Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Front Microbiol ; 9: 911, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29867822

RESUMO

Sepsis is the leading cause of death among patients in intensive care units (ICUs) requiring an early diagnosis to introduce efficient therapeutic intervention. Rapid identification (ID) of a causative pathogen is key to guide directed antimicrobial selection and was recently shown to reduce hospitalization length in ICUs. Direct processing of positive blood cultures by MALDI-TOF MS technology is one of the several currently available tools used to generate rapid microbial ID. However, all recently published protocols are still manual and time consuming, requiring dedicated technician availability and specific strategies for batch processing. We present here a new prototype instrument for automated preparation of Vitek®MS slides directly from positive blood culture broth based on an "all-in-one" extraction strip. This bench top instrument was evaluated on 111 and 22 organisms processed using artificially inoculated blood culture bottles in the BacT/ALERT® 3D (SA/SN blood culture bottles) or the BacT/ALERT VirtuoTM system (FA/FN Plus bottles), respectively. Overall, this new preparation station provided reliable and accurate Vitek MS species-level identification of 87% (Gram-negative bacteria = 85%, Gram-positive bacteria = 88%, and yeast = 100%) when used with BacT/ALERT® 3D and of 84% (Gram-negative bacteria = 86%, Gram-positive bacteria = 86%, and yeast = 75%) with Virtuo® instruments, respectively. The prototype was then evaluated in a clinical microbiology laboratory on 102 clinical blood culture bottles and compared to routine laboratory ID procedures. Overall, the correlation of ID on monomicrobial bottles was 83% (Gram-negative bacteria = 89%, Gram-positive bacteria = 79%, and yeast = 78%), demonstrating roughly equivalent performance between manual and automatized extraction methods. This prototype instrument exhibited a high level of performance regardless of bottle type or BacT/ALERT system. Furthermore, blood culture workflow could potentially be improved by converting direct ID of positive blood cultures from a batch-based to real-time and "on-demand" process.

2.
J Microbiol Methods ; 123: 79-86, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26835844

RESUMO

Pathogen analysis in food samples routinely involves lengthy growth-based pre-enrichment and selective enrichment of food matrices to increase the ratio of pathogen to background flora. Similarly, for blood culture analysis, pathogens must be isolated and enriched from a large excess of blood cells to allow further analysis. Conventional techniques of centrifugation and filtration are cumbersome, suffer from low sample throughput, are not readily amenable to automation and carry a risk of damaging biological samples. We report on-chip acoustophoresis as a pre-analytical technique for the resolution of total microbial flora from food and blood samples. The resulting 'clarified' sample is expected to increase the performance of downstream systems for the specific detection of the pathogens. A microfluidic chip with three inlets, a central separation channel and three outlets was utilized. Samples were introduced through the side inlets, and buffer solution through the central inlet. Upon ultrasound actuation, large debris particles (10-100 µm) from meat samples were continuously partitioned into the central buffer channel, leaving the 'clarified' outer sample streams containing both, the pathogenic cells and the background flora (ca. 1 µm) to be collected over a 30 min operation cycle before further analysis. The system was successfully tested with Salmonella typhimurium-spiked (ca. 10(3)CFU mL(-1)) samples of chicken and minced beef, demonstrating a high level of the pathogen recovery (60-90%). When applied to S. typhimurium contaminated blood samples (10(7)CFU mL(-1)), acoustophoresis resulted in a high depletion (99.8%) of the red blood cells (RBC) which partitioned in the buffer stream, whilst sufficient numbers of the viable S. typhimurium remained in the outer channels for further analysis. These results indicate that the technology may provide a generic approach for pre-analytical sample preparation prior to integrated and automated downstream detection of bacterial pathogens.


Assuntos
Sangue/microbiologia , Carne/microbiologia , Técnicas Analíticas Microfluídicas/métodos , Salmonella typhimurium/isolamento & purificação , Animais , Bovinos , Galinhas , Contaminação de Alimentos/análise , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Reação em Cadeia da Polimerase , Salmonella typhimurium/genética
3.
Anal Chim Acta ; 918: 69-76, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-27046212

RESUMO

This study reports multiplex sorting of Salmonella typhimurium and Escherichia coli 0157, from broth cultures and from pathogen-spiked skinned chicken breast enrichment broths by employing microfluidic free-flow magnetophoresis. Magnetic beads of different sizes and magnetite content, namely Dynabeads anti-salmonella and Hyglos-Streptavidin beads together with the corresponding pathogen-specific biotinylated recombinant phages, were utilised as affinity solid phases for the capture and concentration of viable S. typhimurium and E. coli 0157. Following optimisation, the protocol was used to demonstrate continuous magnetophoretic sorting of the two pathogen-bound magnetic bead populations from mixed cultures and from pathogen-spiked chicken pre-enrichment broths under the influence of a Halbach magnet array. For example, in the latter case, a pure population of S. typhimurium-bound Dynabeads (72% recovery) was sorted from a 100 µL mixture containing E. coli 0157-bound Hyglos beads (67% recovery) within 1.2 min in the presence of 0.1% Tween 20. This proof-of-principle study demonstrates how more than one pathogen type can be simultaneously isolated/enriched from a single food pre-enrichment broth (e.g. Universal food enrichment broth).


Assuntos
Microbiologia de Alimentos , Separação Imunomagnética/métodos , Microscopia Eletrônica de Varredura
4.
Sci Rep ; 5: 13944, 2015 Sep 09.
Artigo em Inglês | MEDLINE | ID: mdl-26350205

RESUMO

Mass spectrometry (MS) in Selected Reaction Monitoring (SRM) mode is proposed for in-depth characterisation of microorganisms in a multiplexed analysis. Within 60-80 minutes, the SRM method performs microbial identification (I), antibiotic-resistance detection (R), virulence assessment (V) and it provides epidemiological typing information (T). This SRM application is illustrated by the analysis of the human pathogen Staphylococcus aureus, demonstrating its promise for rapid characterisation of bacteria from positive blood cultures of sepsis patients.


Assuntos
Bactérias/classificação , Bactérias/efeitos dos fármacos , Técnicas de Tipagem Bacteriana , Espectrometria de Massas/métodos , Bactérias/patogenicidade , Técnicas de Tipagem Bacteriana/métodos , Farmacorresistência Bacteriana , Humanos , Reprodutibilidade dos Testes , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/classificação , Staphylococcus aureus/efeitos dos fármacos , Staphylococcus aureus/patogenicidade , Virulência/genética
5.
Biomed Microdevices ; 10(1): 35-45, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17636395

RESUMO

Clinical diagnostics is one of the most promising applications for microfluidic lab-on-a-chip or lab-on-card systems. DNA chips, which provide multiparametric data, are privileged tools for genomic analysis. However, automation of molecular biology protocol and use of these DNA chips in fully integrated systems remains a great challenge. Simplicity of chip and/or card/instrument interfaces is amongst the most critical issues to be addressed. Indeed, current detection systems for DNA chip reading are often complex, expensive, bulky and even limited in terms of sensitivity or accuracy. Furthermore, for liquid handling in the lab-on-cards, many devices use complex and bulky systems, either to directly manipulate fluids, or to ensure pneumatic or mechanical control of integrated valves. All these drawbacks prevent or limit the use of DNA-chip-based integrated systems, for point-of-care testing or as a routine diagnostics tool. We present here a DNA-chip-based protocol integration on a plastic card for clinical diagnostics applications including: (1) an opto-electronic DNA-chip, (2) fluid handling using electrically activated embedded pyrotechnic microvalves with closing/opening functions. We demonstrate both fluidic and electric packaging of the optoelectronic DNA chip without major alteration of its electronical and biological functionalities, and fluid control using novel electrically activable pyrotechnic microvalves. Finally, we suggest a complete design of a card dedicated to automation of a complex biological protocol with a fully electrical fluid handling and DNA chip reading.


Assuntos
Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Automação , Desenho Assistido por Computador , Humanos , Análise de Sequência com Séries de Oligonucleotídeos/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA