Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 30(26): 47093-47102, 2022 Dec 19.
Artigo em Inglês | MEDLINE | ID: mdl-36558646

RESUMO

Spectroscopy in the mid-infrared (mid-IR) wavelength range is a key technique to detect and identify chemical and biological substances. In this context, the development of integrated optics systems paves the way for the realization of compact and cost-effective sensing systems. Among the required devices, an integrated electro-optical modulator (EOM) is a key element for advanced sensing circuits exploiting dual comb spectroscopy. In this paper, we have experimentally demonstrated an integrated EOM operating in a wide wavelength range, i.e. from 5 to 9 µm at radio frequency (RF) as high as 1 GHz. The modulator exploits the variation of free carrier absorption in a Schottky diode embedded in a graded silicon germanium (SiGe) photonic waveguide.

2.
Opt Express ; 26(26): 34366-34372, 2018 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-30650859

RESUMO

Taking advantage of unique molecular absorption lines in the mid-infrared fingerprint region and of the atmosphere transparency window (3-5 µm and 8-14 µm), mid-infrared silicon photonics has attracted more research activities with a great potential for applications in different areas, including spectroscopy, remote sensing, free-space communication and many others. However, the demonstration of resonant structures operating at long-wave infrared wavelengths still remains challenging. Here, we demonstrate Bragg grating-based Fabry-Perot resonators based on Ge-rich SiGe waveguides with broadband operation in the mid-infrared. Bragg grating waveguides are investigated first at different wavelengths from 5.4 µm up to 8.4 µm, showing a rejection band up to 21 dB. Integrated Fabry-Perot resonators are then demonstrated for the first time in the 8 µm-wavelength range, showing Q-factors as high as 2200. This first demonstration of integrated mid-infrared Fabry-Perot resonators paves the way towards resonance-enhanced sensing circuits and non-linear based devices at these wavelengths.

3.
Opt Lett ; 43(20): 5021-5024, 2018 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-30320809

RESUMO

Miniaturized on-chip spectrometers covering a wide band of the mid-infrared spectrum have an immense potential for multi-target detection in high-impact applications, such as chemical sensing or environmental monitoring. Specifically, multi-aperture spatial heterodyne Fourier-transform spectrometers (SHFTS) provide high throughput and improved tolerance against fabrication errors, compared to conventional counterparts. Still, state-of-the-art implementations have only shown single-polarization operation in narrow bandwidths within the near and short infrared. Here, we demonstrate the first, to the best of our knowledge, dual-polarization ultra-wideband SHFTS working beyond 5 µm wavelength. We exploit the unique flexibility in material engineering of the graded-index germanium-rich silicon-germanium (Ge-rich SiGe) photonic platform to implement a SHFTS that can be operated in an unprecedented range of 800 cm-1, showing experimental resolution better than 15 cm-1 for both orthogonal polarizations and free spectral range of 132 cm-1, in the wavelength range between 5 and 8.5 µm.

4.
Opt Lett ; 42(17): 3482-3485, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28957068

RESUMO

This Letter explores the use of Ge-rich Si0.2Ge0.8 waveguides on graded Si1-xGex substrate for the demonstration of ultra-wideband photonic integrated circuits in the mid-infrared (mid-IR) wavelength range. We designed, fabricated, and characterized broadband Mach-Zehnder interferometers fully covering a range of 3 µm in the mid-IR band. The fabricated devices operate indistinctly in quasi-TE and quasi-TM polarizations, and have an extinction ratio higher than 10 dB over the entire operating wavelength range. The obtained results are in good correlation with theoretical predictions, while numerical simulations indicate that the device bandwidth can reach one octave with low additional losses. This Letter paves the way for further realization of mid-IR integrated spectrometers using low-index-contrast Si1-xGex waveguides with high germanium concentration.

5.
Opt Express ; 23(24): 30821-6, 2015 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-26698715

RESUMO

The integration of germanium (Ge)-rich active devices in photonic integrated circuits is challenging due to the lattice mismatch between silicon (Si) and Ge. A new Ge-rich silicon-germanium (SiGe) waveguide on graded buffer was investigated as a platform for integrated photonic circuits. At a wavelength of 1550 nm, low loss bends with radii as low as 12 µm and Multimode Interferometer beam splitter based on Ge-rich SiGe waveguide on graded buffer were designed, fabricated and characterized. A Mach Zehnder interferometer exhibiting a contrast of more than 10 dB has been demonstrated.

6.
IEEE Trans Biomed Eng ; 71(4): 1127-1138, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37889817

RESUMO

The leadless pacemaker is the most recent pacemaker concept, developed to overcome conventional pacemakers' limitations. This technology offers better comfort to the patients, lower risk from implantation, and higher reliability. However, these devices suffer from limited battery lifetime due to the extreme miniaturization required for implantation inside the heart cavities. This work proposes extending the battery lifetime by converting biomechanical heartbeat energy into electricity using an innovative electrostatic MEMS energy harvesting device. Based on theoretical models and experiments, we propose a general approach to choosing the optimal interface circuit which considers the parasitic capacitance of the circuit, as it is an imperfection that significantly affects the power performance. According to the energy consumed by the last generation commercial leadless pacemakers, the proposed MEMS solution with optimal interface circuit experimentally showed the possibility of extending the pacemaker battery lifetime by up to 44%.


Assuntos
Sistemas Microeletromecânicos , Marca-Passo Artificial , Humanos , Eletricidade Estática , Reprodutibilidade dos Testes , Desenho de Equipamento , Marca-Passo Artificial/efeitos adversos
7.
Opt Express ; 20(10): 10591-6, 2012 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-22565685

RESUMO

40 Gbit/s low-loss silicon optical modulators are demonstrated. The devices are based on the carrier depletion effect in a pipin diode to generate a good compromise between high efficiency, speed and low optical loss. The diode is embedded in a Mach-Zehnder interferometer, and a self-aligned fabrication process was used to obtain precise localization of the active p-doped region in the middle of the waveguide. Using a 4.7 mm (resp. 0.95 mm) long phase shifter, the modulator exhibits an extinction ratio of 6.6 dB (resp. 3.2 dB), simultaneously with an optical loss of 6 dB (resp. 4.5 dB) at the same operating point.


Assuntos
Interferometria/instrumentação , Silício/química , Biofísica/métodos , Gráficos por Computador , Eletrônica/instrumentação , Desenho de Equipamento , Interferometria/métodos , Luz , Dispositivos Ópticos , Óptica e Fotônica/métodos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador/instrumentação , Telecomunicações , Interface Usuário-Computador
8.
Front Chem ; 10: 868909, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35425760

RESUMO

MicroRNAs (miRNAs) are biomarkers involved in biological processes that are released by cells and found in biological fluids such as blood. The development of nucleic acid-based biosensors has significantly increased in the past 10 years because the detection of such nucleic acids can easily be applied in the field of early diagnosis. These biosensors need to be sensitive, specific, and fast in order to be effective. This work introduces a newly-built electrochemical biosensor that enables a fast detection in 30 min and, as a result of its integration in microfluidics, presents a limit of detection as low as 1 aM. The litterature concerning the specificity of electrochemical biosensors includes several studies that report one base-mismatch, with the base-mismatch located in the middle of the strand. We report an electrochemical nucleic acid biosensor integrated into a microfluidic chip, allowing for a one-base-mismatch specificity independently from the location of the mismatch in the strand. This specificity was improved using a solution of methylene blue, making it possible to discriminate a partial hybridization from a complete and complementary hybridization.

9.
Opt Express ; 19(7): 5827-32, 2011 Mar 28.
Artigo em Inglês | MEDLINE | ID: mdl-21451607

RESUMO

High speed and high extinction ratio silicon optical modulator using carrier depletion is experimentally demonstrated. The phase-shifter is a 1.8 mm-long PIPIN diode which is integrated in a Mach Zehnder interferometer. 8.1 dB Extinction Ratio at 10 Gbit/s is obtained simultaneously with optical loss as low as 6 dB.


Assuntos
Redes de Comunicação de Computadores/instrumentação , Interferometria/instrumentação , Semicondutores , Silício/química , Desenho de Equipamento , Análise de Falha de Equipamento , Micro-Ondas
10.
ACS Appl Bio Mater ; 4(2): 1307-1318, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-35014482

RESUMO

Recent evidence suggests that proinflammatory cytokines, such as tumor necrosis factor α (TNF-α), play a pivotal role in the development of inflammatory-related pathologies (covid-19, depressive disorders, sepsis, cancer, etc.,). More importantly, the development of TNF-α biosensors applied to biological fluids (e.g. sweat) could offer non-invasive solutions for the continuous monitoring of these disorders, in particular, polydimethylsiloxane (PDMS)-based biosensors. We have therefore investigated the biofunctionalization of PDMS surfaces using a silanization reaction with 3-aminopropyltriethoxysilane, for the development of a human TNF-α biosensor. The silanization conditions for 50 µm PDMS surfaces were extensively studied by using water contact angle measurements, electron dispersive X-ray and Fourier transform infrared spectroscopies, and fluorescamine detection. Evaluation of the wettability of the silanized surfaces and the Si/C ratio pointed out to the optimal silanization conditions supporting the formation of a stable and reproducible aminosilane layer, necessary for further bioconjugation. An ELISA-type immunoassay was then successfully performed for the detection and quantification of human TNF-α through fluorescent microscopy, reaching a limit of detection of 0.55 µg/mL (31.6 nM). Finally, this study reports for the first time a promising method for the development of PDMS-based biosensors for the detection of TNF-α, using a quick, stable, and simple biofunctionalization process.


Assuntos
Dimetilpolisiloxanos/química , Imunoensaio/métodos , Fator de Necrose Tumoral alfa/análise , Anticorpos Imobilizados/química , Anticorpos Imobilizados/imunologia , COVID-19/metabolismo , COVID-19/patologia , COVID-19/virologia , Carbono/química , Humanos , Imunoensaio/instrumentação , Limite de Detecção , Microfluídica , Microscopia de Fluorescência , SARS-CoV-2/isolamento & purificação , Silício/química , Fator de Necrose Tumoral alfa/imunologia , Molhabilidade
11.
ACS Photonics ; 7(12): 3423-3429, 2020 Dec 16.
Artigo em Inglês | MEDLINE | ID: mdl-33365361

RESUMO

Midinfrared spectroscopy is a universal way to identify chemical and biological substances. Indeed, when interacting with a light beam, most molecules are responsible for absorption at specific wavelengths in the mid-IR spectrum, allowing to detect and quantify small traces of substances. On-chip broadband light sources in the mid-infrared are thus of significant interest for compact sensing devices. In that regard, supercontinuum generation offers a mean to efficiently perform coherent light conversion over an ultrawide spectral range, in a single and compact device. This work reports the experimental demonstration of on-chip two-octave supercontinuum generation in the mid-infrared wavelength, ranging from 3 to 13 µm (that is larger than 2500 cm-1) and covering almost the full transparency window of germanium. Such an ultrawide spectrum is achieved thanks to the unique features of Ge-rich graded SiGe waveguides, which allow second-order dispersion tailoring and low propagation losses over a wide wavelength range. The influence of the pump wavelength and power on the supercontinuum spectra has been studied. A good agreement between the numerical simulations and the experimental results is reported. Furthermore, a very high coherence is predicted in the entire spectrum. These results pave the way for wideband, coherent, and compact mid-infrared light sources by using a single device and compatible with large-scale fabrication processes.

12.
Neurophotonics ; 6(1): 015008, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30854406

RESUMO

Speckle contrast imaging allows in vivo imaging of relative blood flow changes. Multiple exposure speckle imaging (MESI) is more accurate than the standard single-exposure method since it allows separating the contribution of the static and moving scatters of the recorded speckle patterns. MESI requires experimental validation on phantoms prior to in vivo experiments to ensure the proper calibration of the system and the robustness of the model. The data analysis relies on the calculation of the speckle contrast for each exposure and a subsequent nonlinear fit to the MESI model to extract the scatterers correlation time and the relative contribution of moving scatters. We have designed two multichannel polydimethylsiloxane chips to study the influence of multiple and static scattering on the accuracy of MESI quantitation. We also propose a method based on standard C++ libraries to implement a computationally efficient analysis of the MESI data. Finally, the system was used to obtain in vivo hemodynamic data on two distinct sensory areas of the mice brain: the barrel cortex and the olfactory bulb.

13.
Opt Express ; 16(22): 17237-42, 2008 Oct 27.
Artigo em Inglês | MEDLINE | ID: mdl-18958004

RESUMO

This article describes the first demonstration of ring resonators based on vertical multiple-slot silicon nitride waveguides. The design, fabrication and measurement of multiple-slot waveguide ring resonators with several coupling distances and ring radii (70 microm, 90 microm and 110 microm) have been carried out for TE and TM polarizations at the wavelength of 1.3 microm. Quality factors of 6,100 and 16,000 have been achieved for TE and TM polarization, respectively.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA