Meta-Analysis software version 2.2.046 (Biostat, Englewood, NJ, USA). RESULTS: We included 10 studies encompassing 1,204 patients with a mean age of 41-53 years. Endpoints were complete slow pathway ablation, residual jump only, and single remaining echo beat. Pooled estimates revealed 28 of 641 patients (4.4%) with complete slow pathway ablation, 13 of 192 patients (6.8%) with a residual jump only, and 24 of 371 patients (6.5%) with one echo had recurrences. With uniform isoproterenol use after ablation, there was no significant difference in recurrence rates among the endpoints. However, when isoproterenol was utilized after ablation only if needed to induce AVNRT before ablation, a significantly higher recurrence rate occurred in patients with a residual jump (P = 0.002), a single echo (P = 0.003), or the combined group of a residual jump and/or one echo (P = 0.001). CONCLUSIONS: Isoproterenol should be used routinely after slow pathway modification, when a residual jump and/or single echo remain.
Assuntos
Ablação por Cateter/estatística & dados numéricos , Determinação de Ponto Final/métodos , Sistema de Condução Cardíaco/cirurgia , Avaliação de Resultados em Cuidados de Saúde/métodos , Taquicardia por Reentrada no Nó Atrioventricular/epidemiologia , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Medição de Risco , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Resultado do TratamentoRESUMO
BACKGROUND: PRKAG2 mutations cause glycogen-storage cardiomyopathy, ventricular preexcitation, and conduction system degeneration. A genetic approach that utilizes a binary inducible transgenic system was used to investigate the disease mechanism and to assess preventability and reversibility of disease features in a mouse model of glycogen-storage cardiomyopathy. METHODS AND RESULTS: Transgenic (Tg) mice expressing a human N488I PRKAG2 cDNA under control of the tetracycline-repressible alpha-myosin heavy chain promoter underwent echocardiography, ECG, and in vivo electrophysiology studies. Transgene suppression by tetracycline administration caused a reduction in cardiac glycogen content and was initiated either prenatally (Tg(OFF(E-8 weeks))) or at different time points during life (Tg(OFF(4-16 weeks)), Tg(OFF(8-20 weeks)), and Tg(OFF(>20 weeks))). One group never received tetracycline, expressing transgene throughout life (Tg(ON)). Tg(ON) mice developed cardiac hypertrophy followed by dilatation, ventricular preexcitation involving multiple accessory pathways, and conduction system disease, including sinus and atrioventricular node dysfunction. CONCLUSIONS: Using an externally modifiable transgenic system, cardiomyopathy, cardiac dysfunction, and electrophysiological disorders were demonstrated to be reversible processes in PRKAG2 disease. Transgene suppression during early postnatal development prevented the development of accessory electrical pathways but not cardiomyopathy or conduction system degeneration. Taken together, these data provide insight into mechanisms of cardiac PRKAG2 disease and suggest that glycogen-storage cardiomyopathy can be modulated by lowering glycogen content in the heart.
Assuntos
Doença de Depósito de Glicogênio Tipo IIb/genética , Doença de Depósito de Glicogênio Tipo IIb/terapia , Complexos Multienzimáticos/genética , Complexos Multienzimáticos/farmacologia , Proteínas Serina-Treonina Quinases/genética , Proteínas Serina-Treonina Quinases/farmacologia , Proteínas Quinases Ativadas por AMP , Fatores Etários , Animais , Eletrocardiografia , Eletrofisiologia , Terapia Genética , Glicogênio/análise , Humanos , Camundongos , Camundongos Transgênicos , Regiões Promotoras Genéticas/efeitos dos fármacos , Tetraciclina/administração & dosagem , Tetraciclina/farmacologiaRESUMO
OBJECTIVES: This study sought to determine whether a radiation safety time-out reduces radiation exposure in electrophysiology procedures. BACKGROUND: Time-outs are integral to improving quality and safety. The authors hypothesized that a radiation safety time-out would reduce radiation exposure levels for patients and the health care team members. METHODS: The study was performed at the New York University Langone Health Electrophysiology Lab. Baseline data were collected for 6 months prior to the time-out. On implementation of the time-out, data were collected prospectively with analyses to be performed every 3 months. The primary endpoint was dose area product. The secondary endpoints included reference point dose, fluoroscopy time, use of additional shielding, and use of alternative imaging such as intracardiac and intravascular ultrasound. RESULTS: A total of 1,040 patient cases were included. The median dose area product prior to time-out was 18.7 Gyâcm2, and the median during the time-out was 14.7 Gyâcm2, representing a 21% reduction (p = 0.007). The median reference point dose prior to time-out was 163 mGy, and during the time-out was 122 mGy (p = 0.011). The use of sterile disposable protective shields and ultrasound imaging for access increased significantly during the time-out. CONCLUSIONS: A radiation safety time-out significantly reduces radiation exposure in electrophysiology procedures. Electrophysiology laboratories, as well as other areas of cardiovascular medicine using fluoroscopy, should strongly consider the use of radiation safety time-outs to reduce radiation exposure and improve safety.
Assuntos
Técnicas Eletrofisiológicas Cardíacas , Segurança do Paciente , Doses de Radiação , Exposição à Radiação , Idoso , Idoso de 80 Anos ou mais , Técnicas Eletrofisiológicas Cardíacas/métodos , Técnicas Eletrofisiológicas Cardíacas/normas , Feminino , Fluoroscopia/normas , Humanos , Masculino , Estudos Prospectivos , Exposição à Radiação/prevenção & controle , Exposição à Radiação/normas , Exposição à Radiação/estatística & dados numéricos , Fatores de TempoRESUMO
OBJECTIVES: This study sought to investigate the effect of pacing mediated heart rate modulation on catheter-tissue contact and impedance reduction during radiofrequency ablation in human atria during atrial fibrillation (AF) ablation. BACKGROUND: In AF ablation, improved catheter-tissue contact enhances lesion quality and acute pulmonary vein isolation rates. Previous studies demonstrate that catheter-tissue contact varies with ventricular contraction. The authors investigated the impact of modulating heart rate on the consistency of catheter-tissue contact and its effect on lesion quality. METHODS: Twenty patients undergoing paroxysmal AF ablation received ablation lesions at 15 pre-specified locations (12 left atria, 3 right atria). Patients were assigned randomly to undergo rapid atrial pacing for either the first half or the second half of each lesion. Contact force and ablation data with and without pacing were compared for each of the 300 ablation lesions. RESULTS: Compared with lesion delivery without pacing, pacing resulted in reduced contact force variability, as measured by contact force SD, range, maximum, minimum, and time within the pre-specified goal contact force range (p < 0.05). There was no difference in the mean contact force or force-time integral. Reduced contact force variability was associated with a 30% greater decrease in tissue impedance during ablation (p < 0.001). CONCLUSIONS: Pacing induced heart rate acceleration reduces catheter-tissue contact variability, increases the probability of achieving pre-specified catheter-tissue contact endpoints, and enhances impedance reduction during ablation. Modulating heart rate to improve catheter-tissue contact offers a new approach to optimize lesion quality in AF ablation. (The Physiological Effects of Pacing on Catheter Ablation Procedures to Treat Atrial Fibrillation [PEP AF]; NCT02766712).
Assuntos
Fibrilação Atrial/cirurgia , Estimulação Cardíaca Artificial/métodos , Ablação por Cateter/métodos , Átrios do Coração/cirurgia , Frequência Cardíaca/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
Pacemaker cells in the heart generate periodic electrical signals that are conducted to the working myocardium via the specialized conduction system. Effective cell-to-cell communication is critical for rapid, uniform conduction of cardiac action potentials-- a prerequisite for effective, synchronized cardiac contraction. Local circuit currents form the basis of the depolarization wave front in the working myocardium. These currents flow from cell to cell via gap junction channels. In this chapter, we trace the path of the action potential from its generation in the sinus node to propagation through the working myocardium, with a detailed discussion of the role of gap junctions. First, we review the transmembrane ionic currents and the basic principles of conduction of the action potential to the working myocardium via the specialized tissues of the heart. Next, we consider the relative contribution of cell geometry, size, and gap junction conductance. These factors are examined in terms of their source-to-sink relationships. Lastly, we will discuss new insights into the importance of gap junctions in cardiac conduction in health and disease which have been gained from high resolution optical mapping in connexin-deficient mice.
Assuntos
Potenciais de Ação/fisiologia , Junções Comunicantes/fisiologia , Sistema de Condução Cardíaco/fisiologia , Miócitos Cardíacos/fisiologia , Animais , Conexinas/fisiologia , Humanos , Remodelação Ventricular/fisiologiaRESUMO
SCN5A encodes the α subunit of the major cardiac sodium channel Na(V)1.5. Mutations in SCN5A are associated with conduction disease and ventricular fibrillation (VF); however, the mechanisms that link loss of sodium channel function to arrhythmic instability remain unresolved. Here, we generated a large-animal model of a human cardiac sodium channelopathy in pigs, which have cardiac structure and function similar to humans, to better define the arrhythmic substrate. We introduced a nonsense mutation originally identified in a child with Brugada syndrome into the orthologous position (E558X) in the pig SCN5A gene. SCN5A(E558X/+) pigs exhibited conduction abnormalities in the absence of cardiac structural defects. Sudden cardiac death was not observed in young pigs; however, Langendorff-perfused SCN5A(E558X/+) hearts had an increased propensity for pacing-induced or spontaneous VF initiated by short-coupled ventricular premature beats. Optical mapping during VF showed that activity often began as an organized focal source or broad wavefront on the right ventricular (RV) free wall. Together, the results from this study demonstrate that the SCN5A(E558X/+) pig model accurately phenocopies many aspects of human cardiac sodium channelopathy, including conduction slowing and increased susceptibility to ventricular arrhythmias.
Assuntos
Arritmias Cardíacas/genética , Síndrome de Brugada/genética , Sistema de Condução Cardíaco/anormalidades , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Animais , Arritmias Cardíacas/fisiopatologia , Sequência de Bases , Síndrome de Brugada/fisiopatologia , Doença do Sistema de Condução Cardíaco , Códon sem Sentido , Modelos Animais de Doenças , Engenharia Genética , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Contração Miocárdica , Miocárdio/metabolismo , Miocárdio/patologia , Sus scrofaRESUMO
BACKGROUND: Spinal cord stimulation (SCS) has been shown to modulate atrial electrophysiology and confer protection against ischemia and ventricular arrhythmias in animal models. OBJECTIVE: To determine whether SCS reduces the susceptibility to atrial fibrillation (AF) induced by tachypacing (TP). METHODS: In 21 canines, upper thoracic SCS systems and custom cardiac pacing systems were implanted. Right atrial and left atrial effective refractory periods were measured at baseline and after 15 minutes of SCS. Following recovery in a subset of canines, pacemakers were turned on to induce AF by alternately delivering TP and searching for AF. Canines were randomized to no SCS therapy (CTL) or intermittent SCS therapy on the initiation of TP (EARLY) or after 8 weeks of TP (LATE). AF burden (percent AF relative to total sense time) and AF inducibility (percentage of TP periods resulting in AF) were monitored weekly. After 15 weeks, echocardiography and histology were performed. RESULTS: Effective refractory periods increased by 21 ± 14 ms (P = .001) in the left atrium and 29 ± 12 ms (P = .002) in the right atrium after acute SCS. AF burden was reduced for 11 weeks in EARLY compared with CTL (P <.05) animals. AF inducibility remained lower by week 15 in EARLY compared with CTL animals (32% ± 10% vs 91% ± 6%; P <.05). AF burden and inducibility were not significantly different between LATE and CTL animals. There were no structural differences among any groups. CONCLUSIONS: SCS prolonged atrial effective refractory periods and reduced AF burden and inducibility in a canine AF model induced by TP. These data suggest that SCS may represent a treatment option for AF.
Assuntos
Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação da Medula Espinal/métodos , Análise de Variância , Animais , Fibrilação Atrial/etiologia , Fibrilação Atrial/patologia , Modelos Animais de Doenças , Cães , Eletrocardiografia , Átrios do Coração/inervação , Medição de Risco , Medula Espinal/fisiologia , Fatores de TempoAssuntos
Arritmias Cardíacas/diagnóstico por imagem , Dispositivos de Terapia de Ressincronização Cardíaca , Tomografia Computadorizada Multidetectores/normas , Segurança do Paciente/normas , Vigilância de Produtos Comercializados/métodos , United States Food and Drug Administration , Feminino , Humanos , MasculinoRESUMO
Sarcomere protein gene mutations cause hypertrophic cardiomyopathy (HCM), a disease with distinctive histopathology and increased susceptibility to cardiac arrhythmias and risk for sudden death. Myocyte disarray (disorganized cell-cell contact) and cardiac fibrosis, the prototypic but protean features of HCM histopathology, are presumed triggers for ventricular arrhythmias that precipitate sudden death events. To assess relationships between arrhythmias and HCM pathology without confounding human variables, such as genetic heterogeneity of disease-causing mutations, background genotypes, and lifestyles, we studied cardiac electrophysiology, hypertrophy, and histopathology in mice engineered to carry an HCM mutation. Both genetically outbred and inbred HCM mice had variable susceptibility to arrhythmias, differences in ventricular hypertrophy, and variable amounts and distribution of histopathology. Among inbred HCM mice, neither the extent nor location of myocyte disarray or cardiac fibrosis correlated with ex vivo signal conduction properties or in vivo electrophysiologically stimulated arrhythmias. In contrast, the amount of ventricular hypertrophy was significantly associated with increased arrhythmia susceptibility. These data demonstrate that distinct somatic events contribute to variable HCM pathology and that cardiac hypertrophy, more than fibrosis or disarray, correlates with arrhythmic risk. We suggest that a shared pathway triggered by sarcomere gene mutations links cardiac hypertrophy and arrhythmias in HCM.