Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Retina ; 41(7): 1547-1552, 2021 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-34137387

RESUMO

PURPOSE: To investigate differences in outcomes of acute retinal necrosis with confirmed viral polymerase chain reaction between viral types and highlight different treatment options. METHODS: The study evaluated 22 eyes in 18 patients of polymerase chain reaction-positive acute retinal necrosis at the University of Pittsburgh Medical Center from 2007 to 2018. Outcome measures included final visual acuity, treatment paradigms, and retinal detachment rate. RESULTS: Eight eyes were polymerase chain reaction-positive for varicella zoster virus, two eyes for herpes simplex virus Type 1 (HSV-1), and 12 eyes for herpes simplex virus Type 2 (HSV-2). Final Snellen best-corrected visual acuity averaged 20/51 for varicella zoster virus, 20/25 for HSV-1, and 20/814 for HSV-2. Retinal detachment occurred in 2 (25%) of varicella zoster virus eyes and 8 (75%) of HSV-2 eyes. One eye with HSV-1 and three eyes with HSV-2 received cidofovir for treatment of refractory retinitis. CONCLUSION: Acute retinal necrosis secondary to HSV-2 tended to have persistent active retinitis with a higher rate of retinal detachment despite similar treatment protocols, suggesting that in some cases combination intravenous acyclovir and adjuvant intravitreal foscarnet injections are not sufficient. Despite the risk of renal toxicity, intravenous cidofovir may be a consideration in select patients.


Assuntos
Aciclovir/uso terapêutico , Infecções Oculares Virais/tratamento farmacológico , Foscarnet/uso terapêutico , Herpes Zoster Oftálmico/tratamento farmacológico , Síndrome de Necrose Retiniana Aguda/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antivirais/uso terapêutico , DNA Viral/análise , Infecções Oculares Virais/diagnóstico , Feminino , Seguimentos , Herpes Zoster Oftálmico/diagnóstico , Herpesvirus Humano 3/genética , Humanos , Masculino , Pessoa de Meia-Idade , Síndrome de Necrose Retiniana Aguda/diagnóstico , Estudos Retrospectivos , Resultado do Tratamento , Acuidade Visual
2.
J Neuroophthalmol ; 41(3): e357-e359, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-33136676

RESUMO

ABSTRACT: A 44-year-old woman noticed bilateral irregular scotomata associated with photopsias of 6-month duration. Ophthalmoscopic examination demonstrated multiple bilateral, pericentral, hypopigmented, petaloid, macular lesions evident on Amsler grid associated with paracentral hyperreflective lesions on optical coherence tomography in the outer plexiform and nuclear layers. Indocyanine green angiography revealed patches of choroidal ischemia consistent with acute macular neuroretinopathy.


Assuntos
Angiofluoresceinografia/métodos , Macula Lutea/diagnóstico por imagem , Imagem Multimodal , Tomografia de Coerência Óptica/métodos , Acuidade Visual , Campos Visuais/fisiologia , Síndrome dos Pontos Brancos/diagnóstico , Adulto , Feminino , Fundo de Olho , Humanos
3.
J Vitreoretin Dis ; 8(5): 546-553, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39318983

RESUMO

Purpose: To identify and describe adverse events (AEs) observed with real-world use of the following 3 vitrectomy platforms: Constellation (Alcon), Enhancing Visual Acuity (EVA, Dutch Ophthalmic Research Center), and Stellaris (Bausch + Lomb). Methods: All reports submitted to the US Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) database between January 2010 and November 2021 that were associated with the 3 vitrectomy platforms were analyzed. Each report was reviewed for AEs or consequences and the type of complication noted. Duplicates and reports with an inadequate narrative to categorize the event were excluded. A descriptive analysis was performed for the prevalence of device-specific issues within each platform. Results: The analysis included 2534 reports (1738 Constellation, 117 EVA, 679 Stellaris). Overall, the most commonly reported complications involved the vitrectomy probe (n = 957 [37.8%]) and the central processing unit (n = 368 [14.5%]). Differences in the distribution of AEs among the platforms were noted, with vitrectomy probe issues being the most reported events for the Constellation and Stellaris and infusion issues for the EVA. Infusion issues most frequently led to reports of patient harm with the Constellation (31/1738 [1.8%]) and EVA (7/116 [6.0%]), while issues with the vitrectomy probe were reported with the Stellaris (11/679 [1.6%]). Conclusions: An analysis of real-world data in the MAUDE database highlighted the spectrum of device-specific AEs of greatest relevance to surgical practice. Familiarity with potential device complications will help minimize harm to patients.

4.
Retin Cases Brief Rep ; 16(3): 314-317, 2022 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-31958106

RESUMO

PURPOSE: To characterize evolution of macular injury from a high-powered blue handheld laser using multimodal imaging and describe successful surgical treatment. METHODS: Observational clinical case report. RESULTS: A 17-year-old boy presented with unilateral acute loss of vision with discrete white macular lesions, full-thickness disruption of retinal layers, and hyperreflective material at the fovea on optical coherence tomography caused by exposure to a 445 nm blue-light handheld laser with power up to 2,000 mW characterized as a Class IV laser. The injury evolved into an approximately 950-µm full-thickness macular hole 3 weeks later with visual acuity of 20/400. Vitrectomy and internal limiting membrane peel resulted in anatomic success and final vision at 4 months of 20/25. CONCLUSION: High-powered lasers can induce significant disruption of retinal layers, inflammatory debris, and full-thickness macular holes with momentary exposure that, despite poor anatomic prognostic factors, can have successful surgical outcomes.


Assuntos
Degeneração Macular , Doenças Retinianas , Perfurações Retinianas , Adolescente , Humanos , Lasers , Masculino , Imagem Multimodal , Doenças Retinianas/complicações , Doenças Retinianas/etiologia , Perfurações Retinianas/diagnóstico , Perfurações Retinianas/etiologia , Perfurações Retinianas/cirurgia , Tomografia de Coerência Óptica , Vitrectomia/efeitos adversos
5.
J Vitreoretin Dis ; 6(4): 329-331, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-37007923

RESUMO

Purpose: This article describes a case of didanosine (DDI)-associated retinal toxicity in a patient with a heterozygous pathogenic variant in the CRB1 gene. Methods: Case report. Results: A middle-aged patient with HIV controlled on HAART therapy, and a remote 10-year year history of treatment with DDI and tenofivir, presented with external ophthalmoplegia and well-circumscribed, midperipheral patterns of bilateral pigmentary retinopathy and chorioretinal atrophy in both eyes. Genetic testing revealed a heterozygous pathogenic variant in the CRB1 gene that encodes a protein (Crumbs homolog 1) involved in regulation of cell polarity and junctions and is localized adjacent to mitochondria in the ellipsoid and myoid area. Conclusions: This case highlights a potential role for genetic susceptibility to retinal toxicity in DDI-associated retinal toxicity. Large, prospective pharmacogenomics studies may be informative to further elucidate the role of genetic risk factors in drug-induced retinal toxicity.

6.
Am J Ophthalmol Case Rep ; 26: 101556, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35514795

RESUMO

Purpose: To report a case of multilayered intraocular hemorrhage at the posterior pole as a complication of transorbital neuroendoscopic surgery. Observations: Our patient underwent an uncomplicated endoscopic transorbital resection of a left sphenoid wing meningioma. In the immediate post-operative period, the patient reported blurred vision of her left eye, and dilated fundus examination demonstrated multilayered hemorrhages at the posterior pole. No intracranial hemorrhage was identified on post-operative imaging. Due to persistent subnormal visual acuity and non-clearing hemorrhage over several weeks of follow-up, a pars plana vitrectomy with peeling of the internal limiting membrane was performed to clear the hemorrhagic component obscuring the macula. Conclusions and Importance: We report the first case of multilayered intraocular hemorrhages at the posterior pole, mimicking Terson syndrome, in the absence of intracranial hemorrhage or elevated intracranial pressure as a complication of transorbital surgery.

7.
Am J Ophthalmol ; 221: 273-278, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32777376

RESUMO

OBJECTIVE: To report clinical features and visual outcomes following eyelet fractures of scleral-sutured enVista MX60 (Bausch + Lomb) intraocular lenses (IOL). DESIGN: Retrospective, multi-center, multi-surgeon, observational case series. METHODS: Study Population: Patients with scleral-sutured enVista MX60 IOLs that experienced either an intraoperative or post-operative eyelet fracture associated with dislocation or subluxation. PROCEDURES: All records were reviewed for patients with a dislocated or subluxed scleral-sutured enVista MX60 IOL. Clinical features and outcomes were gathered. Main Outcome Measures: Clinical setting, surgical technique, complications, and visual acuity. RESULTS: A total of 25 scleral-sutured enVista MX60 IOLs displacements secondary to eyelet fractures in 23 eyes of 23 patients were included. There were 20 IOLs that sustained a postoperative fracture and 5 IOLs that sustained an intraoperative fracture. Of the postoperative fractures, 7 were dislocated and 13 were subluxed. Gore-Tex was the suture of choice for 19 of the postoperative fractures and all 5 of the intraoperative fractures, and Prolene was used for 1 postoperative fracture. The mean time until postoperative fracture was 96 ± 125 days, and the median time was 61 (IQR 48-144) days. Of the postoperative fractures, new MX60s were sutured in 10 patients, and 2 of them experienced repeat displacements due to a new eyelet fracture. In the intraoperative fracture group, new MX60s were sutured in 4 patients and an Akreos AO60 lens was placed in the 5th patient. The mean preoperative best-corrected logMAR visual acuity for all patients improved from 1.2 ± 0.8 (20/317 Snellen equivalent) to 0.5 ± 0.5 (20/63 Snellen equivalent) at most recent follow-up after lens replacement. CONCLUSIONS: Scleral-sutured MX60 intraocular lenses can experience intraoperative or postoperative eyelet fractures, resulting in lens subluxation or dislocation. Surgeons should be aware of this complication when evaluating secondary intraocular lens options.


Assuntos
Migração do Implante de Lente Intraocular/etiologia , Complicações Intraoperatórias , Implante de Lente Intraocular/métodos , Complicações Pós-Operatórias , Falha de Prótese/etiologia , Esclera/cirurgia , Técnicas de Sutura , Adulto , Idoso , Idoso de 80 Anos ou mais , Migração do Implante de Lente Intraocular/diagnóstico , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Facoemulsificação , Estudos Retrospectivos , Fatores de Tempo , Acuidade Visual/fisiologia , Vitrectomia
8.
Am J Ophthalmol Case Rep ; 18: 100636, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32154437

RESUMO

PURPOSE: To describe an unusual case of bilateral acute retinal necrosis (ARN) that was caused by varicella zoster virus in one eye and Epstein-Barr virus in the fellow eye. OBSERVATIONS: A 67-year-old immunocompromised man presented with ARN in the left eye following a dermatomal vesicular rash, with an aqueous sample positive for varicella zoster virus. Four months later, the patient presented with panuveitis and serous retinal detachment in the right eye, with vitreous sample positive for Epstein-Barr virus and negative for varicella zoster, herpes simplex, and cytomegalovirus. CONCLUSIONS AND IMPORTANCE: We report a rare case of bilateral ARN with independent infection of each eye by different viruses; varicella zoster in the left eye and, four months later, Epstein-Barr virus in the right eye. Immunocompromised patients are vulnerable to ARN from any of its inciting viral causes, and intraocular fluid should be obtained for diagnostic confirmation from the second eye in cases of bilateral ARN.

9.
Ophthalmol Retina ; 3(6): 468-472, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31174667

RESUMO

PURPOSE: To report refractive outcomes of scleral-fixated intraocular lens (IOL) implantation with Gore-Tex (W.L. Gore & Associates, Newark, DE) suture and combined pars plana vitrectomy and compare predicted refractive outcomes among 5 IOL power calculation formulas. DESIGN: Retrospective case series. PARTICIPANTS: Patients undergoing scleral-fixated IOL implantation with Gore-Tex suture at our institution between January 2015 and June 2018. METHODS: Comparison of preoperative biometrics with postoperative refraction and calculation of predicted refractive outcome with 5 different IOL formulas. MAIN OUTCOME MEASURES: Prediction error and absolute error to compare postoperative refraction with refraction predicted by lens power calculation formulas. RESULTS: Thirty-one eyes of 31 patients were included. All power calculations assumed in-the-bag position of the IOL. The Akreos A060 (Bausch & Lomb, Rochester, NY) was implanted in 23 eyes and the CZ70BD (Alcon, Fort Worth, TX) in 8 eyes, and all lenses were sutured 3 mm behind the limbus. Average postoperative spherical equivalent (SE) was -0.79±0.95 diopters (D). Average prediction error (postoperative SE refraction minus target refraction) was -0.19±0.72 D. Postoperative SE was within 1.0 D of target in 25 of 31 patients (81%) and 2.0 D of target in 31 of 31 patients (100%). The repeated-measures analysis of variance of absolute error by lens power formula was significant (P = 0.012), with Haigis demonstrating greater error. There was no significant difference among Barrett II, Sanders-Retzlaff-Kraff theoretical (SRK/T), Holladay 2, or Hoffer Q. CONCLUSIONS: For eyes undergoing pars plana vitrectomy with scleral-sutured IOL implantation, assumption of in-the-bag IOL position when calculating lens power leads to acceptable refractive outcomes. Barrett II, SRK/T, Holladay 2, and Hoffer Q formulas were noninferior to each other.


Assuntos
Oftalmopatias/cirurgia , Implante de Lente Intraocular/métodos , Lentes Intraoculares , Óptica e Fotônica , Refração Ocular/fisiologia , Esclera/cirurgia , Técnicas de Sutura/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Câmara Anterior/cirurgia , Biometria , Oftalmopatias/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Politetrafluoretileno , Desenho de Prótese , Estudos Retrospectivos , Suturas , Resultado do Tratamento , Acuidade Visual , Vitrectomia/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA