Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Intervalo de ano de publicação
1.
Clin Oral Investig ; 26(4): 3383-3393, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-35149906

RESUMO

OBJECTIVES: This systematic review investigated the hypothesis that preheated resin composites (RCs) used as luting agents improve the mechanical properties, physicochemical performance, and color of indirect ceramic restorations. MATERIALS AND METHODS: Literature search was performed in three databases (Medline/PubMed, Scopus, and Web of Science) and in the grey literature (OpenGrey, ProQuest, and Catalog of Theses & Dissertations from CAPES). Eligibility criteria included only studies comparing at least one preheated RC used as a luting agent with resin cements. RESULTS: Data regarding the mechanical properties, physicochemical characteristics, and color were analyzed qualitatively, and the microtensile bond strength and film thickness were also evaluated by meta-analysis. The search strategy identified 3894 papers, and 28 were full-text screened. Seven studies were included in the review, and 5 were included in the meta-analysis. No significant difference was found for microtensile bond strength (P = 0.14). Preheated RCs showed significantly higher film thickness than resin cements (P = 0.001). CONCLUSION: Overall, the use of preheated RCs as luting agents offers similar to poorer performance than using resin cements for bonding indirect restorations. CLINICAL RELEVANCE: Despite the claim that preheated RC could be used as a luting agent, further studies should investigate the effect of clinically unacceptable film thickness.


Assuntos
Colagem Dentária , Cimentos Dentários , Resinas Compostas/química , Cimentos Dentários/química , Teste de Materiais , Cimentos de Resina/química , Propriedades de Superfície
2.
Int J Oral Maxillofac Implants ; 38(5): 985-995, 2023 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-37847840

RESUMO

PURPOSE: To evaluate the peri-implant outcomes of customized healing abutments (CstHA) placed on dental implants inserted in fresh tooth extraction sockets. MATERIALS AND METHODS: The study was registered on PROSPERO: CRD42022304320. A systematic search in PubMed, Scopus, and Web of Science was conducted between April 2022 and October 2022 to identify clinical studies involving immediate implant surgery associated with CstHA placement. The Joanna Briggs Institute Critical Appraisal and RoB2 tool were performed for the risk of bias analysis. RESULTS: A total of 12 studies were included, most of them with low risk of bias. Four studies compared CstHA vs conventional healing abutments (CnvtHA), two compared CstHA vs cover screw and collagen matrix (CMa), and six were clinical case series. For the CstHA vs CnvtHA comparison, favorable results were observed for CstHA considering papilla maintenance and probing depth, yet the mean marginal bone level was statistically similar between CstHA and CnvtHA. CstHA showed advantages when compared to CMa for total bone volume, papilla height, and midfacial mucosa maintenance. Significantly less horizonal bone loss was reported when using CstHA compared with CMa. Horizontal and vertical bone loss was observed in a few (or no) sites in the case series using CstHA. CONCLUSIONS: CstHA provides favorable peri-implant response because in general it does not result in a significant loss of soft and hard tissues.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Carga Imediata em Implante Dentário , Humanos , Carga Imediata em Implante Dentário/métodos , Implantação Dentária Endóssea/métodos , Alvéolo Dental/cirurgia , Extração Dentária/métodos , Dente Suporte
3.
Dent Mater ; 39(4): 410-417, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36914433

RESUMO

OBJECTIVES: To evaluate the influence of printing orientation on color and translucency of 3D printing restorative resins. METHODS: Four 3D printing resin systems in the available shades (DFT-Detax Freeprint Temp- A1, A2,A3; FP-Formlabs Permanent Crown- A2,A3,B1,C2; FT- Formlabs Temporary CB- A2,A3,B1,C2; GCT-GC Temporary- Light, Medium) were evaluated. Three samples (10×10×1.2 mm) from each material were printed at two different printing orientations (0° and 90°) and polished to 1.00 ± 0,01 mm of thickness. Spectral reflectance was measured against black background using a calibrated spectroradiometer, CIE D65 standard illuminant and the 45°/0°geometry. Color and translucency differences were evaluated using CIEDE2000 metric (ΔE00) and 50:50% perceptibility (PT00 and TPT00) and acceptability (AT00 and TAT00) thresholds. RESULTS: In general, color changes due to printing orientation at (0° and 90°) were mainly produced by ΔL* or ΔC* . ΔE00 were above PT00 for all DFT shades, FP-B1, FP-C2, FT-A2 and FT-B1. Only for DFT-1, ΔE00 was above AT00. ΔRTP00 values were above TPT00 for DFT-A1, DFT-A3, FP-B1 and FT-B1, but lower than TAT00. The direction of the changes in translucency (ΔRTP00) depends on the material and shade. SIGNIFICANCE: The selection of building orientation (0° and 90°) for the 3D printed resins influence the visual color and translucency and therefore their esthetic appearance. These aspects should be considered when printing dental restorations using the evaluated materials.


Assuntos
Coroas , Porcelana Dentária , Impressão Tridimensional , Resinas Compostas , Teste de Materiais , Cor
4.
J Adhes Dent ; 14(2): 155-60, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22282756

RESUMO

PURPOSE: To evaluate the effect of cement shade, light-curing unit, and water storage on tensile bond strength (σ) of a feldspathic ceramic resin bonded to dentin. MATERIALS AND METHODS: The dentin surface of 40 molars was exposed and etched with 37% phosphoric acid, then an adhesive system was applied. Forty blocks of feldspathic ceramic (Vita VM7) were produced. The ceramic surface was etched with 10% hydrofluoric acid for 60 s, followed by the application of a silane agent and a dual-curing resin cement (Variolink II). Ceramic blocks were cemented to the treated dentin using either A3 or transparent (Tr) shade cement that was activated using either halogen or LED light for 40 s. All blocks were stored in 37°C distilled water for 24 h before cutting to obtain non-trimmed bar-shaped specimens (adhesive area = 1 mm2 ± 0.1) for the microtensile bond strength test. The specimens were randomly grouped according to the storage time: no storage or stored for 150 days in 37°C distilled water. Eight experimental groups were obtained (n = 30). The specimens were submitted to the tensile bond strength test using a universal testing machine at a crosshead speed of 1 mm/min. The data were statistically analyzed using ANOVA and Tukey's posthoc tests (a = 0.05). RESULTS: The mean bond strength values were significantly lower for the corresponding water stored groups, except for the specimens using A3 resin cement activated by halogen light. There was no significance difference in mean bond strength values among all groups after water storage. CONCLUSION: Water storage had a detrimental effect under most experimental conditions. For both cement shades investigated (Tr and A3) under the same storage condition, the light-curing units (QTH and LED) did not affect the mean microtensile bond strengths of resin-cemented ceramic to dentin.


Assuntos
Cor , Lâmpadas de Polimerização Dentária , Colagem Dentária , Porcelana Dentária , Adesivos Dentinários , Análise de Variância , Cerâmica , Análise do Estresse Dentário , Dentina , Adesivos Dentinários/efeitos da radiação , Humanos , Cimentos de Resina/efeitos da radiação , Estatísticas não Paramétricas , Resistência à Tração , Água
5.
Braz Dent J ; 30(4): 380-384, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31340229

RESUMO

This study evaluated the fracture load (Lf) and the failure mode of CAD-on (Ivoclar Vivadent) ceramic structures, testing the hypotheses that Lf of multilayer structures is governed by the veneering ceramic strength and that chipping is more frequent in multilayer than monolithic structures. Disc-shaped specimens were fabricated as follows: CAD-on- trilayer structure composed of Y-TZP (yttria stabilized tetragonal zirconia polycrystal- IPS e.max ZirCAD) infrastructure, fusion glass-ceramic (IPS e.max CAD Crystall/Connect) and lithium disilicate-based glass-ceramic (IPS e.max CAD); YLD- bilayer structure composed of Y-TZP infrastructure and fluorapatite layering ceramic (IPS e.max Ceram); LDC- monolithic lithium-disilicate glass-ceramic (IPS e.max CAD); and YZW- monolithic Y-TZP (Zenostar Zr Translucent). The specimens were loaded in compression until failure and fracture surfaces were evaluated using fractographic principles. Lf values were statistically analyzed using the Weibull statistics, Kruskal-Wallis and Dunn tests (a= 0.05). YZW (1329 N) and CAD-on (1085 N) showed the greatest Lf median values, followed by YLD (832 N) and LDC (421 N). All monolithic structures (LDC and YZW) fractured catastrophically and all YLD structures failed by chipping. The CAD-on technique seems to be a very promising fabrication process because it showed high Lf, similar to monolithic zirconia, and small chipping rate.


Assuntos
Desenho Assistido por Computador , Porcelana Dentária , Cerâmica , Teste de Materiais , Zircônio
6.
Dent Mater ; 35(2): 292-297, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30527588

RESUMO

OBJECTIVE: To determine the visual whiteness thresholds for esthetic dentistry using the whiteness index for dentistry based on CIELAB color space (WID). METHODS: A total of 60 observers (Dentists and Laypersons; n=30) from three research sites participated in the study. A psychophysical experiment based on visual assessments of simulated images of teeth on a calibrated display was performed. Images of simulated upper central incisors (SUCI) were consecutively displayed in pairs (60) and the whiteness of each SUCI pair was compared. WID was used to calculate the visual thresholds (WPT- perceptibility threshold; and WAT- acceptability threshold) with 95% confidence intervals (CI) and a Takagi-Sugeno-Kang (TSK) Fuzzy Approximation model was used as fitting procedure. Data was statistical analyzed using paired t-test (α=0.05). RESULTS: WPT and WAT were 0.72 (CI: 0.0-2.69; r2=0.52) and 2.62 (CI: 0.2-7+; r2=0.57) WID units, respectively. Significant differences (p<0.05) were found between WPT and WAT, and between dentist (WPT=0.46WID units; WAT=2.20 WID units) and layperson (WPT=0.94 WID units; WAT=2.95 WID units). SIGNIFICANCE: The visual whiteness difference thresholds determined with WID index can serve as reference values for research and manufacturing of dental materials, and for clinical practice situations such as assessing the effectiveness of bleaching treatments.


Assuntos
Percepção de Cores , Odontologia , Cor , Materiais Dentários , Incisivo
7.
Oper Dent ; 33(2): 121-6, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18435184

RESUMO

This study evaluated the validity and reliability of the visual assessment of tooth color using a commercial shade guide. Ninety-two individuals were randomly selected from subjects enrolled in a randomized controlled trial comparing two formulations of carbamide peroxide. Initially, each individual had the color of his or her six maxillary anterior teeth (n=552) determined by one examiner using a digital spectrophotometer (Vita Easyshade). Then, a visual assessment was made by two calibrated examiners using a shade guide (Vitapan Classical). Reliability was evaluated either by kappa coefficient when all the colors were grouped into two categories (dark and light) or by weighted kappa when all 16 colors of the shade guide were considered. The digital spectrophotometer (Vita Easyshade) was used as the gold standard to calculate sensitivity and specificity of the visual assessment. The reliability of the visual assessment using two color categories was "substantial" (k=0.69). When all colors of the shade guide were considered, the reliability was "mild" (kw=0.33). Sensitivity and specificity of the visual assessment with respect to the gold standard was 86.9% and 81.9%, respectively. Despite its subjectivity, visual assessment of tooth color using the Vitapan Classical shade guide is a valid method, with good reliability for differentiating between dark and light colors.


Assuntos
Percepção de Cores/fisiologia , Clareamento Dental/métodos , Dente/anatomia & histologia , Adolescente , Adulto , Peróxido de Carbamida , Cor , Dente Canino/anatomia & histologia , Combinação de Medicamentos , Feminino , Humanos , Incisivo/anatomia & histologia , Masculino , Pessoa de Meia-Idade , Oxidantes/administração & dosagem , Oxidantes/uso terapêutico , Peróxidos/administração & dosagem , Peróxidos/uso terapêutico , Sensibilidade e Especificidade , Espectrofotometria , Descoloração de Dente/tratamento farmacológico , Ureia/administração & dosagem , Ureia/análogos & derivados , Ureia/uso terapêutico
8.
J Adhes Dent ; 8(3): 175-81, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16830664

RESUMO

PURPOSE: The aim of this study was to evaluate the effect of two surface conditioning methods on the microtensile bond strength of a resin cement to three high-strength core ceramics: high alumina-based (In-Ceram Alumina, Procera AllCeram) and zirconia-reinforced alumina-based (In-Ceram Zirconia) ceramics. MATERIALS AND METHODS: Ten blocks (5 x 6 x 8 mm) of In-Ceram Alumina (AL), In-Ceram Zirconia (ZR), and Procera (PR) ceramics were fabricated according to each manufacturer's instructions and duplicated in composite. The specimens were assigned to one of the two following treatment conditions: (1) airborne particle abrasion with 110-microm Al2O3 particles + silanization, (2) silica coating with 30 microm SiOx particles (CoJet, 3M ESPE) + silanization. Each ceramic block was duplicated in composite resin (W3D-Master, Wilcos, Petrópolis, RJ, Brazil) using a mold made out of silicon impression material. Composite resin layers were incrementally condensed into the mold to fill up the mold and each layer was light polymerized for 40 s. The composite blocks were bonded to the surface-conditioned ceramic blocks using a resin cement system (Panavia F, Kuraray, Okayama, Japan). One composite resin block was fabricated for each ceramic block. The ceramic-composite was stored at 37 degrees C in distilled water for 7 days prior to bond tests. The blocks were cut under water cooling to produce bar specimens (n = 30) with a bonding area of approximately 0.6 mm2. The bond strength tests were performed in a universal testing machine (crosshead speed: 1 mm/min). Bond strength values were statistically analyzed using two-way ANOVA and Tukey's test (< or = 0.05). RESULTS: Silica coating with silanization increased the bond strength significantly for all three high-strength ceramics (18.5 to 31.2 MPa) compared to that of airborne particle abrasion with 110-microm Al2O3 (12.7-17.3 MPa) (ANOVA, p < 0.05). PR exhibited the lowest bond strengths after both Al2O3 and silica coating (12.7 and 18.5 MPa, respectively). CONCLUSION: Conditioning the high-strength ceramic surfaces with silica coating and silanization provided higher bond strengths of the resin cement than with airborne particle abrasion with 110-microm Al2O3 and silanization.


Assuntos
Óxido de Alumínio/química , Cerâmica/química , Colagem Dentária , Porcelana Dentária/química , Cimentos de Resina/química , Zircônio/química , Abrasão Dental por Ar , Resinas Compostas/química , Análise do Estresse Dentário/instrumentação , Humanos , Teste de Materiais , Silanos/química , Dióxido de Silício/química , Estresse Mecânico , Propriedades de Superfície , Temperatura , Resistência à Tração , Água/química
9.
Materials (Basel) ; 8(8): 4978-4991, 2015 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-28793485

RESUMO

Ceramics are very important in the science of dental biomaterials. Among all dental ceramics, zirconia is in evidence as a dental biomaterial and it is the material of choice in contemporary restorative dentistry. Zirconia has been applied as structural material for dental bridges, crowns, inserts, and implants, mostly because of its biocompatibility, high fracture toughness, and radiopacity. However, the clinical success of restorative dentistry has to consider the adhesion to different substrates, which has offered a great challenge to dental zirconia research and development. This study characterizes zirconia as a dental biomaterial, presenting the current consensus and challenges to its dental applications.

10.
Braz Dent J ; 26(3): 228-33, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26200145

RESUMO

This study aimed to evaluate histologically the effect of irrigation with 400 ppm Sterilox, 2% and 5% sodium hypochlorite (NaOCl), with and without photo-activated therapy (PAD), in a single-visit root canal treatment of dog's teeth with apical periodontitis (AP). Ten dogs were randomly divided into two groups (n=5): with and without PAD, and the root canals into four subgroups, according to the irrigating solution: SX (400 ppm Sterilox), SH2 (2% NaOCl), SH5 (5% NaOCl) and SS (saline solution) as positive control. A total of 134 root canals were opened and left exposed to the oral environment for 14 days and then sealed for 60 days for AP induction. Then, root canals were treated according to each proposed disinfecting protocol and filled in the same session. After 120 days, the dogs were euthanized and the periapical inflammatory events were evaluated under light microscopy. Qualitative data were submitted to Kruskal-Wallis and Mann-Whitney tests (α=0.05). PAD did not produce significant differences in the scores for apical inflammation when used after chemo-mechanical preparation (p>0.05). The irrigating solutions SX, SH2 and SH5 without PAD were statistically different from SS (p<0.05) that presented the greatest scores for apical inflammation. PAD did not show any additional effect for the treatment of root canals with pulp necrosis and AP in a single visit and 400 ppm Sterilox may be considered an alternative to NaOCl in root canal treatment.


Assuntos
Peróxido de Hidrogênio , Fototerapia , Irrigantes do Canal Radicular , Tratamento do Canal Radicular , Hipoclorito de Sódio , Animais , Cães
11.
Dent Mater ; 19(7): 662-9, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-12901992

RESUMO

OBJECTIVE: To test the hypothesis that the Weibull moduli of single- and multilayer ceramics are controlled primarily by the structural reliability of the core ceramic.Methods. Seven groups of 20 bar specimens (25 x 4 x 1.2 mm) were made from the following materials: (1) IPS Empress--a hot-pressed (HP) leucite-based core ceramic; (2) IPS Empress2--a HP lithia-based core ceramic; (3 and 7) Evision--a HP lithia-based core ceramic (ES); (4) IPS Empress2 body--a glass veneer; (5) ES (1.1 mm thick) plus a glaze layer (0.1 mm); and (6) ES (0.8 mm thick) plus veneer (0.3 mm) and glaze (0.1 mm). Each specimen was subjected to four-point flexure loading at a cross-head speed of 0.5 mm/min while immersed in distilled water at 37 degrees C, except for Group 7 that was tested in a dry environment. Failure loads were recorded and the fracture surfaces were examined using SEM. ANOVA and Duncan's multiple range test were used for statistical analysis. RESULTS: No significant differences were found between the mean flexural strength values of Groups 2, 3, 5, and 6 or between Groups 1 and 4 (p>0.05). However, significant differences were found for dry (Group 7) and wet (Groups 1-6) conditions. Glazing had no significant effect on the flexural strength or Weibull modulus. The strength and Weibull modulus of the ES ceramic were similar to those of Groups 5 and 6. SIGNIFICANCE: The structural reliability of veneered core ceramic is controlled primarily by that of the core ceramic.


Assuntos
Coroas , Porcelana Dentária , Facetas Dentárias , Silicatos de Alumínio , Análise de Variância , Análise do Estresse Dentário , Elasticidade , Compostos de Lítio , Teste de Materiais , Maleabilidade , Análise de Regressão , Estatísticas não Paramétricas , Propriedades de Superfície , Análise de Sobrevida , Molhabilidade
12.
J Dent ; 42(2): 114-21, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24316342

RESUMO

OBJECTIVES: This study aimed to assess changes in oral health-related quality of life (OHRQoL) in individuals enroled in a double-blind randomized clinical trial conducted to evaluate the efficacy and safety of two carbamide peroxide concentrations used in at-home vital bleaching in the city of Pelotas, Southern Brazil. METHODS: Ninety-two volunteers with a shade mean of C1 or darker for the six maxillary anterior teeth were randomized into two balanced groups (n=46) according to bleaching agent concentration: 10% or 16% carbamide peroxide. The patients were instructed to use the whitening agent in a tray for 2h once a day for three weeks. To assess changes in OHRQoL, participants completed the oral impact on daily performance (OIDP) at the start and one week after the completion of treatment. Because there was no difference with regard to whitening effect or tooth sensitivity during or after treatment the two groups were merged for the analyses of the current article. Before-and-after changes in OIDP scores were assessed by chi-square and McNemar tests (p<0.05). RESULTS: Mean pre- and post-treatment OIDP scores varied from 0.42 to 0.60. When the frequency of impacts for different activities were compared, there was an increase in difficulty in cleaning teeth (p=0.02) and a significant reduction in smiling and showing teeth with embarrassment (p=0.03). Regarding the symptoms and main oral conditions that generated impact, there was higher number of participants reporting pain (p=0.05) after treatment. In opposite, significant decrease was observed in individuals reporting being unhappy with their appearance (p=0.03). On the contrary, it was showed a decrease in impacts resulting from dental colour was observed after bleaching (p=0.03). CONCLUSION: Quality of life is complex and encompasses different domains. Although positive impact of the dental bleaching was detected, with patients showing more their teeth without embarrassment, difficult in dental hygiene and pain resulting from the treatment were also reported, and this can negatively impact daily performances. Dentists must consider these aspects when performing aesthetics procedures.


Assuntos
Saúde Bucal , Qualidade de Vida , Clareamento Dental/psicologia , Atividades Cotidianas , Adolescente , Adulto , Atitude Frente a Saúde , Peróxido de Carbamida , Sensibilidade da Dentina/etiologia , Sensibilidade da Dentina/psicologia , Método Duplo-Cego , Escolaridade , Estética Dentária , Feminino , Seguimentos , Nível de Saúde , Humanos , Renda , Masculino , Higiene Bucal/psicologia , Peróxidos/administração & dosagem , Segurança , Sorriso/psicologia , Clareadores Dentários/administração & dosagem , Descoloração de Dente/tratamento farmacológico , Descoloração de Dente/psicologia , Resultado do Tratamento , Ureia/administração & dosagem , Ureia/análogos & derivados , Adulto Jovem
13.
Braz Oral Res ; 27(5): 396-402, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24036977

RESUMO

The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm). OA had the highest median gap dimension (125 µm), followed by the AOT point (105 µm). CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.


Assuntos
Cerâmica/química , Adaptação Marginal Dentária , Planejamento de Dentadura/métodos , Prótese Parcial Fixa , Zircônio/química , Desenho Assistido por Computador , Humanos , Teste de Materiais , Odontometria , Valores de Referência , Reprodutibilidade dos Testes , Estatísticas não Paramétricas , Microtomografia por Raio-X/métodos
14.
J Dent ; 41 Suppl 3: e93-6, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23123496

RESUMO

OBJECTIVES: One of the goals of endodontic treatment is the adequate filling of the root canal,which is often done using gutta-percha and sealer. It has been reported that sealer remnants in the coronary pulp chamber cause tooth color changes. Therefore, this study was designed to examine the effect of endodontic sealer remnants on tooth color, testing the hypothesis that sealers cause coronal color changes. METHODS: Forty single-rooted human teeth were endodontically treated leaving excess sealer material in the coronary pulp chamber. The specimens were divided into four groups (n = 10) according to the endodontic sealer used (AH, AH Plus; EF, Endofill; EN,endome´ thasoneN; and S26, Sealer 26). Teeth were stored at 37 8C moist environment.Color coordinates (L*a*b*) were measured with a spectrophotometer before endodontic treatment(baseline-control), 24 h and 6 months after treatment. L*a*b* values were used to calculate color changes (DE). Data were statistically analyzed using Kruskal­Wallis and Mann­Whitney-U tests. RESULTS: Color changes were observed for all groups with S26 and EN producing the greatest mean DE values after 6 months. CONCLUSION: Endodontic sealer remnants affect tooth color confirming the experimental hypothesis. CLINICAL SIGNIFICANCE: This study examined the effect of endodontic sealer remnants on tooth color, and observed that after 6 months, the sealers produced unacceptable color changes.


Assuntos
Materiais Restauradores do Canal Radicular/efeitos adversos , Descoloração de Dente/induzido quimicamente , Dente/efeitos dos fármacos , Bismuto/efeitos adversos , Hidróxido de Cálcio/efeitos adversos , Cor , Dexametasona/efeitos adversos , Combinação de Medicamentos , Resinas Epóxi/efeitos adversos , Formaldeído/efeitos adversos , Humanos , Umidade , Hidrocortisona/efeitos adversos , Teste de Materiais , Espectrofotometria/métodos , Temperatura , Timol/efeitos adversos , Timol/análogos & derivados , Fatores de Tempo , Dente/patologia , Dente não Vital/patologia
15.
Braz Dent J ; 23(5): 471-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23306220

RESUMO

This study evaluated the use de standards in papers published in Brazilian and international dental journals. Papers published from January 2006 to December 2010 in the following journals were examined: Brazilian Dental Journal (BDJ), Brazilian Oral Research (BOR), Journal of Applied Oral Sciences (JAOS), Journal of Dental Research (JDR) and Dental Materials (DM). In addition to the title and type of study, issue, volume and year of publication, the following information was recorded from each paper: identification of any standard reported in the study; in case of no reported standard, indication if a standard could be used in the study. A total of 3,046 papers were examined, being 937 from DM, 936 from JDR, 489 from JAOS, 348 from BDJ, and 336 from BOR. Considering the papers that could use some standard, DM showed the highest percentage (24.9%) of reporting standards/paper, followed by JAOS (10.3%), BOR (10.1%), BDJ (6.3%) and JDR (2.4%), meaning for example that, from 936 papers examined from the JDR, 623 could use some standard but only 15 papers reported them. From all papers examined, 309 (10.1%) reported using some standard. The ISO standards were mostly reported (57.8%), followed by ASTM standards (23.7%) and 74 (18.5%) standards from other international organizations (e.g. ADA and CIE). Despite of the high impact factors of the selected dental journals, their published papers could use standards more often. This study should assist journal editors to encourage authors to consult and refer to available standards to support the scientific papers.


Assuntos
Bibliometria , Pesquisa em Odontologia/normas , Publicações Periódicas como Assunto/normas , Fator de Impacto de Revistas
16.
Dent Mater ; 28(1): 41-51, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22192250

RESUMO

OBJECTIVES: This paper attempts to provide critical perspectives on common in vitro research methodologies, including shear bond testing, wear testing, and load-to-failure tests. Origins of interest in high-quality laboratory data is reviewed, in vitro data is categorized into property and simulation protocols, and two approaches are suggested for establishing clinical validity. It is hoped that these insights will encourage further progress toward development of in vitro tests that are validated against clinical performance and/or by producing clinically validated failure or damage mechanisms. MATERIALS AND METHODS: Published shear and tensile bond data (macro and micro) is examined in light of published finite element analyses (FEA). This data is subjected to a Weibull scaling analysis to ascertain whether scaling is consistent with failure from the bonded interface or not. Wear tests results are presented in light of the damage mechanism(s) operating. Quantitative wear data is re-examined as being dependent upon contact pressure. Load-to-failure test results are re-analyzed by calculating contact stresses at failure for 119 tests from 54 publications over more than 25 years. RESULTS: FEA analyses and reported failure modes (adhesive, mixed, cohesive) are consistent with failure not involving interfacial "shear stresses" as calculated in published work. Weibull scaling clearly suggests failure involving external surfaces of specimens, not interfacial origins. Contact stresses (pressures) are clearly an important variable in wear testing and are not well-controlled in published work. Load-to-failure tests create damage not seen clinically due to excessively high contact stresses. Most contact stresses in the 119 tests examined were calculated to be between 1000MPa and 5000MPa, whereas clinical contact stresses at wear facets have been measured not to exceed 40MPa. CONCLUSIONS: Our community can do a much better job of designing in vitro tests that more closely simulate clinical conditions, especially when contact is involved. Journals are encouraged to thoughtfully consider a ban on publishing papers using bond tests and load-to-failure methods that are seriously flawed and have no clinical relevance.


Assuntos
Colagem Dentária , Materiais Dentários , Análise do Estresse Dentário/métodos , Teste de Materiais/métodos , Força Compressiva , Desgaste de Restauração Dentária , Análise de Elementos Finitos , Padrões de Referência , Reprodutibilidade dos Testes , Resistência ao Cisalhamento , Análise de Sobrevida , Resistência à Tração
17.
RFO UPF ; 22(1): 76-81, 28/08/2017.
Artigo em Português | LILACS | ID: biblio-848724

RESUMO

Avaliar, in vitro, a variação de cor e dureza de três materiais restauradores (3M ESPE): Ketac Molar Easymix (KME); Vitremer (VT) e resina composta Filtek Z250 (Z250) após o clareamento com peróxido de carbamida a 37% (PC37- Whiteness Super) e peróxido de hidrogênio a 35% (PH35- Whiteness HP Maxx). Materiais e método: foram confeccionados 108 corpos de prova (CP), sendo 36 para cada material, avaliados inicialmente (baseline) e após cada aplicação dos agentes clareadores realizadas em subseqüentes 7 períodos, ou seja, após 1, 7, 14, 21, 28, 35 e 42 dias. As avaliações colorimétricas (coordenadas CIELAB) dos CP foram realizadas usando um espectrofotômetro (Easyshade, Vita Zahnfabrik, Bad Sackingen, Alemanha) sob fundo branco e em ambiente clínico. Para a avaliação da dureza (H), usou-se um durômetro (Pantec HVS 10, Panambra Ind. e Téc. SA, São Paulo, SP Brasil) com penetrador tipo Vickers. Os resultados das diferenças de cor (∆E*ab), diferenças de L* (∆L*) e H foram calculados e avaliados estatisticamente usando análise de variância (ANOVA) e as diferenças avaliadas pelo teste Tukey (α=0,05). Resultados: após o clareamento, houve alterações significativas no valor de ∆E*ab para os dois materiais a base de ionômero de vidro (KME e VT), com ambos os clareadores (PC37 e PH35) mostrando efeito similar para cada material. Não houve diferença na H dos materiais. Conclusão: após 42 dias, agentes clareadores alteraram a cor dos materiais ionoméricos e não alteraram a dureza dos materiais testados.

19.
Dent Mater ; 27(9): 948-53, 2011 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-21705061

RESUMO

OBJECTIVES: To determine the effect of porcelain thickness and the application of a surface liner (SL) on the flexural strength (σ) of a ceramic system. METHODS: One hundred twenty bar-shaped specimens of yttria-stabilized zirconia-based ceramic were fabricated and randomly divided into two groups according to the application of SL: A - applied; B - not applied. The specimens were further divided according to the porcelain veneer thickness (n=20): 0-0.5mm; 1-1.0mm; 2-2.0mm. All specimens were tested in 3-point bending with the porcelain under tension. The maximum load was recorded at first sign of fracture, the σ was calculated and the mode of failure was determined. Data was statistically analyzed using one-way ANOVA, Tukey (α=0.05) and Weibull distribution. RESULTS: The SL application had no effect (p=0.723) while the porcelain thickness had a significant effect (p=0.000) on the mean σ values. No significant differences in mean σ values were found with same porcelain thickness. A 0.5-mm thick porcelain layer (groups A0 and B0) showed greater mean σ values than other groups. The Weibull modulus (m) ranged from 6 (groups A1 and B2) to 9 (groups A0, A2 and B0). The predominant mode of failure for all groups was fracture initiation at the porcelain surface propagating to the ceramic interface. SIGNIFICANCE: The porcelain thickness influenced the mean σ values, but the SL had no significant effect on the flexural strength and the mode of failure of the ceramic system examined.


Assuntos
Porcelana Dentária , Planejamento de Prótese Dentária , Falha de Restauração Dentária , Análise de Variância , Análise do Estresse Dentário , Facetas Dentárias , Teste de Materiais , Maleabilidade , Propriedades de Superfície , Análise de Sobrevida , Resistência à Tração , Zircônio
20.
Braz Dent J ; 22(1): 45-50, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21519648

RESUMO

The aim of this study was to examine the effect of different acid etching times on the surface roughness and flexural strength of a lithium disilicate-based glass ceramic. Ceramic bar-shaped specimens (16 mm x 2 mm x 2 mm) were produced from ceramic blocks. All specimens were polished and sonically cleaned in distilled water. Specimens were randomly divided into 5 groups (n=15). Group A (control) no treatment. Groups B-E were etched with 4.9% hydrofluoric acid (HF) for 4 different etching periods: 20 s, 60 s, 90 s and 180 s, respectively. Etched surfaces were observed under scanning electron microscopy. Surface profilometry was used to examine the roughness of the etched ceramic surfaces, and the specimens were loaded to failure using a 3-point bending test to determine the flexural strength. Data were analyzed using one-way ANOVA and Tukey's test (?=0.05). All etching periods produced significantly rougher surfaces than the control group (p<0.05). Roughness values increased with the increase of the etching time. The mean flexural strength values were (MPa): A=417 ± 55; B=367 ± 68; C=363 ± 84; D=329 ± 70; and E=314 ± 62. HF etching significantly reduced the mean flexural strength as the etching time increased (p=0.003). In conclusion, the findings of this study showed that the increase of HF etching time affected the surface roughness and the flexural strength of a lithium disilicate-based glass ceramic, confirming the study hypothesis.


Assuntos
Condicionamento Ácido do Dente/métodos , Colagem Dentária , Porcelana Dentária , Análise do Estresse Dentário , Ácido Fluorídrico/química , Teste de Materiais , Microscopia Eletrônica de Varredura , Maleabilidade , Distribuição Aleatória , Propriedades de Superfície , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA