Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Neuropediatrics ; 51(6): 435-439, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32818970

RESUMO

Congenital bilateral perisylvian syndrome (CBPS) is a rare neurological disorder associated with typical clinical and imaging features such as bilateral symmetrical polymicrogyria, either exclusively or mainly affecting the perisylvian region of the brain. We present a girl with the typical clinical picture of a CBPS and a complex migration disorder, predominantly presenting as bilateral symmetrical polymicrogyria associated with corpus callosum hyperplasia, ventricular dilation, and pontine hypoplasia. At the age of 6 months, the girl showed a profound global developmental delay, seizures refractory to treatment, and severe oromotor dysfunction. Exome analysis revealed a de novo mutation in microtubule-associated serine/threonine kinase 1 (MAST1). Recently, mutations in this gene were described in six patients with a cortical migration disorder named mega-corpus-callosum syndrome with cerebellar hypoplasia. Although all patients present the clinical and imaging features of CBPS, a clear assignment between CBPS and MAST1 mutations has not been reported yet.


Assuntos
Anormalidades Múltiplas/diagnóstico , Anormalidades Múltiplas/genética , Deficiência Intelectual/diagnóstico , Deficiência Intelectual/genética , Malformações do Desenvolvimento Cortical/diagnóstico , Malformações do Desenvolvimento Cortical/genética , Proteínas Associadas aos Microtúbulos/genética , Proteínas Serina-Treonina Quinases/genética , Anormalidades Múltiplas/patologia , Anormalidades Múltiplas/fisiopatologia , Encéfalo/diagnóstico por imagem , Encéfalo/patologia , Feminino , Humanos , Lactente , Deficiência Intelectual/patologia , Deficiência Intelectual/fisiopatologia , Malformações do Desenvolvimento Cortical/patologia , Malformações do Desenvolvimento Cortical/fisiopatologia , Mutação
2.
Z Geburtshilfe Neonatol ; 221(6): 276-282, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29041013

RESUMO

Maternal aneurysmal subarachnoid hemorrhage (aSAH) during pregnancy presents a challenge regarding treatment and management. Due to the limited number of cases there are no treatment guidelines available. Thus, treatment is usually done on a case-by-case basis. Here we report on four cases of aSAH during pregnancy, describing the different management strategies and suggesting a possible treatment algorithm. Patients treated between 2003 and 2013 in our center were included in this retrospective study. Clinical data focused on time management concerning gestation week (GW), microsurgical or endovascular treatment, and outcome of the patients and the fetuses. Results were compared to the present literature on this issue. Mean age was 30.8 years, initial Hunt & Hess (H&H) grade ranged from III to V. All patients suffered from aSAH during the 3rd trimester of pregnancy. In the four cases, two emergency Caesarean sections (CS) were performed. Two aneurysms were occluded by microsurgical clipping and one was treated endovascularly. One patient died before definitive treatment of the aneurysm could be achieved, whereas fetal mortality was 0%. The mean follow-up was 83 months. aSAH during pregnancy needs individualized interdisciplinary management. Efforts must focus on the mother so that a delay in the best available treatment for the pregnant patient is avoided. Therefore treatment modality should be primarily determined by the aneurysm itself. However, timing in terms of delivery of the fetus and aneurysm treatment is a crucial point.


Assuntos
Comunicação Interdisciplinar , Colaboração Intersetorial , Complicações Cardiovasculares na Gravidez/terapia , Hemorragia Subaracnóidea/terapia , Adulto , Algoritmos , Cesárea , Embolização Terapêutica , Feminino , Seguimentos , Alemanha , Escala de Resultado de Glasgow , Humanos , Recém-Nascido , Microcirurgia , Gravidez , Complicações Cardiovasculares na Gravidez/diagnóstico , Resultado da Gravidez , Terceiro Trimestre da Gravidez , Hemorragia Subaracnóidea/diagnóstico , Instrumentos Cirúrgicos
3.
Eur Spine J ; 25(5): 1349-1354, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26769034

RESUMO

PURPOSE: It is undisputed for more than 200 years that the use of a parachute prevents major trauma when falling from a great height. Nevertheless up to date no prospective randomised controlled trial has proven the superiority in preventing trauma when falling from a great height instead of a free fall. The aim of this prospective randomised controlled trial was to prove the effectiveness of a parachute when falling from great height. METHODS: In this prospective randomised-controlled trial a commercially acquirable rag doll was prepared for the purposes of the study design as in accordance to the Declaration of Helsinki, the participation of human beings in this trial was impossible. Twenty-five falls were performed with a parachute compatible to the height and weight of the doll. In the control group, another 25 falls were realised without a parachute. The main outcome measures were the rate of head injury; cervical, thoracic, lumbar, and pelvic fractures; and pneumothoraxes, hepatic, spleen, and bladder injuries in the control and parachute groups. An interdisciplinary team consisting of a specialised trauma surgeon, two neurosurgeons, and a coroner examined the rag doll for injuries. Additionally, whole-body computed tomography scans were performed to identify the injuries. RESULTS: All 50 falls-25 with the use of a parachute, 25 without a parachute-were successfully performed. Head injuries (right hemisphere p = 0.008, left hemisphere p = 0.004), cervical trauma (p < 0.001), thoracic trauma (p < 0.001), lumbar trauma (p < 0.001), pelvic trauma (p < 0.001), and hepatic, spleen, and bladder injures (p < 0.001) occurred more often in the control group. Only the pneumothoraxes showed no statistically significant difference between the control and parachute groups. CONCLUSIONS: A parachute is an effective tool to prevent major trauma when falling from a great height.


Assuntos
Acidentes por Quedas/prevenção & controle , Traumatismos Craniocerebrais/prevenção & controle , Fraturas Ósseas/prevenção & controle , Humanos , Manequins , Ossos Pélvicos/lesões , Estudos Prospectivos , Equipamentos de Proteção , Projetos de Pesquisa
4.
Neuropediatrics ; 46(2): 139-44, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25671339

RESUMO

Brainstem disconnection (BD) is a rare posterior fossa abnormality defined by the nearly complete absence of a brainstem segment with the rostral and caudal brainstem portions connected only by a thin cord of tissue. The outcome is poor and the majority of children die within the first 2 months of life without achieving developmental milestones. We report on the cases of two children with BD and a prolonged spontaneous survival. Neither patient required intubation or mechanical ventilation and each survived longer than 2 months (one child died at the age of 8 months, the other is alive at the age of 4.5 years). In addition, patient 1 is the only child with BD reported so far who achieved some developmental milestones. Although the long-term neurodevelopmental outcome of BD remains unfavorable, the expansion of the phenotypic spectrum may be important in terms of counseling.


Assuntos
Tronco Encefálico/anormalidades , Tronco Encefálico/patologia , Fossa Craniana Posterior/anormalidades , Pré-Escolar , Humanos , Lactente , Imageamento por Ressonância Magnética , Fenótipo
5.
J Neurointerv Surg ; 16(3): 285-289, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-37147003

RESUMO

BACKGROUND: Repeated number of passes, clot fragmentation, and distal embolization during mechanical thrombectomy (MT) lead to worse clinical outcomes in acute ischemic stroke. This study aimed to assess the recanalization and embolic outcomes of different stent-retrievers (SRs): open-tip SR (Solitaire X 6×40 mm), closed-tip SR (EmboTrap II 5×33 mm), and filter-tip SR (NeVa NET 5.5×37 mm). METHODS: Stiff-friable clot analogs were used to create middle cerebral artery (M1-MCA) occlusions in a benchtop model. After occlusion, experiments were randomized into one of the three treatment arms. The thrombectomy technique consisted of retrieving the SR into a balloon guide catheter under proximal flow arrest and continuous aspiration. A total of 150 single-attempt cases were performed (50 cases/treatment arm). Distal emboli (>100 µm) were collected and analyzed after each experiment. RESULTS: Filter-tip SR achieved a non-significantly higher first-pass recanalization rate than open-tip SR and closed-tip SR (66% vs 48% vs 44%; P=0.064). Filter-tip SR prevented clot fragments>1 mm from embolizing distal territories in 44% of cases, compared with 16% in open-tip SR and 20% in closed-tip (P=0.003). There were no significant differences between treatment arms in terms of total emboli count (open-tip=19.2±13.1, closed-tip=19.1±10.7, filter-tip=17.2±13.0; P=0.660). Nonetheless, the number of large emboli (>1 mm) and total area of emboli were significantly lower in the filter-tip arm (n=0.88±1.2, A=2.06±1.85 mm2) than in the closed-tip arm (n=2.34±3.38, A=4.06±4.80 mm2; P<0.05). CONCLUSIONS: When facing fragment-prone clots, the filter-tip SR significantly reduces the number of large clots (>1 mm) that embolize distally during an MT procedure, which in turn may increase the chances of first-pass complete recanalization.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Trombose , Humanos , Resultado do Tratamento , Trombectomia/métodos , Stents , Acidente Vascular Cerebral/prevenção & controle
6.
J Clin Med ; 12(17)2023 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-37685799

RESUMO

Clinical magnetic resonance imaging (MRI) aims for the highest possible image quality, while balancing the need for acceptable examination time, reasonable signal-to-noise ratio (SNR), and lowest artifact burden. With a recently introduced imaging acceleration technique, compressed sensing, the acquisition speed and image quality of pediatric brain tumor exams can be improved. However, little attention has been paid to its impact on method-related artifacts in pediatric brain MRI. This study assessed the overall artifact burden and artifact appearances in a standardized pediatric brain tumor MRI by comparing conventional parallel imaging acceleration with compressed sensing. This showed that compressed sensing resulted in fewer physiological artifacts in the FLAIR sequence, and a reduction in technical artifacts in the 3D T1 TFE sequences. Only a slight difference was noted in the T2 TSE sequence. A relatively new range of artifacts, which are likely technique-related, was noted in the 3D T1 TFE sequences. In conclusion, by equipping a basic pediatric brain tumor protocol for 3T MRI with compressed sensing, the overall burden of common artifacts can be reduced. However, attention should be paid to novel compressed-sensing-specific artifacts.

7.
Front Neurol ; 14: 1247421, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37727579

RESUMO

Purpose: Given the inherent complexity of neurointerventional procedures and the associated risks of ionizing radiation exposure, it is crucial to prioritize ongoing training and improve safety protocols. The aim of this study is to assess a training and evaluation in-vitro environment using a vascular model of M1 stenosis, within a clinical angiography suite, without relying on animal models or X-ray radiation. Materials and methods: Using a transparent model replicating M1 stenosis, we conducted intracranial stenting procedures with four different setups (Gateway & Wingspan, Gateway & Enterprise, Neurospeed & Acclino, and Pharos Vitesse). A video camera was integrated with the angiography system's monitor for real-time visualization, while a foot switch was employed to simulate live fluoroscopy. Three neuroradiologists with varying levels of expertise performed each procedure for three times. The total duration of fluoroscopy as well as the time from passing the stenosis with the wire to completion of the procedure were recorded using a dedicated software designed for this experimental setup. Results: Compared to the Gateway & Wingspan procedure, the total fluoroscopy time reduced significantly with the Gateway & Enterprise, Neurospeed & Acclino, and Pharos Vitesse procedures by 51.56 s, 111.33 s, and 144.89 s, respectively (p < 0.001). Additionally, physicians with under 2 years and over 5 years of experience reduced FT by 62.83 s and 106.42 s, respectively, (p < 0.001), compared to a novice physician. Similar trends were noted for the time of wire distal to stenosis, with significant reductions for Neurospeed & Acclino and Pharos Vitesse compared to both Gateway & Wingspan as well as Gateway & Enterprise (all p < 0.001). Conclusion: Procedures requiring wire exchange maneuvers exhibited nearly twice the fluoroscopy time in comparison to balloon-mounted stenting or stent-placement via PTA balloon catheters. The more experienced neuroradiologist demonstrated significantly quicker performance in line with expectations in a real-life clinical setting, when compared to the less experienced interventionalist. This in-vitro setup allowed the evaluation of alternative technical approaches and differences in experience of operators without the use of animal models or X-ray. The setup combines advantages of simulators and silicone vessel models in a realistic working environment.

8.
J Neurointerv Surg ; 15(7): 650-654, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35882550

RESUMO

BACKGROUND: The CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS) study has shown that the endovascular treatment of ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) is safe and effective and provides protection against rebleeding at 1 month and 1 year. The 12-month angiographic follow-up is an important endpoint of the study. METHODS: The CLARYS study is a prospective multicenter study conducted in 13 European centers. The study enrolled 60 patients with 60 ruptured aneurysms of the anterior and posterior circulation. The study was conducted with an independent assessment of safety outcomes and imaging. RESULTS: Sixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. Fifty-three aneurysms (88.3%) had a broad base with a dome to neck ratio <2 (mean 1.6). Of these, 46 patients were evaluated by an independent core laboratory with follow-up imaging performed at 12 months or before eventual retreatment. At 1 year, 19/46 aneurysms (41.3%) were completely occluded (Raymond-Roy grade I), 21/46 (45.7%) had a residual neck and 6/46 (13.0%) had residual aneurysm filling. Adequate occlusion was reported in 40/46 (87%) aneurysms. Six patients underwent target aneurysm retreatment. CONCLUSIONS: The CLARYS study has previously shown that the use of the WEB in the endovascular treatment of ruptured bifurcation aneurysms provides effective protection against rebleeding with a good safety profile. The angiographic occlusion rates at 1 year reported here are comparable to those already seen in previous multicenter studies which primarily included unruptured aneurysms.


Assuntos
Aneurisma Roto , Procedimentos Endovasculares , Aneurisma Intracraniano , Humanos , Resultado do Tratamento , Estudos Prospectivos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Procedimentos Endovasculares/métodos , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia
9.
J Neurointerv Surg ; 14(8): 807-814, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34493578

RESUMO

BACKGROUND: The primary goal of the CLARYS study is to assess the protection against rebleeding when treating ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) device. METHODS: The CLARYS study is a prospective, multicenter study conducted in 13 European centers. Patients with ruptured bifurcation aneurysms were consecutively included between February 2016 and September 2017. The primary endpoint was defined as the rebleeding rate of the target aneurysm treated with the WEB within 30 days postprocedure. Secondary endpoints included periprocedural and postprocedural adverse events, total procedure and fluoroscopy times, and modified Rankin Scale score at 1 month and 1 year. RESULTS: Sixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. A WEB device was successfully implanted in 93.3%. The rebleeding rate at 1 month and 1 year was 0%. The mean fluoroscopy time was 27.0 min. Twenty-three periprocedural complications were observed in 18 patients and resolved without sequelae in 16 patients. Two of these complications were attributed to the procedure and/or the use of the WEB, leading to a procedure/device-related intraoperative complication rate of 3.3%. Overall mortality at 1 month and 1 year was 1.7% and 3.8%, respectively and overall morbidity at 1 month and 1 year was 15% and 9.6%, respectively. WEB-related 1-month and 1-year morbidity and mortality was 0%. CONCLUSIONS: The interim results of CLARYS show that the endovascular treatment of ruptured bifurcation aneurysms with the WEB is safe and effective and, in particular, provides effective protection against rebleeding. It may induce profound change in the endovascular management of ruptured bifurcation aneurysms.


Assuntos
Aneurisma Roto , Embolização Terapêutica , Procedimentos Endovasculares , Aneurisma Intracraniano , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/cirurgia , Embolização Terapêutica/métodos , Procedimentos Endovasculares/métodos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/cirurgia , Estudos Prospectivos , Próteses e Implantes , Estudos Retrospectivos , Resultado do Tratamento
10.
Eur Radiol ; 21(12): 2626-32, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21761279

RESUMO

OBJECTIVES: Different compositions of the extra cellular matrix with changing concentrations of more or less hydrophilic components like proteins may have a major influence on the diffusion phenomena found in gliomas. METHODS: 24 patients (14 male / 10 female) with histologically confirmed non necrotic glioma underwent preoperative MRI, including magnetisation transfer (MTR), triple echo T2 weighted (T2W) and diffusion weighted (DWI) sequences. Apparent diffusion coefficient (ADC), quantitative T2 and MTR maps were calculated and regions of interest (ROIs) were placed in the tumour centre (TU) and in the contralateral hemisphere (NWM). Informed consent was obtained. The study was approved by the local ethic comity. RESULTS: Mean values evaluated in the NWM / TU were (± standard deviation); ADC: 0.78 (±0.08) × 10-3 mm2/s / 1.32 (±0.27) × 10-3 mm2/s, T2: 101.66 (±12.00) ms / 252.11 (±104.53) ms, MTR: 0.52 (±0.01) / 0.40 (±0.04). The mean value of each parameter correlated highly significant with the others (p < 0.01). CONCLUSION: Our results suggest that macromolecules binding protons in their vicinity are a major determinant of proton diffusivity in brain tumours in addition to other factors such as mechanical barriers like membranes or the size of the extra-cellular space.


Assuntos
Neoplasias Encefálicas/diagnóstico , Glioma/diagnóstico , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Neoplasias Encefálicas/genética , Neoplasias Encefálicas/patologia , Imagem de Difusão por Ressonância Magnética , Feminino , Glioma/genética , Glioma/patologia , Humanos , Substâncias Macromoleculares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Cuidados Pré-Operatórios
11.
J Comput Assist Tomogr ; 35(1): 4-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21150452

RESUMO

OBJECTIVE: Evaluation of the diagnostic detectability of the intracranial vasculature on contrast-enhanced whole-body magnetic resonance angiographic (WBMRA) scans at 1.5 versus 3 T. METHODS: Twenty-seven patients with hereditary hyperlipidemia participated. Two experienced neuroradiologists scored the image quality regarding the intracranial arteries applying a 5-point scale. Stenoses and other findings were documented. Weighted κ-statistics were calculated to assess interobserver agreement. RESULTS: Interobserver agreement was very good. Image quality scoring resulted in the following mean values: 3.0 at 1.5 T versus 3.9 at 3 T (P < 0.001). Venous contrast overlay and insufficient anatomic coverage occurred in both groups. Three stenoses were found at both field strengths. CONCLUSIONS: Assessment of the intracranial vasculature on WBMRA data is basically feasible; image quality at 3 T seems superior. Shortcomings appear because of venous contamination and insufficient volume coverage. Therefore, adding a dedicated intracranial MRA to a WBMRA protocol would substantially increase diagnostic certainty.


Assuntos
Artérias , Circulação Cerebrovascular , Arteriosclerose Intracraniana/diagnóstico , Angiografia por Ressonância Magnética/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Hiperlipidemias/patologia , Masculino , Pessoa de Meia-Idade , Compostos Organometálicos , Estudos Prospectivos , Fatores de Risco , Estatísticas não Paramétricas
12.
Acta Radiol ; 52(5): 547-53, 2011 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-21498295

RESUMO

BACKGROUND: Patients suffering from hereditary hyperlipidemia have a high risk for premature cardiovascular disease and death as a consequence of accelerated atherosclerosis. PURPOSE: To prospectively and intra-individually compare image quality and detectability of stenoses in contrast enhanced whole-body MRA (WBMRA) at 1.5 and 3 Tesla (T) in patients with hereditary hyperlipidemia. MATERIAL AND METHODS: Twenty-seven patients with hereditary hyperlipidemia received a 1.5 and 3 T gadopentetate dimeglumine contrast-enhanced WBMRA. Twenty-three defined arterial segments were analyzed regarding depiction of target vessels and image quality according to a 5-point-scale ('not evaluable' to 'excellent'). Wilcoxon matched pair test was performed for comparison. Forty-three defined arterial segments were analyzed for the degree of stenosis (0%, 1-49%, 50-99% and 100%) as well as vessel alterations such as aneurysms. Chi-square test was performed for comparison. RESULTS: 1.5 T and 3 T scans yielded WBMRA with diagnostic quality in all patients. In seven of 23 arterial segments (30.4%) image quality was rated significantly higher at 3 T, whereas there was no significant difference in the remaining 16 segments between WBMRA at 1.5 T and 3 T. All relevant stenoses (n = 5), occlusions (n = 6), and aneurysms (n = 3) were evaluated similarly at both field strengths. CONCLUSION: WBMRA can be performed at 1.5 T and 3 T with diagnostic image quality. Image quality was significantly higher at 3 T than at 1.5 T in only 30.4% of the arterial segments. In order to effectively take advantage of the higher field strength, further optimization of sequence parameters and injection protocols for WBMRA at 3 T is necessary.


Assuntos
Arteriopatias Oclusivas/diagnóstico , Hiperlipidemias/diagnóstico , Angiografia por Ressonância Magnética/métodos , Adulto , Idoso , Arteriopatias Oclusivas/genética , Distribuição de Qui-Quadrado , Meios de Contraste , Feminino , Gadolínio DTPA , Genótipo , Humanos , Hiperlipidemias/genética , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estatísticas não Paramétricas , Imagem Corporal Total
13.
Stat Methods Med Res ; 30(3): 916-925, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33356965

RESUMO

Imbalance between positive and negative outcomes, a so-called class imbalance, is a problem generally found in medical data. Imbalanced data hinder the performance of conventional classification methods which aim to improve the overall accuracy of the model without accounting for uneven distribution of the classes. To rectify this, the data can be resampled by oversampling the positive (minority) class until the classes are approximately equally represented. After that, a prediction model such as gradient boosting algorithm can be fitted with greater confidence. This classification method allows for non-linear relationships and deep interactive effects while focusing on difficult areas by iterative shifting towards problematic observations. In this study, we demonstrate application of these methods to medical data and develop a practical framework for evaluation of features contributing into the probability of stroke.


Assuntos
Algoritmos , Acidente Vascular Cerebral , Humanos
14.
J Neurointerv Surg ; 13(7): 605-608, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32753556

RESUMO

BACKGROUND: A direct aspiration first pass technique (ADAPT) is an efficient, safe, cost-effective, and fast thrombectomy technique. OBJECTIVE: To evaluate anatomical and clot characteristics associated with success of the aspiration component as part of ADAPT. METHODS: 106 cases of acute carotid-T, basilar, and middle cerebral artery occlusion undergoing endovascular treatment with ADAPT were retrospectively assessed for successful catheter-clot contact and successful primary aspiration, defined as a Thrombolysis in Cerebral Infarction score ≥2b after primary aspiration with 5F or 6F aspiration catheters. Patient age, National Institutes of Health Stroke Scale (NIHSS) score, time from symptom onset to groin puncture, time from groin puncture to revascularization, aortic arch type, access vessel tortuosity, vessel diameter at the proximal end of the thrombus, catheter-to-vessel ratio (CVR), clot density, length, and perviousness were determined. RESULTS: Successful clot contact with the aspiration catheter was achieved in 76 cases (72%); these patients were younger (67.7±15.2 vs 73.7±11.4 years; p=0.05) and had less tortuous access vessels (1 vs 2 reverse curves; p=0.004) than those in whom clot contact failed. Successful primary aspiration occurred in 36 of these cases (47%) and was associated with significantly smaller vessel diameter at the proximal thrombus end (2.5±0.7 mm vs 3.1±1.3 mm; p=0.01) and higher CVR (CVR outer diameter: 0.85±0.2 vs 0.68±0.2; p=0.01 and CVR inner diameter: 0.72±0.2 vs 0.58±0.2; p<0.001). No significant differences were seen in aortic arch type, radiographic clot features, and NIHSS score. CONCLUSION: With ADAPT, patient age and vessel tortuosity affect the ability to deliver the aspiration catheter and achieve clot contact, whereas vessel diameter and CVR at the aspiration site seem to affect the effectiveness of clot aspiration. Strategies aimed at improving catheter deliverability and increasing CVR may increase the efficacy of ADAPT.


Assuntos
Catéteres , Infarto da Artéria Cerebral Média/terapia , Trombectomia/instrumentação , Trombectomia/métodos , Dispositivos de Acesso Vascular , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/terapia , Feminino , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/terapia , Resultado do Tratamento
15.
Clin Neuroradiol ; 31(1): 181-187, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31863121

RESUMO

PURPOSE: Stroke patients are excluded from expeditious thrombectomy in regions lacking neurointerventional specialists. An audiovisual online streaming system was tested, allowing a neurointerventional specialist located at a neurovascular center to supervise and instruct a thrombectomy performed at a distant hospital without being physically present (remote streaming support [RESS]). METHODS: In total, 36 thrombectomy procedures were performed on a Mentice endovascular simulator by six radiologists not specialized in neurointerventions. Each radiologist was challenged with six different endovascular simulation scenarios under alternating conventional local support (specialist inside the room [LOS]) and RESS, which was performed using an advanced live streaming platform. RESULTS: Both support modes led to a median of 2 attempts (interquartile range [IQR] 2.0-2.0 each) until successful recanalization. There was no statistically significant difference in time from first catheter insertion to recanalization between LOS (median 24.9 min, IQR 21.0-31.5 min) and RESS (23.9 min, IQR 21.7-28.7 min, p = 0.89). The percentage of thrombi covered by the stent-retriever and average speed when retrieving the stent-retriever (3.7 mm/s, IQR 3.25-5.35 mm/s vs. 3.6 mm/sec, IQR 2.5-4.7) were similar in both groups. Fluoroscopy time did not differ (19.0 min, IQR 16.9-23.5 min vs. 19.9 min, IQR 15.9-23.5 min) with a trend towards increased median amounts of contrast medium used under RESS (62.9 ml vs. 43.1 ml; p = 0.055). CONCLUSION: This study confirmed the feasibility of RESS for thrombectomy procedures in a simulated environment. This serves as basis for future studies planned to analyze the effectiveness of RESS in a real-world environment and to test if it improves the learning curve of interventionalists with limited thrombectomy experience in remote areas.


Assuntos
Isquemia Encefálica , Procedimentos Endovasculares , Acidente Vascular Cerebral , Isquemia Encefálica/diagnóstico por imagem , Isquemia Encefálica/cirurgia , Humanos , Estudos Retrospectivos , Stents , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/cirurgia , Trombectomia , Resultado do Tratamento
16.
J Neurointerv Surg ; 13(2): e1, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33082292

RESUMO

This is a report of the first three cases of endovascular aneurysm treatment that were proctored by a remote interventionalist using a novel high-resolution low-latency streaming technology. The proctor was located in a neurovascular centre and supported the treating interventional teams in two distant cities (up to 800 km/500 miles apart). All aneurysms were treated using the Woven EndoBridge (WEB) embolisation system, either electively or following subarachnoid haemorrhage. On-site proctoring was not possible due to travel restrictions during the COVID-19 pandemic. WEB placement was feasible in all cases. Good rapport between proctors and treating physicians was reported, enabled by the high-resolution image transmission and uninterrupted feedback/discussion via audiostream. No clinical complications were encountered. Short-term follow-up revealed adequate occlusion of all treated aneurysms. The employed streaming technology provided effective remote proctoring during complex aneurysm cases, including the management of technical complications.


Assuntos
COVID-19 , Procedimentos Endovasculares/métodos , Aneurisma Intracraniano/cirurgia , Procedimentos Neurocirúrgicos/métodos , Pandemias , Telemedicina/métodos , Implante de Prótese Vascular , Comunicação , Embolização Terapêutica , Retroalimentação , Humanos , Resultado do Tratamento , Comunicação por Videoconferência
17.
J Neurointerv Surg ; 13(8): 722-726, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32883781

RESUMO

BACKGROUND: In large vessel occlusionstroke, navigation of aspiration catheters (AC) can be impeded by vessel tortuosity and the ophthalmic artery origin. A novel tapered delivery catheter was designed to facilitate delivery without disturbing the embolus. We assessed AC deliverability in vitro and validated the observations in a first-in-human experience. METHODS: In a vascular model with three challenging craniocervical scenarios, two commercial AC were advanced from the carotid to the middle cerebral artery by four neurointerventionalists. Catheter deliverability with standard microwire and microcatheter (MC) combinations and the Tenzing 7 (T7) Delivery Catheter (Route 92 Medical, San Mateo, CA) were compared. Operators rated aspects of catheter deliverability on a 5-point scale. Results were compared with device delivery patterns at a neurovascular center before and after clinical introduction of T7. RESULTS: In vitro, success rate and speed were higher with T7 (96%; mean 30±10 s) than with MC (65%; 72±47 s, p<0.001 each), with fewer interactions with the occlusion site (T7: 54% vs MC: 77%, p=0.004). T7 received superior ratings regarding carotid artery deflection (T7: 2, IQR1-3 vs MC: 3, IQR2-3, p<0.001), guide catheter pushback (T7: 2, IQR1-3 vs MC: 3, IQR3-3, p<0.001) and ophthalmic artery passage (T7: 1.5, IQR1-2 vs MC: 4, IQR3-5, p<0.001). Before introduction of T7 at a single center, delivery of AC to a large vessel occlusion without crossing was achieved in 15/123 cases (12%). With T7, this rate was 28/31 patients (90.3%). CONCLUSION: Compared with microcatheter and microwire combinations, T7 improves aspiration catheter delivery in vitro, minimizing the need to cross the occlusion. Initial clinical experience appears to validate the model's observations.


Assuntos
Artérias Carótidas/cirurgia , Catéteres , Revascularização Cerebral , Desenho de Equipamento , Embolia Intracraniana , AVC Isquêmico , Artéria Cerebral Média/cirurgia , Trombectomia , Revascularização Cerebral/instrumentação , Revascularização Cerebral/métodos , Humanos , Embolia Intracraniana/complicações , Embolia Intracraniana/cirurgia , AVC Isquêmico/etiologia , AVC Isquêmico/cirurgia , Teste de Materiais/métodos , Estudos Retrospectivos , Trombectomia/instrumentação , Trombectomia/métodos , Resultado do Tratamento
18.
J Neurointerv Surg ; 13(6): 541-546, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32900908

RESUMO

BACKGROUND: Flow diverters (FD) are used regularly for the endovascular treatment of unruptured intracranial aneurysms. We aimed to assess the safety and effectiveness of the Derivo embolization device (DED) with respect to long-term clinical and angiographic outcomes. METHODS: A prospective multicenter trial was conducted at 12 centers. Patients presenting with modified Rankin Score (mRS) of 0-1, treated for unruptured intracranial aneurysms with DED were eligible. Primary endpoint was the mRS assessed at 18 months with major morbidity defined as mRS 3-5. Satisfactory angiographic occlusion was defined as 3+4 on the Kamran scale. RESULTS: Between July 2014 and February 2018, 119 patients were enrolled. Twenty-three patients were excluded. Ninety-six patients, 71 (74%) female, mean age 54±12.0 years, were included in the analysis. Mean aneurysm size was 14.2±16.9 mm. The mean number of devices implanted per patient was 1.2 (range 1-3). Clinical follow-up at 18 months was available in 90 (94%) patients, resulting in a mean follow-up period of 14.8±5.2 months. At last available follow-up of 96 enrolled patients, 91 (95%) remained mRS 0-1. The major morbidity rate (mRS 3-5) was 3.1% (3/96), major stroke rate was 4.2% (4/96), and mortality was 0%. Follow-up angiographies were available in 89 (93%) patients at a median of 12.4±5.84 months with a core laboratory adjudicated satisfactory aneurysm occlusion in 89% (79/89). CONCLUSION: Our results suggest that DED is a safe and effective treatment for unruptured aneurysms with high rates of satisfactory occlusion and comparably low rates of permanent neurological morbidity and mortality. TRIAL REGISTRATION: DRKS00006103.


Assuntos
Embolização Terapêutica/métodos , Aneurisma Intracraniano/diagnóstico por imagem , Aneurisma Intracraniano/terapia , Adulto , Idoso , Angiografia Cerebral/métodos , Procedimentos Endovasculares/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
19.
J Neurointerv Surg ; 13(2): 153-158, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32611622

RESUMO

BACKGROUND: Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. OBJECTIVE: To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. METHODS: Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. RESULTS: A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). CONCLUSION: Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.


Assuntos
Aneurisma Roto/terapia , Prótese Vascular/normas , Embolização Terapêutica/normas , Aneurisma Intracraniano/terapia , Pontuação de Propensão , Stents Metálicos Autoexpansíveis/normas , Adulto , Idoso , Aneurisma Roto/diagnóstico por imagem , Estudos de Coortes , Embolização Terapêutica/métodos , Feminino , Seguimentos , Humanos , Aneurisma Intracraniano/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
PLoS One ; 15(9): e0238952, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32941466

RESUMO

OBJECTIVE: To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models ('HANNES'; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different levels of experience. METHODS: Six physicians with different degrees of neurointerventional procedural experience were recruited into a standardized training protocol comprising catheterization of two internal carotid artery (ICA) aneurysms and one basilar tip aneurysm, followed by introduction of one framing coil into each aneurysm and finally complete coil embolization of one determined ICA aneurysm. The level of difficulty increased with every aneurysm. Fluoroscopy was recorded and assessed for procedural characteristics and adverse events. RESULTS: Physicians were divided into inexperienced and experienced operators, depending on their experience with microcatheter handling. Mean overall catheterization times increased with difficulty of the aneurysm model. Inexperienced operators showed longer catheterization times (median; IQR: 47; 30-84s) than experienced operators (21; 13-58s, p = 0.011) and became significantly faster during the course of the attempts (rho = -0.493, p = 0.009) than the experienced physicians (rho = -0.318, p = 0.106). Number of dangerous maneuvers throughout all attempts was significantly higher for inexperienced operators (median; IQR: 1.0; 0.0-1.5) as compared to experienced operators (0.0; 0.0-1.0, p = 0.014). CONCLUSION: HANNES represents a modular neurointerventional training environment for practicing aneurysm coil embolization in vitro. Objective procedural metrics correlate with operator experience, suggesting that the system could be useful for assessing operator proficiency.


Assuntos
Educação Médica/métodos , Embolização Terapêutica/métodos , Treinamento por Simulação/métodos , Adulto , Prótese Vascular , Cateterismo/métodos , Angiografia Cerebral/métodos , Simulação por Computador , Estudos de Viabilidade , Feminino , Humanos , Aneurisma Intracraniano/terapia , Masculino , Pessoa de Meia-Idade , Modelos Biológicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA