Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Ann Nucl Med ; 34(3): 155-162, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31808134

RESUMO

OBJECTIVE: Boron neutron capture therapy (BNCT) is a noninvasive radiation therapy method for cancer treatment. In BNCT, 4-borono-2-[18F]-fluoro-L-phenylalanine (18F-FBPA) PET has been employed to estimate 10B accumulation in target tumors and normal tissues if 10B borono-L-phenylalanine (10B-BPA) is used as a boron carrier. The purpose of the current study was to evaluate the total distribution volume (Vt) of 18F-FBPA in normal organs of healthy volunteers by kinetic analysis and to estimate boron concentration in normal organs for the therapeutic dose of 10B-BPA using obtained Vt values. METHODS: Six healthy volunteers were injected with 18F-FBPA (3-5 MBq/kg), and 7 PET-CT scans were performed subsequently. 18F-FBPA radioactivity in whole blood and plasma was measured before, and eight times after the injection. PET images were analyzed by PMOD software. Twelve volumetric regions of interest including the brain, heart, right lung, spleen, liver, parotid salivary glands, esophagus, stomach, pancreas, intestines, and bone marrow were drawn manually for each subject and analyzed with the Logan plot and two Ichise multilinear analyses (MA1 and MA2). The better model was defined by several goodness-of-fit parameters and residual distribution. After Vt values had been derived, boron concentration was estimated in ppm for the 10B-BPA-fructose (10B-BPA-fr) dose 30 g 1 and 2 h post-injection using Vt and interpolated plasma activity data. RESULTS: The Ichise MA2 model showed the best fit among all models. Akaike Information Criterion (AIC) was the lowest for the Ichise's MA2 in all regions (mean AIC value - 14.0) comparing to the other models (Logan plot mean AIC 31.4; Ichise MA1 model mean AIC - 4.2). Mean Vt values of the Ichise MA2 model ranged from 0.94 ± 0.14 ml/ml in the pancreas to 0.16 ± 0.02 ml/ml in the right lung. Estimated boron concentration for 10B-BPA-fr had the highest value in the pancreas (14.0 ± 1.9 ppm 1 h after, and 5.7 ± 1.7 ppm 2 h after the 18F-FBPA administration) and the lowest value in the right lung (2.4 ± 0.3 ppm 1 h, and 1.0 ± 0.3 ppm 2 h post-injection). CONCLUSION: The 10B concentration in normal tissues was best estimated using Vt values of 18F-FBPA with the Ichise multilinear analysis 2 (MA2). TRAIL REGISTRY: The UMIN clinical trial number: UMIN000022850.


Assuntos
Compostos de Boro/farmacocinética , Terapia por Captura de Nêutron de Boro/métodos , Neoplasias/radioterapia , Fenilalanina/análogos & derivados , Adulto , Compostos de Boro/administração & dosagem , Compostos de Boro/síntese química , Relação Dose-Resposta à Radiação , Feminino , Radioisótopos de Flúor/química , Voluntários Saudáveis , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias/diagnóstico por imagem , Fenilalanina/administração & dosagem , Fenilalanina/síntese química , Fenilalanina/farmacocinética , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
2.
Ann Nucl Med ; 32(10): 702-708, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30194665

RESUMO

OBJECTIVES: A previous study reported that a differential diagnosis between glioblastoma progression and radiation necrosis by 4-borono-2-[18F]-fluoro-phenylalanine ([18F]FBPA) PET can be made based on lesion-to-normal ratio of [18F]FBPA accumulation. Two-dimensional data acquisition mode PET alone system, with in-plane resolution of 7.9 mm and axial resolution of 13.9 mm, was used. In the current study, we aimed to confirm the differential diagnostic capability of [18F]FBPA PET/CT with higher PET spatial resolution by three-dimensional visual inspection and by measuring mean standardized uptake value (SUVmean), maximum SUV (SUVmax), metabolic tumor volume (MTV), and total lesion (TL) [18F]FBPA uptake. METHODS: Twelve patients of glioma (9), malignant meningioma (1), hemangiopericytoma (1), and metastatic brain tumor (1) were enrolled. All had preceding radiotherapy. High-resolution three-dimensional data acquisition mode PET/CT with in-plane resolution of 4.07 mm and axial resolution of 5.41 mm was employed for imaging. Images were three-dimensionally analyzed using the PMOD software. SUVmean and SUVmax of lesion and normal brain were measured. Lesion MTV and TL FBPA uptake were calculated. The diagnostic accuracy of [18F]FBPA PET/CT in detecting recurrence (n = 6) or necrosis (n = 6) was verified by clinical follow-up. RESULTS: All parameters showed significantly higher values for tumor recurrence than for necrosis. SUVmean in recurrence was 2.95 ± 0.84 vs 1.18 ± 0.24 in necrosis (P = 0.014); SUVmax in recurrence was 4.63 ± 1.23 vs 1.93 ± 0.44 in necrosis (P = 0.014); MTV in recurrence was 44.92 ± 28.93 mL vs 10.66 ± 8.46 mL in necrosis (P = 0.032); and mean TL FBPA uptake in recurrence was 121.01 ± 50.48 g vs 12.36 ± 9.70 g in necrosis (P = 0.0029). CONCLUSION: In this preliminary feasibility study, we confirmed the possibility of differentiating tumor recurrence from radiation necrosis in patients with irradiated brain tumors by [18F]FBPA PET/CT using indices of SUVmean, SUVmax, MTV, and TL 18FBPA uptake.


Assuntos
Compostos de Boro , Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/patologia , Fenilalanina/análogos & derivados , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Lesões por Radiação/diagnóstico por imagem , Adulto , Idoso , Encéfalo/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Neoplasias Encefálicas/radioterapia , Diagnóstico Diferencial , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Necrose/diagnóstico por imagem , Necrose/etiologia , Lesões por Radiação/etiologia , Recidiva , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA