Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Pathol ; 76(3): 177-184, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34645702

RESUMO

AIMS: The COVID-19 pandemic, and the focus on mitigating its effects, has disrupted diabetes healthcare services worldwide. We aimed to quantify the effect of the pandemic on diabetes diagnosis/management, using glycated haemoglobin (HbA1c) as surrogate, across six UK centres. METHODS: Using routinely collected laboratory data, we estimated the number of missed HbA1c tests for 'diagnostic'/'screening'/'management' purposes during the COVID-19 impact period (CIP; 23 March 2020 to 30 September 2020). We examined potential impact in terms of: (1) diabetes control in people with diabetes and (2) detection of new diabetes and prediabetes cases. RESULTS: In April 2020, HbA1c test numbers fell by ~80%. Overall, across six centres, 369 871 tests were missed during the 6.28 months of the CIP, equivalent to >6.6 million tests nationwide. We identified 79 131 missed 'monitoring' tests in people with diabetes. In those 28 564 people with suboptimal control, this delayed monitoring was associated with a 2-3 mmol/mol HbA1c increase. Overall, 149 455 'screening' and 141 285 'diagnostic' tests were also missed. Across the UK, our findings equate to 1.41 million missed/delayed diabetes monitoring tests (including 0.51 million in people with suboptimal control), 2.67 million screening tests in high-risk groups (0.48 million within the prediabetes range) and 2.52 million tests for diagnosis (0.21 million in the pre-diabetes range; ~70 000 in the diabetes range). CONCLUSIONS: Our findings illustrate the widespread collateral impact of implementing measures to mitigate the impact of COVID-19 in people with, or being investigated for, diabetes. For people with diabetes, missed tests will result in further deterioration in diabetes control, especially in those whose HbA1c levels are already high.


Assuntos
COVID-19 , Estado Pré-Diabético , Humanos , Estado Pré-Diabético/diagnóstico , Estado Pré-Diabético/epidemiologia , COVID-19/epidemiologia , Hemoglobinas Glicadas , Pandemias , Reino Unido/epidemiologia , Teste para COVID-19
2.
J Diabetes Res ; 2022: 7093707, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35615258

RESUMO

Aims: We previously showed that the glycated haemoglobin (HbA1c) testing frequency links to diabetes control. Here, we examine the effect of variability in test interval, adjusted for the frequency, on change in HbA1c (ΔHbA1c). Materials & Methods. HbA1c results were collected on 83,872 people with HbA1c results at baseline and 5 years (±3 months) later and ≥6 tests during this period. We calculated the standard deviation (SD) of test interval for each individual and examined the link between deciles of SD of the test interval and ΔHbA1c level, stratified by baseline HbA1c. Results: In general, less variability in testing frequency (more consistent monitoring) was associated with better diabetes control. This was most evident with moderately raised baseline HbA1c levels (7.0-9.0% (54-75 mmol/mol)). For example, in those with a starting HbA1c of 7.0-7.5% (54-58 mmol/mol), the lowest SD decile was associated with little change in HbA1c over 5 years, while for those with the highest decile, HbA1c rose by 0.4-0.6% (4-6 mmol/mol; p < 0.0001). Multivariate analysis showed that the association was independent of the age/sex/hospital site. Subanalysis suggested that the effect was most pronounced in those aged <65 years with baseline HbA1c of 7.0-7.5% (54-58 mmol/mol). We observed a 6.7-fold variation in the proportion of people in the top-three SD deciles across general practices. Conclusions: These findings indicate that the consistency of testing interval, not the just number of tests/year, is important in maintaining diabetes control, especially in those with moderately raised HbA1c levels. Systems to improve regularity of HbA1c testing are therefore needed, especially given the impact of COVID-19 on diabetes monitoring.


Assuntos
Diabetes Mellitus Tipo 2 , Hemoglobinas Glicadas , Diabetes Mellitus Tipo 2/diagnóstico , Hemoglobinas Glicadas/análise , Humanos , Análise Multivariada , Reprodutibilidade dos Testes
3.
Ann Surg ; 251(6): 1092-7, 2010 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20485132

RESUMO

OBJECTIVE: The aim of this study was to examine by screening angiography the anatomy of the small arteries and their collaterals in colorectal resections in order to identify factors that might be implicated in anastomotic leak. SUMMARY BACKGROUND DATA: Anastomotic leak is more frequent following low anterior resection. Vascular compromise is frequently implicated but poorly understood as a mechanism. METHODS: High definition screening angiography was performed on 17 colorectal resection specimens. RESULTS: (1) The small arteries of the colon (the vasa recta that arise from the marginal artery) show variability in their spacing and in their collaterals based on their anatomical positions. At the splenic flexure and the proximal and mid descending colons, the vasa recta are spaced 2-cm apart and have few collaterals. At the right, transverse, distal descending and sigmoid colons, the vasa recta are spaced <1 cm apart and have more extensive collaterals. (2) The small arteries of the rectum are spaced <1 cm apart and also show variability in their collaterals based on their anatomical level. In the mid-to-upper rectum there are good collaterals between the small arteries within the mesorectum based upon the bifurcation of the superior rectal artery and its main branches. In the lower rectum, however, there are only a few and very variable intramural collaterals between the small arteries. CONCLUSIONS: Based on these findings, unrecognized disruption of small artery collaterals during colorectal resection might be implicated in anastomotic leak and in particular might explain the higher leak rate in low anterior resection.


Assuntos
Angiografia , Circulação Colateral , Neoplasias Colorretais/irrigação sanguínea , Idoso , Anastomose Cirúrgica/efeitos adversos , Arteríolas/anatomia & histologia , Arteríolas/diagnóstico por imagem , Colo/irrigação sanguínea , Neoplasias Colorretais/cirurgia , Feminino , Humanos , Masculino , Reto/irrigação sanguínea
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA