Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Chem Zvesti ; : 1-7, 2023 Jun 14.
Artigo em Inglês | MEDLINE | ID: mdl-37362796

RESUMO

The first accelerator mass spectrometry (AMS) laboratory in the Czech Republic has been established and put into routine operation in February 2022. Here we briefly describe the facilities available, namely a 300 kV multi-isotope low-energy AMS system (MILEA) capable of determination 10Be, 14C, 26Al, 41Ca, 129I, isotopes of U, especially 236U, Pu and other actinoids, and accessories for 14C measurements, which include a gas interface system, a preparative gas chromatography system for compound-specific radiocarbon dating analysis, and an isotope-ratio mass spectrometer. The first results achieved for separation and measurement of the above radionuclides (except for 41Ca) are also reported, with the main focus on 14C measurements. A specimen breakdown of 729 graphitised samples analysed for 14C so far is presented, as well as a proof of measurement stability of the MILEA system obtained by analysis of radiocarbon standards and analytical blanks. For the other radionuclides, well proven or novel procedures for sample preparation and measurement are presented.

2.
Int J Mol Sci ; 23(24)2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36555249

RESUMO

Modeling ionizing radiation interaction with biological matter is a major scientific challenge, especially for protons that are nowadays widely used in cancer treatment. That presupposes a sound understanding of the mechanisms that take place from the early events of the induction of DNA damage. Herein, we present results of irradiation-induced complex DNA damage measurements using plasmid pBR322 along a typical Proton Treatment Plan at the MedAustron proton and carbon beam therapy facility (energy 137-198 MeV and Linear Energy Transfer (LET) range 1-9 keV/µm), by means of Agarose Gel Electrophoresis and DNA fragmentation using Atomic Force Microscopy (AFM). The induction rate Mbp-1 Gy-1 for each type of damage, single strand breaks (SSBs), double-strand breaks (DSBs), base lesions and non-DSB clusters was measured after irradiations in solutions with varying scavenging capacity containing 2-amino-2-(hydroxymethyl)propane-1,3-diol (Tris) and coumarin-3-carboxylic acid (C3CA) as scavengers. Our combined results reveal the determining role of LET and Reactive Oxygen Species (ROS) in DNA fragmentation. Furthermore, AFM used to measure apparent DNA lengths provided us with insights into the role of increasing LET in the induction of highly complex DNA damage.


Assuntos
Terapia com Prótons , Prótons , Dano ao DNA , DNA/genética , Plasmídeos/genética
3.
J Environ Radioact ; 218: 106237, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32421571

RESUMO

In order to study radiocarbon levels at a clean air location in Slovakia with no significant local anthropogenic effects, we took tree ring samples from a tree in the vicinity of Jasná recreational area in the Low Tatras region in the central part of Slovakia. There are no significant local fossil fuel emission sources, so these samples represent a regional clean air background important for 14C studies in Slovakia and Central Europe. The growth rings from the sampled tree (European spruce, Picea abies) cover the period from 1911 to 2016. The first part of the data (1911-1952) represents natural radiocarbon levels influenced by Suess effect. The following period exhibits an increase in radiocarbon levels due to atmospheric nuclear weapons tests (Δ14C maximum of 850‰ in 1964), and then a gradual decrease characterized by an exponential trend with time constant of 14.3 ± 0.5 years. The Δ14C data from Jasná was used as a reference for comparison with two previously reported modern tree ring data sets from Slovakia. This comparison showed that radiocarbon levels at both locations are lower than clean air reference values, indicating the influence of local fossil fuel emissions.


Assuntos
Picea , Monitoramento de Radiação , Árvores , Europa (Continente) , Combustíveis Fósseis , Eslováquia
4.
Radiat Prot Dosimetry ; 186(2-3): 155-158, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31803908

RESUMO

A comparison between breast cancer cell line MCF7 and human adipose-derived stem cells (ADSC) after irradiation by the same doses of megavoltage X-rays was performed. The cell growth, the induction of apoptosis and the expression of selected genes were analyzed. Irradiated MCF7 related to its control sample grows slower than ADSC and it undergoes apoptosis in much higher levels than ADSC. This was confirmed by real-time polymerase chain reaction as well, where the expression of apoptotic genes was found to be considerably higher for MCF7 than for ADSC. From the results of this project, it could be stated that MCF7 is more radiosensitive than ADSC.


Assuntos
Adipócitos/efeitos da radiação , Células MCF-7/efeitos da radiação , Tolerância a Radiação , Células-Tronco/efeitos da radiação , Apoptose/efeitos da radiação , Proliferação de Células/efeitos da radiação , Humanos
5.
Radiat Prot Dosimetry ; 186(2-3): 168-171, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31803909

RESUMO

Plasmid DNA is commonly used as a simpler substitute for a cell in studies of early effects of ionizing radiation because it allows to determine yields of primary DNA lesions. Experimental studies often employ plasmids of different lengths, in different concentrations in the aqueous solution. Influence of these parameters on the heavy-ion induced yields of primary DNA damage has been studied, using plasmids pUC19 (2686 bp), pBR322 (4361 bp) and pKLAC2 (9107 bp) in 10 and 50 ng/µl concentration. Results demonstrate the impact of plasmid length, while no significant difference was observed between the two concentrations. The uncertainty of the results is discussed.


Assuntos
Dano ao DNA/efeitos da radiação , DNA/efeitos da radiação , Plasmídeos/efeitos da radiação , Algoritmos , Antioxidantes/farmacologia , Relação Dose-Resposta à Radiação , Raios gama , Íons Pesados , Transferência Linear de Energia , Método de Monte Carlo , Polipropilenos/química , Radiação Ionizante , Incerteza
6.
Australas Phys Eng Sci Med ; 40(2): 359-368, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28321635

RESUMO

In recent years, there is an increased interest in using scanning modes in proton therapy, due to the more conformal dose distributions, thanks to the spot-weighted dose delivery. The dose rate in each spot is however much higher than the dose rate when using passive irradiation modes, which could affect the cell response. The purpose of this work was to investigate how the relative biological effectiveness changes along the spread-out Bragg peak created by protons delivered by the pencil beam scanning mode. Cell survival and micronuclei formation were investigated in four positions along the spread-out Bragg peak for various doses. Monte Carlo simulations were used to estimate the dose-averaged linear energy transfer values in the irradiation positions. The cell survival was found to decrease the deeper the sample was placed in the spread-out Bragg peak, which corresponds to the higher linear energy transfer values found using Monte Carlo simulations. The micronuclei frequencies indicate more complex cell injuries at that distal position compared to the proximal part of the spread-out Bragg peak. The relative biological effectiveness determined in this study varies significantly and systematically from 1.1, which is recommended value by the International Commission on Radiation Units, in all the studied positions. In the distal position of spread-out Bragg peak the relative biological effectiveness values were found to be 2.05 ± 0.44, 1.85 ± 0.42, 1.53 ± 0.38 for survival levels 90, 50 and 10%, respectively.


Assuntos
Prótons , Eficiência Biológica Relativa , Sobrevivência Celular/efeitos da radiação , Simulação por Computador , Relação Dose-Resposta à Radiação , Humanos , Recém-Nascido , Transferência Linear de Energia , Testes para Micronúcleos , Radiometria
7.
Radiat Prot Dosimetry ; 164(4): 484-8, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979739

RESUMO

Aircrew members and passengers are exposed to increased rates of cosmic radiation on-board commercial jet aircraft. The annual effective doses of crew members often exceed limits for public, thus it is recommended to monitor them. In general, the doses are estimated via various computer codes and in some countries also verified by measurements. This paper describes a comparison of three cosmic rays detectors, namely of the (a) HAWK Tissue Equivalent Proportional Counter; (b) Liulin semiconductor energy deposit spectrometer and (c) TIMEPIX silicon semiconductor pixel detector, exposed to radiation fields on-board commercial Czech Airlines company jet aircraft. Measurements were performed during passenger flights from Prague to Madrid, Oslo, Tbilisi, Yekaterinburg and Almaty, and back in July and August 2011. For all flights, energy deposit spectra and absorbed doses are presented. Measured absorbed dose and dose equivalent are compared with the EPCARD code calculations. Finally, the advantages and disadvantages of all detectors are discussed.


Assuntos
Aeronaves/instrumentação , Radiação Cósmica , Exposição Ocupacional/análise , Monitoramento de Radiação/instrumentação , Absorção de Radiação , Desenho de Equipamento , Humanos , Exposição Ocupacional/normas , Exposição à Radiação , Semicondutores , Atividade Solar
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA