Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anesth Analg ; 131(2): e52-e54, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31335404

RESUMO

Little is known about respecting the recommended range of bispectral index (BIS) in practice. This exploratory retrospective analysis of 138 robotic surgical patients having received total intravenous anesthesia shows that BIS was between 40 and 60 during 61.3% ± 25.2% (mean ± standard deviation [SD]) of maintenance, >60 during 3.1% ± 5.5%, and <40 during 35.7% ± 26.9%. Burst suppression was present during 17.8% ± 22.2%. Female sex is associated with increased periods of BIS <40 (P = .002) as is body mass index (BMI) <26 (P = .012). Increased age is associated with increase in burst suppression (P = .005). A larger study is required to confirm the role of patients' factors on the number of periods of low BIS.


Assuntos
Anestesia Intravenosa/métodos , Índice de Massa Corporal , Monitores de Consciência , Eletroencefalografia/métodos , Monitorização Intraoperatória/métodos , Fatores Etários , Feminino , Humanos , Masculino , Estudos Retrospectivos , Procedimentos Cirúrgicos Robóticos/métodos , Fatores Sexuais
2.
Medicine (Baltimore) ; 100(22): e26129, 2021 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-34087863

RESUMO

ABSTRACT: Early detection of arterial hypotension during cesarean delivery under spinal anesthesia is important. This study aims to compare the validity of NexfinTM as beat-to-beat noninvasive blood pressure monitoring with conventional intermittent oscillometric measurement of blood pressure during elective cesarean delivery.This open prospective observational bicentric study was performed between January 2013 and December 2015. We simultaneously recorded arterial blood pressure with both techniques in pregnant women undergoing elective cesarean delivery under spinal anesthesia. The primary outcome was a Bland-Altman analysis of systolic blood pressure measurement comparing NexfinTM and a conventional method. The secondary outcomes were the time to detect the first relevant hypotensive episode and the comparison of both devices using a four-quadrant graph.One hundred and seventy-four parturients completed the study, and 2640 pairs of systolic blood pressure measurements were analyzed. Bias was -10 mmHg with upper and lower limits of agreement of -61 and +41 mmHg. In 73.9% of the cases, the two techniques provided the same information (normotension or hypotension), but the conventional method missed 20.8% of measurements, with NexfinTM detecting 16.2% more hypotensive measurements. The median [25-75 percentiles] duration to detect the first hypotensive measurement was 331 [206-480] seconds for NexfinTM and 440 [300-500] s for intermittent oscillometry (P < .001).The agreement between NexfinTM and an intermittent method for the measurement of systolic blood pressure was not in an acceptable range during cesarean delivery, although NexfinTM may detect hypotension earlier than the standard method.Trial registration: Clinicaltrials.gov identifier: NCT01732133; November 22, 2012.


Assuntos
Raquianestesia/efeitos adversos , Determinação da Pressão Arterial/métodos , Cesárea/métodos , Hipotensão/induzido quimicamente , Hipotensão/diagnóstico , Adulto , Índice de Apgar , Pressão Arterial , Determinação da Pressão Arterial/normas , Monitores de Pressão Arterial , Pesos e Medidas Corporais , Feminino , Humanos , Gravidez , Estudos Prospectivos , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA