Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 20
Filtrar
1.
Pediatr Radiol ; 2024 Jul 17.
Artigo em Inglês | MEDLINE | ID: mdl-39017676

RESUMO

BACKGROUND: Ventricular volumetry using a short-axis stack of two-dimensional (D) cine balanced steady-state free precession (bSSFP) sequences is crucial in any cardiac magnetic resonance imaging (MRI) examination. This task becomes particularly challenging in children due to multiple breath-holds. OBJECTIVE: To assess the diagnostic performance of accelerated 3-RR cine MRI sequences using deep learning reconstruction compared with standard 2-D cine bSSFP sequences. MATERIAL AND METHODS: Twenty-nine consecutive patients (mean age 11 ± 5, median 12, range 1-17 years) undergoing cardiac MRI were scanned with a conventional segmented 2-D cine and a deep learning accelerated cine (three heartbeats) acquisition on a 1.5-tesla scanner. Short-axis volumetrics were performed (semi-)automatically in both datasets retrospectively by two experienced readers who visually assessed image quality employing a 4-point grading scale. Scan times and image quality were compared using the Wilcoxon rank-sum test. Volumetrics were assessed with linear regression and Bland-Altman analyses, and measurement agreement with intraclass correlation coefficient (ICC). RESULTS: Mean acquisition time was significantly reduced with the 3-RR deep learning cine compared to the standard cine sequence (45.5 ± 13.8 s vs. 218.3 ± 44.8 s; P < 0.001). No significant differences in biventricular volumetrics were found. Left ventricular (LV) mass was increased in the deep learning cine compared with the standard cine sequence (71.4 ± 33.1 g vs. 69.9 ± 32.5 g; P < 0.05). All volumetric measurements had an excellent agreement with ICC > 0.9 except for ejection fraction (EF) (LVEF 0.81, RVEF 0.73). The image quality of deep learning cine images was decreased for end-diastolic and end-systolic contours, papillary muscles, and valve depiction (2.9 ± 0.5 vs. 3.5 ± 0.4; P < 0.05). CONCLUSION: Deep learning cine volumetrics did not differ significantly from standard cine results except for LV mass, which was slightly overestimated with deep learning cine. Deep learning cine sequences result in a significant reduction in scan time with only slightly lower image quality.

2.
Fetal Diagn Ther ; 50(1): 8-16, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36617416

RESUMO

INTRODUCTION: The aim of this study was to evaluate the feasibility of identifying the fetal cardiac and thoracic vascular structures with non-gated dynamic balanced steady-state free precession (SSFP) MRI sequences. METHODS: We retrospectively assessed the visibility of cardiovascular anatomy in 60 fetuses without suspicion of congenital heart defect. Non-gated dynamic balanced SSFP sequences were acquired in three anatomic planes of the fetal thorax. The images were analyzed following a segmental approach in consensus reading by an experienced pediatric cardiologist and radiologist. An imaging score was defined by giving one point to each visualized structure, yielding a maximum score of 21 points. Image quality was rated from 0 (poor) to 2 (excellent). The influence of gestational age (GA), field strength, placenta position, and maternal panniculus on image quality and imaging score were tested. RESULTS: 30 scans were performed at 1.5T, 30 at 3T. Heart position, atria, and ventricles could be seen in all 60 fetuses. Basic diagnosis (>12 points) was achieved in 54 cases. The mean imaging score was 16.8+/-3.8. Maternal panniculus (r = -0.3; p = 0.015) and GA (r = 0.6; p < 0.001) correlated with imaging score. Field strength influenced image quality, with 1.5T being better than 3T images (p = 0.012). Imaging score or quality was independent of placenta position. CONCLUSION: Fetal cardiac MRI with non-gated SSFP sequences enables recognition of basic cardiovascular anatomy.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Gravidez , Criança , Feminino , Humanos , Estudos Retrospectivos , Estudos de Viabilidade , Imageamento por Ressonância Magnética/métodos , Feto , Cardiopatias Congênitas/diagnóstico por imagem
3.
BMC Med Imaging ; 22(1): 169, 2022 09 27.
Artigo em Inglês | MEDLINE | ID: mdl-36167535

RESUMO

PURPOSE: To find the best level to measure aortic flow for quantification of aortic regurgitation (AR) in 4D flow CMR. METHODS: In 27 congenital heart disease patients with AR (67% male, 31 ± 16 years) two blinded observers measured antegrade, retrograde, net aortic flow volumes and regurgitant fractions at 6 levels in 4D flow: (1) below the aortic valve (AV), (2) at the AV, (3) at the aortic sinus, (4) at the sinotubular junction, (5) at the level of the pulmonary arteries (PA) and (6) below the brachiocephalic trunk. 2D phase contrast (2DPC) sequences were acquired at the level of PA. All patients received prior transthoracic echocardiography (TTE) with AR severity grading according to a recommended multiparametric approach. RESULTS: After assigning 2DPC measurements into AR grading, agreement between TTE AR grading and 2DPC was good (κ = 0.88). In 4D flow, antegrade flow was similar between the six levels (p = 0.87). Net flow was higher at level 1-2 than at levels 3-6 (p < 0.05). Retrograde flow and regurgitant fraction at level 1-2 were lower compared to levels 3-6 (p < 0.05). Reproducibility (inter-reader agreement: ICC 0.993, 95% CI 0.986-0.99; intra-reader agreement: ICC 0.982, 95%CI 0.943-0.994) as well as measurement agreement between 4D flow and 2DPC (ICC 0.994; 95%CI 0.989 - 0.998) was best at the level of PA. CONCLUSION: For estimating severity of AR in 4D flow, best reproducibility along with best agreement with 2DPC measurements can be expected at the level of PA. Measurements at AV or below AV might underestimate AR.


Assuntos
Insuficiência da Valva Aórtica , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico por imagem , Feminino , Humanos , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Masculino , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
4.
Pediatr Radiol ; 52(5): 951-958, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35076727

RESUMO

BACKGROUND: Children with orofacial deformity may require repeated imaging of the facial skeleton. OBJECTIVE: To test the feasibility and accuracy of "black bone" magnetic resonance imaging (MRI) for assessing facial deformity in children. MATERIALS AND METHODS: Three-dimensional (3-D) black bone gradient echo sequences (flip angle 5°, submillimetre spatial resolution) from 10 children (median age: 13 years, range: 2-16 years), who underwent MRI of the temporomandibular joints, were evaluated with multiplanar reconstruction and 3-D rendering tools. Intra- and inter-reader agreement was investigated for measuring the height of the mandibular ramus and condyle, basal length of the mandible, gonion angle and mandibular inclination angle by intraclass correlation coefficient (ICC) and Bland-Altman analysis. Absolute percentage error was calculated with the average of all measurements serving as reference. RESULTS: Sixty linear and 40 angle measurements were obtained on reformatted multiplanar black bone images with excellent inter-reader agreement (ICC > 0.99, agreement bias < 1.4 mm/ < 1.5°) and small error (median absolute error < 3%). The black bone images required inversion of the signal intensity and removal of air before they could be processed with standard volume rendering tools. The diagnostic utility of 3-D views for assessing the facial skeleton was sufficient except for assessing dental relationship. CONCLUSION: Morphometric measurements of the mandible can be obtained from black bone MRI with comparable inter-rater agreement to that reported for cone beam computed tomography (CT). With improvements of 3-D rendering techniques and software, black bone MRI may become a radiation-free alternative to CT in children with facial deformities.


Assuntos
Mandíbula , Crânio , Adolescente , Criança , Tomografia Computadorizada de Feixe Cônico/métodos , Cabeça , Humanos , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Mandíbula/diagnóstico por imagem
5.
Eur Radiol ; 31(10): 7231-7241, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33783570

RESUMO

OBJECTIVES: To use 4D-flow MRI to describe systemic and non-systemic ventricular flow organisation and energy loss in patients with repaired d-transposition of the great arteries (d-TGA) and normal subjects. METHODS: Pathline tracking of ventricular volumes was performed using 4D-flow MRI data from a 1.5-T GE Discovery MR450 scanner. D-TGA patients following arterial switch (n = 17, mean age 14 ± 5 years) and atrial switch (n = 15, 35 ± 6 years) procedures were examined and compared with subjects with normal cardiac anatomy and ventricular function (n = 12, 12 ± 3 years). Pathlines were classified by their passage through the ventricles as direct flow, retained inflow, delayed ejection flow, and residual volume and visually and quantitatively assessed. Additionally, viscous energy losses (ELv) were calculated. RESULTS: In normal subjects, the ventricular flow paths were well ordered following similar trajectories through the ventricles with very little mixing of flow components. The flow paths in all atrial and some arterial switch patients were more irregular with high mixing. Direct flow and delayed ejection flow were decreased in atrial switch patients' systemic ventricles with a corresponding increase in residual volume compared with normal subjects (p = 0.003 and p < 0.001 respectively) and arterial switch patients (p < 0.0001 and p < 0.001 respectively). In non-systemic ventricles, arterial switch patients had increased direct flow and decreased delayed ejection fractions compared to normal (p = 0.007 and p < 0.001 respectively) and atrial switch patients (p = 0.01 and p < 0.001 respectively). Regions of high levels of mixing of ventricular flow components showed elevated ELv. CONCLUSIONS: 4D-flow MRI pathline tracking reveals disordered ventricular flow patterns and associated ELv in d-TGA patients. KEY POINTS: • 4D-flow MRI can be used to assess intraventricular flow dynamics in d-TGA patients. • d-TGA arterial switch patients mostly show intraventricular flow dynamics representative of normal subjects, while atrial switch patients show increased flow disorder and different proportions of intraventricular flow volumes. • Flow disruption and disorder increase viscous energy losses.


Assuntos
Transposição dos Grandes Vasos , Adolescente , Adulto , Artérias , Criança , Átrios do Coração , Ventrículos do Coração/diagnóstico por imagem , Humanos , Imageamento por Ressonância Magnética , Transposição dos Grandes Vasos/diagnóstico por imagem , Transposição dos Grandes Vasos/cirurgia , Adulto Jovem
6.
Pediatr Radiol ; 51(8): 1503-1517, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33313980

RESUMO

Cardiovascular MRI has become an essential imaging modality in children with congenital heart disease (CHD) in the last 15-20 years. With use of appropriate sequences, it provides important information on cardiovascular anatomy, blood flow and function for initial diagnosis and post-surgical or -interventional monitoring in children. Although considered as more sophisticated and challenging than CT, in particular in neonates and infants, MRI is able to provide information on intra- and extracardiac haemodynamics, in contrast to CT. In recent years, four-dimensional (4-D) flow MRI has emerged as an additional MR technique for retrospective assessment and visualisation of blood flow within the heart and any vessel of interest within the acquired three-dimensional (3-D) volume. Its application in young children requires special adaptations for the smaller vessel size and faster heart rate compared to adolescents or adults. In this article, we provide an overview of 4-D flow MRI in various types of complex CHD in neonates and infants to demonstrate its potential indications and beneficial application for optimised individual cardiovascular assessment. We focus on its application in clinical routine cardiovascular workup and, in addition, show some examples with pathologies other than CHD to highlight that 4-D flow MRI yields new insights in disease understanding and therapy planning. We shortly review the essentials of 4-D flow data acquisition, pre- and post-processing techniques in neonates, infants and young children. Finally, we conclude with some details on accuracy, limitations and pitfalls of the technique.


Assuntos
Cardiopatias Congênitas , Imageamento por Ressonância Magnética , Adolescente , Adulto , Criança , Pré-Escolar , Coração , Cardiopatias Congênitas/diagnóstico por imagem , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos
7.
Magn Reson Med ; 83(6): 2264-2275, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31742787

RESUMO

PURPOSE: To analyze the dependence of flow volume measurements on 3D cine phase-contrast MRI (4D-flow MRI) background phase correction. METHODS: In 31 subjects scanned on a 1.5T MRI scanner, flow volume measurements at 4 vessels were made using phantom corrected 2D phase contrast and 4D flow with background phase correction performed by linear, second, third, and fourth-order polynomial fitting to static tissue. Variations in the amount and distribution of static tissue were made to investigate the influence on flow volume measurements. RESULTS: Bland Altman comparison of 2D phase-contrast and 4D-flow measurements showed low bias (2.3%-4.8%) and relatively large limits of agreement (13.5%-17.6%). Approximately half of this was attributable to sequence and physiological differences between the 2 scan sequences, demonstrated by smaller limits of agreement (5.3%-10.0%) when comparing 4D-flow measurements with differing background phase corrections. Using only 20% of available static tissue points for polynomial fitting resulted in only 1% difference in flow volume measurements. Using asymmetrically distributed static tissue or including nonstatic tissue for polynomial fitting yielded highly variable differences in flow volume measurements, which became more variable with increased polynomial order. Completely asymmetric static tissue selection resulted in high deviations in flow volume measurements (mean > 7%, max = 345%). CONCLUSION: Comparisons between 2D phase-contrast and 4D-flow volume measurements should consider influences from sequence and physiological differences. A subset of static tissue points may be used with low impact on flow measurements, but should avoid the inclusion of nonstatic tissue and avoid asymmetric distribution. Higher-order polynomial fits are more susceptible to inaccurate static tissue selection.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Algoritmos , Velocidade do Fluxo Sanguíneo , Humanos , Imageamento Tridimensional , Imagens de Fantasmas , Reprodutibilidade dos Testes
8.
J Magn Reson Imaging ; 49(1): 90-100, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30102443

RESUMO

BACKGROUND: Abnormal flow dynamics play an early and causative role in pathologic changes of the ascending aorta. PURPOSE: To identify: 1) the changes in flow, shape, and size that occur in the ascending aorta with normal human ageing and 2) the influence of these factors on aortic flow dynamics. STUDY TYPE: Retrospective. SUBJECTS: In all, 247 subjects (age range 19-86 years, mean 49 ± 17.7, 169 males) free of aortic or aortic valve pathology were included in this study. Subjects were stratified by youngest (18-33 years; n = 64), highest (>60 years, n = 67), and the middle two quartiles (34-60 years, n = 116). FIELD STRENGTH/SEQUENCE: Subjects underwent a cardiac MRI (3T) exam including 4D-flow MRI of the aorta. ASSESSMENT: Aortic curvature, arch shape, ascending aortic angle, ascending aortic diameter, and the stroke volume normalized by the aortic volume (nSV) were measured. Velocity, vorticity, and helicity were quantified across the thoracic aorta. STATISTICAL TESTS: Univariate and multivariate regressions were used to quantify continuous relationships between variables. RESULTS: Aortic diameter, ascending aortic angle, shape, and curvature all increased across age while nSV decreased (all P < 0.0001). Systolic vorticity in the mid arch decreased by 50% across the age range (P < 0.0001), while peak helicity decreased by 80% (P < 0.0001). Curvature tightly governs optimal flow in the youngest quartile, with an effect size 1.5 to 4 times larger than other parameters in the descending aorta, but had a minimal influence with advancing age. In the upper quartile of age, flow dynamics were almost completely determined by nSV, exerting an effect size on velocity and vorticity >10 times that of diameter and other shape factors. DATA CONCLUSION: Aortic shape influences flow dynamics in younger subjects. Flow conditions become increasingly disturbed with advancing age, and in these conditions nSV has a more dominant effect on flow patterns than shape factors. LEVEL OF EVIDENCE: 3 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:90-100.


Assuntos
Envelhecimento , Aorta/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
9.
Am J Physiol Heart Circ Physiol ; 315(5): H1174-H1181, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-30028202

RESUMO

Wall shear stress (WSS) plays a governing role in vascular remodeling and a pathogenic role in vessel wall diseases. However, little is known of the normal WSS patterns in the aorta as there is currently no practical means to routinely measure WSS and no normal ranges derived from population data exist. WSS measurements were made on the aorta of 224 subjects with normal anatomy using four-dimensional flow MRI with multiple encoding velocities and an optimized postprocessing routine. The spatial and temporal variation in WSS and oscillatory shear index was analyzed using a flat map representation of the unfolded aorta. The influence of aortic shape and velocity on WSS was evaluated using regression analysis. WSS in the thoracic aorta is dominated by axial flow. Average peak systolic WSS was 1.79 ± 0.71 Pa in the aortic arch and was significantly higher at 2.23 ± 1.04 Pa in the descending aorta, with a strong negative correlation with advancing age. The spatial distribution of WSS is highly heterogeneous, with a localized region of elevated WSS along the length of the anterior wall seen across all individuals. Our data demonstrate that accurate four-dimensional flow-derived WSS measurement is feasible, and we further provide a standardized parametric approach for presentation and analysis. We present a normal range for WSS across the lifespan, demonstrating a decrease in WSS with advancing age as well as illustrating the high degree of spatial and temporal variation. NEW & NOTEWORTHY With the use of four-dimensional flow MRI and postprocessing, accurate direct measurement of wall shear stress (WSS) was performed in a population of normal thoracic aortas ( n = 224). WSS was higher in the descending aorta compared with the aortic arch and decreased with age. A heterogeneous pattern of elevated WSS along the length of the aorta anterior wall was consistent across the population. This work provides normal data across the adult age range, permitting comparison with pathology.


Assuntos
Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiologia , Hemodinâmica , Interpretação de Imagem Assistida por Computador/métodos , Angiografia por Ressonância Magnética/métodos , Imagem de Perfusão/métodos , Adulto , Idoso , Velocidade do Fluxo Sanguíneo , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , New South Wales , Valor Preditivo dos Testes , Estudos Prospectivos , Valores de Referência , Fluxo Sanguíneo Regional , Reprodutibilidade dos Testes , Estresse Mecânico , Fatores de Tempo
10.
Magn Reson Med ; 78(5): 1959-1968, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-27885707

RESUMO

PURPOSE: 4D-flow MRI obtains a time-dependent 3D velocity field; however, its use for the calculation of higher-order parameters is limited by noise. We present an algorithm for denoising 4D-flow data. THEORY AND METHODS: By integrating a velocity field and eliminating streamlines in noisy flow, depicted by high curvature, a denoised dataset may be extracted. This method, defined as the velocity field improvement (VFIT) algorithm, was validated in an analytical dataset and using in vivo data in comparison with a computation fluid dynamics (CFD) simulation. As a proof of principal, wall shear stress (WSS) measurements in the descending aorta were compared with those defined by CFD. RESULTS: The VFIT algorithm achieved a >100% noise reduction of a corrupted analytical dataset. In addition, 4D-flow data were cleaned to show improved spatial resolution and near wall velocity representation. WSS measures compared well with CFD data and bulk flow dynamics were retained (<2% difference in flow measurements). CONCLUSION: This study presents a method for denoising 4D-flow datasets with improved spatial resolution. Bulk flow dynamics are accurately conserved while velocity and velocity gradient fields are improved; this is important in the calculation of higher-order parameters such as WSS, which are shown to be more comparable to CFD measures. Magn Reson Med 78:1959-1968, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Aorta Torácica/diagnóstico por imagem , Velocidade do Fluxo Sanguíneo , Simulação por Computador , Humanos , Masculino
11.
J Magn Reson Imaging ; 45(4): 1046-1054, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-27626621

RESUMO

PURPOSE: To quantitatively characterize the central role of vortex formation on the flow patterns and energy transfer within the right atrium (RA). MATERIALS AND METHODS: 4D-flow magnetic resonance imaging (MRI) data with multiple encoding velocities was acquired in 12 healthy subjects at 3T. Particles entering the RA were classified according to the origin of entry. Vortex membership was numerically derived by assessing the location of pathline center of curvature relative to the vortex core, defined by Q-criteria. Flow dynamics and energetics were assessed using paired t-tests. RESULTS: The majority of flow (74%) passes through the RA in a single beat, with a very small volume fraction retained longer than two beats (<1%). RA flow was dominated by a governing vortex, comprising 79% of total flow, and acting to preserve kinetic energy. Flow comprising the vortex enters the RA significantly earlier than nonvortex flow (P < 0.01). The majority of nonvortex flow enters the RA during systole, traversing the RA via a direct path with a significantly shorter residence time and distance traveled (both P < 0.01). CONCLUSION: Blood flow momentum is preserved during systole within a dominant vortex, which we are able to characterize numerically using a semiautomated approach. Our analytical approach has potential for application to understanding right heart function in health and disease. LEVEL OF EVIDENCE: 1 J. Magn. Reson. Imaging 2017;45:1046-1054.


Assuntos
Coração/diagnóstico por imagem , Coração/fisiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Função Atrial , Feminino , Coração/fisiopatologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
12.
BMC Musculoskelet Disord ; 18(1): 406, 2017 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-28950859

RESUMO

BACKGROUND: Femoroacetabular impingement syndrome (FAI), a hip disorder affecting active young adults, is believed to be a leading cause of hip osteoarthritis (OA). Current management approaches for FAI include arthroscopic hip surgery and physiotherapy-led non-surgical care; however, there is a paucity of clinical trial evidence comparing these approaches. In particular, it is unknown whether these management approaches modify the future risk of developing hip OA. The primary objective of this randomised controlled trial is to determine if participants with FAI who undergo hip arthroscopy have greater improvements in hip cartilage health, as demonstrated by changes in delayed gadolinium-enhanced magnetic resonance imaging (MRI) of cartilage (dGEMRIC) index between baseline and 12 months, compared to those who undergo physiotherapy-led non-surgical management. METHODS: This is a pragmatic, multi-centre, two-arm superiority randomised controlled trial comparing hip arthroscopy to physiotherapy-led management for FAI. A total of 140 participants with FAI will be recruited from the clinics of participating orthopaedic surgeons, and randomly allocated to receive either surgery or physiotherapy-led non-surgical care. The surgical intervention involves arthroscopic FAI surgery from one of eight orthopaedic surgeons specialising in this field, located in three different Australian cities. The physiotherapy-led non-surgical management is an individualised physiotherapy program, named Personalised Hip Therapy (PHT), developed by a panel to represent the best non-operative care for FAI. It entails at least six individual physiotherapy sessions over 12 weeks, and up to ten sessions over six months, provided by experienced musculoskeletal physiotherapists trained to deliver the PHT program. The primary outcome measure is the change in dGEMRIC score of a ROI containing both acetabular and femoral head cartilages at the chondrolabral transitional zone of the mid-sagittal plane between baseline and 12 months. Secondary outcomes include patient-reported outcomes and several structural and biomechanical measures relevant to the pathogenesis of FAI and development of hip OA. Interventions will be compared by intention-to-treat analysis. DISCUSSION: The findings will help determine whether hip arthroscopy or an individualised physiotherapy program is superior for the management of FAI, including for the prevention of hip OA. TRIAL REGISTRATION: Australia New Zealand Clinical Trials Registry reference: ACTRN12615001177549 . Trial registered 2/11/2015 (retrospectively registered).


Assuntos
Artroscopia/métodos , Impacto Femoroacetabular/epidemiologia , Impacto Femoroacetabular/terapia , Articulação do Quadril/cirurgia , Modalidades de Fisioterapia , Austrália/epidemiologia , Feminino , Impacto Femoroacetabular/diagnóstico por imagem , Articulação do Quadril/diagnóstico por imagem , Humanos , Masculino , Método Simples-Cego , Resultado do Tratamento
13.
Cardiovasc Diabetol ; 15(1): 164, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28007022

RESUMO

BACKGROUND: Diastolic dysfunction is a major cause of morbidity in obese individuals. We aimed to assess the ability of magnetic resonance imaging (MRI) derived left atrial (LA) strain to detect early diastolic dysfunction in individuals with obesity and type 2 diabetes, and to explore the association between cardiac adipose tissue and LA function. METHODS: Twenty patients with obesity and T2D (55 ± 8 years) and nineteen healthy controls (48 ± 13 years) were imaged using cine steady state free precession and 2-point Dixon cardiovascular magnetic resonance. LA function was quantified using a feature tracking technique with definition of phasic longitudinal strain and strain rates, as well as radial motion fraction and radial velocities. RESULTS: Systolic left ventricular size and function were similar between the obesity and type 2 diabetes and control groups by MRI. All patients except four had normal diastolic assessment by echocardiography. In contrast, measures of LA function using magnetic resonance feature tracking were uniformly altered in the obesity and type 2 diabetes group only. Although there was no significant difference in intra-myocardial fat fraction, Dixon 3D epicardial fat volume(EFV) was significantly elevated in the obesity and type 2 diabetes versus control group (135 ± 31 vs. 90 ± 30 mL/m2, p < 0.001). There were significant correlations between LA functional indices and both BMI and EFV (p ≤ 0.007). CONCLUSIONS: LA MRI-strain may be a sensitive tool for the detection of early diastolic dysfunction in individuals with obesity and type 2 diabetes and correlated with BMI and epicardial fat supporting a possible association between adiposity and LA strain. Trials Registration Australian New Zealand Clinical Trials Registry No. ACTRN12613001069741.


Assuntos
Tecido Adiposo/diagnóstico por imagem , Função do Átrio Esquerdo , Diabetes Mellitus Tipo 2/complicações , Cardiopatias/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Obesidade/complicações , Pericárdio/diagnóstico por imagem , Tecido Adiposo/fisiopatologia , Adiposidade , Adulto , Algoritmos , Estudos de Casos e Controles , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Diástole , Diagnóstico Precoce , Feminino , Cardiopatias/etiologia , Cardiopatias/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Obesidade/fisiopatologia , Pericárdio/fisiopatologia , Valor Preditivo dos Testes , Fatores de Risco , Função Ventricular Esquerda
14.
J Magn Reson Imaging ; 43(2): 352-63, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26130421

RESUMO

PURPOSE: To show that the use of a multi-velocity encoding (VENC) 4D-flow approach offers significant improvements in the characterization of complex flow in the aorta. Four-dimensional flow magnetic resonance imaging (MRI) (4D-flow) can be used to measure complex flow patterns and dynamics in the heart and major vessels. The quality of the information derived from these measures is dependent on the accuracy of the vector field, which is limited by the vector-to-noise ratio. MATERIALS AND METHODS: A 4D-flow protocol involving three different VENC values of 150, 60, and 20 cm/s was performed on six control subjects and nine patients with type-B chronic aortic dissection at 3T MRI. Data were processed using a single VENC value (150 cm/s) or using a fused dataset that selected the lowest appropriate VENC for each voxel. Performance was analyzed by measuring spatial vector angular correlation, magnitude correlation, temporal vector conservation, and "real-world" streamline tracing performance. RESULTS: The multi-VENC approach provided a 31% improvement in spatial and 53% improvement in temporal precision of velocity vector measurements during the mid-late diastolic period, where 99% of the flow vectors in the normal aorta are below 20 cm/s. In low-flow conditions this resulted in practical improvements of greater than 50% in pathline tracking and streamline tracing quantified by streamline curvature measurements. CONCLUSION: A multi-VENC 4D-flow approach provides accurate vector data across normal physiological velocities observed in the aorta, dramatically improving outputs such as pathline tracking, streamline estimation, and further advanced analyses.


Assuntos
Aorta/fisiopatologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
15.
Am J Physiol Heart Circ Physiol ; 300(4): H1451-8, 2011 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21297030

RESUMO

Spontaneous internal carotid artery (ICA) dissection (sICAD) results from an intimal tear located around the distal carotid sinus. The mechanisms causing the tear are unknown. This case-control study tested the hypotheses that head movements increase the wall stress in the cervical ICA and that the stress increase is greater in patients with sICAD than in controls. Five patients with unilateral, recanalized, left sICAD and five matched controls were investigated before and after maximal head rotation to the left and neck hyperextension after 45° head rotation to the left. The anatomy of the extracranial carotid arteries was assessed by magnetic resonance imaging and used to create finite element models of the right ICA. Wall stress increased after head movements. Increases above the 80th and 90th percentile were located at the intimal side of the artery wall from 7.4 mm below to 10 mm above the cranial edge of the carotid sinus, i.e., at the same location as histologically confirmed tears in patients with sICAD. Wall stress increase did not differ between patients and controls. The present findings suggest that wall stress increases at the intimal side of the artery wall surrounding the distal edge of the carotid bulb after head movements may be important for the development of carotid dissection. The lack of wall stress difference between the two groups indicates that the carotid arteries of patients with carotid dissection have either distinct functional or anatomical properties or endured unusually heavy wall stresses to initiate dissection.


Assuntos
Dissecação da Artéria Carótida Interna/fisiopatologia , Estresse Fisiológico/fisiologia , Artéria Carótida Interna/fisiopatologia , Estudos de Casos e Controles , Feminino , Análise de Elementos Finitos , Movimentos da Cabeça/fisiologia , Humanos , Imageamento por Ressonância Magnética , Masculino , Modelos Cardiovasculares
17.
Sci Rep ; 9(1): 2418, 2019 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-30787303

RESUMO

The hippocampus is a key component of emotional and memory circuits and is broadly connected throughout the brain. We tracked the whole-brain connections of white matter fibres from the hippocampus using ultra-high angular resolution diffusion MRI in both a single 1150-direction dataset and a large normal cohort (n = 94; 391-directions). Using a connectomic approach, we identified six dominant pathways in terms of strength, length and anatomy, and characterised them by their age and gender variation. The strongest individual connection was to the ipsilateral thalamus. There was a strong age dependence of hippocampal connectivity to medial occipital regions. Overall, our results concur with preclinical and ex-vivo data, confirming that meaningful in vivo characterisation of hippocampal connections is possible in an individual. Our findings extend the collective knowledge of hippocampal anatomy, highlighting the importance of the spinal-limbic pathway and the striking lack of hippocampal connectivity with motor and sensory cortices.


Assuntos
Encéfalo/metabolismo , Conectoma , Hipocampo/metabolismo , Lobo Temporal/metabolismo , Adolescente , Adulto , Encéfalo/diagnóstico por imagem , Encéfalo/fisiologia , Imagem de Difusão por Ressonância Magnética , Emoções/fisiologia , Feminino , Hipocampo/diagnóstico por imagem , Hipocampo/fisiologia , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Memória/fisiologia , Vias Neurais/metabolismo , Lobo Temporal/diagnóstico por imagem , Lobo Temporal/fisiologia , Tálamo/diagnóstico por imagem , Tálamo/metabolismo , Tálamo/fisiologia , Substância Branca/diagnóstico por imagem , Substância Branca/metabolismo , Substância Branca/fisiologia , Adulto Jovem
18.
Asian Cardiovasc Thorac Ann ; 26(1): 28-37, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28185475

RESUMO

Imaging-based evaluation of cardiac structure and function remains paramount in the diagnosis and monitoring of congenital heart disease in childhood. Accurate measurements of intra- and extracardiac hemodynamics are required to inform decision making, allowing planned timing of interventions prior to deterioration of cardiac function. Four-dimensional flow magnetic resonance imaging is a nonionizing noninvasive technology that allows accurate and reproducible delineation of blood flow at any anatomical location within the imaging volume of interest, and also permits derivation of physiological parameters such as kinetic energy and wall shear stress. Four-dimensional flow is the focus of a great deal of attention in adult medicine, however, the translation of this imaging technique into the pediatric population has been limited to date. A more broad-scaled application of 4-dimensional flow in pediatric congenital heart disease stands to increase our fundamental understanding of the cause and significance of abnormal blood flow patterns, may improve risk stratification, and inform the design and use of surgical and percutaneous correction techniques. This paper seeks to outline the application of 4-dimensional flow in the assessment and management of the pediatric population affected by congenital heart disease.


Assuntos
Cardiopatias Congênitas/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Imagem de Perfusão do Miocárdio/métodos , Adolescente , Adulto , Fatores Etários , Criança , Pré-Escolar , Feminino , Cardiopatias Congênitas/fisiopatologia , Cardiopatias Congênitas/terapia , Hemodinâmica , Humanos , Lactente , Recém-Nascido , Masculino , Valor Preditivo dos Testes , Prognóstico , Reprodutibilidade dos Testes , Adulto Jovem
19.
J Biomech ; 79: 39-44, 2018 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-30104052

RESUMO

Peripheral veno-arterial extra corporeal membrane oxygenation (VA-ECMO) is an established technique for short-to-medium support of patients with severe cardiac failure. However, in patients with concomitant respiratory failure, the residual native circulation will provide deoxygenated blood to the upper body, and may cause differential hypoxemia of the heart and brain. In this paper, we present a general computational framework for the identification of differential hypoxemia risk in VA-ECMO patients. A range of different VA-ECMO patient scenarios for a patient-specific geometry and vascular resistance were simulated using transient computational fluid dynamics simulations, representing a clinically relevant range of values of stroke volume and ECMO flow. For this patient, regardless of ECMO flow rate, left ventricular stroke volumes greater than 28 mL resulted in all aortic arch branch vessels being perfused by poorly-oxygenated systemic blood sourced from the lungs. The brachiocephalic artery perfusion was almost entirely derived from blood from the left ventricle in all scenarios except for those with stroke volumes less than 5 mL. Our model therefore predicted a strong risk of differential hypoxemia in nearly all situations with some residual cardiac function for this combination of patient geometry and vascular resistance. This simulation highlights the potential value of modelling for optimising ECMO design and procedures, and for the practical utility for personalised approaches in the clinical use of ECMO.


Assuntos
Oxigenação por Membrana Extracorpórea , Insuficiência Cardíaca/complicações , Hipóxia/etiologia , Modelos Cardiovasculares , Insuficiência Respiratória/complicações , Adulto , Insuficiência Cardíaca/terapia , Humanos , Hidrodinâmica , Masculino
20.
Aorta (Stamford) ; 5(3): 80-90, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29675440

RESUMO

BACKGROUND: Chronic descending thoracic aortic dissection (CDTAD) following surgical repair of ascending aortic dissection requires long-term imaging surveillance. We investigated four-dimensional (4D)-flow magnetic resonance imaging (MRI) with a novel multi-velocity encoding (multi-VENC) technique as an emerging clinical method enabling the dynamic quantification of blood volume and velocity throughout the cardiac cycle. METHODS: Patients with CDTAD (n = 10; mean age, 55.1 years; standard deviation (SD) 10.8) and healthy volunteers (n = 9; mean age, 37.1 years; SD 11.4; p < 0.01) underwent 3T MRI, and standard views and 4D-flow data were obtained. Flow measurements were made in selected regions of interest within the ascending and descending thoracic aorta. RESULTS: The overall flow profile at peak systole was reduced in the false lumen (FL) compared with the true lumen (TL) and normal aortas (p < 0.05 for velocity < 0.4 m/s). Peak systolic flow rate per aortic lumen area (mL/s/cm2) was lower in the FL than in the TL (p < 0.05), and both rates were lower than that of control aortas (p < 0.05). Blood flow reversal was higher in the FL than in the TL throughout the descending aorta in CDTAD patients (p < 0.05). A derived pulsatility index was elevated in the TL compared with that in the FL in CDTAD patients. Generated pathline images demonstrated flow patterns in detail, including sites of communication between the true and FL. CONCLUSIONS: 4D-flow MRI revealed FL blood flow and reduced blood flow velocity and flow rate in the TL of CDTAD patients compared with normal aortas of healthy participants. Thus, multi-VENC 4D-flow MRI could serve as an adjunct in the long-term assessment of CDTAD following surgical repair of ascending aortic dissection.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA