Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BMC Pediatr ; 15: 206, 2015 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-26654316

RESUMO

BACKGROUND: Random safety audits (RSA) are a safety tool enabling prevention of adverse events, but they have not been widely used in hospitals. The aim of this study was to use RSAs to assess and compare the frequency of appropriate use of infusion pump safety systems in a Neonatal Intensive Care Unit (NICU) before and after quality improvement interventions and to analyse the intravenous medication programming data. METHODS: Prospective, observational study comparing the frequency of appropriate use of Alaris® CC smart pumps through RSAs over two periods, from 1 January to 31 December 2012 and from 1 November 2014 to 31 January 2015. Appropriate use was defined as all evaluated variables being correctly programmed into the same device. Between the two periods they were established interventions to improve the use of pumps. The information recorded at the pumps with the new security system, also extracted for one year. RESULTS: Fifty-two measurements were collected during the first period and 160 measurements during the second period. The frequency of appropriate use was 73.13 % (117/160) in the second period versus 0 % (0/52) in the first period (p < 0.0001). Information was recorded on 44,924 infusions; in 46.03 % (20,680/44,924) of cases the drug name was recorded. In 2.5 % (532/20,680) of cases there was an attempt to exceed the absolute limit. CONCLUSIONS: Random Safety Audits were a very useful tool for detecting inappropriate use of pumps in the NICU. The improvement strategies were effective for improving appropriate use and programming of the intravenous medication infusion pumps in our NICU.


Assuntos
Bombas de Infusão , Unidades de Terapia Intensiva Neonatal/normas , Auditoria Médica , Segurança do Paciente/normas , Humanos , Recém-Nascido , Sistemas de Medicação no Hospital/normas , Estudos Prospectivos , Melhoria de Qualidade , Gestão da Segurança
2.
Front Nutr ; 9: 853576, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35369105

RESUMO

Objective: To assess the impact of SARS-CoV-2 viral infection on the metataxonomic profile and its evolution during the first month of lactation. Methods: Milk samples from 37 women with full-term pregnancies and mild SARS-CoV-2 infection and from 63 controls, collected in the first and fifth postpartum weeks, have been analyzed. SARS-CoV-2 RNA was assessed by reverse transcription polymerase chain reaction (RT-PCR) both in cases and controls. After DNA extraction, the V3-V4 hypervariable region of the gene 16S rRNA was amplified and sequenced using the MiSeq system of Illumina. Data were submitted for statistical and bioinformatics analyses after quality control. Results: All the 1st week and 5th week postpartum milk samples were negative for SARS-CoV-2 RNA. Alpha diversity showed no differences between milk samples from the study and control group, and this condition was maintained along the observation time. Analysis of the beta-diversity also indicated that the study and control groups did not show distinct bacterial profiles. Staphyloccus and Streptococcus were the most abundant genera and the only ones that were detected in all the milk samples provided. Disease state (symptomatic or asymptomatic infection) did not affect the metataxonomic profile in breast milk. Conclusion: These results support that in the non-severe SARS-CoV-2 pregnant woman infection the structure of the bacterial population is preserved and does not negatively impact on the human milk microbiota.

3.
Front Immunol ; 12: 720716, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34381462

RESUMO

Objetive: To address the prevalence of SARS-CoV-2 and the evolutionary profile of immune compounds in breastmilk of positive mothers according to time and disease state. Methods: Forty-five women with term pregnancies with confirmed non-severe SARS-CoV-2 infection (case group), and 96 SARS-CoV-2 negative women in identical conditions (control group) were approached, using consecutive sample. Weekly (1st to 5th week postpartum) reverse transcription polymerase chain reaction (RT-PCR) in nasopharyngeal swabs (cases) and breastmilk (cases and controls) were obtained. Concentration of cytokines, chemokines, and growth factors in breastmilk (cases and controls) were determined at 1st and 5th week post-partum. Results: Thirty-seven (study group) and 45 (control group) women were enrolled. Symptomatic infection occurred in 56.8% of women in the study group (48% fever, 48% anosmia, 43% cough). SARS-CoV-2 RNA was not found in breastmilk samples. Concentrations of cytokines (IFN-γ, IL-1ra, IL-4, IL-6, IL-9, IL-13, and TNF-α) chemokines (eotaxin, IP-10, MIP-1α, and RANTES) and growth factors (FGF, GM-CSF, IL7, and PDGF-BB) were higher in breastmilk of the study compared with the control group at 1st week postpartum. Immune compounds concentrations decreased on time, particularly in the control group milk samples. Time of nasopharyngeal swab to become negative influenced the immune compound concentration pattern. Severity of disease (symptomatic or asymptomatic infection) did not affect the immunological profile in breast milk. Conclusions: This study confirms no viral RNA and a distinct immunological profile in breastmilk according to mother's SARS-CoV-2 status. Additional studies should address whether these findings indicate efficient reaction against SARS-CoV-2 infection, which might be suitable to protect the recipient child.


Assuntos
Quimiocinas/análise , Citocinas/análise , Peptídeos e Proteínas de Sinalização Intercelular/análise , Leite Humano/química , Leite Humano/imunologia , Adulto , Aleitamento Materno , COVID-19 , Estudos de Casos e Controles , Feminino , Humanos , Recém-Nascido , Mães , Gravidez , Estudos Prospectivos , RNA Viral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA