Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 44
Filtrar
1.
Cerebellum ; 22(6): 1123-1136, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36214998

RESUMO

The olivo-cerebellar circuit is thought to play a crucial role in the pathophysiology of essential tremor (ET). Whether olivo-cerebellar circuit dysfunction is also present at rest, in the absence of clinical tremor and linked voluntary movement, remains unclear. Assessing this network in detail with fMRI is challenging, considering the brainstem is close to major arteries and pulsatile cerebrospinal fluid-filled spaces obscuring signals of interest. Here, we used methods tailored to the analysis of infratentorial structures. We hypothesize that the olivo-cerebellar circuit shows altered intra-network connectivity at rest and decreased functional coupling with other parts of the motor network in ET. In 17 ET patients and 19 healthy controls, we investigated using resting state fMRI intracerebellar functional and effective connectivity on a dedicated cerebellar atlas. With independent component analysis, we investigated data-driven cerebellar motor network activations during rest. Finally, whole-brain connectivity of cerebellar motor structures was investigated using identified components. In ET, olivo-cerebellar pathways show decreased functional connectivity compared with healthy controls. Effective connectivity analysis showed an increased inhibitory influence of the dentate nucleus towards the inferior olive. Cerebellar independent component analyses showed motor resting state networks are less strongly connected to the cerebral cortex compared to controls. Our results indicate the olivo-cerebellar circuit to be affected at rest. Also, the cerebellum is "disconnected" from the rest of the motor network. Aberrant activity, generated within the olivo-cerebellar circuit could, during action, spread towards other parts of the motor circuit and potentially underlie the characteristic tremor of this patient group.


Assuntos
Tremor Essencial , Humanos , Tremor Essencial/diagnóstico por imagem , Tremor , Imageamento por Ressonância Magnética/métodos , Cerebelo , Encéfalo , Mapeamento Encefálico , Vias Neurais/diagnóstico por imagem
2.
J Neuroeng Rehabil ; 17(1): 45, 2020 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-32183867

RESUMO

BACKGROUND: Parkinson's disease (PD) and essential tremor (ET) are neurodegenerative diseases characterized by movement deficits. Especially in PD, maintaining cyclic movement can be significantly disturbed due to pathological changes in the basal ganglia and the cerebellum. Providing external cues improves timing of these movements in PD and also affects ET. The aim of this study is to determine differences in cortical activation patterns in PD and ET patients during externally and internally cued movements. METHODS: Eleven PD patients, twelve ET patients, OFF tremor suppressing medication, and nineteen age-matched healthy controls (HC) were included and asked to perform a bimanual tapping task at two predefined cue frequencies. The auditory cue, a metronome sound presented at 2 or 4 Hz, was alternately switched on and off every 30 s. Tapping at two different frequencies were used since it is expected that different brain networks are involved at different frequencies as has been shown in previous studies. Cortical activity was recorded using a 64-channel EEG cap. To establish the cortical activation pattern in each group, the task related power (TRP) was calculated for each subject. For inter-groups analysis, EEG electrodes for divided into 5 different areas. RESULTS: Inter-group analysis revealed significant differences in areas responsible for motor planning, organization and regulation and involved in initiation, maintenance, coordination and planning of complex sequences of movements. Within the area of the primary motor cortex the ET group showed a significantly lower TRP than the HC group. In the area responsible for combining somatosensory, auditory and visual information both patient groups had a higher TRP than the HC group. CONCLUSIONS: Different neurological networks are involved during cued and non-cued movements in ET, PD and HC. Distinct cortical activation patterns were revealed using task related power calculations. Different activation patterns were revealed during the 2 and 4 Hz tapping task indicating different strategies to execute movements at these rates. The results suggest that a including a cued/non-cued tapping task during clinical decision making could be a valuable tool in an objective diagnostic protocol.


Assuntos
Encéfalo/fisiopatologia , Sinais (Psicologia) , Tremor Essencial/fisiopatologia , Destreza Motora/fisiologia , Doença de Parkinson/fisiopatologia , Idoso , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
3.
J Neuroeng Rehabil ; 16(1): 54, 2019 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-31064378

RESUMO

BACKGROUND: The basal ganglia and cerebellum are brain structures involved in movement initiation, execution and termination. They are thought to be involved in the tremor generation and movement deficits in Parkinson's disease (PD) and essential tremor (ET). Especially in PD, maintaining cyclic movement, such as walking or tapping can be significantly disturbed. Providing external cues improves timing of these movements in PD but its effect on ET has not yet been studied in depth. The aim of this study is to evaluate the usefulness of a bimanual tapping task as a tool during clinical decision making. METHOD: Hand movements and tremor was recorded using accelerometers and EMG (m. extensor carpi ulnaris) from PD and ET patients and healthy controls during a bimanual tapping task as a way to distinguish PD from ET. All subjects performed the tapping task at two different frequencies, 2 Hz and 4 Hz, with and without the presence of auditory cues. RESULTS: No significant intra-group differences were found in the patient groups. Acceleration data revealed significantly less accurate tapping and more variable tapping in PD than in ET and healthy controls. ET subjects tapped less accurate and with a greater variability than healthy controls during the 4 Hz tapping task. Most interestingly the tapping accuracy improved in PD patients when kinetic tremor was recorded with EMG during the task. CONCLUSION: Providing ET and PD patients with an external cue results in different tapping performances between patient groups and healthy controls. Furthermore, the findings suggest that kinetic tremor in PD enables patients to perform the task with a greater accuracy. So far this has not been shown in other studies.


Assuntos
Destreza Motora/fisiologia , Doença de Parkinson/fisiopatologia , Idoso , Sinais (Psicologia) , Tremor Essencial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
4.
Sensors (Basel) ; 19(19)2019 Oct 04.
Artigo em Inglês | MEDLINE | ID: mdl-31590227

RESUMO

There is no objective gold standard to detect tremors. This concerns not only the choice of the algorithm and sensors, but methods are often designed to detect tremors in one specific group of patients during the performance of a specific task. Therefore, the aim of this study is twofold. First, an objective quantitative method to detect tremor windows (TWs) in accelerometer and electromyography recordings is introduced. Second, the tremor stability index (TSI) is determined to indicate the advantage of detecting TWs prior to analysis. Ten Parkinson's disease (PD) patients, ten essential tremor (ET) patients, and ten healthy controls (HC) performed a resting, postural and movement task. Data was split into 3-s windows, and the power spectral density was calculated for each window. The relative power around the peak frequency with respect to the power in the tremor band was used to classify the windows as either tremor or non-tremor. The method yielded a specificity of 96.45%, sensitivity of 84.84%, and accuracy of 90.80% of tremor detection. During tremors, significant differences were found between groups in all three parameters. The results suggest that the introduced method could be used to determine under which conditions and to which extent undiagnosed patients exhibit tremors.


Assuntos
Eletromiografia , Tremor Essencial/diagnóstico , Doença de Parkinson/diagnóstico , Idoso , Tremor Essencial/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento/fisiologia , Doença de Parkinson/fisiopatologia
5.
Neuromodulation ; 21(6): 553-561, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29034586

RESUMO

OBJECTIVE: Novel deep brain stimulation (DBS) lead designs are currently entering the market, which are hypothesized to provide a way to steer the stimulation field away from neural populations responsible for side effects and towards populations responsible for beneficial effects. The objective of this study is to assess the performances of a new eight channel steering-DBS lead and compare this with a conventional cylindrical contact (CC) lead. APPROACH: The two leads were evaluated in a finite element electric field model combined with multicompartment neuron and axon models, representing the internal capsule (IC) fibers and subthalamic nucleus (STN) cells. We defined the optimal stimulation setting as the configuration that activated the highest percentage of STN cells, without activating any IC fibers. With this criterion, we compared monopolar stimulation using a single contact of the steering-DBS lead and CC lead, on three locations and four orientations of the lead. In addition, we performed a current steering test case by dividing the current over two contacts with the steering-DBS lead in its worst-case orientation. MAIN RESULTS: In most cases, the steering-DBS lead is able to stimulate a significantly higher percentage of STN cells compared to the CC lead using single contact stimulation or using a two contact current steering protocol when there is approximately a 1 mm displacement of the CC lead. The results also show that correct placement and orientation of the lead in the target remains an important aspect in achieving the optimal stimulation outcome. SIGNIFICANCE: Currently, clinical trials are set up in Europe with a similar design as the steering-DBS lead. Our results illustrate the importance of the orientation of the new steering-DBS lead in avoiding side effects induced by stimulation of IC fibers. Therefore, in clinical trials sufficient attention should be paid to implanting the steering DBS-lead in the most effective orientation.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Cápsula Interna/fisiologia , Modelos Neurológicos , Neurônios/fisiologia , Núcleo Subtalâmico/citologia , Biofísica , Simulação por Computador , Humanos , Núcleo Subtalâmico/fisiologia
6.
J Neurophysiol ; 118(5): 2628-2635, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-28701548

RESUMO

Cortical involvement in essential tremor, an involuntary action tremor supposedly of subcortical origin, is uncertain. Conflicting results of corticomuscular coherence studies in essential tremor suggest an intermittent corticomuscular coupling. On the basis of the literature, we hypothesized that corticomuscular coupling is influenced by bilateral motor synchronization and "cognitive states" such as awareness of tremor. In the present study, we investigated 1) the existence of intermittent corticomuscular coherence (CMC) in essential tremor and 2) factors that influence CMC strength. In 18 essential tremor patients and 18 healthy controls, who mimicked tremor, we simultaneously recorded 64-channel EEG and 6-channel bipolar surface EMG from right and left wrist extensors and flexors. Right-sided (mimicked) hand tremor was recorded with and without a cognitive arithmetic task and with left-sided (mimicked) hand tremor. CMC values per task were compared within and between groups. Changes in CMC strength during tasks were calculated. Our main findings are 1) significant CMC around the (mimicked) tremor frequency across all tasks in both groups; 2) significant differences in CMC between unilateral tasks, with the highest values during the cognitive task only in the essential tremor group; and 3) significant fluctuations of CMC strength over time, independent of the tremor intensity, only in the essential tremor group. Our results suggest a limited role, and certainly not a continuous steering role, of sensorimotor cortical neurons in the generation of tremor. In clinical practice, these findings might help to standardize tremor registration and the interpretation of the analysis.NEW & NOTEWORTHY The part of the motor cortex involved in essential tremor is uncertain. The current electrophysiological study is the first to assess corticomuscular coherence systematically. The study shows a dynamic nature of corticomuscular coherence and a possible influence of cognitive states. The results elucidate the involvement of the motor cortex in tremor and help interpret the varying results in the literature. In clinical practice, the findings may guide in standardizing tremor registration and its interpretation.


Assuntos
Tremor Essencial/fisiopatologia , Córtex Motor/fisiopatologia , Adulto , Idoso , Estudos de Casos e Controles , Cognição , Eletroencefalografia , Feminino , Mãos/inervação , Mãos/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia
7.
Hum Brain Mapp ; 33(1): 246-52, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21547982

RESUMO

The nucleus accumbens and medial frontal cortex (MFC) are part of a loop involved in modulating behavior according to anticipated rewards. However, the precise temporal landscape of their electrophysiological interactions in humans remains unknown because it is not possible to record neural activity from the nucleus accumbens using noninvasive techniques. We recorded electrophysiological activity simultaneously from the nucleus accumbens and cortex (via surface EEG) in humans who had electrodes implanted as part of deep-brain-stimulation treatment for obsessive-compulsive disorder. Patients performed a simple reward motivation task previously shown to activate the ventral striatum. Spectral Granger causality analyses were applied to dissociate "top-down" (cortex → nucleus accumbens)- from "bottom-up" (nucleus accumbens → cortex)-directed synchronization (functional connectivity). "Top-down"-directed synchrony from cortex to nucleus accumbens was maximal over medial frontal sites and was significantly stronger when rewards were anticipated. These findings provide direct electrophysiological evidence for a role of the MFC in modulating nucleus accumbens reward-related processing and may be relevant to understanding the mechanisms of deep-brain stimulation and its beneficial effects on psychiatric conditions.


Assuntos
Lobo Frontal/fisiologia , Motivação , Núcleo Accumbens/fisiologia , Recompensa , Adulto , Mapeamento Encefálico , Eletroencefalografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Vias Neurais/fisiologia , Testes Neuropsicológicos
8.
Mov Disord ; 27(3): 435-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22213381

RESUMO

BACKGROUND: Deep brain stimulation of the subthalamic nucleus alleviates motor symptoms in Parkinson's disease patients. However, some patients suffer from cognitive and emotional changes. These side effects are most likely caused by current spread to the cognitive and limbic territories in the subthalamic nucleus. The aim of this study was to identify the motor part of the subthalamic nucleus to reduce stimulation-induced behavioral side effects, by using motor cortex stimulation. METHODS: We describe the results of subthalamic nucleus neuronal responses to stimulation of the hand area of the motor cortex and evaluate the safety of this novel technique. RESULTS: Responses differed between regions within the subthalamic nucleus. In the anterior and lateral electrode at dorsal levels of the subthalamic nucleus, an early excitation (∼5-45 ms) and subsequent inhibition (45-105 ms) were seen. The lateral electrode also showed a late excitation (∼125-160 ms). Focal seizures were observed following motor cortex stimulation. CONCLUSIONS: To prevent seizures the current density should be lowered, so that motor cortex stimulation-evoked responses can be safely used during deep brain stimulation surgery.


Assuntos
Córtex Cerebral/fisiologia , Estimulação Encefálica Profunda/métodos , Neurônios/fisiologia , Doença de Parkinson/terapia , Núcleo Subtalâmico/patologia , Potenciais de Ação/fisiologia , Idoso , Potencial Evocado Motor/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Eur J Neurosci ; 33(7): 1275-80, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21366725

RESUMO

Parkinsonian patients, who have had a unilateral pallidotomy, may require bilateral deep brain stimulation of the subthalamic nucleus (STN), due to disease progression. The current model of the basal ganglia circuitry does not predict a direct effect of pallidotomy on the neuronal activity of the ipsilateral STN. To date, only three studies have investigated the effect of pallidotomy on overall activity of the STN or neuronal firing rate, but not on the spectral content of the neuronal oscillatory activity. Moreover, none of these studies attempted to differentiate the effects on the dorsal (sensory-motor) and ventral (associative-limbic) parts of the STN. We studied the effect of pallidotomy on spectral power in six frequency bands in the STN ipsilateral and contralateral to pallidotomy from seven patients and in 60 control nuclei of patients without prior functional neurosurgery, and investigated whether this effect is different on the dorsal and ventral STN. The data show that pallidotomy suppresses beta power (13-30 Hz) in the ipsilateral STN. This effect tends predominantly to be present in the dorsal part of the STN. In addition, spectral power in the frequency range 3-30 Hz is significantly higher in the dorsal part than in the ventral part. The effect of pallidotomy on STN neural activity is difficult to explain with the current model of basal ganglia circuitry and should be envisaged in the context of complex modulatory interactions in the basal ganglia.


Assuntos
Eletrofisiologia/métodos , Neurônios/fisiologia , Palidotomia/efeitos adversos , Doença de Parkinson/fisiopatologia , Doença de Parkinson/cirurgia , Núcleo Subtalâmico/fisiologia , Núcleo Subtalâmico/fisiopatologia , Idoso , Estimulação Encefálica Profunda , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Núcleo Subtalâmico/citologia
10.
Acta Neurochir (Wien) ; 152(12): 2069-77, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20949292

RESUMO

BACKGROUND: Intraoperative microelectrode recording (MER) for targeting during deep brain stimulation (DBS) procedures has been evaluated over a period of 4 years, in 57 consecutive patients with Parkinson's disease, who received DBS in the subthalamic nucleus (STN-DBS), and 28 consecutive patients with either dystonia (23) or Parkinson's disease (five), in whom the internal segment of the globus pallidus (GPi-DBS) was targeted. METHODS: The procedure for DBS was a one-stage bilateral stereotactic approach using a combined electrode for both MER and macrostimulation. Up to five micro/macro-electrodes were used in an array with a central, lateral, medial, anterior, and posterior position. Final target location was based on intraoperative test stimulation. FINDINGS: For the STN, the central trajectory was chosen for implantation in 50% of the cases and for the globus pallidus internus (GPi) in 57% of the cases. Furthermore, in 64% of the cases, the channel selected for the permanent electrode corresponded with the trajectory having the longest segment of STN MER activity. For the GPi, this was the case in 61%. The mean and standard deviation of the deepest contact point with respect to the magnetic resonance imaging (MRI)-based target for the STN was 2.1 ± 1.5 mm and for the GPi was -0.5 ± 1.2 mm. CONCLUSIONS: MER facilitates the selection of the final electrode location in STN-DBS and GPi-DBS, and based on the observed MER activity, a pre-selection could be made as to which channel would be the best candidate for macro-test stimulation and at which depth should be stimulated. The choice of the final location is based on intraoperative test stimulation, and it is demonstrated that regularly it is not the central channel that is chosen for implantation. On average, the target as defined by MER activity intensity was in accordance with the MRI-based targets both for the STN and GPi. However, the position of the best MER activity did not necessarily correlate with the locus that produced the most beneficial clinical response on macroelectrode testing intraoperatively.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Estimulação Encefálica Profunda/métodos , Eletrodos Implantados , Globo Pálido/cirurgia , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Doença de Parkinson/cirurgia , Núcleo Subtalâmico/cirurgia , Estimulação Elétrica/instrumentação , Estimulação Elétrica/métodos , Eletrofisiologia/instrumentação , Eletrofisiologia/métodos , Globo Pálido/fisiologia , Humanos , Período Intraoperatório , Microeletrodos , Núcleo Subtalâmico/fisiologia
11.
Brain Sci ; 9(3)2019 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-30832214

RESUMO

Motor improvement after deep brain stimulation (DBS) in the subthalamic nucleus (STN) may vary substantially between Parkinson's disease (PD) patients. Research into the relation between improvement and active contact location requires a correction for anatomical variation. We studied the relation between active contact location relative to the neurophysiological STN, estimated by the intraoperative microelectrode recordings (MER-based STN), and contralateral motor improvement after one year. A generic STN shape was transformed to fit onto the stereotactically defined MER sites. The location of 43 electrodes (26 patients), derived from MRI-fused CT images, was expressed relative to this patient-specific MER-based STN. Using regression analyses, the relation between contact location and motor improvement was studied. The regression model that predicts motor improvement based on levodopa effect alone was significantly improved by adding the one-year active contact coordinates (R² change = 0.176, p = 0.014). In the combined prediction model (adjusted R² = 0.389, p < 0.001), the largest contribution was made by the mediolateral location of the active contact (standardized beta = 0.490, p = 0.002). With the MER-based STN as a reference, we were able to find a significant relation between active contact location and motor improvement. MER-based STN modeling can be used to complement imaging-based STN models in the application of DBS.

12.
Int J Neural Syst ; 29(4): 1850012, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-29768988

RESUMO

Deep brain stimulation (DBS) of the anterior nucleus of the thalamus (ANT) is a promising treatment for patients with refractory epilepsy. However, therapy response varies and precise positioning of the DBS lead is potentially essential for maximizing therapeutic efficacy. We investigate if single-cell recordings acquired by microelectrode recordings can aid targeting of the ANT during surgery and hypothesize that the neuronal firing properties of the target region relate to clinical outcome. We prospectively included 10 refractory epilepsy patients and performed microelectrode recordings under general anesthesia to identify the change in neuronal signals when approaching and transecting the ANT. The neuronal firing properties of the target region, anatomical locations of microelectrode recordings and active contact positions of the DBS lead along the recorded trajectory were compared between responders and nonresponders to DBS. We obtained 19 sets of recordings from 10 patients (five responders and five nonresponders). Amongst the 403 neurons detected, 365 (90.6%) were classified as bursty. Entry into the ANT was characterized by an increase in firing rate while exit of the ANT was characterized by a decrease in firing rate. Comparing the trajectories of responders to nonresponders, we found differences neither in the neuronal firing properties themselves nor in their locations relative to the position of the active contact. Single-cell firing rate acquired by microelectrode recordings under general anesthesia can thus aid targeting of the ANT during surgery, but is not related to clinical outcome in DBS for patients with refractory epilepsy.


Assuntos
Núcleos Anteriores do Tálamo/fisiologia , Estimulação Encefálica Profunda/métodos , Epilepsia Resistente a Medicamentos/terapia , Neurônios/fisiologia , Adulto , Idoso , Núcleos Anteriores do Tálamo/citologia , Núcleos Anteriores do Tálamo/diagnóstico por imagem , Estimulação Encefálica Profunda/instrumentação , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/fisiopatologia , Feminino , Humanos , Masculino , Microeletrodos , Pessoa de Meia-Idade , Estudos Prospectivos
13.
Mov Disord ; 22(9): 1299-307, 2007 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17486590

RESUMO

The pathophysiology of Myoclonus-Dystonia (M-D), an autosomal dominantly inherited movement disorder is largely unknown. In different forms of dystonia abnormal intermuscular coherence is present. The objective of this study was to investigate whether the myoclonic and dystonic features are the result of an abnormal common drive to the muscles in M-D. Coherence analysis was performed in 20 DYT11 mutation carriers (MC) and 13 healthy controls during resting condition and during weak isometric contraction of the arm and neck. The EMG-EMG coherence analysis showed significantly increased intermuscular 3 to 10 Hz coherence in 4 DYT11 MC with clinical pronounced (mobile and static) dystonia. This coherence was not present in DYT11 MC with mild (static) dystonia and/or predominating myoclonus. The EEG-EMG analysis showed significant 15 to 30 Hz coherence during weak isometric contraction of the arm in five healthy controls, but in none of the DYT11 MC. The intermuscular coherence in the low frequency band in DYT11 MC with predominant dystonia is concordant with the previously described coherence in dystonia and suggests that the pathophysiology of M-D shares common pathophysiological features with dystonia. The absence of 15 to 30 Hz EEG-EMG coherence in DYT11 MC may reflect abnormal motor activation caused by an altered cortical drive because of the basal ganglia dysfunction.


Assuntos
Distonia Muscular Deformante/fisiopatologia , Distonia/fisiopatologia , Distúrbios Distônicos/fisiopatologia , Adolescente , Adulto , Idoso , Distonia Muscular Deformante/genética , Distúrbios Distônicos/patologia , Eletroencefalografia/métodos , Eletromiografia/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Movimento , Músculo Esquelético/inervação , Músculo Esquelético/fisiopatologia
14.
Schizophr Res ; 95(1-3): 54-60, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17656071

RESUMO

Patients with schizophrenia consistently perform worse than healthy controls on the antisaccade task in which the subject is required to inhibit a reflexive saccade to a suddenly appearing visual target and look in the opposite direction. To our knowledge there is no research yet showing how patients at ultra high risk (UHR) for developing psychosis perform on the antisaccade task. The aim of the present study was to investigate antisaccade task performance in UHR patients. Patients were eligible for the study when they met criteria for one or more of the following groups: Attenuated symptoms or brief limited intermitted psychotic symptoms or a first-degree family member with a psychotic disorder and reduced functioning or basic symptoms. In 35 UHR patients we assessed antisaccades, neuropsychological test performance and symptomatology. Antisaccade task results were compared with those obtained in 42 age- and intelligence-matched patients with recent-onset schizophrenia and 28 matched healthy controls. Antisaccade error rate was significantly higher in the UHR patients than in the controls. Schizophrenia patients performed worse than the UHR patients and the control subjects. We found a trend towards higher antisaccade error rate at baseline in the UHR patients who later made the transition to psychosis compared to the UHR patients who did not make the transition to psychosis. Poor spatial working memory function was related to increased antisaccade errors in the UHR group. Abnormal antisaccade task performance is also present in patients at UHR for developing psychosis. Subsequent research needs to clarify if increased antisaccade error rate is predictive of a psychotic episode. In UHR patients, poor antisaccade performance may reflect working memory dysfunction.


Assuntos
Inibição Psicológica , Testes Neuropsicológicos/estatística & dados numéricos , Transtornos Psicóticos/diagnóstico , Movimentos Sacádicos/fisiologia , Percepção Visual/fisiologia , Adulto , Fatores Etários , Feminino , Humanos , Inteligência , Masculino , Transtornos da Memória/diagnóstico , Transtornos da Memória/fisiopatologia , Prognóstico , Desempenho Psicomotor/fisiologia , Transtornos Psicóticos/epidemiologia , Transtornos Psicóticos/fisiopatologia , Fatores de Risco , Esquizofrenia/diagnóstico , Esquizofrenia/fisiopatologia , Análise e Desempenho de Tarefas
15.
Ann Biomed Eng ; 45(10): 2423-2436, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28726022

RESUMO

This proof-of-principle study describes the methodology and explores and demonstrates the applicability of a system, existing of miniature inertial sensors on the hand and a separate force sensor, to objectively quantify hand motor symptoms in patients with Parkinson's disease (PD) in a clinical setting (off- and on-medication condition). Four PD patients were measured in off- and on- dopaminergic medication condition. Finger tapping, rapid hand opening/closing, hand pro/supination, tremor during rest, mental task and kinetic task, and wrist rigidity movements were measured with the system (called the PowerGlove). To demonstrate applicability, various outcome parameters of measured hand motor symptoms of the patients in off- vs. on-medication condition are presented. The methodology described and results presented show applicability of the PowerGlove in a clinical research setting, to objectively quantify hand bradykinesia, tremor and rigidity in PD patients, using a single system. The PowerGlove measured a difference in off- vs. on-medication condition in all tasks in the presented patients with most of its outcome parameters. Further study into the validity and reliability of the outcome parameters is required in a larger cohort of patients, to arrive at an optimal set of parameters that can assist in clinical evaluation and decision-making.


Assuntos
Dedos , Força da Mão , Hipocinesia , Doença de Parkinson , Tremor , Adulto , Feminino , Dedos/patologia , Dedos/fisiopatologia , Humanos , Hipocinesia/diagnóstico , Hipocinesia/patologia , Hipocinesia/fisiopatologia , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/diagnóstico , Doença de Parkinson/patologia , Doença de Parkinson/fisiopatologia , Estudo de Prova de Conceito , Tremor/diagnóstico , Tremor/patologia , Tremor/fisiopatologia
16.
J Neural Eng ; 13(6): 066009, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27739406

RESUMO

OBJECTIVE: The correspondence between the anatomical STN and the STN observed in T2-weighted MRI images used for deep brain stimulation (DBS) targeting remains unclear. Using a new method, we compared the STN borders seen on MRI images with those estimated by intraoperative microelectrode recordings (MER). APPROACH: We developed a method to automatically generate a detailed estimation of STN shape and the location of its borders, based on multiple-channel MER measurements. In 33 STNs of 19 Parkinson patients, we quantitatively compared the dorsal and lateral borders of this MER-based STN model with the STN borders visualized by 1.5 T (n = 14), 3.0 T (n = 10) and 7.0 T (n = 9) T2-weighted MRI. MAIN RESULTS: The dorsal border was identified more dorsally on coronal T2 MRI than by the MER-based STN model, with a significant difference in the 3.0 T (range 0.97-1.19 mm) and 7.0 T (range 1.23-1.25 mm) groups. The lateral border was significantly more medial on 1.5 T (mean: 1.97 mm) and 3.0 T (mean: 2.49 mm) MRI than in the MER-based STN; a difference that was not found in the 7.0 T group. SIGNIFICANCE: The STN extends further in the dorsal direction on coronal T2 MRI images than is measured by MER. Increasing MRI field strength to 3.0 T or 7.0 T yields similar discrepancies between MER and MRI at the dorsal STN border. In contrast, increasing MRI field strength to 7.0 T may be useful for identification of the lateral STN border and thereby improve DBS targeting.


Assuntos
Estimulação Encefálica Profunda/métodos , Microeletrodos , Núcleo Subtalâmico/patologia , Idoso , Algoritmos , Automação , Estimulação Encefálica Profunda/instrumentação , Campos Eletromagnéticos , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Procedimentos Neurocirúrgicos , Doença de Parkinson/patologia , Doença de Parkinson/fisiopatologia , Doença de Parkinson/cirurgia , Núcleo Subtalâmico/fisiopatologia , Núcleo Subtalâmico/cirurgia
17.
Magn Reson Imaging ; 34(6): 795-802, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26968144

RESUMO

Dedicated pairs of isometric wrist flexion tasks, with and without visual feedback of the exerted torque, were designed to target activation of the CBL and BG in healthy subjects during functional magnetic resonance imaging (fMRI). Selective activation of the cerebellum (CBL) and basal ganglia (BG), often implicated in movement disorders such as tremor and dystonia, may help identify pathological changes and expedite diagnosis. A prototyped MR-compatible wrist torque measurement device, free of magnetic and conductive materials, allowed safe execution of tasks during fMRI without causing artifacts. A significant increase of activity in CBL and BG was found in healthy volunteers during a constant torque task with visual feedback compared to a constant torque task without visual feedback. This study shows that specific pairs of motor tasks using MR-compatible equipment at the wrist allow for targeted activation of CBL and BG, paving a new way for research into the pathophysiology of movement disorders.


Assuntos
Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Contração Isométrica/fisiologia , Imageamento por Ressonância Magnética/métodos , Articulação do Punho/diagnóstico por imagem , Articulação do Punho/fisiologia , Adulto , Feminino , Humanos , Magnetismo , Masculino , Movimento/fisiologia , Amplitude de Movimento Articular/fisiologia , Valores de Referência , Torque
18.
Neurosurgery ; 78(3): 353-60, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26600278

RESUMO

BACKGROUND: Susceptibility-weighted imaging (SWI) offers significantly improved visibility of the subthalamic nucleus (STN) compared with traditional T2-weighted imaging. However, it is unknown whether the representation of the nucleus on SWI corresponds to the neurophysiological location of the STN. OBJECTIVE: To determine the correlation between the intraoperative electrophysiological activity of the STN and the representation of the nucleus on different magnetic resonance imaging (MRI) sequences used for deep brain stimulation target planning. METHODS: At stereotactic target depth, microelectrode recordings (MERs) of typical STN neuronal activity were mapped on 3 different preoperative MRI sequences: 1.5-T SWI, 1.5-T T2-weighted, and 3-T T2-weighted MRI. For each MRI sequence, it was determined whether the MER signal was situated inside or outside the contour of the STN. RESULTS: A total of 196 MER tracks in 34 patients were evaluated. In 165 tracks (84%), typical electrophysiological STN activity was measured. MER activity was situated more consistently inside hypointense STN contour representation on 1.5- and 3-T T2-weighted images compared with SWI (99% and 100% vs 79%, respectively). The 21% incongruence of electrophysiological STN activity outside the STN contour on SWI was seen almost exclusively in the anterior and lateral microelectrode channels. CONCLUSION: STN representation on SWI does not correspond to electrophysiological STN borders. SWI does not correctly display the lateral part of the STN. When aiming to target the superolateral sensorimotor part of the STN during deep brain stimulation surgery, SWI does not offer an advantage but a disadvantage compared with conventional T2. Future research is needed to determine whether these findings may also apply for high-field SWI.


Assuntos
Mapeamento Encefálico/métodos , Estimulação Encefálica Profunda/métodos , Monitorização Neurofisiológica Intraoperatória/métodos , Imageamento por Ressonância Magnética/métodos , Núcleo Subtalâmico/fisiologia , Adulto , Idoso , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Pessoa de Meia-Idade
19.
J Neural Eng ; 12(4): 046003, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26020096

RESUMO

OBJECTIVE: The clinical effects of deep brain stimulation (DBS) of the subthalamic nucleus (STN-DBS) as a treatment for Parkinson's disease are sensitive to the location of the DBS lead within the STN. New high density (HD) lead designs have been created which are hypothesized to provide additional degrees of freedom in shaping the stimulating electric field. The objective of this study is to compare the performances of a new HD lead with a conventional cylindrical contact (CC) lead. APPROACH: A computational model, consisting of a finite element electric field model combined with multi-compartment neuron and axon models representing different neural populations in the subthalamic region, was used to evaluate the two leads. We compared ring-mode and steering-mode stimulation with the HD lead to single contact stimulation with the CC lead. These stimulation modes were tested for the lead: (1) positioned in the centroid of the STN, (2) shifted 1 mm towards the internal capsule (IC), and (3) shifted 2 mm towards the IC. Under these conditions, we quantified the number of STN neurons that were activated without activating IC fibers, which are known to cause side-effects. MAIN RESULTS: The modeling results show that the HD lead is able to mimic the stimulation effect of the CC lead. Additionally, in steering-mode stimulation there was a significant increase of activated STN neurons compared to the CC mode. SIGNIFICANCE: From the model simulations we conclude that the HD lead in steering-mode with optimized stimulation parameter selection can stimulate more STN cells. Next, the clinical impact of the increased number of activated STN cells should be tested and balanced across the increased complexity of identifying the optimized stimulation parameter settings for the HD lead.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Eletrodos Implantados , Modelos Neurológicos , Rede Nervosa/fisiologia , Neurônios/fisiologia , Núcleo Subtalâmico/fisiologia , Potenciais de Ação/fisiologia , Simulação por Computador , Desenho Assistido por Computador , Condutividade Elétrica , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos
20.
Psychophysiology ; 52(4): 585-93, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25376718

RESUMO

We aimed to determine profiles of information processing deficits in the pathway to first psychosis. Sixty-one subjects at ultrahigh risk (UHR) for psychosis were assessed, of whom 18 converted to a first episode of psychosis (FEP) within the follow-up period. Additionally, 47 FEP and 30 control subjects were included. Using 10 neurophysiological parameters associated with information processing, latent class analyses yielded three classes at baseline. Class membership was related to group status. Within the UHR sample, two classes were found. Transition to psychosis was nominally associated with class membership. Neurophysiological profiles were unstable over time, but associations between specific neurophysiological components at baseline and follow-up were found. We conclude that certain constellations of neurophysiological variables aid in the differentiation between controls and patients in the prodrome and after first psychosis.


Assuntos
Encéfalo/fisiopatologia , Potenciais Evocados/fisiologia , Movimentos Oculares/fisiologia , Transtornos Psicóticos/fisiopatologia , Adolescente , Adulto , Eletroencefalografia , Feminino , Humanos , Masculino , Transtornos Psicóticos/psicologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA