Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
JTCVS Tech ; 2: 10-15, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34317734

RESUMO

OBJECTIVE: We describe a novel and safe technique using a 12F-14F pediatric arterial cannula to establish unilateral, selective, antegrade cerebral perfusion (ACP) during open hemiarch reconstruction. METHODS: Between January 2015 and September 2018, 42 patients underwent elective aortic aneurysm repair requiring an open distal anastomosis and at least a hemiarch replacement via hypothermic circulatory arrest by 2 surgeons. All distal reconstructions were performed at moderate hypothermia (22°C-26°C) with direct cannulation of the innominate artery (IA) using a pediatric arterial cannula to allow ACP at 10-15 mL/kg/min. Data were collected by retrospective chart review. RESULTS: Thirty-one of the 42 patients (74%) were male. The mean patient age was 65 ± 13 years, and the mean body surface area was 2.1 ± 0.3 m2. Proximal repairs included a modified Bentall with a valve-graft composite (n = 17), valve-sparing root replacement (n = 2), and aortic valve replacement (n = 15). Perioperative mortality was 2% (n = 1), and the incidence of stroke was 0%. The mean lowest core body temperature reached during circulatory arrest was 23.8 ± 2.7°C with a mean ACP time of 21.8 ± 3.6 minutes. The mean aortic cross-clamp and cardiopulmonary bypass times were 160.6 ± 55.5 minutes and 204.7 ± 57.5 minutes, respectively. There were no cases of IA injury. CONCLUSIONS: Direct IA cannulation with a pediatric arterial cannula is a safe and efficient method to allow ACP in aortic surgery requiring hypothermic circulatory arrest and may circumvent the potential complications of axillary cannulation.

2.
Ann Thorac Surg ; 110(2): 508-515, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31866480

RESUMO

BACKGROUND: The objective of this study was to compare long-term outcomes of Mosaic (Medtronic, Minneapolis, MN) porcine mitral valves to Carpentier-Edwards (Edwards Lifesciences, Irving, CA) bovine pericardial mitral valves. METHODS: From 2001 through 2017 at a single institution, 940 patients received a mitral bioprosthesis, of which 463 (49.3%) were porcine and 477 (50.7%) were bovine pericardial. Retrospective review of the procedure and the postoperative clinical course, including echocardiography, through August 2018 were analyzed. All consecutive mitral valve replacements over the study period were included. Follow-up was 99% (929 patients) complete for a total of 6045 patient-years (mean, 6.4 ± 4.5 years). A propensity-matched cohort of 802 mitral bioprosthesis was used for outcome analyses. RESULTS: Operative mortality of the 940 patients was 5.4% (n = 51) and incidence of postoperative stroke was 2.1% (n = 20). Overall survival of the propensity-matched patients at 10 and 15 years was 49.7% (95% confidence interval [CI] 45.5%-53.7%) and 23.3% (95% CI 17.9%-29.3%), respectively. Survival at 15 years was 24.0% (95% CI 18.0%-30.5%) for porcine and 16.5% (95% CI 5.5%-32.6%) for bovine implants, which was not significantly different (P = .67). Overall cumulative incidence for reoperative structural valve deterioration at 15 years was 7.9% (95% CI 4.7%-12.3%) for porcine valves versus 13.2% (95% CI 8.1%-19.5%) for pericardial valves (P < .001). For patients age younger than 65 years, structural valve deterioration at 15 years was 15.8% (95% CI 7.4%-27.0%) versus 30.2% (95% CI 15.1%-46.8%) for porcine and pericardial valves, respectively (P = .009). Overall average time to reoperation for structural valve deterioration for porcine valves was 11.1 ± 2.3 years vs 6.8 ± 2.3 years for bovine pericardial valves (P < .001). CONCLUSIONS: In long-term follow-up, of patients younger than 65 years of age undergoing mitral valve replacement, bovine pericardial valves experienced earlier and more frequent structural valve deterioration than porcine valves.


Assuntos
Bioprótese , Previsões , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Idoso , Animais , Ecocardiografia , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/mortalidade , Humanos , Masculino , Michigan/epidemiologia , Valva Mitral/diagnóstico por imagem , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Suínos
3.
SAGE Open Med Case Rep ; 6: 2050313X18819933, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30788111

RESUMO

Once a self-expanding transcatheter aortic valve replacement is fully deployed, a snare device must be used to retrieve it. Minimal data are available regarding technique, efficacy, and complications associated with the retrieval of such valves. Here, we present two patients in which an EN Snare® Device (Merit Medical System, South Jordan, UT, USA) was safely and effectively used to retrieve and reposition the latest generation self-expanding transcatheter aortic valve replacement.

4.
Ann Thorac Surg ; 106(1): 58-62, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29501643

RESUMO

BACKGROUND: Minimally invasive aortic valve replacement (mAVR) is gaining clinical acceptance; however, it is associated with increased operative times because of the limited surgical field and access. The Cor-Knot (CK; LSI Solutions, Victor, NY) is an automated fastening device designed to facilitate suture fastening, but clinical data in mAVR are lacking. METHODS: From May 2014 to February 2017, 92 patients underwent mAVR at Spectrum Health in Grand Rapids, Michigan; 39 valves were secured with manually tied sutures, and 53 valves were entirely secured with the CK device. Preoperative characteristics and 30-day outcomes data were extracted from the local The Society of Thoracic Surgeons database and the patients' electronic medical records. Survival data were obtained from the Michigan State Social Security Death Index. RESULTS: No significant differences in preoperative characteristics were noted between the two groups. Aortic cross-clamp time (72 ± 12 minutes vs 82 ± 15 minutes; p = 0.001) was significantly shorter with CK. There was no difference in the rate of postoperative mortality (0% vs 0%), stroke (0% vs 1.9%), atrial fibrillation (28% vs 33%), renal failure (0% vs 3.8%), or pacemaker implantation (5.1% vs 5.7%) between patients with manually tied sutures and patients with sutures fastened with the CK. Valve function on postoperative echocardiography and 1-year patient survival rates were similar. CONCLUSIONS: In mAVR, the CK device was associated with reduced aortic cross-clamp time while providing equivalent clinical outcomes. Larger studies are needed to confirm the efficacy, safety, and cost-effectiveness of the CK device in minimally invasive aortic valve surgery.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Automação/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Técnicas de Sutura/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Michigan , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/mortalidade , Estudos Retrospectivos , Medição de Risco , Volume Sistólico/fisiologia , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS