Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Pediatr Cardiol ; 44(4): 951-954, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36912925

RESUMO

Coronary artery-to-pulmonary artery fistulae are a not uncommon finding in patients with Tetralogy of Fallot (TOF) and collateral-dependent pulmonary blood flow. Management for these fistulae is often primary surgical ligation or unifocalization at the time of complete repair, dependent on the presence of dual blood flow to the involved areas. We present the case of a 32-week premature boy weighing 1.79 kg with TOF, confluent branch pulmonary arteries, major aortopulmonary collaterals, and right coronary artery to main pulmonary artery fistula. The patient demonstrated evidence of coronary steal into the pulmonary vasculature with an elevation in the troponin level without hemodynamic instability, and subsequently underwent successful transcatheter occlusion of the fistula via right common carotid access using a Medtronic 3Q microvascular plug. This case demonstrates the realistic potential for early coronary steal in this physiology and possibility of transcatheter therapy even in a small neonate.


Assuntos
Fístula , Tetralogia de Fallot , Masculino , Recém-Nascido , Humanos , Lactente , Tetralogia de Fallot/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Circulação Colateral , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia
2.
Pediatr Cardiol ; 42(4): 918-925, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33590324

RESUMO

Pericardiocentesis is traditionally performed using a subxiphoid approach. Hepatomegaly or loculated and noncircumferential effusions warrant nonstandard approaches to drain effusions; echocardiographic guidance has made these less traditional, non-subxiphoid approaches feasible. The study is aimed at comparing clinical outcomes of the subxiphoid and non-subxiphoid approaches to percutaneous pericardiocentesis in a pediatric population. This is a retrospective chart review of all children undergoing percutaneous pericardiocentesis from August 2008 to December 2019 at a single-center. A total of 104 patients underwent echocardiography-guided pericardiocentesis during the timeframe. Additionally, fluoroscopy was also used in 80 patients. Hematopoietic stem cell transplantation was the most common underlying diagnosis (n = 53, 50.9%). A non-subxiphoid approach was used in 58.6% (n = 61) of patients. The fifth and sixth intercostal spaces were the most commonly used (n = 17 each). The non-subxiphoid group tended to be older (95.9 vs. 21.7 months, p = 0.006) and weighed more (23.6 vs. 11.2 kgs, p = 0.013) as compared to the subxiphoid group. Non-subxiphoid approach was associated with shorter procedure times (21 vs. 37 min, p = 0.005). No major complications were seen. Five minor complications occurred and were equally distributed in the two groups. Complications were more likely in younger patients (p = 0.047). The technique and anatomic approach to pericardiocentesis, and the location or size of effusion did not influence the risk of complications. Echocardiography-guided percutaneous pericardiocentesis in children was associated with low complication rates in this single-center pediatric experience. The use of a non-traditional, non-subxiphoid approach was associated with shorter procedure times and did not significantly affect complication rates.


Assuntos
Derrame Pericárdico/cirurgia , Pericardiocentese/métodos , Criança , Pré-Escolar , Drenagem/métodos , Ecocardiografia/métodos , Feminino , Fluoroscopia/métodos , Transplante de Células-Tronco Hematopoéticas , Humanos , Lactente , Masculino , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Resultado do Tratamento
3.
Echocardiography ; 36(5): 944-947, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-31006919

RESUMO

OBJECTIVES: To report the usefulness of harmonic imaging in echocardiography to visualize and direct the implantation of the Medtronic micro vascular plug (MVP). BACKGROUND: Off label use of the MVP was reported for transcatheter occlusion of patent ductus arteriosus (PDA) in premature infants. The device is poorly visible on fluoroscopy and echocardiography. METHODS: In 9 consecutive premature infants, the MVP was used for transcatheter closure of the PDA. In each, the ability of conventional echocardiographic imaging was compared to harmonic imaging, and the device was deployed in the PDA using echocardiography. RESULTS: In each subject, harmonic imaging proved superior to conventional echocardiography to visualize the MVP in premature infants using 12 and 8 MHz probes. Once the delivery, catheter was across the PDA into the descending aorta, and the MVP advanced to the catheter tip, positioning, and deployment of the device was possible without fluoroscopy. All devices were deployed appropriately with immediate occlusion and no obstruction to the left pulmonary artery or aorta. CONCLUSIONS: The MVP can be accurately imaged using harmonic imaging, even in the near field in premature infants. Precise implantation of the MVP in the PDA of premature infants is possible with echocardiographic imaging of the device and vascular structures.


Assuntos
Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/cirurgia , Ecocardiografia/métodos , Doenças do Prematuro/diagnóstico por imagem , Doenças do Prematuro/cirurgia , Dispositivo para Oclusão Septal , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Desenho de Prótese , Estudos Retrospectivos , Resultado do Tratamento
4.
Echocardiography ; 34(9): 1347-1352, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28833533

RESUMO

BACKGROUND: Ultrasound imaging of adults with heart failure and increased central venous pressure (CVP) has shown significant thoracic duct (TD) dilation from impedance in lymphatic drainage. Elevated CVP and abnormal lymphatic drainage are implicated in severe Fontan complications, including protein losing enteropathy (PLE) and plastic bronchitis (PB). Systematic studies of TD and lymphatic circulation in children are limited, and their cervical TD normative values have not been established. METHODS: Thoracic duct imaging was attempted prospectively during routine echocardiograms performed 7/2014-9/2016 in children 5-21 years old with normal cardiovascular physiology and Fontan palliation. TD insertion to the central venous system (lympho-venous junction) was assessed with an S12-4 MHz transducer. For the first 34 patients, only TD ostia were measured, but ostium shape variability at the lympho-venous junction led to including the TD arch 5-10 mm proximal to the ostium for the remaining cohort. RESULTS: Seventy-nine total subjects were studied: 58 controls, 13 Fontan patients with normal systemic ventricular ejection fraction (EF) (>50%), and 8 Fontan patients with decreased EF (≤50%). Combined Fontan subjects had larger TD ostial diameters compared to controls when normalized by body surface area (median 2.6 mm/m2 vs. 2 mm/m2 ) (P=.04). CONCLUSION: To our knowledge, this is the first systematic study of ultrasonographic TD imaging in children. Fontan patients have larger TD diameters, reflecting the impaired lymphatic circulation in patients with this physiology. Further research may provide important associations between sonographic TD features with the functional status of patients with Fontan circulation.


Assuntos
Pressão Venosa Central/fisiologia , Técnica de Fontan/efeitos adversos , Cardiopatias Congênitas/cirurgia , Complicações Pós-Operatórias/diagnóstico por imagem , Ducto Torácico/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Masculino , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Ducto Torácico/fisiopatologia , Fatores de Tempo , Adulto Jovem
5.
Anesth Analg ; 122(4): 1062-9, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26702866

RESUMO

BACKGROUND: Rapid infusers are vital tools during massive hemorrhage and resuscitation. Sporadic reports of overheating and shutdown of the Belmont® Rapid Infuser, a commonly used system, have been attributed to 1-sided clot blockage of the fluid path. We investigated multiple causes of failure of this device. METHODS: Packed red blood cells and thawed fresh frozen plasma with normal saline solution were used as base fluids for serial 10-minute trials using standard disposable sets in 2 Belmont devices. Possible contributors to device failure, including calcium-containing solutions and external leakage currents, were evaluated. Thermographic images of the heater and disposable cartridges were recorded. The effects of complete unilateral clotting were modeled by sealing half of the disposable cartridge with epoxy. RESULTS: Clotting on the surface of the heat exchanger coil increased with calcium concentration and was only observed at calcium concentrations >12.0 mmol/L (P < 0.0001) in a 1:1 plasma:red blood cell mixture, resulting in high-pressure downstream occlusion alarms and interruption of flow. CONCLUSIONS: Clot-based occlusion can be induced in the Belmont Rapid Infuser under unrealistic conditions. In the absence of complete unilateral flow blockage, we did not observe any significant overheating of the infuser under extreme operating conditions.


Assuntos
Falha de Equipamento , Eritrócitos , Bombas de Infusão/normas , Plasma , Hidratação/métodos , Hidratação/normas , Humanos , Projetos Piloto
6.
Anesthesiology ; 131(3): 751-752, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31094745
7.
Echocardiography ; 31(9): E282-6, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25051996

RESUMO

Conditions that increase central venous pressure lead to secondary dilation of the thoracic duct and impaired lymphatic circulation. We report the use of ultrasound to directly image the cervical part of the thoracic duct in children without the need for invasive techniques or contrast agents. Systematic evaluation of the thoracic duct may be useful in cardiovascular conditions with congestion of the lymphatic system such as single ventricle following Glenn or Fontan procedures.


Assuntos
Cardiopatias/diagnóstico por imagem , Ducto Torácico/diagnóstico por imagem , Adolescente , Adulto , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos , Ultrassonografia , Adulto Jovem
8.
Anesthesiology ; 129(1): 218, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29509583
9.
J Robot Surg ; 17(5): 2149-2155, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37256454

RESUMO

There is emerging but limited data assessing single-port (SP) robot-assisted surgery as an alternative to multi-port (MP) platforms. We compared perioperative outcomes between SP and MP robot-assisted approaches for excision of high and low complexity renal masses. Retrospective chart review was performed for patients undergoing robot-assisted partial or radical nephrectomy using the SP surgical system (n = 23) at our institution between November 2019 and November 2021. Renal masses were categorized as high complexity (7+) or low complexity (4-6) using the R.E.N.A.L. nephrometry scoring system. Adjusting for baseline characteristics, patients were matched using a prospectively maintained MP database in a 2:1 (MP:SP) ratio. For high complexity tumors (n = 12), SP surgery was associated with a significantly longer operative time compared to MP (248.4 vs 188.1 min, p = 0.02) but a significantly shorter length of stay (1.9 vs 2.8 days, p = 0.02). For low complexity tumors (n = 11), operative time (177.7 vs 161.4 min, p = 0.53), estimated blood loss (69.6.0 vs 142.0 mL, p = 0.62), and length of stay (1.6 vs 1.8 days, p = 0.528) were comparable between SP and MP approaches. Increasing nephrometry score was associated with a greater relative increase in operative time for SP compared to MP renal surgery (p = 0.07) using best of fit linear modeling. SP robot-assisted partial and radical nephrectomy is safe and feasible for low complexity renal masses. For high complexity renal masses, the SP system is associated with a significantly longer operative time compared to the MP technique. Careful consideration should be given when selecting patients for SP robot-assisted kidney surgery.


Assuntos
Neoplasias Renais , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Retrospectivos , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Rim/cirurgia , Rim/patologia , Nefrectomia/métodos , Resultado do Tratamento
10.
Anesthesiology ; 114(1): 194-204, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21178675

RESUMO

BACKGROUND: Burnout can lead to health and psychologic problems and is apparently increasing in physicians and nurses. Previous studies have not evaluated all healthcare workers within a single work unit. This study evaluates the risk of burnout in all medical personnel in one perioperative unit. METHODS: We developed an online survey that included demographics, a modified version of the Maslach Burnout Inventory-Human Services Survey, and the Social Support and Personal Coping Survey. Survey constructs (e.g., depersonalization and health) and a global score were calculated. Larger construct and global values were associated with higher risk of burnout. These were separately regressed on role, age, and sex. The global score was then regressed on each of the survey constructs. RESULTS: Of the 145 responses, 46.2% were physicians (22.8% residents), 43.4% were nurses or nurse anesthetists, and 10.3% were other personnel. After adjusting for sex and age, residents scored higher than other physicians on the following (expected change [95% confidence interval]): global score (1.12 [0.43-1.82]), emotional exhaustion (1.54 [0.44-2.60]), and depersonalization (1.09 [0.23-1.95]). Compared with nonphysicians, residents were 1 U or more higher on these items (P < 0.05 in all cases). Residents had higher health (1.49 [0.48-2.50]) and workload (1.23 [0.07-2.40]) values compared with physicians. Better health, personal support, and work satisfaction scores were related to decreased global scores (P < 0.05). CONCLUSIONS: Physicians (particularly residents) had the largest global burnout scores, implying increased risk of burnout. Improving overall health, increasing personal support, and improving work satisfaction may decrease burnout among perioperative team members.


Assuntos
Esgotamento Profissional/epidemiologia , Pessoal de Saúde/psicologia , Assistência Perioperatória/psicologia , Adaptação Psicológica , Distribuição por Idade , Feminino , Pessoal de Saúde/estatística & dados numéricos , Nível de Saúde , Humanos , Internato e Residência , Satisfação no Emprego , Masculino , Pessoa de Meia-Idade , Enfermeiros Anestesistas/psicologia , Enfermeiros Anestesistas/estatística & dados numéricos , Enfermeiras e Enfermeiros/psicologia , Enfermeiras e Enfermeiros/estatística & dados numéricos , Assistência Perioperatória/estatística & dados numéricos , Médicos/psicologia , Médicos/estatística & dados numéricos , Escalas de Graduação Psiquiátrica/estatística & dados numéricos , Fatores de Risco , Distribuição por Sexo , Apoio Social , Inquéritos e Questionários , Carga de Trabalho/psicologia , Carga de Trabalho/estatística & dados numéricos
11.
Anesth Analg ; 113(5): 1064-7, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21865500

RESUMO

Waste anesthetic gas scavenging technology has not changed appreciably in the past 30 years. Open reservoir systems entrain high volumes of room air and dilute waste gases before emission into the atmosphere. This process requires a large vacuum pump, which is both costly to install and, although efficient, operates continuously and at near-full capacity. In an era of increasing energy costs and environmental awareness, carbon footprint reduction is a priority and a more efficient system of safely scavenging waste anesthetic gases is desirable. We tested a low-flow scavenger interface to evaluate the potential for cost and energy savings. The use of this interface in a suite of 4 operating rooms reduced scavenging flow from a constant 37 L/min to a value equal to the fresh gas flow (usually 2 L/min) for each anesthesia machine. Using the ventilator increased this flow by approximately 6 L/min because of the exhaust of ventilator drive gas into the scavenging circuit. Daytime workload of the central vacuum pump decreased from 92% to 12% (expressed as duty cycle). The new system produces energy savings and may increase vacuum pump lifespan.


Assuntos
Anestésicos Inalatórios/isolamento & purificação , Depuradores de Gases , Salas Cirúrgicas , Poluição do Ar em Ambientes Fechados/prevenção & controle , Pressão do Ar , Conservação de Recursos Energéticos , Monitoramento Ambiental , Desenho de Equipamento , Exposição Ocupacional , Vácuo
12.
Anesth Analg ; 110(5): 1480-5, 2010 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-20418309

RESUMO

BACKGROUND: In this study, we performed the infraclavicular block with combined ultrasound guidance and neurostimulation to selectively target cords to compare the success rates of placing a single injection of local anesthetic either in a central or peripheral location. METHODS: Two hundred eighteen patients were enrolled in a consecutive, prospective study. Patients were randomized to injection of local anesthetic either centrally (posterior cord) or peripherally (medial or lateral cord) using ultrasound guidance and neurostimulation. Supervised senior anesthesiology residents or attending anesthesiologists performed the blocks. Both intent-to-treat and treatment-received analyses were used to compare central and peripheral placement efficacy. RESULTS: The overall success rate was significantly higher for the central placements than peripheral placements (96% vs 85%, P = 0.004). Individual cord success rates were as follows: posterior 99%, lateral 92%, and medial 84% (P = 0.001). The central group required attending physician intervention more frequently (27% vs 6%, P < 0.001). Postoperative pain scores of < or =3 were more likely with central placement (100% vs 94%, P = 0.012). CONCLUSION: Central placement of a single injection of local anesthetic targeted at the posterior cord resulted in a higher success rate for infraclavicular block.


Assuntos
Anestésicos Locais/administração & dosagem , Plexo Braquial/diagnóstico por imagem , Bloqueio Nervoso/métodos , Adulto , Idoso , Plexo Braquial/anatomia & histologia , Estimulação Elétrica , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória , Movimento/fisiologia , Músculo Esquelético/fisiologia , Procedimentos Ortopédicos , Dor Pós-Operatória/epidemiologia , Estudos Prospectivos , Sensação/fisiologia , Decúbito Dorsal , Resultado do Tratamento , Ultrassonografia , Extremidade Superior/cirurgia , Adulto Jovem
13.
Am J Cardiol ; 98(3): 416-8, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16860035

RESUMO

Mucopolysaccharidosis type I is a lethal autosomal recessive storage disease caused by a deficiency of lysosomal alpha-L-iduronidase and the consequent systemic accumulation of glycosaminoglycan. Cardiomyopathy and valvar insufficiency occur as glycosaminoglycan accumulates in the myocardium, expands the spongiosa of cardiac valves, and proliferates within the myointima of the epicardial coronary arteries. Congestive heart failure and death occur within the first decade of life in the most severe cases. Allogeneic hematopoietic stem cell transplantation, used in severe forms of the disease, markedly prolongs survival, alleviates ventricular hypertrophy, and preserves cardiac function, but cardiac valves continue to thicken and valvular insufficiency progresses. Enzyme replacement therapy with human recombinant alpha-L-iduronidase has been proposed as an alternativee therapy for patients with mucopolysaccharidosis type I in whom the risk/benefit ratio of hematopoietic stem cell transplantation seems unfavorable. The investigators report the cardiac findings in a small series of 5 children with mucopolysaccharidosis type I who received enzyme replacement therapy for as long as 7 years. No deaths occurred during treatment. Left ventricular hypertrophy, which was present before therapy, resolved in all cases, and myocardial function remained normal. In contrast, the mitral and aortic valves remained thickened and, in some instances, developed progressive thickening and regurgitation. In conclusion, long-term enzyme replacement therapy has some clear benefits for the myocardium, but the cardiac valves appear unresponsive, and the ultimate effect on the coronary vasculature is unknown.


Assuntos
Cardiopatias/etiologia , Iduronidase/uso terapêutico , Mucopolissacaridose I/complicações , Miocárdio/enzimologia , Proteínas Recombinantes/uso terapêutico , Adolescente , Criança , Pré-Escolar , Método Duplo-Cego , Ecocardiografia , Feminino , Glicosaminoglicanos/urina , Cardiopatias/diagnóstico por imagem , Cardiopatias/prevenção & controle , Humanos , Iduronidase/administração & dosagem , Iduronidase/farmacocinética , Infusões Intravenosas , Masculino , Mucopolissacaridose I/tratamento farmacológico , Resultado do Tratamento , Função Ventricular/fisiologia
14.
Laryngoscope ; 126(4): 949-50, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26526978

RESUMO

Suspension laryngoscopy is one of the most common procedures performed for visualizing and diagnosing diseases of the larynx. A relatively uncommon yet potentially life-threatening complication is that of severe bradycardia or asystole during manipulation of the larynx. This case report highlights the occurrence of this complication during a routine removal of a true vocal fold lesion at a tertiary medical center and discusses the potential pathophysiological mechanisms and proposed management options for this phenomenon.


Assuntos
Bradicardia/etiologia , Laringoscopia/efeitos adversos , Humanos , Laringoscopia/métodos , Masculino , Pessoa de Meia-Idade
15.
Am J Cardiol ; 92(7): 882-6, 2003 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-14516901

RESUMO

The Hurler syndrome, an autosomal recessive storage disease of childhood, leads to death within the first decade of life from progressive deposition of glycosaminoglycans within the myointima of the coronary arteries and airways. Cardiac ultrasound findings of patients with this syndrome >10 years after successful bone marrow transplantation are described.


Assuntos
Transplante de Medula Óssea , Mucopolissacaridose I/terapia , Adolescente , Transplante de Medula Óssea/efeitos adversos , Fenômenos Fisiológicos Cardiovasculares , Criança , Feminino , Seguimentos , Cardiopatias/diagnóstico por imagem , Cardiopatias/etiologia , Humanos , Masculino , Mucopolissacaridose I/complicações , Mucopolissacaridose I/fisiopatologia , Avaliação de Resultados em Cuidados de Saúde , Tempo , Ultrassonografia
16.
Ann Thorac Surg ; 77(2): 688-92; discussion 692-3, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14759460

RESUMO

PURPOSE: The purpose of this study was to evaluate the ability of the Myocor Coapsys device to restore leaflet apposition and valve competency off-pump in a canine model of functional mitral regurgitation (MR). DESCRIPTION: The Coapsys device was surgically implanted in 10 dogs after MR induction by rapid ventricular pacing. The Coapsys consists of anterior and posterior epicardial pads connected by a subvalvular chord. The annular head of the posterior pad was positioned at the annular level to draw the posterior leaflet and annulus toward the anterior leaflet. Final device size was selected when MR was minimized or eliminated as assessed by color flow Doppler echocardiography. EVALUATION: All implants were placed off-pump without atriotomy, and mean MR grade was reduced from 2.9 +/- 0.7 to 0.6 +/- 0.7 (p < 0.001) acutely. No hemodynamic compromise was noted. CONCLUSIONS: The Coapsys device consistently and significantly reduced or eliminated functional MR acutely. Further study will be required to assess the chronic stability of the repair in this animal model.


Assuntos
Estimulação Cardíaca Artificial , Ponte Cardiopulmonar , Modelos Animais de Doenças , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Próteses e Implantes , Animais , Materiais Revestidos Biocompatíveis , Cães , Ecocardiografia Doppler em Cores , Estudos de Viabilidade , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Hemodinâmica , Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/diagnóstico por imagem , Poliésteres , Politetrafluoretileno
17.
Ann Emerg Med ; 44(6): 628-34, 2004 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-15573039

RESUMO

STUDY OBJECTIVE: Patients with communicable diseases may require respiratory isolation to reduce the chance of transmission to health care workers and the public. This project was conducted to determine whether negative-pressure isolation for multiple patients can be achieved quickly and effectively using general hospital space not previously dedicated to respiratory isolation. METHODS: The physical therapy gymnasium was the area designated to test the ability to create a negative-pressure isolation environment in a large space. The conversion was planned in advance of an unscheduled drill to convert the space. Four high-efficiency particulate air (HEPA) filtered forced air machines were used to generate negative pressure. The units were vented to the outside air by a 25-foot length of 10-inch-diameter reusable duct. We evaluated the time needed for equipment setup and room conversion and noted any subjective difficulty with either setup or operation of the equipment. We measured the ability of the equipment to generate a negative air pressure relative to adjacent areas and determined the noise levels created during the use of different combinations of machines at various power settings. RESULTS: After drill activation and the request for equipment setup, 1 hour was required to convert the physical therapy gymnasium into an operational negative-pressure environment. The room pressure readings "high" power ranged from -1.5 to -13 Pa (-0.006 to -0.052 inches of water), and noise levels ranged from 70 to 76 dB. Calculated air changes per hour using 1, 2, 3, or 4 units running simultaneously at "high" power were 4.1, 8.2, 12.3, and 16.4, respectively. Using 4 units at once running at "low" power setting yielded 8.2 air changes per hour and generated a room pressure reading of -8.0 Pa, or -0.032 inches of water. CONCLUSION: Portable HEPA filtered forced air units are an effective means of creating large patient care areas with the negative-pressure environment required for respiratory isolation. This design results in a significantly lower-cost alternative compared with construction of individual rooms or units with similar capability and can be retrofitted to existing space. This type of unit would allow treatment of many more patients than current hospital capability would permit and would be an important asset in meeting the needs created by bioterrorism or a naturally occurring epidemic.


Assuntos
Arquitetura Hospitalar , Controle de Infecções/instrumentação , Ventilação/instrumentação , Estudos de Viabilidade , Controle de Infecções/métodos , Filtros Microporos , Ruído , Serviço Hospitalar de Fisioterapia
18.
J Clin Anesth ; 16(1): 43-7, 2004 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-14984859

RESUMO

The anesthetic management of three pediatric patients who underwent awake craniotomy with a combined, continuous intravenous infusion of propofol and alfentanil is described. The Laryngeal Mask Airway was effective in airway management during resection of epileptic foci with intraoperative cortical mapping and neuropsychological (speech) evaluation.


Assuntos
Encéfalo/cirurgia , Craniotomia , Máscaras Laríngeas , Vigília , Adolescente , Alfentanil , Anestésicos Combinados , Anestésicos Intravenosos , Mapeamento Encefálico , Criança , Epilepsia/cirurgia , Feminino , Humanos , Infusões Intravenosas , Propofol
19.
Nursing ; 4 Suppl to Periodical Publication: 20-23, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-28196009
20.
J Thorac Cardiovasc Surg ; 146(4): 854-860.e3, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23871139

RESUMO

OBJECTIVES: Unbalanced atrioventricular (AV) canal defects include a hypoplastic ventricle (HV) and AV valve (HAVV) precluding complete 2-ventricle repairs (2VRs). Catch-up growth would solve this problem and was induced by increasing HAVV flow. The objectives were to assess reliability of HV and HAVV growth and provide 5- to 15-year 2VR follow-up. METHODS: From 1990 to 2005, 23 consecutive infants (13 females and 10 males) with echo-diagnosed unbalanced AV canal defects (n = 20) or subsets (n = 3) underwent 2VRs. HV volumes (18 left and 5 right) and HAVV sizes estimated from biplane echoes and z values (standard deviation from expected) were determined. Hypoplasia was defined by a z value of less than -2.0. Three operative approaches were used: (1) Staged repairs (n = 9) had complete AVV repairs with partial atrial septal defect and ventricular septal defect closures, which increased HAVV flow and maintained stability. The septal defects were closed later. (2) An asymmetric valve partition (n = 8) was used to increase HAVV size. (3) For moderate hypoplasia, HAVV flow was increased and ASDs/VSDs were left for stability (n = 6). Follow-up at 5 to 19 years was done locally. RESULTS: Staged repairs began at 20 to 328 days (average, 129 days) and were completed 5 to 145 days later (average, 101 days). Midterm survival was 87% (20/23) after 1 central nervous system bleed after trial weaning from extracorporeal membrane oxygenation and 2 later deaths from hyperkalemia. Reoperations for AVV regurgitation (n = 3), AVV stenosis (n = 1), and mitral valve replacement (n = 1) were satisfactory. On follow-up, all hypoplastic structures (HV and HAVV) had grown to normal size. Two patients "doing well" were lost to follow-up. Survivors have satisfactory 2VRs, with 15 of 18 taking no cardiac failure medications. CONCLUSIONS: Reliable HV/HAVV catch-up growth was induced, and all midterm 2VRs were satisfactory.


Assuntos
Anormalidades Múltiplas , Procedimentos Cirúrgicos Cardíacos , Comunicação Atrioventricular/cirurgia , Comunicação Interatrial/cirurgia , Comunicação Interventricular/cirurgia , Ventrículos do Coração/cirurgia , Adolescente , Adulto , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Comunicação Atrioventricular/diagnóstico , Comunicação Atrioventricular/fisiopatologia , Feminino , Defeitos dos Septos Cardíacos , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/fisiopatologia , Comunicação Interventricular/diagnóstico , Comunicação Interventricular/fisiopatologia , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/crescimento & desenvolvimento , Humanos , Lactente , Recém-Nascido , Masculino , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA