1.
N Engl J Med ; 388(11): 991-1001, 2023 Mar 16.
Artigo em Inglês | MEDLINE | ID: mdl-36920756

RESUMO

BACKGROUND: Closed-loop control systems of insulin delivery may improve glycemic outcomes in young children with type 1 diabetes. The efficacy and safety of initiating a closed-loop system virtually are unclear. METHODS: In this 13-week, multicenter trial, we randomly assigned, in a 2:1 ratio, children who were at least 2 years of age but younger than 6 years of age who had type 1 diabetes to receive treatment with a closed-loop system of insulin delivery or standard care that included either an insulin pump or multiple daily injections of insulin plus a continuous glucose monitor. The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. Secondary outcomes included the percentage of time that the glucose level was above 250 mg per deciliter or below 70 mg per deciliter, the mean glucose level, the glycated hemoglobin level, and safety outcomes. RESULTS: A total of 102 children underwent randomization (68 to the closed-loop group and 34 to the standard-care group); the glycated hemoglobin levels at baseline ranged from 5.2 to 11.5%. Initiation of the closed-loop system was virtual in 55 patients (81%). The mean (±SD) percentage of time that the glucose level was within the target range increased from 56.7±18.0% at baseline to 69.3±11.1% during the 13-week follow-up period in the closed-loop group and from 54.9±14.7% to 55.9±12.6% in the standard-care group (mean adjusted difference, 12.4 percentage points [equivalent to approximately 3 hours per day]; 95% confidence interval, 9.5 to 15.3; P<0.001). We observed similar treatment effects (favoring the closed-loop system) on the percentage of time that the glucose level was above 250 mg per deciliter, on the mean glucose level, and on the glycated hemoglobin level, with no significant between-group difference in the percentage of time that the glucose level was below 70 mg per deciliter. There were two cases of severe hypoglycemia in the closed-loop group and one case in the standard-care group. One case of diabetic ketoacidosis occurred in the closed-loop group. CONCLUSIONS: In this trial involving young children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with a closed-loop system than with standard care. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases; PEDAP ClinicalTrials.gov number, NCT04796779.).


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Criança , Pré-Escolar , Humanos , Glicemia/análise , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hemoglobinas Glicadas/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/efeitos adversos , Hipoglicemiantes/uso terapêutico , Insulina/administração & dosagem , Insulina/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina/efeitos adversos
2.
Diabetologia ; 2024 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-38995398

RESUMO

Children with type 1 diabetes and their caregivers face numerous challenges navigating the unpredictability of this complex disease. Although the burden of managing diabetes remains significant, new technology has eased some of the load and allowed children with type 1 diabetes to achieve tighter glycaemic management without fear of excess hypoglycaemia. Continuous glucose monitor use alone improves outcomes and is considered standard of care for paediatric type 1 diabetes management. Similarly, automated insulin delivery (AID) systems have proven to be safe and effective for children as young as 2 years of age. AID use improves not only blood glucose levels but also quality of life for children with type 1 diabetes and their caregivers and should be strongly considered for all youth with type 1 diabetes if available and affordable. Here, we review key data on the use of diabetes technology in the paediatric population and discuss management issues unique to children and adolescents.

3.
N Engl J Med ; 383(9): 836-845, 2020 08 27.
Artigo em Inglês | MEDLINE | ID: mdl-32846062

RESUMO

BACKGROUND: A closed-loop system of insulin delivery (also called an artificial pancreas) may improve glycemic outcomes in children with type 1 diabetes. METHODS: In a 16-week, multicenter, randomized, open-label, parallel-group trial, we assigned, in a 3:1 ratio, children 6 to 13 years of age who had type 1 diabetes to receive treatment with the use of either a closed-loop system of insulin delivery (closed-loop group) or a sensor-augmented insulin pump (control group). The primary outcome was the percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter, as measured by continuous glucose monitoring. RESULTS: A total of 101 children underwent randomization (78 to the closed-loop group and 23 to the control group); the glycated hemoglobin levels at baseline ranged from 5.7 to 10.1%. The mean (±SD) percentage of time that the glucose level was in the target range of 70 to 180 mg per deciliter increased from 53±17% at baseline to 67±10% (the mean over 16 weeks of treatment) in the closed-loop group and from 51±16% to 55±13% in the control group (mean adjusted difference, 11 percentage points [equivalent to 2.6 hours per day]; 95% confidence interval, 7 to 14; P<0.001). In both groups, the median percentage of time that the glucose level was below 70 mg per deciliter was low (1.6% in the closed-loop group and 1.8% in the control group). In the closed-loop group, the median percentage of time that the system was in the closed-loop mode was 93% (interquartile range, 91 to 95). No episodes of diabetic ketoacidosis or severe hypoglycemia occurred in either group. CONCLUSIONS: In this 16-week trial involving children with type 1 diabetes, the glucose level was in the target range for a greater percentage of time with the use of a closed-loop system than with the use of a sensor-augmented insulin pump. (Funded by Tandem Diabetes Care and the National Institute of Diabetes and Digestive and Kidney Diseases; ClinicalTrials.gov number, NCT03844789.).


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Bombas de Infusão Implantáveis , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Adolescente , Glicemia/análise , Criança , Diabetes Mellitus Tipo 1/sangue , Cetoacidose Diabética/etiologia , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/induzido quimicamente , Hipoglicemiantes/efeitos adversos , Injeções Subcutâneas , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial
4.
Diabetes Obes Metab ; 24(3): 511-521, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34816597

RESUMO

AIM: To assess the safety and efficacy of hybrid closed-loop (HCL) insulin delivery 24/7 versus only evening and night (E/N), and on extended 24/7 use, in free-living children with type 1 diabetes. MATERIALS AND METHODS: Prepubertal children (n = 122; 49 females/73 males; age, 8.6 ± 1.6 years; diabetes duration, 5.2 ± 2.3 years; insulin pump use, 4.6 ± 2.5 years; HbA1c 7.7% ± 0.7%/61 ± 5 mmol/mol) from four centres were randomized for 24/7 versus E/N activation of the Tandem Control-IQ system for 18 weeks. Afterwards, all children used the activated system 24/7 for 18 more weeks. The primary outcome was the percentage of time spent in the 70-180 mg/dL glucose range (TIR). RESULTS: HCL was active 94.1% and 51.1% of the time in the 24/7 and E/N modes, respectively. TIR from baseline increased more in the 24/7 versus the E/N mode (52.9% ± 9.5% to 67.3% ± 5.6% [+14.4%, 95% CI 12.4%-16.7%] vs. 55.1% ± 10.8% to 64.7% ± 7.0% [+9.6%, 95% CI 7.4%-11.6%]; P = .001). Mean percentage time below range was similarly reduced, from 4.2% and 4.6% to 2.7%, and the mean percentage time above range decreased more in the 24/7 mode (41.9% to 30.0% [-11.9%, 95% CI 9.7%-14.6%] vs. 39.8% to 32.6% [-7.2%, 95% CI 5.0%-9.9%]; P = .007). TIR increased through the whole range of baseline levels and always more with 24/7 use. The results were maintained during the extension phase in those initially on 24/7 use and improved in those with initial E/N use up to those with 24/7 use. Neither ketoacidosis nor severe hypoglycaemia occurred. CONCLUSIONS: The current study shows the safety and efficacy of the Tandem Control-IQ system in free-living children with type 1 diabetes for both E/N and 24/7 use; 24/7 use shows better outcomes, sustained for up to 36 weeks with no safety issues.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/tratamento farmacológico , Feminino , Humanos , Hipoglicemiantes/efeitos adversos , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Masculino
6.
Diabetes Obes Metab ; 21(1): 183-187, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30047223

RESUMO

This randomized control trial investigated glucose control with closed-loop (CL) versus threshold-low-glucose-suspend (TLGS) insulin pump delivery in pre-pubertal children with type 1 diabetes in supervised hotel conditions. The patients [n = 24, age range: 7-12, HbA1c: 7.5 ± 0.5% (58 ± 5 mmol/mol)] and their parents were admitted twice at a 3-week interval. CL control to range or TLGS set at 3.9 mmoL/L were assessed for 48 hour in randomized order. Admissions included three meals and one snack, and physical exercise. Meal boluses followed individual insulin/carb ratios. While overnight (22:00-08:00) per cent continuous glucose monitoring (CGM) time below 3.9 mmol/L (primary outcome) was similar, time in ranges 3.9 to 10.0 and 3.9 to 7.8 mmoL/L and mean CGM were all significantly improved with CL (P < 0.001). These results were confirmed over the whole 48 hour. Disconnections between devices and limited accuracy of glucose sensors in the hypoglycaemic range appeared as limiting factors for optimal control. CL mode was well accepted while fear of hypoglycaemia was unchanged. CL did not minimize nocturnal hypoglycaemia exposure but improved time in target range compared to TLGS. Although safe and well-accepted, CL systems would benefit from more integrated devices.


Assuntos
Algoritmos , Glicemia/efeitos dos fármacos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/tratamento farmacológico , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Glicemia/análise , Criança , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Humanos , Hipoglicemia/prevenção & controle , Hipoglicemiantes/farmacologia , Hipoglicemiantes/uso terapêutico
7.
Pediatr Diabetes ; 20(6): 759-768, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31099946

RESUMO

OBJECTIVE: Artificial pancreas (AP) systems have been shown to improve glycemic control throughout the day and night in adults, adolescents, and children. However, AP testing remains limited during intense and prolonged exercise in adolescents and children. We present the performance of the Tandem Control-IQ AP system in adolescents and children during a winter ski camp study, where high altitude, low temperature, prolonged intense activity, and stress challenged glycemic control. METHODS: In a randomized controlled trial, 24 adolescents (ages 13-18 years) and 24 school-aged children (6-12 years) with Type 1 diabetes (T1D) participated in a 48 hours ski camp (∼5 hours skiing/day) at three sites: Wintergreen, VA; Kirkwood, and Breckenridge, CO. Study participants were randomized 1:1 at each site. The control group used remote monitored sensor-augmented pump (RM-SAP), and the experimental group used the t: slim X2 with Control-IQ Technology AP system. All subjects were remotely monitored 24 hours per day by study staff. RESULTS: The Control-IQ system improved percent time within range (70-180 mg/dL) over the entire camp duration: 66.4 ± 16.4 vs 53.9 ± 24.8%; P = .01 in both children and adolescents. The AP system was associated with a significantly lower average glucose based on continuous glucose monitor data: 161 ± 29.9 vs 176.8 ± 36.5 mg/dL; P = .023. There were no differences between groups for hypoglycemia exposure or carbohydrate interventions. There were no adverse events. CONCLUSIONS: The use of the Control-IQ AP improved glycemic control and safely reduced exposure to hyperglycemia relative to RM-SAP in pediatric patients with T1D during prolonged intensive winter sport activities.


Assuntos
Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/tratamento farmacológico , Pâncreas Artificial , Esqui/fisiologia , Esportes/fisiologia , Adolescente , Glicemia/efeitos dos fármacos , Glicemia/metabolismo , Automonitorização da Glicemia/efeitos adversos , Automonitorização da Glicemia/instrumentação , Automonitorização da Glicemia/métodos , Criança , Temperatura Baixa , Estudos Cross-Over , Desenho de Equipamento , Feminino , Humanos , Hiperglicemia/etiologia , Hipoglicemia/etiologia , Insulina/administração & dosagem , Insulina/efeitos adversos , Sistemas de Infusão de Insulina/efeitos adversos , Masculino , Pâncreas Artificial/efeitos adversos , Estações do Ano
8.
Sensors (Basel) ; 19(24)2019 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-31817678

RESUMO

Objective: Suboptimal insulin dosing in type 1 diabetes (T1D) is frequently associated with time-varying insulin requirements driven by various psycho-behavioral and physiological factors influencing insulin sensitivity (IS). Among these, physical activity has been widely recognized as a trigger of altered IS both during and following the exercise effort, but limited indication is available for the management of structured and (even more) unstructured activity in T1D. In this work, we present two methods to inform insulin dosing with biosignals from wearable sensors to improve glycemic control in individuals with T1D. Research Design and Methods: Continuous glucose monitors (CGM) and activity trackers are leveraged by the methods. The first method uses CGM records to estimate IS in real time and adjust the insulin dose according to a person's insulin needs; the second method uses step count data to inform the bolus calculation with the residual glucose-lowering effects of recently performed (structured or unstructured) physical activity. The methods were tested in silico within the University of Virginia/Padova T1D Simulator. A standard bolus calculator and the proposed "smart" systems were deployed in the control of one meal in presence of increased/decreased IS (Study 1) and following a 1-hour exercise bout (Study 2). Postprandial glycemic control was assessed in terms of time spent in different glycemic ranges and low/high blood glucose indices (LBGI/HBGI), and compared between the dosing strategies. Results: In Study 1, the CGM-informed system allowed to reduce exposure to hypoglycemia in presence of increased IS (percent time < 70 mg/dL: 6.1% versus 9.9%; LBGI: 1.9 versus 3.2) and exposure to hyperglycemia in presence of decreased IS (percent time > 180 mg/dL: 14.6% versus 18.3%; HBGI: 3.0 versus 3.9), tending toward optimal control. In Study 2, the step count-informed system allowed to reduce hypoglycemia (percent time < 70 mg/dL: 3.9% versus 13.4%; LBGI: 1.7 versus 3.2) at the cost of a minor increase in exposure to hyperglycemia (percent time > 180 mg/dL: 11.9% versus 7.5%; HBGI: 2.4 versus 1.5). Conclusions: We presented and validated in silico two methods for the smart dosing of prandial insulin in T1D. If seen within an ensemble, the two algorithms provide alternatives to individuals with T1D for improving insulin dosing accommodating a large variety of treatment options. Future work will be devoted to test the safety and efficacy of the methods in free-living conditions.


Assuntos
Glicemia/análise , Diabetes Mellitus Tipo 1/sangue , Hipoglicemiantes/administração & dosagem , Sistemas de Infusão de Insulina , Insulina/administração & dosagem , Automonitorização da Glicemia , Diabetes Mellitus Tipo 1/tratamento farmacológico , Exercício Físico , Humanos
9.
J Process Control ; 80: 202-210, 2019 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32831483

RESUMO

This paper presents an individualized Ensemble Model Predictive Control (EnMPC) algorithm for blood glucose (BG) stabilization and hypoglycemia prevention in people with type 1 diabetes (T1D) who exercise regularly. The EnMPC formulation can be regarded as a simplified multi-stage MPC allowing for the consideration of N en scenarios gathered from the patient's recent behavior. The patient's physical activity behavior is characterized by an exercise-specific input signal derived from the deconvolution of the patient's continuous glucose monitor (CGM), accounting for known inputs such as meal, and insulin pump records. The EnMPC controller was tested in a cohort of in silico patients with representative inter-subject and intra-subject variability from the FDA-accepted UVA/Padova simulation platform. Results show a significant improvement on hypoglycemia prevention after 30 min of mild to moderate exercise in comparison to a similarly tuned baseline controller (rMPC); with a reduction in hypoglycemia occurrences (< 70 mg/dL), from 3.08% ± 3.55 with rMPC to 0.78% ± 2.04 with EnMPC (P < 0.05).

11.
Arterioscler Thromb Vasc Biol ; 37(12): 2291-2300, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29074590

RESUMO

OBJECTIVE: Ischemia caused by narrowing of femoral artery is a major cause of peripheral arterial disease and morbidity affecting patients with diabetes mellitus. We have previously reported that the inhibition of the angiogenic response to VEGF (vascular endothelial growth factor) in diabetic mice was associated with the increased expression of SHP-1 (SH2 domain-containing phosphatase 1), a protein that can be activated by the AT2 (angiotensin II type 2) receptor. Deletion of AT2 receptor has been shown to promote angiogenesis within the ischemic muscle. However, the relative impact of AT2 receptor in diabetic condition remains unknown. APPROACH AND RESULTS: Nondiabetic and diabetic AT2 null (Atgr2-/Y) mice underwent femoral artery ligation after 2 months of diabetes mellitus. Blood perfusion was measured every week ≤4 weeks post-surgery. Expression of the VEGF, SHP-1, and renin-angiotensin pathways was evaluated. Blood flow in the ischemic muscle of diabetic Atgr2-/Y mice recovered faster and ≤80% after 4 weeks compared with 51% recovery in diabetic control littermates. Diabetic Atgr2-/Y had reduced apoptotic endothelial cells and elevated small vessel formation compared with diabetic Atgr2+/Y mice, as well as increased SHP-1 expression and reduced VEGF receptor activity. In endothelial cells, high glucose levels and AT2 agonist treatment did not change SHP-1, VEGF, and VEGF receptor expression. However, the activity of SHP-1 and its association with the VEGF receptors were increased, causing inhibition of the VEGF action in endothelial cell proliferation and migration. CONCLUSIONS: Our results suggest that the deletion of AT2 receptor reduced SHP-1 activity and restored VEGF actions, leading to an increased blood flow reperfusion after ischemia in diabetes mellitus.


Assuntos
Diabetes Mellitus/metabolismo , Angiopatias Diabéticas/metabolismo , Isquemia/metabolismo , Músculo Esquelético/irrigação sanguínea , Neovascularização Fisiológica , Proteína Tirosina Fosfatase não Receptora Tipo 6/metabolismo , Receptor Tipo 2 de Angiotensina/deficiência , Fator A de Crescimento do Endotélio Vascular/metabolismo , Animais , Glicemia/metabolismo , Bovinos , Movimento Celular , Proliferação de Células , Células Cultivadas , Diabetes Mellitus/genética , Diabetes Mellitus/fisiopatologia , Angiopatias Diabéticas/genética , Angiopatias Diabéticas/fisiopatologia , Modelos Animais de Doenças , Células Endoteliais/metabolismo , Deleção de Genes , Genótipo , Membro Posterior , Isquemia/genética , Isquemia/fisiopatologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Fenótipo , Receptor Tipo 2 de Angiotensina/genética , Receptores de Fatores de Crescimento do Endotélio Vascular/metabolismo , Recuperação de Função Fisiológica , Fluxo Sanguíneo Regional , Sistema Renina-Angiotensina , Transdução de Sinais , Fatores de Tempo
13.
Pediatr Diabetes ; 18(7): 540-546, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27734563

RESUMO

OBJECTIVE: To evaluate the safety and performance of using a heart rate (HR) monitor to inform an artificial pancreas (AP) system during exercise among adolescents with type 1 diabetes (T1D). MATERIALS AND METHODS: In a randomized, cross-over trial, adolescents with T1D age 13 - 18 years were enrolled to receive on separate days either the unmodified UVa AP (stdAP) or an AP system connected to a portable HR monitor (AP-HR) that triggered an exercise algorithm for blood glucose (BG) control. During admissions participants underwent a structured exercise regimen. Hypoglycemic events and CGM tracings were compared between the two admissions, during exercise and for the full 24-hour period. RESULTS: Eighteen participants completed the trial. While number of hypoglycemic events during exercise and rest was not different between visits (0.39 AP-HR vs 0.50 stdAP), time below 70 mg dL -1 was lower on AP-HR compared to stdAP, 0.5±2.1% vs 7.4±12.5% (P = 0.028). Time with BG within 70-180 mg dL -1 was higher for the AP-HR admission vs stdAP during the exercise portion and overall (96% vs 87%, and 77% vs 74%), but these did not reach statistical significance (P = 0.075 and P = 0.366). CONCLUSIONS: Heart rate signals can safely and efficaciously be integrated in a wireless AP system to inform of physical activity. While exercise contributes to hypoglycemia among adolescents, even when using an AP system, informing the system of exercise via a HR monitor improved time <70 mg dL -1 . Nonetheless, it did not significantly reduce the total number of hypoglycemic events, which were low in both groups.


Assuntos
Diabetes Mellitus Tipo 1/terapia , Exercício Físico , Frequência Cardíaca , Hiperglicemia/prevenção & controle , Hipoglicemia/prevenção & controle , Monitorização Ambulatorial , Pâncreas Artificial , Adolescente , Algoritmos , Glicemia/análise , Terapia Combinada , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Teste de Esforço , Feminino , Hemoglobinas Glicadas/análise , Humanos , Hipoglicemia/epidemiologia , Hipoglicemia/etiologia , Hipoglicemia/fisiopatologia , Masculino , Monitorização Ambulatorial/efeitos adversos , Pâncreas Artificial/efeitos adversos , Risco , Índice de Gravidade de Doença , Virginia/epidemiologia , Tecnologia sem Fio
14.
PLoS Genet ; 10(5): e1004363, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24809820

RESUMO

Mollicutes is a class of parasitic bacteria that have evolved from a common Firmicutes ancestor mostly by massive genome reduction. With genomes under 1 Mbp in size, most Mollicutes species retain the capacity to replicate and grow autonomously. The major goal of this work was to identify the minimal set of proteins that can sustain ribosome biogenesis and translation of the genetic code in these bacteria. Using the experimentally validated genes from the model bacteria Escherichia coli and Bacillus subtilis as input, genes encoding proteins of the core translation machinery were predicted in 39 distinct Mollicutes species, 33 of which are culturable. The set of 260 input genes encodes proteins involved in ribosome biogenesis, tRNA maturation and aminoacylation, as well as proteins cofactors required for mRNA translation and RNA decay. A core set of 104 of these proteins is found in all species analyzed. Genes encoding proteins involved in post-translational modifications of ribosomal proteins and translation cofactors, post-transcriptional modifications of t+rRNA, in ribosome assembly and RNA degradation are the most frequently lost. As expected, genes coding for aminoacyl-tRNA synthetases, ribosomal proteins and initiation, elongation and termination factors are the most persistent (i.e. conserved in a majority of genomes). Enzymes introducing nucleotides modifications in the anticodon loop of tRNA, in helix 44 of 16S rRNA and in helices 69 and 80 of 23S rRNA, all essential for decoding and facilitating peptidyl transfer, are maintained in all species. Reconstruction of genome evolution in Mollicutes revealed that, beside many gene losses, occasional gains by horizontal gene transfer also occurred. This analysis not only showed that slightly different solutions for preserving a functional, albeit minimal, protein synthetizing machinery have emerged in these successive rounds of reductive evolution but also has broad implications in guiding the reconstruction of a minimal cell by synthetic biology approaches.


Assuntos
Evolução Biológica , Biossíntese de Proteínas , Tenericutes/genética , Genes Bacterianos
15.
Pediatr Diabetes ; 17(1): 28-35, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25348683

RESUMO

OBJECTIVE: The objective of this study was to evaluate the safety and performance of the artificial pancreas (AP) in adolescents with type 1 diabetes (T1D) following insulin omission for food. RESEARCH DESIGN AND METHODS: In a randomized, cross-over trial, adolescents with T1D aged 13-18 yr were enrolled in a randomized, cross-over trial. On separate days, received either usual care (UC) through their home insulin pump or used an AP system (Diabetes Assistant platform, continuous glucose monitor, and insulin pump). Approximately 1 h after admission, participants in both groups received an unannounced snack of 30 g carbohydrate, and 4 h later they received an 80 g lunch, for which both groups only received 75% of the calculated insulin dose to cover carbohydrates. On the UC day (but not the AP day), they received their full high blood glucose (BG) correction factor at lunch. Each admission lasted approximately 8 h. RESULTS: A total of 16 participants completed the trial. On the AP day (compared to UC), mean BG was lower (197 ± 10 vs. 235 ± 14 mg/dL) and time in range 70-180 mg/dL was higher (43% ± 7 vs. 19% ± 7) (both p < 0.05) overall; these results held in the time following the snack and meal (also p < 0.05). During the trial, there were no differences between groups in the rate of hypoglycemia <70 mg/dL. CONCLUSIONS: The AP provided improvements in short-term glycemic control without increases in hypoglycemia following missed insulin for food in adolescents. Thus, the AP partly compensates for missed insulin boluses for food, a common occurrence in adolescent diabetes care. Further testing is needed in longer-term settings.


Assuntos
Glicemia/metabolismo , Diabetes Mellitus Tipo 1/terapia , Refeições , Pâncreas Artificial/estatística & dados numéricos , Adolescente , Estudos Cross-Over , Diabetes Mellitus Tipo 1/sangue , Feminino , Humanos , Masculino , Período Pós-Prandial , Lanches , Resultado do Tratamento
16.
J Diabetes Sci Technol ; 18(2): 318-323, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-37966051

RESUMO

BACKGROUND: With automated insulin delivery (AID) systems becoming widely adopted in the management of type 1 diabetes, we have seen an increase in occurrences of rebound hypoglycemia or generated hypoglycemia induced by the controller's response to rapid glucose rises following rescue carbohydrates. Furthermore, as AID systems aim to enable complete automation of prandial control, algorithms are designed to react even more strongly to glycemic rises. This work introduces a rebound hypoglycemia prevention layer (HypoSafe) that can be easily integrated into any AID system. METHODS: HypoSafe constrains the maximum permissible insulin delivery dose based on the minimum glucose reading from the previous hour and the current glucose level. To demonstrate its efficacy, we integrated HypoSafe into the latest University of Virginia (UVA) AID system and simulated two scenarios using the 100-adult cohort of the UVA/Padova T1D simulator: a nominal case including three unannounced meals, and another case where hypoglycemia was purposely induced by an overestimated manual bolus. RESULTS: In both simulation scenarios, rebound hypoglycemia events were reduced with HypoSafe (nominal: from 39 to 0, hypo-induced: from 55 to 7) by attenuating the commanded basal (nominal: 0.27U vs. 0.04U, hypo-induced: 0.27U vs. 0.03U) and bolus (nominal: 1.02U vs. 0.05U, hypo-induced: 0.43U vs. 0.02U) within the 30-minute interval after treating a hypoglycemia event. No clinically significant changes resulted for time in the range of 70 to 180 mg/dL or above 180 mg/dL. CONCLUSION: HypoSafe was shown to be effective in reducing rebound hypoglycemia events without affecting achieved time in range when combined with an advanced AID system.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pâncreas Artificial , Adulto , Humanos , Hipoglicemiantes/efeitos adversos , Pâncreas Artificial/efeitos adversos , Glicemia , Automonitorização da Glicemia/métodos , Sistemas de Infusão de Insulina/efeitos adversos , Hipoglicemia/induzido quimicamente , Diabetes Mellitus Tipo 1/tratamento farmacológico , Insulina/efeitos adversos , Glucose/efeitos adversos
17.
Artigo em Inglês | MEDLINE | ID: mdl-38662426

RESUMO

Background: Computer simulators of human metabolism are powerful tools to design and validate new diabetes treatments. However, these platforms are often limited in the diversity of behaviors and glycemic conditions they can reproduce. Replay methodologies leverage field-collected data to create ad hoc simulation environments representative of real-life conditions. After formal validations of our method in prior publications, we demonstrate its capacity to reproduce a recent clinical trial. Methods: Using the replay methodology, an ensemble of replay simulators was generated using data from a randomized crossover clinical trial comparing the hybrid closed loop (HCL) and fully closed loop (FCL) control modalities in automated insulin delivery (AID), creating 64 subject/modality pairs. Each virtual subject was exposed to the alternate AID modality to compare the simulated versus observed glycemic outcomes. Equivalence tests were performed for time in, below, and above range (TIR, TBR, and TAR) and high and low blood glucose indices (HBGI and LBGI) considering equivalence margins corresponding to clinical significance. Results: TIR, TAR, LBGI, and HBGI showed statistical and clinical equivalence between the original and the simulated data; TBR failed the equivalence test. For example, in the HCL mode, simulated TIR was 84.89% versus an observed 84.31% (P = 0.0170, confidence interval [CI] [-3.96, 2.79]), and for FCL mode, TIR was 76.58% versus 77.41% (P = 0.0222, CI [-2.54, 4.20]). Conclusion: Clinical trial data confirm the prior in silico validation of the UVA replay method in predicting the glycemic impact of modified insulin treatments. This in vivo demonstration justifies the application of the replay method to the personalization and adaptation of treatment strategies in people with type 1 diabetes.

18.
IEEE Rev Biomed Eng ; 17: 19-41, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37943654

RESUMO

OBJECTIVE: Artificial intelligence and machine learning are transforming many fields including medicine. In diabetes, robust biosensing technologies and automated insulin delivery therapies have created a substantial opportunity to improve health. While the number of manuscripts addressing the topic of applying machine learning to diabetes has grown in recent years, there has been a lack of consistency in the methods, metrics, and data used to train and evaluate these algorithms. This manuscript provides consensus guidelines for machine learning practitioners in the field of diabetes, including best practice recommended approaches and warnings about pitfalls to avoid. METHODS: Algorithmic approaches are reviewed and benefits of different algorithms are discussed including importance of clinical accuracy, explainability, interpretability, and personalization. We review the most common features used in machine learning applications in diabetes glucose control and provide an open-source library of functions for calculating features, as well as a framework for specifying data sets using data sheets. A review of current data sets available for training algorithms is provided as well as an online repository of data sources. SIGNIFICANCE: These consensus guidelines are designed to improve performance and translatability of new machine learning algorithms developed in the field of diabetes for engineers and data scientists.


Assuntos
Inteligência Artificial , Diabetes Mellitus , Humanos , Controle Glicêmico , Aprendizado de Máquina , Diabetes Mellitus/tratamento farmacológico , Algoritmos
19.
Diabetes Res Clin Pract ; 208: 111114, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38278493

RESUMO

OBJECTIVE: Examine patient-reported outcomes (PROs) after the use of t:slim X2 insulin pump with Control-IQ technology (CIQ) in young children with type 1 diabetes. METHODS: Children with type 1 diabetes, ages 2 to < 6 years (n = 102), were randomly assigned 2:1 to either CIQ or standard care (SC) with pump or multiple daily injections (MDI) plus continuous glucose monitoring (CGM) for 13 weeks. Both groups were offered to use CIQ for an additional 13 weeks after the randomized control trial's (RCT) completion. Guardians completed PRO questionnaires at baseline, 13-, and 26-weeks examining hypoglycemia concerns, quality of life, parenting stress, and sleep. At 26 weeks, 28 families participated in user-experience interviews. Repeated measures analyses compared PRO scores between systems used. RESULT: Comparing CIQ vs SC, responses on all 5 PRO surveys favored the CIQ group, showing that CIQ was superior to SC at 26 weeks (p values < 0.05). User-experience interviews indicated significant benefits in optimized glycemic control overall and nighttime control (28 of 28 families endorsed). All but 2/28 families noted substantial reduction in management burden resulting in less mental burden and all but 4 stated that they wanted their children to continue using CIQ. CONCLUSIONS: Families utilizing CIQ experienced glycemic benefits coupled with substantial benefits in PROs, documented in surveys and interviews. Families utilizing CIQ had reduced hypoglycemia concerns and parenting stress, and improved quality of life and sleep. These findings demonstrate the benefit of CIQ in young children with type 1 diabetes that goes beyond documented glycemic benefit.


Assuntos
Diabetes Mellitus Tipo 1 , Hipoglicemia , Pré-Escolar , Humanos , Glicemia , Automonitorização da Glicemia/métodos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Hipoglicemia/prevenção & controle , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Medidas de Resultados Relatados pelo Paciente
20.
Diabetes Care ; 2024 Jul 10.
Artigo em Inglês | MEDLINE | ID: mdl-38985499

RESUMO

OBJECTIVE: To evaluate the impact of prolonged hybrid closed loop (HCL) use in children with type 1 diabetes (T1D) on glucose control and BMI throughout pubertal progression. RESEARCH DESIGN AND METHODS: We used a prospective multicenter extension study following the Free-Life Kid AP (FLKAP) HCL trial. The 9-month previously reported FLKAP trial included 119 prepubertal children (aged 6-12 years). During the extension study, participants could continue to use HCL for 30 months (M9 to M39). HbA1c values were collected every 3 months up to M39, while continuous glucose monitoring metrics, BMI Z scores, and Tanner stages were collected up to M24. Noninferiority tests were performed to assess parameter sustainability over time. RESULTS: One hundred seventeen children completed the extension study, with mean age 10.1 years (min-max 6.8-14.0) at the beginning. Improvement of HbA1c obtained in the FLKAP trial was significantly sustained during extension (median [interquartile range], M9: 7.0% [6.8-7.4], and M39: 7.0% [6.6-7.4], P < 0.0001 for noninferiority test) and did not differ between children who entered puberty at M24 (Tanner ≥ stage 2; 54% of the patients) and patients who remained prepubertal. BMI Z score also remained stable (M9: 0.41 [-0.29 to 1.13] and M24: 0.48 [-0.11 to 1.13], P < 0.0001, for noninferiority test). No severe hypoglycemia and one ketoacidosis episode not related to the HCL system occurred. CONCLUSIONS: Prolonged use of HCL can safely and effectively mitigate impairment of glucose control usually associated with pubertal progression without impact on BMI in children with T1D.