Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 412(21): 5105-5111, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31989192

RESUMO

Nowadays, considerable efforts are focused on advancing DNA detection methods, which are extremely important in clinical diagnostics, pathogen determination, gene therapy, and forensic analysis. A one-pot sensitive microplate-based chemiluminescent assay coupled with catalytic hairpin assembly (CHA) amplification for detection of a 35-mer DNA oligonucleotide was developed. To improve the assay sensitivity, a triple amplification strategy based on the application of CHA (1), streptavidin-polyperoxidase conjugate (Stp-polyHRP) (2), and an enhanced chemiluminescent reaction (3) was used. The one-pot format of the assay, where all steps of the DNA determination are performed in the same well without transfer of samples from one test tube to another, increased its precision. The proposed assay detected the target DNA in the fM range and distinguished the target DNA from related DNAs, demonstrating its high sensitivity and high selectivity. Moreover, the assay was applied successfully for the quantitative determination of the target in spiked samples of human plasma. A microplate format of the assay was convenient for the analysis of a large number of samples. This study provides a prospective tool for DNA detection. Graphical abstract.


Assuntos
DNA/análise , Luminescência , Técnicas de Amplificação de Ácido Nucleico/métodos , Peroxidase do Rábano Silvestre/química , Limite de Detecção , Estudo de Prova de Conceito , Estreptavidina/química
2.
Sensors (Basel) ; 19(23)2019 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-31766483

RESUMO

Bottom-up, end-user based feed, and food analysis through smartphone quantification of lateral flow assays (LFA) has the potential to cause a paradigm shift in testing capabilities. However, most developed devices do not test the presence of and implications of inter-phone variation. Much discussion remains regarding optimum color space for smartphone colorimetric analyses and, an in-depth comparison of color space performance is missing. Moreover, a light-shielding box is often used to avoid variations caused by background illumination while the use of such a bulky add-on may be avoidable through image background correction. Here, quantification performance of individual channels of RGB, HSV, and LAB color space and ΔRGB was determined for color and color intensity variation using pH strips, filter paper with dropped nanoparticles, and colored solutions. LAB and HSV color space channels never outperformed the best RGB channels in any test. Background correction avoided measurement variation if no direct sunlight was used and functioned more efficiently outside a light-shielding box (prediction errors < 5%/35% for color/color intensity change). The system was validated using various phones for quantification of major allergens (i.e., gluten in buffer, bovine milk in goat milk and goat cheese), and, pH in soil extracts with commercial pH strips and LFA. Inter-phone variation was significant for LFA quantification but low using pH strips (prediction errors < 10% for all six phones compared). Thus, assays based on color change hold the strongest promise for end-user adapted smartphone diagnostics.


Assuntos
Bioensaio/instrumentação , Colorimetria/instrumentação , Iluminação/instrumentação , Smartphone/instrumentação , Alérgenos , Cor , Concentração de Íons de Hidrogênio
3.
Biosensors (Basel) ; 13(8)2023 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-37622910

RESUMO

CRISPR/Cas12-based biosensors are emerging tools for diagnostics. However, their application of heterogeneous formats needs the efficient detection of Cas12 activity. We investigated DNA probes attached to the microplate surface and cleaved by Cas12a. Single-stranded (ss) DNA probes (19 variants) and combined probes with double-stranded (ds) and ssDNA parts (eight variants) were compared. The cleavage efficiency of dsDNA-probes demonstrated a bell-shaped dependence on their length, with a cleavage maximum of 50%. On the other hand, the cleavage efficiency of ssDNA probes increased monotonously, reaching 70%. The most effective ssDNA probes were integrated with fluorescein, antibodies, and peroxidase conjugates as reporters for fluorescent, lateral flow, and chemiluminescent detection. Long ssDNA probes (120-145 nt) proved the best for detecting Cas12a trans-activity for all of the tested variants. We proposed a test system for the detection of the nucleocapsid (N) gene of SARS-CoV-2 based on Cas12 and the ssDNA-probe attached to the microplate surface; its fluorescent limit of detection was 0.86 nM. Being united with pre-amplification using recombinase polymerase, the system reached a detection limit of 0.01 fM, thus confirming the effectiveness of the chosen ssDNA probe for Cas12-based biosensors.


Assuntos
COVID-19 , Humanos , Sistemas CRISPR-Cas , SARS-CoV-2/genética , Sondas de DNA , Anticorpos , DNA de Cadeia Simples
4.
Talanta ; 247: 123535, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-35598476

RESUMO

Magnetic beads (MBs) are often considered as an effective carrier in heterogeneous assays due to the simplicity of separation and washing, and the ability to increase and control the surface area. However, the effect of the MBs surface on the analytical parameters is poorly characterized and is often postulated from intuitive considerations. Herein, experimental evaluation through the comparison of MBs and microwell plate was carried out using the miRNA-141 (biomarker for cancer) as a target, the detection of which was performed by chemiluminescent assay with a homogeneous mismatched catalytic hairpin assembly (mCHA) reaction. The mCHA reaction produced double-stranded (ds) DNA labeled at one end with fluorescein (Flu) for capture with anti-Flu antibodies immobilized on a solid carrier, on the other end with biotin for recognition by streptavidin-polyperoxidase conjugate. The conditions of immobilization of anti-Flu antibody on MBs (a diameter of 440 nm) performed using a carbodiimide method were optimized by varying the antibody concentration in the reaction solution. It was shown that the dependence of chemiluminescent signal as a function of the concentration of anti-FluAb-MBs conjugates had a bell-shaped character. The maximum chemiluminescence was produced at the concentration of the conjugates of 2 × 109 particles/mL, with a surface area of 65 mm2. The identical surface area was used upon the assay performance with polystyrene microplates. Comparison of MBs- and microplate-assays for miRNA-141 determination showed that the obtained calibration curves and their detection limit values were the same and did not depend on the used carrier. The results showed that the choice of a carrier for heterogeneous assays should be guided by the convenience of the assay performance, not its surface area.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Técnicas Biossensoriais/métodos , DNA , Limite de Detecção , Medições Luminescentes , Campos Magnéticos , MicroRNAs/genética , Estreptavidina
5.
Enzyme Microb Technol ; 131: 109419, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31615661

RESUMO

Fast label-free chemiluminescent assay for determination of exonuclease III (ExoIII) activity measured towards hairpin oligonucleotide substrates was developed. The designed substrates consisted of EAD2 aptamer to hemin which was associated with DNA sequence complementary to 5'-terminus fragment of EAD2. In the presence of ExoIII the associated sequence of the hairpin stem was digested, producing EAD2 aptamer which reacted with hemin with the formation of peroxidase-mimicking DNAzyme (PMDNAzyme). The catalytic activity of the produced PMDNAzyme was measured towards luminol/H2O2. Under the optimized conditions the limit of detection and sensitivity of the one-step chemiluminescent assay of ExoIII were 7.3 nM and 1.7 × 108 M-1, respectively. The coefficient of variation (CV) was lower than 6%.


Assuntos
Exodesoxirribonucleases/análise , Medições Luminescentes/métodos , Oligonucleotídeos/metabolismo , Aptâmeros de Nucleotídeos/metabolismo , Hemina/metabolismo , Conformação de Ácido Nucleico , Oligonucleotídeos/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA