Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 31
Filtrar
1.
Am J Emerg Med ; 70: 144-150, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37290251

RESUMO

OBJECTIVE: The study aimed to assess the diagnostic accuracy of point-of-care ultrasound (POCUS) in identifying small bowel obstruction (SBO) and to investigate the impact of clinician experience level and body mass index (BMI) on POCUS performance for diagnosing SBO in the Emergency Department. METHODS: We systematically searched PubMed and Cochrane databases from January 2011-2022. We performed a meta-analysis using individual patient-level data from prospective diagnostic accuracy studies from which we obtained data from the corresponding authors. Overall test characteristics and subgroup analysis across clinician experience levels and a range of BMI were calculated. The primary outcome was SBO as the final diagnosis during hospitalization. RESULTS: We included Individual patient data from 433 patients from 5 prospective studies. Overall, 33% of patients had a final diagnosis of SBO. POCUS had 83.0% (95%CI 71.7%-90.4%) sensitivity and 93.0% (95%CI 55.3%-99.3%) specificity; LR+ was 11.9 (95%CI 1.2-114.9) and LR- was 0.2 (95%CI 0.1-0.3). Residents had exhibited a sensitivity of 73.0% (95%CI 56.6%-84.9%) and specificity of 88.2% (95%CI 58.8%-97.5%), whereas attendings had demonstrated a sensitivity of 87.7% (95%CI 71.1%-95.4%) and specificity of 91.4% (95%CI 57.4%-98.8%). Among those patients with BMI<30 kg/m2, POCUS showed a sensitivity of 88.6% (95%CI 79.5%-94.7%) and a specificity of 84.0% (95%CI 75.3%-90.6%), while patients with BMI ≥ 30 kg/m2 exhibited a sensitivity of 72.0% (95%CI 50.6%-87.9%) and specificity of 89.5% (95%CI 75.2%-97.1%). CONCLUSIONS: POCUS correctly identified those patients with SBO with high sensitivity and specificity. Diagnostic accuracy was slightly reduced when performed by resident physicians and among patients with a BMI ≥ 30 kg/m2. REGISTRATION: PROSPERO registration number: CRD42022303598.


Assuntos
Obstrução Intestinal , Sistemas Automatizados de Assistência Junto ao Leito , Humanos , Estudos Prospectivos , Ultrassonografia , Testes Imediatos , Obstrução Intestinal/diagnóstico por imagem , Serviço Hospitalar de Emergência , Sensibilidade e Especificidade , Estudos Multicêntricos como Assunto
2.
Ann Emerg Med ; 75(2): 246-256, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31350094

RESUMO

STUDY OBJECTIVE: We evaluate the accuracy of point-of-care ultrasonography compared with computed tomographic (CT) scan and assess the potential time-saving effect of point-of-care ultrasonography in diagnosing small bowel obstruction. METHODS: This was a prospective observational study of a convenience sample of patients with suspected small bowel obstruction in an academic emergency department (ED). Physician sonographers were blinded to clinical data, laboratory results, and CT scan findings. Point-of-care ultrasonographic findings of small bowel obstruction was the primary outcome, defined as bowel-loop diameter greater than or equal to 25 mm with abnormal peristalsis. Maximum bowel dilatation, visible peristalsis, interluminal free fluid, and bowel wall thickness were evaluated. Time to completion of imaging results was abstracted from the medical records for each imaging modality. RESULTS: The study included 125 patients (median age 54.0 years [interquartile range 43 to 63 years]; 46% men), of whom 32 (25.6%) had small bowel obstruction, and 9 (7.2%) underwent surgery for it. Overall, the sensitivity of point-of-care ultrasonography for small bowel obstruction was 87.5% (95% confidence interval 71.0% to 96.5%), and specificity was 75.3% (95% confidence interval 65.2% to 83.6%). The area under the receiver operating characteristic curve to accurately predict small bowel obstruction was 0.74 (95% confidence interval 0.66 to 0.82). Results were similar across evaluated subgroups, including physician training level. The average time to obtain a CT scan report was 3 hours, 42 minutes; obtaining an abdominal radiograph took 1 hour, 38 minutes; and the mean elapsed time to complete point-of-care ultrasonography was 11 minutes. CONCLUSION: In ED patients with suspected small bowel obstruction, point-of-care ultrasonography has a reasonably high accuracy in diagnosing small bowel obstruction compared with CT scan, and may substantially decrease the time to diagnosis.


Assuntos
Obstrução Intestinal/diagnóstico por imagem , Intestino Delgado/diagnóstico por imagem , Sistemas Automatizados de Assistência Junto ao Leito , Tomografia Computadorizada por Raios X , Ultrassonografia , Adulto , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Radiografia , Sensibilidade e Especificidade , Fatores de Tempo
3.
Am J Emerg Med ; 38(11): 2356-2360, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-31864865

RESUMO

OBJECTIVE: Early diagnostic prediction in patients with small bowel obstruction (SBO) can improve time to definitive management and disposition in the emergency department. We sought to develop a nomogram to leverage point-of-care ultrasound (POCUS) and maximize accuracy of prediction of SBO diagnosis. METHODS: Using data from a prospective cohort of 125 patients with suspected SBO who were evaluated with POCUS in the ED, we developed a nomogram integrating age, gender, comorbidities, prior abdominal surgery, physician's pre-test probability, and POCUS findings to determine post-test risk of SBO. The primary outcome was to develop a nomogram to allow calculating output probabilities for predictive models using POCUS findings. The discriminative ability of the nomogram was tested using a C-statistics, calibration plots, and receiver operating characteristic curves. RESULTS: The derivation cohort included 125 patients with a median age of 54 years who underwent POCUS for a suspected SBO. One-fourth of the patients (25.6% [32/125]) had SBO. Using a retrospective stepwise selection of clinically important variables with the POCUS results, the final nomogram incorporated four relevant factors for the prediction of SBO: small bowel diameter (odds ratio [OR] per 1 mm increase, 1.10; 95% CI, 1.03-1.17; P = 0.001), positive free intraperitoneal fluid between bowel loops (OR, 8.19; 95% CI, 2.62-25.62; P < 0.001), clinician's moderate (OR, 5.94; 95% CI, 0.83-42.57; P = 0.08) or high pretest probability (OR, 11.26; 95% CI, 1.44-88.25; P = 0.02), and patient age (OR per 1 year increase, 1.03; 95% CI, 1.00 to1.07; P = 0.08).The discriminative ability and calibration of the nomogram revealed good predictive ability as indicated by the C-statistic of 0.89 for the SBO diagnosis. CONCLUSION: A unique nomogram incorporating patient age, physician pretest probability of SBO, and POCUS measurements of small bowel diameter and the presence of free intraperitoneal fluid between bowel loops was developed to accurately predict the diagnosis of SBO in the emergency department. The nomogram should be externally validated in a novel cohort of patients at risk for SBO to better assess predictability and generalizability.


Assuntos
Obstrução Intestinal/diagnóstico , Intestino Delgado/diagnóstico por imagem , Nomogramas , Serviço Hospitalar de Emergência , Feminino , Humanos , Intestino Delgado/patologia , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Ultrassonografia
4.
Ann Emerg Med ; 74(3): 381-390, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-30926188

RESUMO

STUDY OBJECTIVE: We compare the use and survivorship rate of peripheral intravenous catheters placed in the emergency department (ED) by insertion method. METHODS: We analyzed a prospective cohort of ED patients who received a peripheral intravenous catheter in the ED by ultrasonographically guided or landmark insertion. Research assistants recorded the uses of the ED-inserted catheters during the ED visit and hospitalization. Among subjects admitted, research assistants tracked catheter survivorship for 72 hours or hospital discharge, whichever came first. Research assistants documented reason for catheter removal and whether it was replaced during hospitalization. Premature removal was defined as catheters that were replaced because of mechanical failure, complication, or discomfort. We used multivariate binomial regression to estimate the relative risk of insertion method on premature removal and a Kaplan-Meier curve to compare survivorship duration by insertion method. RESULTS: A cohort of 1,174 patients with a mean age of 45 years and 63% female predominance was analyzed. Catheter use was 73% and 78% in the ED and hospital for the administration of fluids, medications, or contrast agents (and 96% if blood drawn for testing was included). Peripheral intravenous use did not differ significantly in the ED or hospital by insertion method. For 330 patients who were admitted, 132 of 182 patients (73%) in the ultrasonographically guided group and 117 of 148 (79%) in the landmark group had 72-hour catheter survival. Premature removal was not significantly more likely to occur if the catheter was inserted by the ultrasonographically guided method compared with the landmark one (relative risk 1.26; 95% confidence interval 0.88 to 1.80). CONCLUSION: ED-inserted peripheral intravenous catheters were frequently used in the ED and hospital. Peripheral intravenous use and hospital survivorship of ED-inserted peripheral intravenous catheters were similar by insertion method.


Assuntos
Cateterismo Periférico/métodos , Serviço Hospitalar de Emergência/estatística & dados numéricos , Ultrassonografia de Intervenção/estatística & dados numéricos , Estudos de Casos e Controles , Cateterismo Periférico/estatística & dados numéricos , Cateteres de Demora/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
5.
J Clin Ultrasound ; 46(4): 296-298, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-28656661

RESUMO

A retained urethral foreign body is an uncommon presentation in the Emergency Department. The diagnosis and treatment of retained urethral foreign bodies are determined by their size, location, shape, and mobility and often require specialty consultation and operative intervention. In this case of a 74-year-old man with a self-inserted, retained urethral foreign body, we present the utility of a bedside ultrasound to detect the depth, size, and distance from the meatus of the object to guide the approach to extraction of the object at the bedside in the Emergency Department. © 2017 Wiley Periodicals, Inc. J Clin Ultrasound 46:296-298, 2018.


Assuntos
Corpos Estranhos/diagnóstico por imagem , Uretra/diagnóstico por imagem , Idoso , Corpos Estranhos/psicologia , Humanos , Masculino , Comportamento Sexual , Ultrassonografia
6.
Am J Emerg Med ; 35(12): 1984.e3-1984.e7, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28851498

RESUMO

OBJECTIVE: To assess the impact of an ultrasound hypotension protocol in identifying life-threatening diagnoses that were missed in the initial evaluation of patients with hypotension and shock. METHODS: A subset of cases from a previously published prospective study of hypotensive patients who presented at the Emergency Department in a single, academic tertiary care hospital is described. An ultrasound-trained emergency physician performed an ultrasound on each patient using a standardized hypotension protocol. In each case, the differential diagnosis and management plan was solicited from the treating physician immediately before and after the ultrasound. This is a case series of patients with missed diagnoses in whom ultrasound led to a dramatic shift in diagnosis and management by detecting life threatening pathologies. RESULTS: Following a published prospective study of the effect on an ultrasound protocol in 118 hypotensive patients, we identified a series of cases that ultrasound protocol unexpectedly determined serious life threatening diagnoses such as Takotsubo cardiomyopathy, pulmonary embolism, pericardial effusion with tamponade physiology, abdominal aortic aneurysm and perforated viscus resulting in proper diagnoses and management. These hypotensive patients had completely unsuspected but critical diagnoses explaining their hypotension, who in every case had their management altered to target the newly identified life-threatening condition. CONCLUSIONS: A hypotension protocol is an optimal use of ultrasound that exemplifies "right time, right place", and impacts decision-making at the bedside. In cases with undifferentiated hypotension, ultrasound is often the most readily available option to ensure that the most immediate life-threatening conditions are quickly identified and addressed in the order of their risk potential.


Assuntos
Cuidados Críticos , Serviço Hospitalar de Emergência , Hipotensão/diagnóstico por imagem , Hipotensão/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Hipotensão/terapia , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito/estatística & dados numéricos , Estudos Prospectivos
7.
Ann Emerg Med ; 68(1): 10-8, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26475248

RESUMO

STUDY OBJECTIVE: Randomized controlled trials report inconsistent findings when comparing the initial success rate of peripheral intravenous cannulation using landmark versus ultrasonography for patients with difficult venous access. We sought to determine which method is superior for patients with varying levels of intravenous access difficulty. METHODS: We conducted a 2-group, parallel, randomized, controlled trial and randomly allocated 1,189 adult emergency department (ED) patients to landmark or ultrasonography, stratified by difficulty of access and operator. ED technicians performed the peripheral intravenous cannulations. Before randomization, technicians classified subjects as difficult, moderately difficult, or easy access according to visible or palpable veins and perception of difficulty with a landmark approach. If the first attempt failed, we randomized subjects a second time. We compared the initial and second-attempt success rates by procedural approach and difficulty of intravenous access, using a generalized linear mixed regression model, adjusted for operator. RESULTS: The 33 participating technicians enrolled a median of 26 subjects (interquartile range 9 to 55). The initial success rate was 81% but varied significantly by technique and difficulty of access. The initial success rate by ultrasonography was higher than landmark for patients with difficult access (48.0 more successes per 100 tries; 95% confidence interval [CI] 35.6 to 60.3) or moderately difficult access (10. 2 more successes per 100 tries; 95% CI 1.7 to 18.7). Among patients with easy access, landmark yielded a higher success rate (10.6 more successes per 100 tries; 95% CI 5.8 to 15.4). The pattern of second-attempt success rates was similar. CONCLUSION: Ultrasonographic peripheral intravenous cannulation is advantageous among patients with difficult or moderately difficult intravenous access but is disadvantageous among patients anticipated to have easy access.


Assuntos
Cateterismo Periférico/métodos , Ultrassonografia de Intervenção/métodos , Adolescente , Adulto , Serviço Hospitalar de Emergência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
8.
Crit Care Med ; 43(12): 2562-9, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26575653

RESUMO

OBJECTIVES: Utilization of ultrasound in the evaluation of patients with undifferentiated hypotension has been proposed in several protocols. We sought to assess the impact of an ultrasound hypotension protocol on physicians' diagnostic certainty, diagnostic ability, and treatment and resource utilization. DESIGN: Prospective observational study. SETTING: Emergency department in a single, academic tertiary care hospital. SUBJECTS: A convenience sample of patients with a systolic blood pressure less than 90 mm Hg after an initial fluid resuscitation, who lacked an obvious source of hypotension. INTERVENTIONS: An ultrasound-trained physician performed an ultrasound on each patient using a standardized hypotension protocol. Differential diagnosis and management plan was solicited from the treating physician immediately before and after the ultrasound. Blinded chart review was conducted for management and diagnosis during the emergency department and inpatient hospital stay. MEASUREMENTS AND MAIN RESULTS: The primary endpoints were the identification of an accurate cause for hypotension and change in physicians' diagnostic uncertainty. The secondary endpoints were changes in treatment plan, use of resources, and changes in disposition after performing the ultrasound. One hundred eighteen patients with a mean age of 62 years were enrolled. There was a significant 27.7% decrease in the mean aggregate complexity of diagnostic uncertainty before and after the ultrasound hypotension protocol (1.85-1.34; -0.51 [95% CI, -0.41 to -0.62]) as well as a significant increase in the absolute proportion of patients with a definitive diagnosis from 0.8% to 12.7%. Overall, the leading diagnosis after the ultrasound hypotension protocol demonstrated excellent concordance with the blinded consensus final diagnosis (Cohen k = 0.80). Twenty-nine patients (24.6%) had a significant change in the use of IV fluids, vasoactive agents, or blood products. There were also significant changes in major diagnostic imaging (30.5%), consultation (13.6%), and emergency department disposition (11.9%). CONCLUSIONS: Clinical management involving the early use of ultrasound in patients with hypotension accurately guides diagnosis, significantly reduces physicians' diagnostic uncertainty, and substantially changes management and resource utilization in the emergency department.


Assuntos
Serviço Hospitalar de Emergência , Hipotensão/diagnóstico por imagem , Hipotensão/diagnóstico , Hipotensão/terapia , Sistemas Automatizados de Assistência Junto ao Leito , Ressuscitação/métodos , Idoso , Pressão Sanguínea , Transfusão de Sangue/métodos , Fármacos Cardiovasculares/administração & dosagem , Protocolos Clínicos , Cuidados Críticos , Diagnóstico Diferencial , Feminino , Hidratação/métodos , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Ultrassonografia , Incerteza
9.
J Emerg Med ; 48(6): e135-7, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25797933

RESUMO

BACKGROUND: Ocular trauma and acute loss of vision are high-yield patient presentations that may benefit from the use of bedside ultrasound to aid in the diagnosis of a variety of vision-threatening problems. CASE REPORT: We present a case of bilateral lens dislocation in which the diagnosis of lens dislocation was missed on initial computed tomography of the orbits but detected on bedside ultrasound. WHY SHOULD AN EMERGENCY PHYSICIAN BE AWARE OF THIS?: Point-of-care ultrasound can rapidly identify ocular pathology and expedite specialist consultation, and if necessary, transfer to a specialty center for further management.


Assuntos
Ectopia do Cristalino/diagnóstico por imagem , Ectopia do Cristalino/etiologia , Traumatismos Oculares/complicações , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas Automatizados de Assistência Junto ao Leito , Tomografia Computadorizada por Raios X , Ultrassonografia , Violência , Transtornos da Visão/etiologia
10.
Emerg Med J ; 32(10): 804-8, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25612763

RESUMO

OBJECTIVE: To describe the credentialing systems of North American emergency department systems (EDS) with emergency ultrasound (EUS) fellowship programmes. METHODS: This is a prospective, cross-sectional, survey-based study of North American EUS fellowships using a 62-item, pilot-tested, web-based survey instrument assessing credentialing and training systems. The American College of Emergency Physicians (ACEP) distributed the surveys using SNAP survey (Snap Surveys Ltd, Portsmouth, New Hampshire, USA). RESULTS: Over 6 months, 75 eligible programmes were surveyed, 55 responded (73% response rate); 1 declined to participate leaving 54 participating programmes. Less than 20% of EDS credential nurses, physician assistants, nurse practitioners and students in EUS. Respondent EDS reported having an average of 4.2 ± 3.3 ultrasound faculty members (faculty identifying their career focus as EUS). The median number of annual point-of-care ultrasounds reported was 5000 (IQR 3000-8000). 30 EDS (56%) credential each examination individually and 48 EDS (89%) use ACEP credentialing criteria. 61% of fellowship leadership believe their credentialing system is either satisfactory or very satisfactory (Cronbach's coefficient α=0.84). CONCLUSIONS: The data show heterogeneity among North American EDS with EUS fellowship programmes with regard to credentialing systems despite published guidelines from the ACEP and Canadian Emergency Ultrasound Society.


Assuntos
Credenciamento/normas , Medicina de Emergência/educação , Serviço Hospitalar de Emergência/estatística & dados numéricos , Bolsas de Estudo , Ultrassonografia , Atitude do Pessoal de Saúde , Canadá , Competência Clínica/estatística & dados numéricos , Estudos Transversais , Humanos , Estudos Prospectivos , Estados Unidos
12.
J Emerg Med ; 45(5): 698-701, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23988143

RESUMO

BACKGROUND: Identification of fluid in the elbow joint by physical examination alone can be challenging. Ultrasound can assist in the diagnosis of elbow effusion, and guide aspiration of the effusion. OBJECTIVES: We illustrate the anatomy and ultrasound guidance technique of a posterior approach to elbow arthrocentesis using examples of normal and pathologic elbow joint ultrasound images. DISCUSSION: The posterior distal humerus at the level of the olecranon fossa provides an excellent acoustic window into the joint space. This location also provides a safe path for the performance of ultrasound-guided arthrocentesis. CONCLUSION: Ultrasound-guided arthrocentesis of the elbow from a posterior approach is a helpful technique to guide the aspiration of the painful swollen elbow.


Assuntos
Articulação do Cotovelo/diagnóstico por imagem , Paracentese/métodos , Ultrassonografia de Intervenção , Adulto , Artralgia/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fraturas do Rádio/diagnóstico por imagem , Adulto Jovem
13.
Cureus ; 15(7): e42569, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37637589

RESUMO

Introduction Acute COVID-19 patients can suffer from chronic symptoms known as post-acute sequelae of SARS-CoV-2 infection (PASC). Point-of-care ultrasound (POCUS) is established in acute COVID, but its utility in PASC is unclear. We sought to determine the incidence of cardiac and pulmonary abnormalities with POCUS in patients with PASC in a COVID-19 recovery clinic. Methods This prospective cohort study included adults (>18 years old) presenting with cardiopulmonary symptoms to the COVID-19 recovery clinic. A lung ultrasound and standard bedside echocardiogram were performed by ultrasound-trained physicians. Images were interpreted in real time by the performing sonographer and independently by a blinded ultrasound faculty member. Discrepancies in interpretation were addressed by consensus review. A modified Soldati score was calculated by the sum of the scores in each of the 12 lung zones, with each zone score ranging from 0 to 3 (maximum score of 36). The score was then compared to clinical outcomes and outpatient testing.  Results Between April and July 2021, 41 patients received POCUS examinations, with 24 of those included in the study. In all, 15 out of 24 (62.5%) had a normal lung ultrasound. Of the nine subjects with lung abnormalities, the median modified Soldati score was 2. Three patients had trivial pericardial effusions, and all had normal left and right ventricular size and function. Conclusion The majority (62.5%) of patients presenting to the PASC clinic had a normal pulmonary ultrasound, and the vast majority (87.5%) had normal cardiac ultrasounds. These findings suggest that cardiopulmonary symptoms in PASC may be from etiologies not well evaluated by POCUS.

14.
Cureus ; 15(3): e36329, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37077608

RESUMO

Introduction Limited guidance exists for primary and urgent care ultrasound applications. This study sought to identify the most useful applications for providers in these clinical settings, to create and implement a structured interdisciplinary point-of-care ultrasound (POCUS) curriculum, and to assess the effectiveness of the course.  Methods This prospective cohort study took place at an urban academic medical center. After a needs-based assessment of ultrasound applications in primary and urgent care, the Emergency Medicine ultrasound faculty and fellows were paired with a primary or urgent care provider (N = 6). The pairings met for scanning sessions in the emergency department to practice image acquisition, documentation, and incorporation of ultrasound into the workflow. Participants were given POCUS pre-work to review before each session. The final bedside session included a formal Objective Standard Clinical Examination (OSCE) to assess learner proficiency to be cleared for independent imaging. The program was assessed using pre- and post-training surveys.  Results The survey results demonstrated that renal, gallbladder, and soft tissue scans were the most interesting and useful to primary and urgent care providers after completion of the training course.  Conclusion The course was effective, and efficient, simple, high-yield POCUS applications should be included in future programs and organizational guidelines for primary and urgent care POCUS education.

15.
J Emerg Med ; 43(2): 351-5, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21945505

RESUMO

BACKGROUND: The authors describe a Joint Fellowship Curriculum instituted for emergency medicine fellows in diverse fellowships. The curriculum is based on commonalities established among the varying fellowships offered within their Department of Emergency Medicine. Fellowships included in the curriculum development include Disaster/Emergency Medical Services, International Emergency Medicine, Health Policy, Ultrasonography, and Medical Toxicology. OBJECTIVES: The focus of this educational activity is to promote the development of the fellow into an expert within their field of specialization. DISCUSSION: Recognizing that topics such as scholarly activities, career development, clinical practice of medicine, business of medicine, and personal development are universally applicable to a variety of emergency medicine fellowships, the curriculum attempts to provide uniform instruction. The quality and applicability of this instruction was assessed and found to have been very well received by the participating fellows. CONCLUSION: The authors encourage academic emergency medicine departments with a number of fellowship training opportunities to consider providing such a uniform curriculum of instruction as well.


Assuntos
Atitude do Pessoal de Saúde , Currículo , Medicina de Emergência/educação , Bolsas de Estudo , Pesquisa Biomédica , Mobilidade Ocupacional , Medicina de Desastres/educação , Medicina de Emergência/organização & administração , Política de Saúde , Humanos , Liderança , Imperícia , Administração da Prática Médica , Gestão de Riscos , Toxicologia/educação , Ultrassonografia
16.
Am J Emerg Med ; 29(5): 477-81, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-20825815

RESUMO

OBJECTIVES: The aim of this study was to examine the capability of ultrasound-naïve paramedics to obtain interpretable Focused Assessment With Sonography for Trauma (FAST) images under the remote direction of emergency physicians (EPs). METHODS: Paramedics without experience using ultrasound participated in a 20-minute lecture covering orientation to the ultrasound machine and the FAST examination. The paramedics subsequently performed FAST examinations on a model patient, whereas the EP remained in another room, out of visual contact. The EP communicated with the paramedic via radio, viewing video from the ultrasound machine on a monitor and directing the probe movements to obtain the views of the FAST examination. We examined the success rate, time to complete the examinations, and adequacy of images from the paramedics' first FAST examination. RESULTS: Fifty-one paramedics performed their first FAST examinations and were able to successfully complete 100% of the views of the FAST. The median time from probe placement to examination completion was 262 seconds (interquartile range, 206-343 seconds). The median time to complete right upper quadrant (RUQ) versus left upper quadrant (LUQ) views was 39 and 50 seconds, respectively. The time to complete the LUQ scan took significantly longer than the RUQ (P < .01). Paramedics completed cardiac and pelvic view in a median time of 42 and 25 seconds, respectively. CONCLUSIONS: The study demonstrated that paramedics with no prior ultrasound experience could obtain FAST images under remote guidance from experienced EPs in less than 5 minutes. Given rapidly evolving data transmission technology, this has applicability in battlefield, remote, and rural prehospital settings.


Assuntos
Auxiliares de Emergência , Consulta Remota/métodos , Ferimentos e Lesões/diagnóstico por imagem , Ecocardiografia/métodos , Serviços Médicos de Emergência/métodos , Humanos , Pelve/diagnóstico por imagem , Pelve/lesões , Fatores de Tempo
17.
Cureus ; 13(7): e16281, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34377614

RESUMO

Emergency physicians can use point-of-care ultrasound to diagnose inguinal hernias as well as their potential complications, including small bowel obstruction, incarceration, and even strangulation. We provide an overview of the sonographic appearance of inguinal hernias, as well as the diagnostic criteria of serious complications. In this case report, point-of-care ultrasound findings included a non-reducible inguinal hernia associated with significant bowel dilation in multiple loops without signs of intestinal ischemia or necrosis.

18.
Cureus ; 13(5): e15096, 2021 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-34155462

RESUMO

Gout is the most common crystal arthropathy and is frequently diagnosed and managed by primary care physicians. Point-of-care ultrasound (POCUS) is a valuable tool to aid in the diagnosis of gout via the identification of the double contour sign, aggregates of crystals, tophi, and erosions. In addition, POCUS can aid in the management of gout by recognizing early signs of gout, monitoring the effectiveness of urate-lowering therapy, and guiding aspiration and corticosteroid injection.

19.
Cureus ; 13(11): e19539, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34934557

RESUMO

Background and objective Accurate identification and categorization of injuries from medical records can be challenging, yet it is important for injury epidemiology and prevention efforts. Coding systems such as the International Classification of Diseases (ICD) have well-known limitations. Utilizing computer-based techniques such as natural language processing (NLP) can help augment the identification and categorization of diseases in electronic health records. We used a Python program to search the text to identify cases of scooter injuries that presented to our emergency department (ED). Materials and methods This retrospective chart review was conducted between March 2017 and June 2019 in a single, urban academic ED with approximately 80,000 annual visits. The physician documentation was stored as combined PDF files by date. A Python program was developed to search the text from 186,987 encounters to find the string "scoot" and to extract the 100 characters before and after the phrase to facilitate a manual review of this subset of charts. Results A total of 890 charts were identified using the Python program, of which 235 (26.4%) were confirmed as e-scooter cases. Patients had an average age of 36 years and 53% were male. In 81.7% of cases, the patients reported a fall from the scooter and only 1.7% reported wearing a helmet during the event. The most commonly injured body areas were the upper extremity (57.9%), head (42.1%), and lower extremity (36.2%). The most frequently consulted specialists were orthopedic and trauma surgeons with 28% of cases requiring a consult. In our population, 9.4% of patients required admission to the hospital. Conclusions The number of results and data returned by the Python program was easy to manage and made it easier to identify charts for abstraction. The charts obtained allowed us to understand the nature and demographics of e-scooter injuries in our ED. E-scooters continue to be a popular mode of transportation, and understanding injury patterns related to them may inform and guide opportunities for policy and prevention.

20.
Int Marit Health ; 71(1): 42-45, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32212147

RESUMO

Cruise ships travel far from shoreside medical care and present a unique austere medical environment. For the cruise ship physician, decisions regarding emergency medical evacuation can be challenging. In the event that a passenger or crew member becomes seriously ill or is injured, the use of point-of-care ultrasound may assist in clarifying the diagnosis and stratifying the risk of a delayed care, and at times expedite an emergent medical evacuation. In this report we present the first case reported in the literature of an emergency medical evacuation from a cruise ship triggered by handheld ultrasound. A point-of-care ultrasound performed by a trained cruise ship physician, reviewed by a remote telemedical consultant with experience in point-of-care ultrasound, identified an ectopic pregnancy with intraabdominal free fluid in a young female patient with abdominal pain and expedited emergent helicopter evacuation from a cruise ship to a shoreside facility, where she immediately underwent successful surgery. The case highlights a medical evacuation that was accurately triggered by utilising a handheld ultrasound and successfully directed via a tele-ultrasound consultation. American College of Emergency Physicians (ACEP) health care guidelines for cruise ship medical facilities should be updated to include guidelines for point-of-care ultrasound, including training and telemedical support.


Assuntos
Medicina Naval/métodos , Gravidez Ectópica/diagnóstico por imagem , Telemedicina/métodos , Ultrassonografia/métodos , Adulto , Aeronaves , Feminino , Humanos , Gravidez , Navios , Ultrassonografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA