Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
1.
Value Health ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38795957

RESUMO

OBJECTIVES: In 2021, the US Congress passed the Accelerating Access to Critical Therapies for Amyotrophic Lateral Sclerosis Act. The law encourages development of "tools, methods, and processes" to improve clinical trial efficiency for neurodegenerative diseases. The Amyotrophic Lateral Sclerosis Functional Rating Scale-Revised (ALSFRS-R) is an outcome measure administered during in-person clinic visits and used to support investigational studies for persons living with amyotrophic lateral sclerosis. Availability of a standardized, remote-use version of the ALSFRS-R may promote more inclusive, decentralized clinical trials. A scoping literature review was conducted to identify existing remote-use ALSFRS-R tools, synthesize feasibility and comparability of administration modes, and summarize barriers and facilitators to inform development of a standardized remote-use ALSFRS-R tool. METHODS: Included studies reported comparisons between remote and in-person, clinician-reported, ALSFRS-R administration and were published in English (2002-2022). References were identified by searching peer-reviewed and gray literature. Twelve studies met the inclusion criteria and were analyzed to compare findings within and across modes of administration. RESULTS: Remote modes of ALSFRS-R administration were categorized into 4 nonmutually exclusive categories: telephone (n = 6), videoconferencing (n = 3), computer or online platforms (n = 3), mobile applications and wearables (n = 2), and 1 unspecified telemedicine modality (n = 1). Studies comparing in-person to telephone or videoconferencing administration reported high ALSFRS-R rating correlations and nonsignificant between-mode differences. CONCLUSIONS: There is insufficient information in the ALSFRS-R literature to support remote clinician administration for collecting high quality data. Future research should engage persons living with amyotrophic lateral sclerosis, care partners, and providers to develop a standardized remote-use ALSFRS-R version.

2.
Ann Noninvasive Electrocardiol ; 28(6): e13090, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37803819

RESUMO

BACKGROUND: Access to long-term ambulatory recording to detect atrial fibrillation (AF) is limited for economical and practical reasons. We aimed to determine whether 24 h ECG (24hECG) data can predict AF detection on extended cardiac monitoring. METHODS: We included all US patients from 2020, aged 17-100 years, who were monitored for 2-30 days using the PocketECG device (MEDICALgorithmics), without AF ≥30 s on the first day (n = 18,220, mean age 64.4 years, 42.4% male). The population was randomly split into equal training and testing datasets. A Lasso model was used to predict AF episodes ≥30 s occurring on days 2-30. RESULTS: The final model included maximum heart rate, number of premature atrial complexes (PACs), fastest rate during PAC couplets and triplets, fastest rate during premature ventricular couplets and number of ventricular tachycardia runs ≥4 beats, and had good discrimination (ROC statistic 0.7497, 95% CI 0.7336-0.7659) in the testing dataset. Inclusion of age and sex did not improve discrimination. A model based only on age and sex had substantially poorer discrimination, ROC statistic 0.6542 (95% CI 0.6364-0.6720). The prevalence of observed AF in the testing dataset increased by quintile of predicted risk: 0.4% in Q1, 2.7% in Q2, 6.2% in Q3, 11.4% in Q4, and 15.9% in Q5. In Q1, the negative predictive value for AF was 99.6%. CONCLUSION: By using 24hECG data, long-term monitoring for AF can safely be avoided in 20% of an unselected patient population whereas an overall risk of 9% in the remaining 80% of the population warrants repeated or extended monitoring.


Assuntos
Fibrilação Atrial , Complexos Atriais Prematuros , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Triagem , Eletrocardiografia , Eletrocardiografia Ambulatorial
3.
Heart Fail Clin ; 18(2): 223-244, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35341537

RESUMO

Consider these 2 scenarios: Two individuals with heart failure (HF) have recently established with your clinic and followed for medical management and risk stratification. One is a 62-year-old man with nonischemic cardiomyopathy due to viral myocarditis, an ejection fraction (EF) of 40%, occasional rate-limiting dyspnea, and comorbidities of atrial fibrillation and hypertension. The other is a 75-year-old woman with ischemic cardiomyopathy, an EF of 35%, a prior hospitalization 6 months ago, and persistent symptoms of edema and orthopnea. Both have expressed interest in remote patient monitoring (RPM) with wearable and digital health devices that are commercially available such as a smartwatch-ECG, weight scales, and blood pressure monitoring technologies. While there is enthusiasm from both patients and their clinical teams to engage in a technology-driven approach to care, important questions arise such as "What are the patient requirements for participation in digital health programs?", "Can we anticipate improvements in HF status and lower the risk of future HF events including hospitalizations?", "Do the same type of devices in different patients provide accurate information on physiologic changes toward individualized risk assessments?", and "What are the systematic approaches to integrate digital health workflows and datasets from RPM into clinical HF programs?". Given the importance of such questions, embracing new technologies, as a core competency of a modern health care system requires a deeper understanding of how effective digital health programs can be designed to meet the needs of patients and their clinical teams. In this review, we propose a new framework of "Digital Phenotypes in HF" for how new devices and sensors and their respective datasets can be used to guide treatment and to predict disease trajectories within the heterogeneity of HF. Our objectives are to generate a systematic approach to evaluate digital health devices as they relate to the next phase of RPM in HF, to critically analyze the literature, and to apply the lessons learned from digital devices through present-day, real-world evidence examples.


Assuntos
Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Insuficiência Cardíaca/diagnóstico , Humanos , Fenótipo , Volume Sistólico/fisiologia , Função Ventricular Esquerda
4.
J Biomed Inform ; 121: 103869, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34298156

RESUMO

BACKGROUND: Widespread adoption of evidence-based guidelines and treatment pathways in ST-Elevation Myocardial Infarction (STEMI) patients has considerably improved cardiac survival and decreased the risk of recurrent myocardial infarction. However, survival outcomes appear to have plateaued over the last decade. The hope underpinning the current study is to engage data visualization to develop a more holistic understanding of the patient space, supported by principles and techniques borrowed from traditionally disparate disciplines, like cartography and machine learning. METHODS AND RESULTS: The Minnesota Heart Institute Foundation (MHIF) STEMI database is a large prospective regional STEMI registry consisting of 180 variables of heterogeneous data types on more than 5000 patients spanning 15 years. Initial assessment and preprocessing of the registry database was undertaken, followed by a first proof-of-concept implementation of an analytical workflow that involved machine learning, dimensionality reduction, and data visualization. 38 pre-admission variables were analyzed in an all-encompassing representation of pre-index STEMI event data. We aim to generate a holistic visual representation - a map of the multivariate patient space - by training a high-resolution self-organizing neural network consisting of several thousand neurons. The resulting 2-D lattice arrangement of n-dimensional neuron vectors allowed patients to be represented as point locations in a 2-D display space. Patient attributes were then visually examined and contextualized in the same display space, from demographics to pre-existing conditions, event-specific procedures, and STEMI outcomes. Data visualizations implemented in this study include a small-multiple display of neural component planes, composite visualization of the multivariate patient space, and overlay visualization of non-training attributes. CONCLUSION: Our study represents the first known marriage of cartography and machine learning techniques to obtain visualizations of the multivariate space of a regional STEMI registry. Combining cartographic mapping techniques and artificial neural networks permitted the transformation of the STEMI database into novel, two-dimensional visualizations of patient characteristics and outcomes. Notably, these visualizations also drive the discovery of anomalies in the data set, informing corrections applied to detected outliers, thereby further refining the registry for integrity and accuracy. Building on these advances, future efforts will focus on supporting further understanding of risk factors and predictors of outcomes in STEMI patients. More broadly, the thorough visual exploration of display spaces generated through a conjunction of dimensionality reduction with the mature technology base of geographic information systems appears a promising direction for biomedical research.


Assuntos
Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Aprendizado de Máquina , Estudos Prospectivos , Sistema de Registros , Fatores de Risco
5.
J Med Internet Res ; 22(3): e15548, 2020 03 18.
Artigo em Inglês | MEDLINE | ID: mdl-32186521

RESUMO

BACKGROUND: Cardiac and major vascular surgeries are common surgical procedures associated with high rates of postsurgical complications and related hospital readmission. In-hospital remote automated monitoring (RAM) and virtual hospital-to-home patient care systems have major potential to improve patient outcomes following cardiac and major vascular surgery. However, the science of deploying and evaluating these systems is complex and subject to risk of implementation failure. OBJECTIVE: As a precursor to a randomized controlled trial (RCT), this user testing study aimed to examine user performance and acceptance of a RAM and virtual hospital-to-home care intervention, using Philip's Guardian and Electronic Transition to Ambulatory Care (eTrAC) technologies, respectively. METHODS: Nurses and patients participated in systems training and individual case-based user testing at two participating sites in Canada and the United Kingdom. Participants were video recorded and asked to think aloud while completing required user tasks and while being rated on user performance. Feedback was also solicited about the user experience, including user satisfaction and acceptance, through use of the Net Promoter Scale (NPS) survey and debrief interviews. RESULTS: A total of 37 participants (26 nurses and 11 patients) completed user testing. The majority of nurse and patient participants were able to complete most required tasks independently, demonstrating comprehension and retention of required Guardian and eTrAC system workflows. Tasks which required additional prompting by the facilitator, for some, were related to the use of system features that enable continuous transmission of patient vital signs (eg, pairing wireless sensors to the patient) and assigning remote patient monitoring protocols. NPS scores by user group (nurses using Guardian: mean 8.8, SD 0.89; nurses using eTrAC: mean 7.7, SD 1.4; patients using eTrAC: mean 9.2, SD 0.75), overall NPS scores, and participant debrief interviews indicated nurse and patient satisfaction and acceptance of the Guardian and eTrAC systems. Both user groups stressed the need for additional opportunities to practice in order to become comfortable and proficient in the use of these systems. CONCLUSIONS: User testing indicated a high degree of user acceptance of Philips' Guardian and eTrAC systems among nurses and patients. Key insights were provided that informed refinement of clinical workflow training and systems implementation. These results were used to optimize workflows before the launch of an international RCT of in-hospital RAM and virtual hospital-to-home care for patients undergoing cardiac and major vascular surgery.


Assuntos
Doenças Cardiovasculares/cirurgia , Serviços de Assistência Domiciliar/normas , Hospitais/normas , Monitorização Fisiológica/métodos , Interface Usuário-Computador , Idoso , Feminino , Humanos , Masculino , Período Pós-Operatório
6.
J Nucl Cardiol ; 26(4): 1093-1102, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-29214611

RESUMO

BACKGROUND: Several publications and guidelines designate diabetes mellitus (DM) as a coronary artery disease (CAD) risk equivalent. The aim of this investigation was to examine DM cardiac risk equivalence from the perspective of stress SPECT myocardial perfusion imaging (MPI). METHODS AND RESULTS: We examined cardiovascular outcomes (cardiac death or nonfatal MI) of 17,499 patients referred for stress SPECT-MPI. Patients were stratified into four categories: non-DM without CAD, non-DM with CAD, DM without CAD, and DM with CAD, and normal or abnormal perfusion. Cardiac events occurred in 872 (5%), with event-free survival best among non-DM without CAD, worst in DM with CAD, and intermediate in DM without CAD, and non-DM with CAD. After multivariate adjustment, risk remained comparable between DM without CAD and non-DM with CAD [AHR 1.0 (95% CI 0.84-1.28), P =0.74]. Annualized event rates for normal subjects were 1.4% and 1.6% for non-DM with CAD and DM without CAD, respectively (P = 0.48) and 3.5% (P = 0.95) for both abnormal groups. After multivariate adjustment, outcomes were comparable within normal [AHR 1.4 (95% CI 0.98-1.96) P = 0.06] and abnormal [AHR 1.1 (95% CI 0.83-1.50) P = 0.49] MPI. CONCLUSIONS: Diabetic patients without CAD have comparable risk of cardiovascular events as non-diabetic patients with CAD after stratification by MPI results. These findings support diabetes as a CAD equivalent and suggest that MPI provides additional prognostic information in such patients.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Diabetes Mellitus/diagnóstico por imagem , Imageamento por Ressonância Magnética , Imagem de Perfusão do Miocárdio , Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/mortalidade , Complicações do Diabetes/diagnóstico por imagem , Complicações do Diabetes/mortalidade , Diabetes Mellitus/mortalidade , Feminino , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Análise Multivariada , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Prognóstico , Estudos Prospectivos , Estudos Retrospectivos , Risco
7.
Eur Heart J ; 37(18): 1428-38, 2016 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-26873093

RESUMO

The convergence of science and technology in our dynamic digital era has resulted in the development of innovative digital health devices that allow easy and accurate characterization in health and disease. Technological advancements and the miniaturization of diagnostic instruments to modern smartphone-connected and mobile health (mHealth) devices such as the iECG, handheld ultrasound, and lab-on-a-chip technologies have led to increasing enthusiasm for patient care with promises to decrease healthcare costs and to improve outcomes. This 'hype' for mHealth has recently intersected with the 'real world' and is providing important insights into how patients and practitioners are utilizing digital health technologies. It is also raising important questions regarding the evidence supporting widespread device use. In this state-of-the-art review, we assess the current literature of mHealth and aim to provide a framework for the advances in mHealth by understanding the various device, patient, and clinical factors as they relate to digital health from device designs and patient engagement, to clinical workflow and device regulation. We also outline new strategies for generation and analysis of mHealth data at the individual and population-based levels.


Assuntos
Atenção à Saúde , Tecnologia Biomédica , Humanos , Smartphone , Telemedicina
8.
Europace ; 16(1): 47-54, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23954920

RESUMO

AIMS: Hyponatremia is commonly observed among patients with left ventricular (LV) dysfunction and is a marker for adverse outcomes. We aimed to determine the prognostic significance of pre-implant hyponatremia on the outcomes of death, acute decompensated heart failure (ADHF) and appropriate implantable cardioverter-defibrillator (ICD) therapy for ventricular arrhythmias among patients with ICDs. METHODS AND RESULTS: The study population consisted of patients with an ejection fraction ≤40% undergoing ICD implantation (n = 911) for the primary or secondary prevention of sudden cardiac death from 1997 to 2007. The predictive value of the severity of pre-implantation hyponatremia stratified into mild hyponatremia (n = 268, sodium 134-136 mmol/L), moderate hyponatremia (n = 105, sodium 131-133 mmol/L), and severe hyponatremia (n = 31, sodium ≤130 mmol/L) on the risk of death, ADHF, and appropriate ICD therapy for ventricular arrhythmias as compared with patients a normal serum sodium (n = 507, sodium ≥ 137 mmol/L), was calculated using multivariable Cox proportional hazards analyses. During a mean follow-up of 775 ± 750 days as the severity of hyponatremia (from a normal sodium to severe hyponatremia) increased an incremental incidence of death (25% to 61%, P < 0.001) and ADHF (11% to 26%, P = 0.004) was observed with a reduced incidence of ICD therapy for ventricular tachycardia/ventricular fibrillation (37-29%, P = 0.037). Compared with the normal sodium cohort, patients with severe hyponatremia demonstrated an increased risk of death [adjusted hazard ratio (AHR) 2.69 (95% confidence interval, CI 1.57-4.59), P = 0.004] and ADHF [AHR 2.98 (95% CI 1.41-6.30), P = 0.004], with a lower probability of appropriate ICD therapy [AHR 0.68 (95% CI 0.27-0.88), P = 0.031]. CONCLUSION: Hyponatremia is commonly observed among ICD recipients with LV dysfunction. Patients with an increasing severity of hyponatremia are at increased risk of death and HF related morbidity with a reduced incidence of appropriate ICD therapy particularly among patients with severe hyponatremia.


Assuntos
Desfibriladores Implantáveis/estatística & dados numéricos , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Hiponatremia/diagnóstico , Hiponatremia/mortalidade , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/prevenção & controle , Idoso , Comorbidade , Connecticut , Feminino , Humanos , Incidência , Masculino , Cuidados Pré-Operatórios/métodos , Cuidados Pré-Operatórios/estatística & dados numéricos , Prognóstico , Implantação de Prótese/mortalidade , Medição de Risco , Análise de Sobrevida , Resultado do Tratamento
9.
Pacing Clin Electrophysiol ; 37(10): 1315-23, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25139346

RESUMO

BACKGROUND: Inappropriate shocks (IASs) from implantable cardioverter defibrillators (ICDs) are associated with decreased quality of life, but whether they increase healthcare utilization and treatment costs is unknown. We sought to determine the impact of IASs on subsequent healthcare utilization and treatment costs. METHODS: We conducted a case-control analysis of ICD patients at a single institution from 1997 to 2010 and who had ≥12 months of post-ICD implant follow-up. Cases included all patients experiencing an IAS during the first 12 months after implantation. Eligible control patients did not receive a shock of any kind during the 12 months after implantation. Propensity scores based on 36 covariates (area under curve = 0.78) were used to match cases to controls. We compared the rate (occurrences/person year [PY]) of healthcare utilization immediately following IAS to the end of the 12-month follow-up period to the rate in the no-shock group over 12 months of follow-up. We also compared 12-month postimplant treatment (outpatient clinic, emergency room, and hospitalization) costs in both groups. RESULTS: A total of 76 patients experiencing ≥1 IAS during the first 12 months after implant (contributing 48 PYs) were matched to 76 no-shock patients (contributing 76 PYs). Cardiovascular (CV)-related clinic visit and hospitalization rates were increased following an IAS compared to those not receiving a shock (4.0 vs 3.3 and 0.7 vs 0.5, respectively, P = 0.02 for both). CV-related emergency room visitation (0.15 vs 0.08) rates were also numerically higher following an IAS, but did not reach statistical significance (P = 0.26). Patients experiencing an IAS accrued greater treatment costs during the 12 months postimplant compared to no-shock patients ($13,973 ± $46,345 vs $6,790 ± $19,091, P = 0.001). CONCLUSION: Recipients of IAS utilize the healthcare system more frequently following an IAS than patients not experiencing a shock. This increased utilization results in higher costs of treating IAS patients during the 12 months postimplant.


Assuntos
Desfibriladores Implantáveis , Falha de Equipamento/economia , Custos de Cuidados de Saúde , Aceitação pelo Paciente de Cuidados de Saúde , Idoso , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Estudos Retrospectivos
10.
Eur Heart J Imaging Methods Pract ; 2(1): qyae035, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39045181

RESUMO

Aims: A comparison of diagnostic performance comparing AI-QCTISCHEMIA, coronary computed tomography angiography using fractional flow reserve (CT-FFR), and physician visual interpretation on the prediction of invasive adenosine FFR have not been evaluated. Furthermore, the coronary plaque characteristics impacting these tests have not been assessed. Methods and results: In a single centre, 43-month retrospective review of 442 patients referred for coronary computed tomography angiography and CT-FFR, 44 patients with CT-FFR had 54 vessels assessed using intracoronary adenosine FFR within 60 days. A comparison of the diagnostic performance among these three techniques for the prediction of FFR ≤ 0.80 was reported. The mean age of the study population was 65 years, 76.9% were male, and the median coronary artery calcium was 654. When analysing the per-vessel ischaemia prediction, AI-QCTISCHEMIA had greater specificity, positive predictive value (PPV), diagnostic accuracy, and area under the curve (AUC) vs. CT-FFR and physician visual interpretation CAD-RADS. The AUC for AI-QCTISCHEMIA was 0.91 vs. 0.76 for CT-FFR and 0.62 for CAD-RADS ≥ 3. Plaque characteristics that were different in false positive vs. true positive cases for AI-QCTISCHEMIA were max stenosis diameter % (54% vs. 67%, P < 0.01); for CT-FFR were maximum stenosis diameter % (40% vs. 65%, P < 0.001), total non-calcified plaque (9% vs. 13%, P < 0.01); and for physician visual interpretation CAD-RADS ≥ 3 were total non-calcified plaque (8% vs. 12%, P < 0.01), lumen volume (681 vs. 510 mm3, P = 0.02), maximum stenosis diameter % (40% vs. 62%, P < 0.001), total plaque (19% vs. 33%, P = 0.002), and total calcified plaque (11% vs. 22%, P = 0.003). Conclusion: Regarding per-vessel prediction of FFR ≤ 0.8, AI-QCTISCHEMIA revealed greater specificity, PPV, accuracy, and AUC vs. CT-FFR and physician visual interpretation CAD-RADS ≥ 3.

11.
Pacing Clin Electrophysiol ; 36(7): 878-84, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23614760

RESUMO

BACKGROUND: Several meta-analyses of the implantable cardioverter-defibrillator (ICD) clinical trials have demonstrated that while men derived a mortality reduction with prophylactic ICD implantation, women did not. These trials also observed that women receive less appropriate ICD shock therapy compared to men. We aimed to investigate this "gender-paradox" among a heterogeneous community cohort of patients receiving ICDs. METHODS: We identified 1,445 consecutive patients undergoing ICD implantation from 1997 to 2007. The study population consisted of 582 patients, of whom 291 were women who could be propensity matched to 291 men, based on age, ejection fraction, implantation indication (primary or secondary), etiology of cardiomyopathy (ischemic or nonischemic), and the presence of a cardiac resynchronization therapy-defibrillator (CRT-D) device. The impact of gender difference on the probability of death and appropriate ICD shocks for ventricular arrhythmias was calculated using multivariable Cox proportional hazards analyses. RESULTS: During a mean follow-up of 909 ± 901 days, compared to men, women demonstrated a similar risk of death (25% vs 25%, adjusted hazard ratio [AHR] 1.05 [95% confidence interval (CI) 0.81-1.35], P = 0.74). In contrast, women demonstrated a decreased probability of appropriate ICD-shock therapy (14% vs 19%, AHR 0.80 [95% CI 0.59-0.88], P = 0.03) compared to men, and among cohorts with a nonischemic cardiomyopathy (10% vs 20%, P < 0.001) and CRT-D devices (7% vs 19%, P = 0.01). CONCLUSION: Among a community cohort with ICDs, women have a similar mortality compared to men while experiencing less appropriate ICD therapy. These results support the findings of a lower arrhythmic mortality among women.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/estatística & dados numéricos , Cardioversão Elétrica/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Pontuação de Propensão , Idoso , Feminino , Humanos , Incidência , Masculino , Estudos Retrospectivos , Distribuição por Sexo , Taxa de Sobrevida , Resultado do Tratamento , Estados Unidos/epidemiologia
12.
Ann Noninvasive Electrocardiol ; 18(4): 379-88, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23879278

RESUMO

BACKGROUND: Current guidelines consider the implantation of an implantable cardioverter defibrillator (ICD) a class III indication in patients with a life expectancy of <1 year. An evaluation of concomitant noncardiac conditions may identify patients whom may not derive benefit with ICD therapy. We sought to evaluate the association of the Charlson comorbidity index (CCI) on the prediction of early mortality (EM), death <1 year after ICD implant. METHODS: The study population consisted of patients (n = 1062) undergoing ICD implantation for the primary or secondary prevention of sudden cardiac death from 1997 to 2007. The predictive value of the CCI on the risk of EM and appropriate shock therapy for ventricular arrhythmias as compared to patients without EM after ICD implant was calculated using multivariable Cox proportional hazards and receiver operator analyses. RESULTS: Patients experiencing EM (n = 110) demonstrated higher CCI scores (mean 2.8 ± 1.3 vs 1.5 ± 1.2, P < 0.001) as compared to individuals without EM (n = 963). Among patients with a CCI of 0, 1, 2, 3, 4, and ≥5, the incidence of EM increased from 5% to 78%. The CCI was an independent predictor of EM (AHR 1.4 [95% CI 1.2-1.6], P < 0.001, per single score increase). Patients who experienced EM demonstrated a decreased incidence of appropriate ICD therapy when compared to patients without EM (AHR 0.4 [95% CI 0.2-0.7], P = 0.001). CONCLUSION: Noncardiac conditions are commonly observed among patients undergoing ICD implantation. Guidelines must incorporate a comprehensive assessment of concomitant comorbidities to minimize the risk of EM and to maximize the survival benefit with ICD therapy.


Assuntos
Causas de Morte , Comorbidade , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/mortalidade , Expectativa de Vida , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/terapia , Síndrome de Brugada , Doença do Sistema de Condução Cardíaco , Estudos de Coortes , Feminino , Sistema de Condução Cardíaco/anormalidades , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Valor Preditivo dos Testes , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Análise de Sobrevida , Fatores de Tempo , Resultado do Tratamento
13.
Conn Med ; 77(7): 409-15, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24195179

RESUMO

BACKGROUND: Thyroid stimulating hormone (TSH) abnormalities have been associated with various cardiac arrhythmias. Effect of TSH abnormalities on mortality and implantable cardioverter defibrillators (ICD) behavior in patients with cardiomyopathy has not been investigated. METHODS: Our ICD database includes 1,445 patients between December 1997 and January 2008. TSH levels using the ultra sensitive assay were available in 371 patients. Patients were classified based on TSH levels as: High TSH (N = 102, TSH > 5) and Low TSH (N = 26, TSH < 0.4). TSH groups were compared for mortality, appropriate and inappropriate ICD therapies. RESULTS: A high or low TSH was an independent predictor of all-cause mortality: Hazard ratio (HR) 1.46 (95% CI 1.03-2.08), P = 0.033 and HR 1.76 (95% confidence interval 1.02-3.03), P = 0.043 respectively. TSH abnormalities were not associated with an increased incidence in appropriate or inappropriate ICD therapy. CONCLUSION: A low or high TSH was associated with a higher mortality; however, neither were associated with appropriate or inappropriate ICD therapy after multivariate analysis. Univariate analysis demonstrated an association of high TSH and appropriate ICD therapy. However, multivariate analysis did not show this association. Therefore, we are concluding that TSH levels are predictors of all-cause mortality but not ICD therapy.


Assuntos
Arritmias Cardíacas/sangue , Arritmias Cardíacas/terapia , Cardiomiopatias/sangue , Cardiomiopatias/mortalidade , Desfibriladores Implantáveis , Tireotropina/sangue , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/etiologia , Biomarcadores/sangue , Cardiomiopatias/complicações , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Prognóstico
14.
Per Med ; 20(3): 251-269, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37403731

RESUMO

Nanosensors are nanoscale devices that measure physical attributes and convert these signals into analyzable information. In preparation, for the impending reality of nanosensors in clinical practice, we confront important questions regarding the evidence supporting widespread device use. Our objectives are to demonstrate the value and implications for new nanosensors as they relate to the next phase of remote patient monitoring and to apply lessons learned from digital health devices through real-world examples.


Assuntos
Atenção à Saúde , Tecnologia , Humanos
15.
JACC Case Rep ; 28: 102089, 2023 Dec 20.
Artigo em Inglês | MEDLINE | ID: mdl-38204527

RESUMO

Noninvasive infrasonic hemodynography using the MindMics earbuds captures low-frequency acoustic vibrations throughout the cardiac cycle. In an n-of-1 analysis, we propose a new method of assessing severe aortic stenosis by using infrasonic hemodynography to detect its characteristic systolic ejection murmur before and after transcatheter aortic valve replacement.

16.
J Am Heart Assoc ; 12(8): e026974, 2023 04 18.
Artigo em Inglês | MEDLINE | ID: mdl-36942628

RESUMO

Background Diagnosis of shockable rhythms leading to defibrillation remains integral to improving out-of-hospital cardiac arrest outcomes. New machine learning techniques have emerged to diagnose arrhythmias on ECGs. In out-of-hospital cardiac arrest, an algorithm within an automated external defibrillator is the major determinant to deliver defibrillation. This study developed and validated the performance of a convolution neural network (CNN) to diagnose shockable arrhythmias within a novel, miniaturized automated external defibrillator. Methods and Results There were 26 464 single-lead ECGs that comprised the study data set. ECGs of 7-s duration were retrospectively adjudicated by 3 physician readers (N=18 total readers). After exclusions (N=1582), ECGs were divided into training (N=23 156), validation (N=721), and test data sets (N=1005). CNN performance to diagnose shockable and nonshockable rhythms was reported with area under the receiver operating characteristic curve analysis, F1, and sensitivity and specificity calculations. The duration for the CNN to output was reported with the algorithm running within the automated external defibrillator. Internal and external validation analyses included CNN performance among arrhythmias, often mistaken for shockable rhythms, and performance among ECGs modified with noise to mimic artifacts. The CNN algorithm achieved an area under the receiver operating characteristic curve of 0.995 (95% CI, 0.990-1.0), sensitivity of 98%, and specificity of 100% to diagnose shockable rhythms. The F1 scores were 0.990 and 0.995 for shockable and nonshockable rhythms, respectively. After input of a 7-s ECG, the CNN generated an output in 383±29 ms (total time of 7.383 s). The CNN outperformed adjudicators in classifying atrial arrhythmias as nonshockable (specificity of 99.3%-98.1%) and was robust against noise artifacts (area under the receiver operating characteristic curve range, 0.871-0.999). Conclusions We demonstrate high diagnostic performance of a CNN algorithm for shockable and nonshockable rhythm arrhythmia classifications within a digitally connected automated external defibrillator. Registration URL: https://clinicaltrials.gov/ct2/show/NCT03662802; Unique identifier: NCT03662802.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca Extra-Hospitalar , Humanos , Parada Cardíaca Extra-Hospitalar/diagnóstico , Parada Cardíaca Extra-Hospitalar/terapia , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desfibriladores , Algoritmos , Eletrocardiografia , Redes Neurais de Computação , Reanimação Cardiopulmonar/métodos
17.
Ann Noninvasive Electrocardiol ; 17(4): 405-8, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23094889

RESUMO

Bidirectional ventricular tachycardia (BVT) is an uncommon type of polymorphic ventricular tachycardia (PVT) with alternating polarity of the QRS complex most commonly described digitalis toxicity. Recent data has demonstrated the possible molecular basis of this electrocardiographic phenomenon. To our knowledge this is the first reported case of BVT in a patient with orthotopic cardiac transplantation and coronary allograft vasculopathy.


Assuntos
Doença da Artéria Coronariana/diagnóstico por imagem , Eletrocardiografia/métodos , Transplante de Coração , Taquicardia Ventricular/diagnóstico , Taquicardia/diagnóstico , Transplante Homólogo , Amiodarona/uso terapêutico , Antiarrítmicos/uso terapêutico , Doença da Artéria Coronariana/terapia , Desfibriladores Implantáveis , Stents Farmacológicos , Seguimentos , Humanos , Lidocaína/uso terapêutico , Masculino , Pessoa de Meia-Idade , Radiografia , Taquicardia/tratamento farmacológico , Taquicardia/cirurgia , Taquicardia Ventricular/tratamento farmacológico , Taquicardia Ventricular/cirurgia
18.
Per Med ; 19(5): 445-456, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35880428

RESUMO

The application of artificial intelligence (AI) to healthcare has garnered significant enthusiasm in recent years. Despite the adoption of new analytic approaches, medical education on AI is lacking. We aim to create a usable AI primer for medical education. We discuss how to generate a clinical question involving AI, what data are suitable for AI research, how to prepare a dataset for training and how to determine if the output has clinical utility. To illustrate this process, we focused on an example of how medical imaging is employed in designing a machine learning model. Our proposed medical education curriculum addresses AI's potential and limitations for enhancing clinicians' skills in research, applied statistics and care delivery.


The application of artificial intelligence (AI) to healthcare has generated increasing interest in recent years; however, medical education on AI is lacking. With this primer, we provide an overview on how to understand AI, gain exposure to machine learning (ML) and how to develop research questions utilizing ML. Using an example of a ML application in imaging, we provide a practical approach to understanding and executing a ML analysis. Our proposed medical education curriculum provides a framework for healthcare education which we hope will propel healthcare institutions to implement ML laboratories and training environments and improve access to this transformative paradigm.


Assuntos
Inteligência Artificial , Educação Médica , Atenção à Saúde , Humanos , Aprendizado de Máquina
19.
Per Med ; 19(5): 411-422, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35912812

RESUMO

Aim: The COVID-19 pandemic forced medical practices to augment healthcare delivery to remote and virtual services. We describe the results of a nationwide survey of cardiovascular professionals regarding telehealth perspectives. Materials & methods: A 31-question survey was sent early in the pandemic to assess the impact of COVID-19 on telehealth adoption & reimbursement. Results: A total of 342 clinicians across 42 states participated. 77% were using telehealth, with the majority initiating usage 2 months after the COVID-19 shutdown. A variety of video-based systems were used. Telehealth integration requirements differed, with electronic medical record integration being mandated in more urban than rural practices (70 vs 59%; p < 0.005). Many implementation barriers surfaced, with over 75% of respondents emphasizing reimbursement uncertainty and concerns for telehealth generalizability given the complexity of cardiovascular diseases. Conclusion: Substantial variation exists in telehealth practices. Further studies and legislation are needed to improve access, reimbursement and the quality of telehealth-based cardiovascular care.


As the COVID-19 pandemic was just beginning, the American College of Cardiology administered a survey to cardiology professionals across the USA regarding their preparedness for telehealth and video-visits. The results demonstrated rapid adoption of video based telehealth services, however revealed uncertainty for how to best use these services in different practice settings. Many providers expressed concerns about how these visits will be compensated, but fortunately federal agencies have dramatically changed the way telehealth is reimbursed as the pandemic has progressed. Further studies are needed to explore the impact of telehealth on healthcare inequality, however we hope that rather it serves to increase healthcare access to all.


Assuntos
COVID-19 , Cardiologia , Telemedicina , COVID-19/epidemiologia , Estudos Transversais , Humanos , Pandemias , Telemedicina/métodos , Estados Unidos/epidemiologia
20.
NPJ Digit Med ; 5(1): 189, 2022 Dec 22.
Artigo em Inglês | MEDLINE | ID: mdl-36550288

RESUMO

Human bodily mechanisms and functions produce low-frequency vibrations. Our ability to perceive these vibrations is limited by our range of hearing. However, in-ear infrasonic hemodynography (IH) can measure low-frequency vibrations (<20 Hz) created by vital organs as an acoustic waveform. This is captured using a technology that can be embedded into wearable devices such as in-ear headphones. IH can acquire sound signals that travel within arteries, fluids, bones, and muscles in proximity to the ear canal, allowing for measurements of an individual's unique audiome. We describe the heart rate and heart rhythm results obtained in time-series analysis of the in-ear IH data taken simultaneously with ECG recordings in two dedicated clinical studies. We demonstrate a high correlation (r = 0.99) between IH and ECG acquired interbeat interval and heart rate measurements and show that IH can continuously monitor physiological changes in heart rate induced by various breathing exercises. We also show that IH can differentiate between atrial fibrillation and sinus rhythm with performance similar to ECG. The results represent a demonstration of IH capabilities to deliver accurate heart rate and heart rhythm measurements comparable to ECG, in a wearable form factor. The development of IH shows promise for monitoring acoustic imprints of the human body that will enable new real-time applications in cardiovascular health that are continuous and noninvasive.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA