Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Clin Infect Dis ; 69(10): 1724-1730, 2019 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-30668657

RESUMO

BACKGROUND: Early secretory antigenic target-6 (ESAT-6) is an immunodominant Mycobacterium tuberculosis (M.tb) antigen included in novel vaccines against tuberculosis (TB) and in interferon-gamma (IFN-γ) release assays (IGRAs). Therefore, the availability of an ESAT-6-free IGRA is essential to determine M.tb infection status following vaccination with ESAT-6-containing vaccines. We aimed to qualify a recently developed ESAT-6-free IGRA and to assess its diagnostic performance in comparison to QuantiFERON-TB Gold In-tube (QFT). METHODS: Participants with different levels of M.tb exposure and TB disease were enrolled to determine the ESAT-6-free IGRA cutoff, test assay performance in independent cohorts compared to standard QFT, and perform a technical qualification of antigen-coated blood collection tubes. RESULTS: ESAT-6-free IGRA antigen recognition was evaluated in QFT-positive and QFT-negative South African adolescents. The ESAT-6-free IGRA cutoff was established at 0.61 IU/mL, based on receiver operating characteristic analysis in M.tb-unexposed controls and microbiologically confirmed pulmonary TB patients. In an independent cohort of healthy adolescents, levels of IFN-γ released in QFT and ESAT-6-free IGRA were highly correlated (P < .0001, r = 0.83) and yielded comparable positivity rates, 41.5% and 43.5%, respectively, with 91% concordance between the tests (kappa = 0.82; 95% confidence interval, 0.74-0.90; McNemar test P = .48). ESAT-6-free IGRA blood collection tubes had acceptable lot-to-lot variability, precision, and stability. CONCLUSIONS: The novel ESAT-6-free IGRA had diagnostic accuracy comparable to QFT and is suitable for use in clinical trials to assess efficacy of candidate TB vaccines to prevent established M.tb infection.


Assuntos
Testes de Liberação de Interferon-gama , Interferon gama/sangue , Kit de Reagentes para Diagnóstico , Tuberculose/diagnóstico , Adolescente , Antígenos de Bactérias/imunologia , Proteínas de Bactérias/imunologia , Criança , Estudos de Coortes , Feminino , Humanos , Masculino , Mycobacterium tuberculosis/imunologia , Curva ROC , Reprodutibilidade dos Testes , Tuberculose/sangue , Tuberculose/imunologia , Vacinas contra a Tuberculose/administração & dosagem , Vacinas contra a Tuberculose/imunologia
2.
Bioanalysis ; 14(15): 1067-1079, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36125040

RESUMO

Background: Respiratory syncytial virus (RSV) vaccine is an unmet medical need. The virus reduction neutralization test (VRNT) was developed to replace the LI-COR microneutralization assay to measure RSV neutralization titers. Methods: A bridging study using selected V171 phase I samples and calibration studies using the WHO international standard antiserum to RSV were performed to compare VRNT and LI-COR. Results: From the bridging study, we showed good concordance between VRNT and LI-COR titers, and similar post-/prevaccination titer ratios. From the calibration studies, we can convert VRNT and LI-COR titers into similar IU/ml. Conclusion: The VRNT and LI-COR microneutralization assay correlate well and the titers can be standardized as similar IU/ml, enabling direct comparison of titers from different assays.


Assuntos
Vírus Sinciciais Respiratórios , Vacinas , Anticorpos Neutralizantes , Calibragem , Testes de Neutralização , Organização Mundial da Saúde
3.
J Immunol Methods ; 494: 113054, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33845088

RESUMO

Respiratory syncytial virus (RSV) is a common pathogen causing severe respiratory illness in infants and elder adults. The development of an effective RSV vaccine is an important unmet medical need and an area of active research. The traditional method for testing neutralizing antibodies against RSV in clinical trials is the plaque reduction neutralization test (PRNT), which uses 24-well plates and needs several days post infection to develop viral plaques. In this study, we have developed a virus reduction neutralization test (VRNT), which allows the number of RSV infected cells to be automatically counted by an imaging cytometer at one day post infection in 96-well plates. VRNT was found robust to cell seeding density, detection antibody concentration, virus input and infection time. By testing twenty human sera, we have shown good correlation between VRNT50 and PRNT50 titers for multiple RSV strains: A2, Long and 18537 (serotype B). To understand the VRNT performance, eight human serum samples with high, medium and low neutralization titers were selected for VRNT qualification. We have demonstrated that VRNT had good specificity, precision, linearity and relative accuracy. In conclusion, VRNT is a better alternative to PRNT in serum neutralization test for RSV vaccine candidates.


Assuntos
Testes de Neutralização/métodos , Infecções por Vírus Respiratório Sincicial/diagnóstico , Vacinas contra Vírus Sincicial Respiratório/imunologia , Vírus Sinciciais Respiratórios/fisiologia , Idoso de 80 Anos ou mais , Animais , Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , Chlorocebus aethiops , Diagnóstico por Imagem , Ensaios de Triagem em Larga Escala , Humanos , Lactente , Recém-Nascido , Miniaturização , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Fatores de Tempo , Células Vero , Ensaio de Placa Viral
4.
Am J Trop Med Hyg ; 99(6): 1430-1439, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30350775

RESUMO

Vaccine immunogenicity and clinical efficacy are often assessed by the measure of serum-neutralizing antibodies. The present gold standard for detecting neutralizing antibodies against many viruses, including dengue, is the plaque/focus reduction neutralization test (P/FRNT). The FRNT is a cell-based assay that inherits high variability, resulting in poor precision and has lengthy turnaround times. The virus reduction neutralization test (VRNT) is a high-throughput alternative to the standard low-throughput and laborious FRNT. The VRNT is similar to FRNT using unaltered wild-type virus and immunostaining, yet uses imaging cytometry to count virus-infected cells 1 day post-infection, reducing assay time and increasing overall throughput 15-fold. In addition, the VRNT has lowered variability relative to FRNT, which may be explained in part by the observation that foci overlap alters foci count and titer over time, in the FRNT. The ability to count one infected cell, rather than waiting for overlapping foci to form, ensures accuracy and contributes to the precision (7-25% coefficient of variation) and sensitivity of the VRNT. Results from 81 clinical samples tested in the VRNT and FRNT show a clear positive relationship. During sample testing, a 96-well plate edge effect was noted and the elimination of this edge effect was achieved by a simple plate seeding technique. The VRNT is an improvement to the current neutralization assays for its shortened assay time, increased precision and throughput, and an alternative to the P/FRNT.


Assuntos
Anticorpos Neutralizantes/análise , Anticorpos Antivirais/análise , Vírus da Dengue/imunologia , Ensaios de Triagem em Larga Escala/normas , Imagem Molecular/métodos , Testes de Neutralização/normas , Análise de Célula Única/métodos , Animais , Antraquinonas/química , Chlorocebus aethiops , Dengue/imunologia , Dengue/prevenção & controle , Dengue/virologia , Vacinas contra Dengue/análise , Vírus da Dengue/isolamento & purificação , Corantes Fluorescentes/química , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Células Vero , Carga Viral , Ensaio de Placa Viral
5.
Nat Commun ; 7: 11290, 2016 04 12.
Artigo em Inglês | MEDLINE | ID: mdl-27068708

RESUMO

Vaccines to protect against tuberculosis (TB) are urgently needed. We performed a case-control analysis to identify immune correlates of TB disease risk in Bacille Calmette-Guerin (BCG) immunized infants from the MVA85A efficacy trial. Among 53 TB case infants and 205 matched controls, the frequency of activated HLA-DR(+) CD4(+) T cells associates with increased TB disease risk (OR=1.828, 95% CI=1.25-2.68, P=0.002, FDR=0.04, conditional logistic regression). In an independent study of Mycobacterium tuberculosis-infected adolescents, activated HLA-DR(+) CD4(+) T cells also associate with increased TB disease risk (OR=1.387, 95% CI=1.068-1.801, P=0.014, conditional logistic regression). In infants, BCG-specific T cells secreting IFN-γ associate with reduced risk of TB (OR=0.502, 95% CI=0.29-0.86, P=0.013, FDR=0.14). The causes and impact of T-cell activation on disease risk should be considered when designing and testing TB vaccine candidates for these populations.


Assuntos
Vacina BCG/imunologia , Linfócitos T CD4-Positivos/imunologia , Ativação Linfocitária/imunologia , Vacinação , Adolescente , Formação de Anticorpos/imunologia , Estudos de Casos e Controles , Estudos de Coortes , Antígenos HLA-DR/imunologia , Humanos , Imunidade , Imunoglobulina G/imunologia , Lactente , Modelos Logísticos , Mycobacterium tuberculosis/imunologia , Placebos , Fatores de Risco , Fatores de Tempo , Tuberculose/sangue , Tuberculose/imunologia , Vacinas contra a Tuberculose/imunologia , Vacinas de DNA
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA