RESUMO
OBJECTIVES: Patent ductus arteriosus (PDA) in elderly patients is an uncommon anomaly, and the duct itself is often calcified and fragile; therefore, transcatheter closure is more difficult. The aim is to analyse periprocedural and one-year follow-up results of transcatheter closure of PDA in such patients. Methods and results. Retrospective analysis of 33 elective patients aged ≥55 years (median 63; 56-85; 29 women), in whom PDA was closed percutaneously between 2002 and 2018 in two tertiary centres. All but three patients were symptomatic, with most in NYHA II (n = 14) and III (n = 11) class; pulmonary hypertension (n = 22), arterial hypertension (n = 22), duct calcifications (n = 17), atrial fibrillation (n = 15), significant mitral regurgitation (n = 5), and decompensated renal failure (n = 2) were observed. Different devices were applied depending on PDA morphology; nitinol wire mesh occluders with symmetrical articulating discs have been the most used in recent years (n = 11). Follow-up was conducted at an outpatient clinic (28/33 patients). The procedure was successful in all patients. There was one embolisation, followed by implantation of a larger device. No major complications were noted. A small residual shunt was present in echocardiography in one patient after one year. NYHA class improved in all but two patients (with multiple comorbidities). CONCLUSIONS: Transcatheter PDA closure in elderly patients is safe and efficient with a high complete closure rate and few complications. Amplatzer duct occluder type II is an attractive device in such patients.
Assuntos
Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Complicações Pós-Operatórias , Implantação de Prótese , Dispositivo para Oclusão Septal , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Desenho de Prótese , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Estudos Retrospectivos , Resultado do TratamentoRESUMO
A 19-year-old woman with atrial septal defect treated percutaneously with an Amplatzer Septal Occluder 24 months earlier, who presented with a history of bacterial meningitis, was admitted with a diagnosis of endocarditis. After 6 weeks of treatment with antibiotics, the incompletely endothelialised occluder was surgically removed. The present report illustrates the need for long-term follow-up of patients who have received nitinol wire mesh occluders.
Assuntos
Endocardite Bacteriana/etiologia , Endotélio , Meningites Bacterianas/etiologia , Complicações Pós-Operatórias/etiologia , Dispositivo para Oclusão Septal/efeitos adversos , Infecções Estafilocócicas/etiologia , Doença Aguda , Feminino , Humanos , Fatores de Tempo , Adulto JovemRESUMO
BACKGROUND: Post-myocardial infarction ventricular septal rupture (VSR) is a rare and severe complication of myocardial infarction. To find early mortality (<30 days) risk factors of device VSR closure and to evaluate its medium-term outcome. METHODS: Multicenter retrospective analysis on all 46 consecutive patients with percutaneous (n = 43) or hybrid (n = 3) VSR closure in 2000-2020 with various nitinol wire mesh occluders. Medical records, hemodynamic data, procedure results, short- and mid-term follow-up were analyzed (4.8 ± 3.7 years, range: 0.1-15, available in 61.7% of patients). Of the patients, 34.8% underwent VSR closure in acute phase (<21 days after VSR occurrence), 17.4% underwent device closure due to significant residual shunt after previous VSR surgery. RESULTS: Success rate was 78.3%. More than moderate residual shunt, major complications, and early surgical reintervention affected 18.9%, 15.2% (including 2 intra-procedural deaths), and 21.7% of patients, respectively. Early mortality was 26.1% (13.9% in successful vs. 70% in unsuccessful closure; p < 0.001). Older age, need for intra-aortic balloon counterpulsation, severe complications, and procedural failure were identified as risk factors for early mortality. Among patients who survived the early period, the 5-year survival rate was 57.1%. NYHA class improved in 88.2% patients at the latest follow-up. CONCLUSIONS: Procedure of VSR device closure demonstrates an acceptable technical success rate; however, the incidence of severe complications and early mortality is notably high. Older patients in poor hemodynamic condition and those with unsuccessful occluder deployment are particularly at a higher risk of a fatal outcome. The prognosis after early survival is promising.
Assuntos
Infarto do Miocárdio , Ruptura do Septo Ventricular , Humanos , Ruptura do Septo Ventricular/diagnóstico , Ruptura do Septo Ventricular/etiologia , Ruptura do Septo Ventricular/cirurgia , Estudos Retrospectivos , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/cirurgia , Infarto do Miocárdio/complicações , Fatores de Risco , Prognóstico , Resultado do TratamentoRESUMO
BACKGROUND: Transcatheter closure of atrial septal defect (ASD) has become the treatment of choice for most patients. About 5% of them suffer from transient headache episodes (THE) after the procedure, whose etiology is unclear. AIMS: To evaluate risk factors for THE occurrence after transcatheter closure of ASD in the pediatric population. METHODS: Eight hundred and forty patients, after transcatheter ASD closure with nitinol devices, from a single center, were included in retrospective analysis. THE was defined as occurring up to 24 hours after the procedure. A logistic regression model including age, weight, ASD diameter, device size, presence of nitinol coating on the device, fluoroscopy time, application of balloon calibration, device oversizing, and residual shunt after 24 hours was created to evaluate risk factors for THE occurrence. RESULTS: There were 40 patients with THE (4.8%), 70% female and 30% male. The median age was 13 (7.35-16) years. In patients with headache, balloon calibration (BC) was performed more frequently (82.5% vs. 43.3%; P <0.001). The balloon waist median (interquartile range [IQR]), 19 (16-22) mm vs. 15 mm (12-18) mm (P <0.001), and device size median (IQR), 18 (13.5-22) mm vs. 14 (11-17) mm (P <0.001) were larger, and residual shunt after 24 hours (12.5% vs. 4.9%; P = 0.03) and a year (7.5 vs. 1.0%; P <0.001) were more frequent. ASD size and the prevalence of double/multiple ASD were similar in both groups. Age, BC application, no nickel release protection, duration of fluoroscopy, and device oversizing were predictors of THE (P <0.001). CONCLUSIONS: BC during percutaneous ASD closure and the lack of a protective layer against nickel release on the device are risk factors for headache occurrence in the early postprocedural period.
Assuntos
Comunicação Interatrial , Dispositivo para Oclusão Septal , Humanos , Criança , Masculino , Feminino , Adolescente , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Estudos Retrospectivos , Comunicação Interatrial/cirurgia , Comunicação Interatrial/etiologia , Cefaleia/etiologia , Resultado do Tratamento , Ecocardiografia Transesofagiana , Dispositivo para Oclusão Septal/efeitos adversosRESUMO
We present two procedures of transcatheter closure: that of an aorto-pulmonary window in a 12-month-old infant with a body weight of 7 kilograms, and that of ruptured sinus of Valsalva aneurysm into the right atrium in an adult patient. In the first case, we applied the muscular ventricular septal defect Cardio-O-Fix, while in the other we applied the patent ductus arteriosus Cardio-O-Fix occluder. The procedures were successful in both patients, and we achieved complete closure of the unwanted shunts.
Assuntos
Aneurisma Aórtico/cirurgia , Ruptura Aórtica/cirurgia , Defeito do Septo Aortopulmonar/cirurgia , Cateterismo Cardíaco , Dispositivo para Oclusão Septal , Seio Aórtico , Humanos , Lactente , Masculino , Pessoa de Meia-IdadeRESUMO
Introduction: Balloon aortic valvuloplasty (BAV) is a common treatment method of aortic valve (AV) stenosis in neonates. Long-term BAV effects are suboptimal, and their predictors are not well acknowledged. Aim: To identify predictors of suboptimal short- and long-term BAV results. Material and methods: The study group comprised forty-three neonates (8 females; weight 3.34 ±0.56 kg) who underwent BAV between 1998 and 2021. Seventeen patients (39.53%) had critical AV stenosis. AV was bicuspid in 22 patients, tricuspid in 12, unicuspid in 2, and undefined in 7 patients. The mean balloon/annulus ratio was 0.9 ±0.07. Catheterization, clinical, and follow-up data were analysed. Results: The peak-to-peak gradient decreased from 67.5 ±26.3 to 21.3 ±12.6 mm Hg. Twenty-eight patients (65.1%) had adequate early outcome. Aortic regurgitation (AR) occurred in 13 (30.2%) patients. No predictors of inadequate early outcome were found. Twenty-year survival was 90.7%. Eleven (35.5%) patients underwent reintervention at a median of 12 (1-215) months; BAV in 5 patients, surgical valvuloplasty in 2, Ross operation in 2, AV replacement in 1, and Norwood operation in 1 patient. Fifteen-year freedom from reintervention (FFR) was 48%. Adequate early outcome resulted in higher FFR (71% vs. 22%), and so did no significant AR (60% vs. 30%). Conclusions: BAV provides satisfying early results. AR remains a significant aftermath of BAV. Risk factors and procedural techniques improving the outcome of BAV are unclear. Further research is needed to improve FFR.
RESUMO
We present an interesting complication of late stent thrombosis after percutaneous treatment of aortic coartaction and a new modality of treatment with radiofrequency perforation and implantation of additional stent to resolve this problem.
Assuntos
Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/instrumentação , Coartação Aórtica/terapia , Ablação por Cateter , Stents , Trombose/cirurgia , Adulto , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/fisiopatologia , Aortografia/métodos , Feminino , Hemodinâmica , Humanos , Trombose/etiologia , Trombose/fisiopatologia , Tomografia Computadorizada por Raios X , Resultado do TratamentoRESUMO
BACKGROUND: The purpose of this study was to assess the effectiveness of cardiac resynchronization therapy (CRT) in terms of outflow tract gradient reduction and functional improvement in symptomatic patients with hypertrophic obstructive cardiomyopathy (HOCM) requiring implantable cardioverter-defibrillator (ICD) implantation. METHODS: Eleven consecutive symptomatic HOCM patients with a significant (≥40 mmHg) gradient and indications for ICD, but without indications for resynchronization, underwent CRT-D implantation. Nine of them (four female, median age of 50 years) in whom the procedure succeeded were screened for New York Heart Association (NYHA) class, outflow gradient, mechanical dyssynchrony, QRS-width change, and 6-minute walking distance (6MWD) and peak oxygen consumption (VO(2)peak) improvement after 6 months and remotely. RESULTS: After 6 months of pacing, NYHA class decreased (median 1 vs 2, respectively); peak (33 vs 84 mmHg) and mean (13 vs 38 mmHg) outflow tract gradients were reduced; and QRS width (143 vs 105 ms), intraventricular dyssynchrony (35 vs 55 ms), and VO(2)peak (19.5 vs 14.2 mL/kg/min) increased significantly (all P < 0.05) compared to baseline. In six of nine patients (67%), the peak gradient was reduced >50% and reached <40 mmHg. After a median of 36 months, the outflow gradient decreased even more (8 mmHg) and was significantly (P < 0.05) lower than after 6 months of CRT. CONCLUSIONS: These preliminary data suggest that CRT seems to be an effective method of reducing the outflow tract gradient and improving the functional status of symptomatic HOCM patients requiring ICD implantation. Our findings need to be confirmed by more extensive studies.
Assuntos
Cardiomiopatia Hipertrófica/diagnóstico , Cardiomiopatia Hipertrófica/prevenção & controle , Desfibriladores Implantáveis , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Adolescente , Idoso , Cardiomiopatia Hipertrófica/complicações , Criança , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Resultado do TratamentoRESUMO
BACKGROUND: Transcatheter patent ductus arteriosus (PDA) closure has become the firstchoice method of treatment in the majority of patients. However, device selection poses a challenge. AIMS: This study aimed to analyze periprocedural and 1year outcomes of PDA transcatheter closure performed with different devices throughout a 25year time period in a single center. METHODS: All 1036 patients who underwent transcatheter PDA closure between 1993 and 2020 were included in retrospective analysis. Various devices were used: the Rashkind device (RD; n = 25), coils (n = 469), nitinol duct occluders type I (DO I; n = 300), type II (n = 32), type II additional sizes (ADO II AS; n = 209), as well as offlabel devices: vascular plugs and atrial septal and muscular ventricular septal defect occluders (n = 17). Data on 24hour and 1year followup were available for 100% and 78.9% of the study patients, respectively. RESULTS: The procedure was successful in 98.6% of the study patients, with a major complication rate of 0.2%. Complete PDA closure after a year was observed in 81.8% of the patients treated with RD, 93.7% of those with coils, and 100% of those with duct occluders. There were no differences between Amplatzer DO I (n = 159) and its DO I copies manufactured in China (n = 141) with regard to success, efficacy, and complication rates. Recently, ADO II AS has replaced coils and become the preferred device to close smalltomoderate PDA. CONCLUSIONS: Transcatheter PDA closure with all types of nitinol duct occluders is safe and effective, with no residual shunting at 1year followup. Due to higher efficacy, ADO II AS has replaced coils in the treatment of smaller PDA.
Assuntos
Permeabilidade do Canal Arterial , Dispositivo para Oclusão Septal , Cateterismo Cardíaco , China , Permeabilidade do Canal Arterial/cirurgia , Humanos , Lactente , Estudos Retrospectivos , Resultado do TratamentoRESUMO
Atrial septal defect is the most common congenital heart lesion in adults. Although atrial septal defect closure is recommended in those with right heart enlargement or paradoxical embolism, data informing such indications in adults are quite limited. This population has many unique characteristics and needs. In recent years, significant progress has been made with regard to diagnostic modalities that facilitate the diagnostic workup of these patients. However, the decisionmaking process, especially in selected adult patients population (advanced age, various concomitant diseases, poor LV function [both systolic and diastolic], pulmonary hypertension, concomitant arrhythmias or multiple defects, or deficient rims) is still not easy. Available data are predominantly focused on imaging endpoints and shortterm morbidity and mortality rather than longterm. The evidence base for outcomes with or without defect closure comes from various studies with different observation periods. Moreover, the clinical experience in diagnosing and treating that subgroup of patients is inhomogeneous between individual physicians (cardiologists, imaging specialists, operators) and between small and large experience centers. In the view of the above, the joint group of experts from the Association of Cardiovascular Interventions and the GrownUp Congenital Heart Disease Section of the Polish Cardiac Society developed the following consensus opinion in order to standardize the principles of diagnosis, indications for treatment, methods of performing procedures, and tenets of postoperative care in Poland.
Assuntos
Cardiopatias Congênitas , Comunicação Interatrial , Cateterismo Cardíaco , Consenso , Cardiopatias Congênitas/cirurgia , Comunicação Interatrial/cirurgia , Humanos , Polônia , Resultado do TratamentoRESUMO
We describe a case of a 21-year-old women with atypical (kinking) native coarctation of aorta. She had arterial hypertension treated pharmacologically. To visualise stenotic segment, standard angiographic planes were not usefull, only right oblique projection showed precisely stenotic segment. Thereafter stent was successfully applied and trans aortic gradient decreased from 30 to 0 mmHg.
Assuntos
Coartação Aórtica/terapia , Stents , Adulto , Coartação Aórtica/diagnóstico , Coartação Aórtica/etiologia , Dilatação/instrumentação , Dilatação/métodos , Feminino , Humanos , Hipertensão/complicaçõesRESUMO
We present 2 cases (4 and 17-year-old children) with aorta-vena azygos fistulae. In the fist child spontaneous closure was confirmed by clinical symptoms and aortography, in the second (with significant left-right shunt) successful closure with 10 x 8 mm Amplatzer Duct Occluder was obtained. These case reports show that the strategy of treatment of aorto-venous fistulae must be individualised.
Assuntos
Aorta/anormalidades , Fístula Arteriovenosa/terapia , Veia Ázigos/anormalidades , Adolescente , Aortografia , Fístula Arteriovenosa/diagnóstico por imagem , Veia Ázigos/diagnóstico por imagem , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardiovasculares , Humanos , Lactente , Masculino , Medicina de Precisão/métodos , Dispositivo para Oclusão SeptalRESUMO
Multislice computed tomography is an imaging method of internal organs including heart and vessels with the use of X-ray. The indications for computed tomography of the heart include also congenital heart diseases and the evaluation of the great arteries. Ultrasonography is a method of choice in heart evaluation. The authors show the possibilities of modern multislice computed tomography in congenital heart diseases imaging based on their own material.
Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Tomografia Computadorizada Espiral , Adulto , Coartação Aórtica/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Intensificação de Imagem Radiográfica/métodos , Tetralogia de Fallot/diagnóstico por imagem , Transposição dos Grandes Vasos/diagnóstico por imagem , Malformações Vasculares/diagnóstico por imagemRESUMO
Transcatheter implantation of pulmonary valve became a big step forward in the field of interventional cardiology. It is especially important in the patients with defects of the right ventricular outlet tract, because they were usually candidates for multiple surgical operations. We present first transcatheter replacement of pulmonary valve in 23-years-old man. The 'Melody' valve was implanted successfully. There were no complications and the patient was discharged in good condition.
Assuntos
Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/terapia , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/complicações , Comunicação Interventricular/cirurgia , Ventrículos do Coração/cirurgia , Humanos , Masculino , Assistência Perioperatória/métodos , Resultado do Tratamento , Disfunção Ventricular Direita/etiologia , Disfunção Ventricular Direita/terapia , Adulto JovemRESUMO
AIM: To assess the early results of the pulmonary artery valve transcatheter implantation (PAVTI) in pts included into POL-PAVTI registry. Detailed medical and economic analyses were performed. METHODS: Pulmonary artery valve implantation was performed in 14 pts (9 men), aged 16-31 (mean 24.6 +/- 4.8) years, with pulmonary homograft dysfunction after total repair of tetralogy of Fallot (4 pts), pulmonary atresia (2 pts), pulmonary stenosis (1 pt), common arterial trunk type I (1 pt), Ross procedure (3 pts) and TGA - Rastelli operation (3 pts). Eleven pts underwent in the past 2-5 surgical or/and catheter interventions. Indication for PAVTI was based on clinical evaluation and echocardiographic studies. Assessment of morphological and functional features of the right ventricle (RV) and homograft with the use of cardiac magnetic resonance (CMR) was performed in 10 cases. Pulmonary stenosis (max. pulmonary gradient 32-119, mean 72 +/- 28 mmHg) was observed in 13 pts and/or significant pulmonary regurgitation in 10 pts. The procedure was performed in general anesthesia. The deployment of a valved stent in the pulmonary valve position was preceded by a metal stent implantation. Results were evaluated by echocardiography two days after the procedure and one month later. Four patients were evaluated 6 months after procedure. RESULTS: Time of the procedure varied 60-190 (mean 127 +/- 35) min, time of fluoroscopy ranged 12-31 (mean 21 +/- 11) min. PAVTI was successfully performed in all pts without serious complications. Patients were discharged from the hospital 48-293 (mean 120 +/- 71) h after procedure. Significant reduction of pulmonary gradient after the procedure assessed by echocardiography was observed on the second day (20-60, mean 38 +/- 12 mmHg, p < 0.0001) and one month (19-52, mean 34 +/- 9 mmHg, p < 0.0001). Mild pulmonary regurgitation was observed in 2 pts. In 5 pts evaluated 6 months after procedure haemodynamic parameters were unchanged; no late complications were observed. Average cost of the procedure including a price of the valve (82 000 PLN) was 98 000 PLN. CONCLUSIONS: Pulmonary artery valve transvascular implantation is an effective and safe method of non-surgical treatment for patients with homograft dysfunction. Cost-effectiveness is approvable.
Assuntos
Cardiopatias Congênitas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Artéria Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Implante de Prótese Vascular/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Ecocardiografia Transesofagiana , Seguimentos , Cardiopatias Congênitas/diagnóstico por imagem , Humanos , Masculino , Polônia , Artéria Pulmonar/anormalidades , Resultado do Tratamento , Obstrução do Fluxo Ventricular Externo/cirurgia , Adulto JovemRESUMO
BACKGROUND: Radiofrequency current ablation (RFCA) is a safe and efficient method of treatment in adult patients with symptomatic arrhythmias. Recently RFCA is being also used in the treatment of children with cardiac arrhythmias, however its value in this set of patients is poorly documented. Aims of our study were to assess the feasibility and safety of RFCA procedures in children with symptomatic supraventricular and ventricular arrhythmias, and to identify the parameters which influence the probability of acute success and RFCA course. METHODS: Consecutive 110 patients aged less than 18, who underwent RFCA due to the symptomatic arrhythmias at our center were included into a retrospective analysis. The patients presented mainly with the preexcitation syndrome (57%), 13.6% had ectopic ventricular arrhythmias, in 17.3% nodal reentrant tachycardia, in 8.2% intraatrial reentry tachycardia (IART), whereas in 5.4% ectopic atrial tachycardia (EAT) was diagnosed. Three patients had multiple arrhythmias. In ten subjects congenital heart defect was diagnosed in the past, which was treated surgically in 8. Analyzed parameters included: RFCA success-rate, procedure duration, fluoroscopy-time, perioperative complications and arrhythmia recurrence-rate during 6 months follow-up. RESULTS: Ablation was successful in 101 (91.8%) patients and abolished 104 out of 113 (92%) treated arrhythmias. Out of 9 patients with unsuccessful RFCA, three had congenital heart defect. Two complications occurred intra-operatively in two patients: in one patient pneumothorax was observed following jugular vein puncture, which resolved spontaneously without the need of drainage, in the second patient transient atrioventricular conduction block occurred during radiofrequency current application. Mean procedure duration in the studied population was 118.9 +/- 46 min, fluoroscopy exposure equaled 22.3 +/- 17min. In twelve patients (10.9%) arrhythmia recurred during the follow-up period. The longest procedure duration was observed in patients with EAT and IART, the longest fluoroscopy-time in subjects with IART, whereas the shortest fluoroscopy was observed in patients with the ventricular ectopic arrhythmias. Success-rates, complications, and recurrence-rates did not differ irrespectively from arrhythmia treated. The only independent predictor of unsuccessful RFCA was the presence of congenital cardiac defect (adjusted OR 0.15, p<0.05). The presence of cardiac defect, procedure performed without electroanatomic mapping system and less experienced operators were the parameters associated with longer fluoroscopic exposure. CONCLUSIONS: Radiofrequency current ablation is a safe and efficient method of treatment in children with arrhythmias. The presence of congenital heart defect was a factor influencing unfavorably the probability of successful RFCA. Procedural course was related to the experience of electrophysiology team, the use of advanced mapping systems and presence of cardiac defect.