Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 67
Filtrar
1.
BMC Gastroenterol ; 21(1): 51, 2021 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-33535972

RESUMO

BACKGROUND: To compare oncological results and safety profile of balloon micro-catheter trans-arterial chemoembolization (b-TACE) and drug-eluting-microsphere (DEM-TACE) in patients with hepatocellular-carcinoma (HCC). METHODS: This is a case-control, retrospective, single-center study. Between January-2015/March-2019, 149 patients (131 males [87.9%]) with 226 HCC were treated, 22 patients (35 HCC; 19 [86.4%] males) with b-TACE and 127 with DEM-TACE (191 HCC, 112 [88.2%] males). Embolization protocol was standardized (sequential 100 ± 25 and 200 ± 25 µm microspheres). Results were evaluated by modified-response-evaluation-criteria-in-solid-tumor [mRECIST] at 1, 3-6 and 9-12 months and time to recurrence after complete response [TTR] at 1 years. Cox's regression weighted with tumor dimensions was performed. Adverse events (AEs) were recorded. RESULTS: mRECIST oncological response at all time points (1, 3-6 and 9-12 months) for both treatments were similar, with the exception of Objective response rate at 9-12 months. Objective response at 1 and 3-6 months between b-TACE vs DEM-TACE [23/35 (65.7%) vs 119/191 (62.3%), 21/29 (72.4%) vs 78/136 (57.4%) (p > 0.05), respectively]. On the contrary, at 9-12 months, it was significantly higher in b-TACE subgroup than DEM-TACE (15/19 [78.9%] vs 48/89 [53.9%], p = 0.05). TTR for complete response at 1 year had a better trend for b-TACE vs DEM-TACE (278.0 days [196.0-342.0] vs 219.0 days [161.0-238.0], OR 0.68 [0.4-1.0], p = 0.10). The use of balloon micro-catheter reduced the relative risk of the event of recurrence by 0.63 [CI95% 0.38-1.04]; p = 0.07). No significant differences were found in AEs rate. CONCLUSION: b-TACE showed a trend of better oncological response over DEM-TACE with and longer TTR with a similar adverse events rate, in patients presenting with larger tumors.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Carcinoma Hepatocelular/terapia , Estudos de Casos e Controles , Quimioembolização Terapêutica/efeitos adversos , Humanos , Neoplasias Hepáticas/terapia , Masculino , Recidiva Local de Neoplasia , Estudos Retrospectivos , Resultado do Tratamento
2.
BMC Pulm Med ; 20(1): 325, 2020 Dec 29.
Artigo em Inglês | MEDLINE | ID: mdl-33375928

RESUMO

BACKGROUND: During the ongoing pandemic of coronavirus disease 2019 (COVID-19), lockdown periods have changed the way that people and communities live, work and interact. CASE PRESENTATION: This case report describes an uncommon but important presentation of allergic bronchopulmonary aspergillosis (ABPA) in a previously healthy male, who decided to live in the basement of his house when Italy entered a nationwide lockdown during the COVID-19 pandemic. As high resolution computed tomography (HRCT) of the chest on admission showed diffuse miliary nodules, a miliary tuberculosis was initially suspected. However, further investigations provided a diagnosis of unusual presentation of ABPA. CONCLUSIONS: This case highlights the importance of maintaining awareness of Aspergillus-associated respiratory disorders during the COVID-19 pandemic, especially because lifestyle changes associated with home isolation carry an increased risk of exposure to mold spores present in some indoor environments.


Assuntos
Aspergilose Broncopulmonar Alérgica/diagnóstico , COVID-19/diagnóstico , Tuberculose Miliar/diagnóstico , Aspergilose Broncopulmonar Alérgica/diagnóstico por imagem , COVID-19/prevenção & controle , Controle de Doenças Transmissíveis , Diagnóstico Diferencial , Humanos , Itália , Masculino , Pessoa de Meia-Idade , SARS-CoV-2 , Tomografia Computadorizada por Raios X
3.
J Vasc Interv Radiol ; 30(3): 305-313, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30713031

RESUMO

PURPOSE: To report clinical effectiveness, toxicity profile, and prognostic factors of combined 100 µm ± 25 and 200 µm ± 50 epirubicin-loaded polyethylene glycol (PEG) microsphere drug-eluting embolic transcatheter arterial chemoembolization protocol in patients with hepatocellular carcinoma. MATERIALS AND METHODS: In this prospective, single-center, single-arm study with 18 months of follow-up, 36 consecutive patients (mean age 69.9 y ± 10.8; 26 men, 10 women; 54 naïve lesions) were treated. Embolization was initiated with 100 µm ± 25 microspheres, and if stasis (10 heart beats) was not achieved, 200 µm ± 50 microspheres were administered. Each syringe (2 mL) of PEG microsphere was loaded with 50 mg of epirubicin. Results were evaluated using Modified Response Evaluation Criteria In Solid Tumors with multidetector computed tomography/magnetic resonance imaging at 1, 3-6, 9-12, and 15-18 months. Toxicity profile was assessed by laboratory testing before and after the procedure. Complications were recorded. Postembolization syndrome (PES) was defined as onset of fever/nausea/pain after the procedure. Patient/lesion characteristics and treatment results were correlated with predicted outcome using regression analysis. Child-Pugh score was A in 86.1% of patients (31/36) and B in 13.9% (5/36). RESULTS: In 10 of 21 lesions, < 2 cm in diameter (47.5%) stasis was achieved with 100 µm ± 25 microspheres only, whereas all other lesions required adjunctive treatment with 200 µm ± 50 microspheres. Reported adverse events were grade 1 acute liver bile duct injury (3/39 cases, 7.7%) and PES (grade 2; 3/39 cases, 7.7%). Complete response (CR) at 1, 3-6, 9-12, and 15-18 months was 61.1%, 65.5%, 63.63%, and 62.5%. Objective response (CR + partial response) at 1, 3-6, 9-12, and 15-18 months was 83.3%, 65.85%, 63.63%, and 62.5%. No single factor (laboratory testing, etiology, patient status, hepatic status, tumor characteristics, administration protocol) predicted outcomes except for albumin level at baseline for CR (P < .05, odds ratio = 1.09). CONCLUSIONS: The combined microsphere sizing strategy was technically feasible and yielded promising results in terms of effectiveness and toxicity.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Portadores de Fármacos , Epirubicina/administração & dosagem , Neoplasias Hepáticas/terapia , Polietilenoglicóis/química , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/efeitos adversos , Biópsia , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/mortalidade , Carcinoma Hepatocelular/patologia , Quimioembolização Terapêutica/efeitos adversos , Quimioembolização Terapêutica/mortalidade , Progressão da Doença , Epirubicina/efeitos adversos , Estudos de Viabilidade , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/patologia , Masculino , Microesferas , Pessoa de Meia-Idade , Tamanho da Partícula , Intervalo Livre de Progressão , Estudos Prospectivos , Cidade de Roma , Fatores de Tempo , Tomografia Computadorizada por Raios X , Carga Tumoral
4.
Radiol Med ; 124(12): 1212-1219, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31473930

RESUMO

OBJECTIVE: To evaluate the prognostic value of sequential dual-phase CBCT (DP-CBCT) imaging performed during degradable starch microsphere TACE (DSM-TACE) session in predicting the HCC's response to treatment, evaluate with modify response evaluation criteria in solid tumours (mRECIST) at 1-month multi-detector CT (MDCT) follow-up. MATERIALS AND METHODS: Between January and May 2018, 24 patients (68.5 ± 8.5 year [45-85]) with HCC lesions (n = 96 [average 4/patient]) were prospectively enrolled. Imaging assessment included: pre-procedural MDCT, intra-procedural DP-CBCT performed before first and second DSM-TACEs and 1-month follow-up MDCT. Lesions' attenuation/pseudo-attenuation was defined as average value measured on ROIs (HU for MDCT; arbitrary unit called HU* for CBCT). Lesions' attenuation modification was correlated with the post-procedural mRECIST criteria at 1-month MDCT. RESULTS: Eighty-two DSM-TACEs were performed. Lesion's attenuation values were: pre-procedural MDCT arterial phase (AP) 107.00 HU (CI 95% 100.00-115.49), venous phase (VP) 85.00 HU (CI 95% 81.13-91.74); and lesion's pseudo-attenuation were: first CBCT-AP 305.00 HU* (CI 95% 259.77-354.04), CBCT-VP 155.00 HU* (CI 95% 135.00-163.34). For second CBCT were: -AP 210.00 HU* (CI 95% 179.47-228.58), -VP 141.00 HU* (CI 95% 125.47-158.11); and for post-procedural MDCT were: -AP 95.00 HU (CI 95% 81.35-102.00), -VP 83.00 HU (CI 95% 78.00-88.00). ROC curve analysis showed that a higher difference pseudo-attenuation between first and second DP-CBCTs is related to treatment response. The optimal cut-off value of the difference between first and second CBCT-APs to predict complete response, objective response (complete + partial response) and overall disease control (objective response + stable disease) were > 206 HU* (sensitivity 80.0%, specificity 81.7%), > 72 HU* (sensitivity 79.5%, specificity 83.0%) and > - 7 HU* (sensitivity 91.6%, specificity 65.4%), respectively. CONCLUSIONS: DP-CBCT can predict intra-procedurally, by assessing lesion pseudo-attenuation modification, the DSM-TACE 1-month treatment outcome.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas , Amido/uso terapêutico , Idoso , Idoso de 80 Anos ou mais , Antibióticos Antineoplásicos/administração & dosagem , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Epirubicina/administração & dosagem , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Masculino , Microesferas , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Curva ROC , Radiografia Intervencionista/métodos , Critérios de Avaliação de Resposta em Tumores Sólidos , Sensibilidade e Especificidade , Estatísticas não Paramétricas , Fatores de Tempo , Resultado do Tratamento
5.
Eur Radiol ; 28(11): 4900-4908, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29736849

RESUMO

OBJECTIVES: To evaluate the diagnostic performance of 3TMRI in comparison with ultrasound (US) and 99mTc-sestamibi scan for presurgical localisation of parathyroid adenomas (PTAs) in patients with primary hyperparathyroidism (PHPT). METHODS: Fifty-seven patients affected by PHPT were prospectively enrolled and underwent US, 99mTc-sestamibi and 3TMRI. T2-weighted and post-contrast T1-weighted Iterative decomposition of water and fat with Echo Asymmetry and Least squares estimation (IDEAL) sequences were acquired. Diagnostic performance of US, 99mTc-sestamibi and MRI in localising PTAs to correct quadrant were compared according to surgical and pathological findings. RESULTS: According to surgical findings, US correctly localised 41/46 PTAs (sensitivity of 89.1%; specificity 97.5%; PPV 93.1% and NPV 95.6%); 99mTc-sestamibi correctly localised 38/46 PTAs (sensitivity 83.6%, specificity 98.3%, PPV 95% and NPV 93.7%). US and 99mTc-sestamibi combined had a sensitivity of 93.4% (43/46 PTAs), specificity of 98.3%, PPV 95% and NPV 98.3%. MRI correctly localised 45/46 PTAs (sensitivity 97.8%; specificity 97.5%; PPV 93.7% and NPV 99.2%). MRI was able to detect six adenomas missed by 99mTc-sestamibi and two adenomas missed by US. MRI and US were able to detect all enlarged parathyroid glands in patients with multiglandular disease. MRI identified six of seven ectopic adenomas. CONCLUSIONS: Our study demonstrated high diagnostic performance of 3T MRI in the preoperative PTAs quadrant localisation, as well as in patients with multiglandular disease and ectopic PTAs. MRI may be preferred to adequately select patient candidates for minimally invasive parathyroidectomy (MIP). KEY POINTS: • PTA(s) quadrant localisation by 3TMRI was more accurate than US+99mTc-sestamibi. • MRI identified all enlarged glands in multiglandular disease similarly to US. • MRI identified 6/7 ectopic PTAs similarly to 99mTc-sestamibi. • Presurgical PTA(s) localisation by 3TMRI select the optimal candidates for MIP.


Assuntos
Adenoma/diagnóstico por imagem , Hiperparatireoidismo Primário/etiologia , Imageamento por Ressonância Magnética/métodos , Neoplasias das Paratireoides/diagnóstico por imagem , Adulto , Idoso , Feminino , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Pessoa de Meia-Idade , Neoplasias das Paratireoides/patologia , Cintilografia/métodos , Sensibilidade e Especificidade , Tecnécio Tc 99m Sestamibi , Ultrassonografia , Adulto Jovem
6.
Radiol Med ; 123(5): 345-350, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29307077

RESUMO

OBJECTIVES: To evaluate potential relationship between qualitative CT features, quantitative texture analysis (QTA), histology, WHO staging, Masaoka classification and myasthenic syndrome in patients with thymic tumors. MATERIALS AND METHODS: Sixteen patients affected by histologically proven thymic tumors were retrospectively included in the study population. Clinical information, with special regard to myasthenic syndrome and serological positivity of anti-AchR antibodies, were recorded. Qualitative CT evaluation included the following parameters: (a) location; (b) tumor edges; (c) necrosis; (d) pleural effusion; (e) metastases; (f) chest wall infiltration; (g) tumor margins. QTA included evaluation of "Mean" (M), "Standard Deviation" (SD), "Kurtosis" (K), "Skewness" (S), "Entropy" (E), "Shape from Texture" (TX_sigma) and "average of positive pixels" (MPP). Pearson-Rho test was used to evaluate the relationship of continuous non-dichotomic parameters, whereas Mann-Whitney test was used for dichotomic parameters. RESULTS: Histological evaluation demonstrated thymoma in 12 cases and thymic carcinoma in 4 cases. Tumor necrosis was significantly correlated with QTA Mean (p = 0.0253), MPP (p = 0.0417), S (p = 0.0488) and K (p = 0.0178). WHO staging was correlated with Mean (p = 0.0193), SD (p = 0.0191) and MPP (p = 0.0195). Masaoka classification was correlated with Mean (p = 0.0322), MPP (p = 0.0315), skewness (p = 0.0433) and Kurtosis (p = 0.0083). Myasthenic syndrome was significantly associated with Mean (p = 0.0211) and MPP (p = 0.0261), whereas tumor size was correlated with Mean (p = 0.0241), entropy (p = 0.0177), MPP (p = 0.0468), skewness (p = 0.009) and Kurtosis (p = 0.006). CONCLUSION: Our study demonstrates significant relationship between radiomics parameters, histology, grading and clinical manifestations of thymic tumors.


Assuntos
Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Feminino , Humanos , Iopamidol/análogos & derivados , Masculino , Gradação de Tumores , Estadiamento de Neoplasias , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos
7.
J Vasc Interv Radiol ; 28(7): 978-986, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28495451

RESUMO

PURPOSE: To compare image quality and diagnostic performance of cone-beam computed tomography (CT) and multidetector CT in the detection of hypervascular hepatocellular carcinoma (HCC) in patients with cirrhosis undergoing transarterial chemoembolization with drug-eluting embolic agents. MATERIALS AND METHODS: Fifty-five consecutive patients referred for chemoembolization of hypervascular HCC were prospectively enrolled. Imaging included preprocedural multidetector CT within 1 month before planned treatment, intraprocedural cone-beam CT, and 1-month follow-up multidetector CT. Analysis of image quality was performed with calculations of lesion-to-liver contrast-to-noise ratio (LLCNR) and lesion-to-liver signal-to-noise-ratio (LLSNR). One-month follow-up multidetector CT was considered the reference standard for the detection of HCC nodules. RESULTS: Median LLCNR values were 3.94 (95% confidence interval [CI], 3.06-5.05) for preprocedural multidetector CT and 6.90 (95% CI, 5.17-7.77) for intraprocedural cone-beam CT (P < .0001). Median LLSNR values were 11.53 (95% CI, 9.51-12.44) for preprocedural multidetector CT and 9.36 (95% CI, 8.12-10.39) for intraprocedural cone-beam CT (P < .0104). Preprocedural multidetector CT detected 115 hypervascular nodules with typical HCC behavior, and cone-beam CT detected 15 additional hypervascular nodules that were also visible on 1-month follow-up multidetector CT. CONCLUSIONS: Cone-beam CT has a significantly higher diagnostic performance compared with preprocedural multidetector CT in the detection of HCCs and can influence management of patients with cirrhosis by identifying particularly aggressive tumors.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Tomografia Computadorizada Multidetectores/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Razão Sinal-Ruído
9.
Hepatology ; 59(2): 461-70, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23843206

RESUMO

UNLABELLED: Nonalcoholic fatty liver disease (NAFLD) may increase the risk for cardiac dysfunction. The present study aimed to determine whether, in children, NAFLD is associated with subclinical left ventricular (LV) structural and functional abnormalities independently of metabolic risk factors. We performed a complete echocardiographic study including tissue Doppler imaging, magnetic resonance imaging (MRI) for measurement of hepatic fat fraction (HFF) and abdominal fat mass distribution, along with lipid profile, insulin sensitivity, and high-sensitivity C-reactive protein in 108 obese children, 54 with (HFF ≥5%) and 54 without NAFLD, and 18 lean healthy subjects. The three groups were matched for age, gender, and pubertal status, and obese children with NAFLD were matched for body mass index/standard deviation score with those without NAFLD. Forty-one of the children with NAFLD underwent liver biopsy. Compared to controls and children without liver involvement, those with NAFLD had features of LV diastolic dysfunction, including higher E-to-e' ratio and lower e' tissue velocity. The Tei index (reflecting the combined systolic and diastolic LV function) was also significantly higher in NAFLD children. Among children with biopsy-proven NAFLD, 26 had definite nonalcoholic steatohepatitis (NASH) and 15 were not-NASH. Patients with definite-NASH had significantly lower e' velocity and significantly higher E-to-e' and Tei index (P < 0.001, respectively) than those without NASH. In multiple logistic regression analysis, NAFLD was the only statistically significant variable associated with increased E-to-e' ratio, whereas NAFLD and systolic blood pressure were significantly associated with increased Tei index. CONCLUSION: Asymptomatic obese children with NAFLD exhibit features of early LV diastolic and systolic dysfunction, and these abnormalities are more severe in those with NASH.


Assuntos
Fígado Gorduroso/complicações , Fígado Gorduroso/epidemiologia , Obesidade/complicações , Obesidade/epidemiologia , Disfunção Ventricular Esquerda/epidemiologia , Adolescente , Biópsia , Proteína C-Reativa/metabolismo , Estudos de Casos e Controles , Criança , Comorbidade , Estudos Transversais , Ecocardiografia , Fígado Gorduroso/metabolismo , Feminino , Humanos , Resistência à Insulina/fisiologia , Lipídeos/sangue , Fígado/patologia , Imageamento por Ressonância Magnética , Masculino , Hepatopatia Gordurosa não Alcoólica , Obesidade/metabolismo , Prevalência , Análise de Regressão , Fatores de Risco , Disfunção Ventricular Esquerda/diagnóstico por imagem , Disfunção Ventricular Esquerda/patologia
10.
Eur Radiol ; 25(5): 1310-6, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25417130

RESUMO

OBJECTIVE: Evaluate the performance of a robotic system for CT-guided lung biopsy in comparison to the conventional manual technique. MATERIALS AND METHODS: One hundred patients referred for CT-guided lung biopsy were randomly assigned to group A (robot-assisted procedure) or group B (conventional procedure). Size, distance from entry point and position in lung of target lesions were evaluated to assess homogeneity differences between the two groups. Procedure duration, dose length product (DLP), precision of needle positioning, diagnostic performance of the biopsy and rate of complications were evaluated to assess the clinical performance of the robotic system as compared to the conventional technique. RESULTS: All biopsies were successfully performed. The size (p = 0.41), distance from entry point (p = 0.86) and position in lung (p = 0.32) of target lesions were similar in both groups (p = 0.05). Procedure duration and radiation dose were significantly reduced in group A as compared to group B (p = 0.001). Precision of needle positioning, diagnostic performance of the biopsy and rate of complications were similar in both groups (p = 0.05). CONCLUSION: Robot-assisted CT-guided lung biopsy can be performed safely and with high diagnostic accuracy, reducing procedure duration and radiation dose in comparison to the conventional manual technique. KEY POINTS: • CT-guided biopsy is the main procedure to obtain diagnosis in lung tumours. • The robotic device facilitates percutaneous needle placement under CT guidance. • Robot-assisted CT-guided lung biopsy reduces procedure duration and radiation dose.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/patologia , Radiografia Intervencionista/métodos , Robótica/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Biópsia Guiada por Imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
11.
Int J Hyperthermia ; 31(3): 240-50, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25786982

RESUMO

Focused ultrasound surgery (FUS) is a non-invasive method for tissue ablation that has the potential for complete and controlled local tumour destruction with minimal side effects. The treatment of abdominal organs such as the liver, however, requires particular technological support in order to enable a safe, efficient and effective treatment. As FUS is applied from outside the patient's body, suitable imaging methods, such as magnetic resonance imaging or diagnostic ultrasound, are needed to guide and track the procedure. To facilitate an efficient FUS procedure in the liver, the organ motion during breathing and the partial occlusion by the rib cage need to be taken into account in real time, demanding a continuous patient-specific adaptation of the treatment configuration. Modelling the patient's respiratory motion and combining this with tracking data improves the accuracy of motion predictions. Modelling and simulation of the FUS effects within the body allows the use of treatment planning and has the potential to be used within therapy to increase knowledge about the patient status. This article describes integrated model-based software for patient-specific modelling and prediction for FUS treatments of moving abdominal organs.


Assuntos
Abdome/cirurgia , Imageamento por Ressonância Magnética/métodos , Procedimentos Cirúrgicos Ultrassônicos/métodos , Terapia por Ultrassom/métodos , Humanos , Resultado do Tratamento
14.
BMC Gastroenterol ; 14: 204, 2014 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-25471120

RESUMO

BACKGROUND: Efforts to identify cell sources and approaches for cell therapy of liver diseases are ongoing, taking into consideration the limits recognized for adult liver tissue and for other forms of stem cells. In the present study, we described the first procedure of via hepatic artery transplantation of human fetal biliary tree stem cells in patients with advanced cirrhosis. METHODS: The cells were immune-sorted from human fetal biliary tree by protocols in accordance with current good manufacturing practice (cGMP) and extensively characterized. Two patients with advanced liver cirrhosis (Child-Pugh C) have been submitted to the procedure and observed through a 12 months follow-up. RESULTS: The resulting procedure was found absolutely safe. Immuno-suppressants were not required, and the patients did not display any adverse effects correlated with cell transplantation or suggestive of immunological complications. From a clinical point of view, both patients showed biochemical and clinical improvement during the 6 month follow-up and the second patient maintained a stable improvement for 12 months. CONCLUSION: This report represents proof of the concept that the human fetal biliary tree stem cells are a suitable and large source for cell therapy of liver cirrhosis. The isolation procedure can be carried out under cGMP conditions and, finally, the infusion procedure is easy and safe for the patients. This represents the basis for forthcoming controlled clinical trials.


Assuntos
Transplante de Tecido Fetal/métodos , Cirrose Hepática/terapia , Transplante de Células-Tronco/métodos , Idoso , Antígenos de Neoplasias/metabolismo , Sistema Biliar/citologia , Moléculas de Adesão Celular/metabolismo , Molécula de Adesão da Célula Epitelial , Feminino , Artéria Hepática , Humanos , Masculino
16.
Cancers (Basel) ; 14(18)2022 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-36139581

RESUMO

Hepatocellular carcinoma (HCC) usually develops in cirrhotic liver, with high recurrence rates. However, considering its increasing detection in non-cirrhotic liver, the choice of treatment assumes particular relevance. This study aimed to investigate outcomes of patients among BCLC stages and enrolled for surgical resection (SR) according to a more complex evaluation, to establish its safety and efficacy. A total of 186 selected HCC patients (median age 73.2 yrs), submitted to SR between January 2005 and January 2021, were retrospectively analyzed. Of which, 166 were staged 0, A, B according to the BCLC system, while 20 with a single large tumor (>5 cm) were classified as stage AB. No perioperative mortality was recorded; complications occurred in 48 (25.80%) patients, and all but two were Clavien−Dindo grade I−II. Median follow-up was 9.2 years. Subsequently, 162 recurrent patients (87,1%) were selected for new treatments. Comparable overall survival rates (OS) were observed at 1, 3, 5, and 10 years in 0, A, B and AB stages (p = 0.2). Eventually, the BCLC-B group was matched to 40 BCLC-B patients treated (2015-2021) with TACE. Significant differences in baseline characteristics (p <0.0001) and in OS were observed at 1 and 3 years (p <0.0001); a significant difference was also observed in oncological outcomes, in terms of the absence, residual, or relapse of disease (p <0.05). Surgery might be a valid treatment in HCC for patients affected by chronic liver disease in a condition of compensation, up to BCLC-B stage. Surgical indication for liver resection in case of HCC should be extensively revised.

17.
Neuroradiol J ; 34(6): 607-614, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34028300

RESUMO

BACKGROUND AND PURPOSE: Percutaneous spine biopsies for spondylodiscitis have been long discussed due to the low microbiologic yield. This retrospective study evaluated factors of cone beam computed tomography-guided spine biopsies that may affect microbiologic yield. METHODS: We retrospectively reviewed percutaneous spine biopsies under cone beam computed tomography for spondylodiscitis performed from January 2015-December 2020. Clinical and technical features such as the time from initial symptoms to biopsy, level biopsied, biopsy needle type/gauge, technical approach, radiation dose, technical success and microbiologic yield were recorded. Pre-procedure magnetic resonance imaging findings were also recorded such as the number of vertebral bodies involved, and disc morphology. Univariate logistic regression analysis and Receiver operating characteristic analysis were performed to assess any relationship between relevant factors and positive cultures. RESULTS: A total of 50 patients underwent cone beam computed tomography-guided biopsies for spondylodiscitis, with resulted positive cultures in 18 patients (36%). The mean time from the initial referral of spinal symptoms to procedure in the positive culture group was the most influential finding for positive cultures (odds ratio 56.3, p < 0.001). Among magnetic resonance imaging findings, thin or degenerated intervertebral disc was a negative factor for positive cultures (odds ratio 0.09, p = 0.006). Univariate analysis showed that percutaneous approach (transpedicular vs posterolateral/interlaminar) needle size (11-13 g vs 16-18G, odds ratio 1.2, p = 0.7) and site of biopsy (disc vs bone vs disc plus endplate) did not significantly affect the microbiologic yield of spine biopsy. CONCLUSION: Percutaneous cone beam computed tomography-guided biopsy for spondylodiscitis is a reliable and safe technique and its microbiologic yield may increase if biopsy is performed within the acute phase of infection.


Assuntos
Discite , Tomografia Computadorizada de Feixe Cônico , Discite/diagnóstico por imagem , Humanos , Biópsia Guiada por Imagem , Estudos Retrospectivos , Coluna Vertebral
18.
Liver Cancer ; 10(5): 522-534, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34721513

RESUMO

INTRODUCTION: The aim of this multicenter comparison of balloon-occluded transarterial chemoembolization (B-TACE) versus conventional TACE (cTACE) in treating hepatocellular carcinoma (HCC) was to assess in which size range the 2 techniques offered higher complete response (CR) and objective response (OR) rates in a single session, and to evaluate the possibility of using B-TACE to reduce the need for re-treatment. METHODS: 325 patients were retrospectively evaluated: 91 patients in the B-TACE group (22 with cTACE [B-cTACE] and 69 with drug-eluting microsphere TACE [B-DEM-TACE]) and 234 in the cTACE group. The results were compared according to tumor size: (A) <30 mm, (B) 30-50 mm, and (C) >50 mm; OR and CR rates after the first session and the number of TACE re-interventions within a 6-month period were also evaluated using propensity score matching (PSM). RESULTS: The best target ORs were very high (93.2%) and similar between the 2 treatments both before (94.4% for cTACE and 90.1% for B-TACE) and after PSM (94.5% for cTACE and 90.1%; p = 0.405), with slightly better results for the cTACE cohort probably due to better cTACE effectiveness in smaller lesions. In lesions <30 mm, cTACE obtained a slightly higher CR rate than B-TACE (61.9 vs. 56.3%, p = 0.680), whereas in intermediate-sized HCCs (30-50 mm), B-TACE showed a significant superiority in achieving a CR (72.3 vs. 54.1%, respectively; p = 0.047). In larger lesions (>50 mm), cTACE and B-TACE performed equally, with a poor CR rate (22.6 vs. 23.1%, respectively; p = 1.000). These results were additionally confirmed using PSM. The patients treated with B-TACE had a significantly lower re-treatment rate than the cTACE cohort (12.1 vs. 26.9%, respectively; p = 0.005). B-cTACE and B-DEM-TACE demonstrated similar ORs, with a slightly better CR rate for B-cTACE (68.2 vs. 56.5%, respectively; p = 0.456). CONCLUSION: In HCCs of 30-50 mm, B-TACE should be preferred to cTACE, whereas in smaller nodules (<30 mm), cTACE can suffice in achieving a good CR rate. The statistically significant lower re-treatment rate of the B-TACE cohort after a single procedure reduced the risk of complications due to multiple TACE, which could worsen the patient prognosis.

19.
Med Ultrason ; 23(4): 402-409, 2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34113931

RESUMO

AIMS: To evaluate the pre-surgical diagnostic value of Multiparametric Ultrasound (MPUS) and Fine Needle Aspiration Cytology (FNAC) in differentiating parotid gland tumors, comparing the results with histology. MATERIALS AND METHODS: The study enrolled 84 patients with parotid gland lesions surgically treated in a single tertiary center and evaluated by MPUS. Each patient underwent FNAC. Histological examination was considered the gold standard. RESULTS: Histology identified 62 benign tumors and 22 malignancies. In the differential diagnosis between malignant and benign lesions, B-mode Ultrasound (US), Color-Doppler US, Contrast-Enhanced US (CEUS), Elastography (USE) and FNAC showed the following values of sensitivity: 82%, 81%, 86%, 77%, 73% respectively; specificity: 97%, 61%, 95%, 71%, 97% respectively; PPV: 90%, 43%, 86%, 50%, 89% respectively; NPV: 93%, 90%, 95%, 88%, 91% respectively; and accuracy: 89%, 71%, 90%, 78%, 84% re-spectively. CONCLUSIONS: CEUS proved to be a valid and accurate method for identifying malignant tumors of parotid gland; the combination of B-mode US with CEUS showed similar diagnostic accuracy, but better sensitivity than CEUS taken alone. USE did not improve the diagnostic performance of the B-mode US, alone or in association with CEUS; however, it revealed the highest diagnostic accuracy in the differentiation between benign lesions. FNAC demonstrated lower values in comparison with CEUS and with USE. Therefore, according to our study, MPUS could be proposed as a valid alternative to FNAC.


Assuntos
Glândula Parótida , Neoplasias Parotídeas , Biópsia por Agulha Fina , Humanos , Glândula Parótida/diagnóstico por imagem , Neoplasias Parotídeas/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade
20.
Sci Rep ; 11(1): 15184, 2021 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-34312420

RESUMO

This study aimed to ascertain, for the first time, whether serum magnesium (Mg) concentration is affected by the presence of hepatocellular carcinoma (HCC). We retrospectively enrolled consecutive cirrhotic patients with a diagnosis of HCC (n = 130) or without subsequent evidence of HCC during surveillance (n = 161). Serum levels of Mg were significantly (P < 0.001) lower in patients with HCC than in those without (median [interquartile range]: 1.80 [1.62-1.90] mg/dl vs. 1.90 [1.72-2.08] mg/dl). On multivariate logistic regression, low serum Mg was associated with the presence of HCC (OR 0.047, 95% CI 0.015-0.164; P < 0.0001), independently from factors that can influence magnesaemia and HCC development. In a subset of 94 patients with HCC, a linear mixed effects model adjusted for confounders showed that serum Mg at diagnosis of HCC was lower than before diagnosis of the tumor (ß = 0.117, 95% CI 0.039-0.194, P = 0.0035) and compared to after locoregional treatment of HCC (ß = 0.079, 95% CI 0.010-0.149, P = 0.0259), with two thirds of patients experiencing these changes of serum Mg over time. We hypothesize that most HCCs, like other cancers, may be avid for Mg and behave like a Mg trap, disturbing the body's Mg balance and resulting in lowering of serum Mg levels.


Assuntos
Carcinoma Hepatocelular/sangue , Carcinoma Hepatocelular/complicações , Cirrose Hepática/sangue , Cirrose Hepática/complicações , Neoplasias Hepáticas/sangue , Neoplasias Hepáticas/complicações , Magnésio/sangue , Biomarcadores Tumorais/sangue , Carcinoma Hepatocelular/terapia , Estudos de Casos e Controles , Feminino , Humanos , Neoplasias Hepáticas/terapia , Deficiência de Magnésio/sangue , Deficiência de Magnésio/etiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA