Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 62
Filtrar
1.
J Mater Sci Mater Med ; 32(10): 131, 2021 Oct 09.
Artigo em Inglês | MEDLINE | ID: mdl-34625853

RESUMO

Bypass grafting is a technique used in the treatment of vascular disease, which is currently the leading cause of mortality worldwide. While technology has moved forward over the years, synthetic grafts still show significantly lower rates of patency in small diameter bypass operations compared to the gold standard (autologous vessel grafts). Scaffold morphology plays an important role in vascular smooth muscle cell (VSMC) performance, with studies showing how fibre alignment and surface roughness can modulate phenotypic and genotypic changes. Herein, this study has looked at how the fibre diameter of electrospun polymer scaffolds can affect the performance of seeded VSMCs. Four different scaffolds were electrospun with increasing fibre sizes ranging from 0.75 to 6 µm. Culturing VSMCs on the smallest fibre diameter (0.75 µm) lead to a significant increase in cell viability after 12 days of culture. Furthermore, interesting trends were noted in the expression of two key phenotypic genes associated with mature smooth muscle cell contractility (myocardin and smooth muscle alpha-actin 1), whereby reducing the fibre diameter lead to relative upregulations compared to the larger fibre diameters. These results showed that the smallest (0.75 µm) fibre diameter may be best suited for the culture of VSMCs with the aim of increasing cell proliferation and aiding cell maturity.


Assuntos
Prótese Vascular , Músculo Liso Vascular/efeitos dos fármacos , Miócitos de Músculo Liso/efeitos dos fármacos , Nanofibras , Alicerces Teciduais/química , Diferenciação Celular/efeitos dos fármacos , Proliferação de Células/efeitos dos fármacos , Células Cultivadas , Galvanoplastia , Fluorocarbonos/química , Fluorocarbonos/farmacologia , Humanos , Teste de Materiais , Músculo Liso Vascular/citologia , Miócitos de Músculo Liso/citologia , Miócitos de Músculo Liso/fisiologia , Nanofibras/química , Tamanho da Partícula , Poliésteres/química , Poliésteres/farmacologia , Porosidade
2.
Arch Toxicol ; 92(10): 3117-3129, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30155720

RESUMO

Liver disease is an escalating global health issue. While liver transplantation is an effective mode of therapy, patient mortality has increased due to the shortage of donor organs. Developing renewable sources of human liver tissue is therefore attractive. Pluripotent stem cell-derived liver tissue represents a potential alternative to cadaver derived hepatocytes and whole organ transplant. At present, two-dimensional differentiation procedures deliver tissue lacking certain functions and long-term stability. Efforts to overcome these limiting factors have led to the building of three-dimensional (3D) cellular aggregates. Although enabling for the field, their widespread application is limited due to their reliance on variable biological components. Our studies focused on the development of 3D liver tissue under defined conditions. In vitro generated 3D tissues exhibited stable phenotype for over 1 year in culture, providing an attractive resource for long-term in vitro studies. Moreover, 3D derived tissue provided critical liver support in two animal models, including immunocompetent recipients. Therefore, we believe that our study provides stable human tissue to better model liver biology 'in the dish', and in the future may permit the support of compromised liver function in humans.


Assuntos
Transplante de Fígado/métodos , Fígado/citologia , Células-Tronco Pluripotentes/citologia , Engenharia Tecidual/métodos , Animais , Técnicas de Cultura de Células , Diferenciação Celular , Endoderma/citologia , Feminino , Hepatectomia , Humanos , Fígado/fisiologia , Masculino , Camundongos Endogâmicos C57BL , Camundongos Knockout , Células-Tronco Pluripotentes/fisiologia , Esferoides Celulares/citologia , Fatores de Tempo , Alicerces Teciduais
3.
Int Urogynecol J ; 24(12): 2105-10, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23812578

RESUMO

INTRODUCTION AND HYPOTHESIS: Tissue-engineered biomaterials have shown recent promise as adjuvant scaffolds for treating stress urinary incontinence (SUI). The objective of the present study was to compare their mechanical and regenerative properties with synthetic biomaterials in this urogynaecological setting. METHODS: The biomechanical properties of polypropylene (Serasis®; n = 12), four-ply urinary bladder matrix (UBM; n = 12) and four-ply small intestinal submucosa (SIS; n = 12) were determined with uni-axial tensile testing protocols and compared with stress-strain curves. Subsequently, human dermal fibroblasts (2.5 × 10(4)cells/cm(2)) were cultured onto each biomaterial under conventional laboratory growth conditions for 12 consecutive days. Attachment, viability, and proliferative activity of fibroblasts were evaluated and compared using quantitative viability indicators and scanning electron microscopy. RESULTS: There were no significant differences in the biomechanical properties of each biomaterial assessed. Incremental stiffness at 0-10 % strain measured 5.73 ± 0.36 MPa for polypropylene compared with 8.23 ± 0.92 MPa and 6.81 ± 0.83 MPa for SIS and UBM respectively (p > 0.05). Viability and proliferative activity of fibroblasts differed significantly on all three biomaterials with the luminal and abluminal surfaces of the UBM demonstrating significantly greater rates of fibroblast proliferation compared with polypropylene and SIS (p < 0.01). CONCLUSION: This is the first comparative study on porcine UBM, porcine SIS, and synthetic polypropylene as adjuvant scaffolds for the treatment of SUI. Our results demonstrate that porcine UBM may provide an attractive alternative owing to its superior remodelling potential.


Assuntos
Matriz Extracelular/fisiologia , Mucosa Intestinal/fisiologia , Alicerces Teciduais , Bexiga Urinária/fisiologia , Animais , Materiais Biocompatíveis , Fenômenos Biomecânicos , Proliferação de Células , Sobrevivência Celular , Matriz Extracelular/ultraestrutura , Fibroblastos/fisiologia , Humanos , Mucosa Intestinal/ultraestrutura , Teste de Materiais , Polipropilenos , Telas Cirúrgicas , Suínos , Resistência à Tração , Bexiga Urinária/ultraestrutura , Incontinência Urinária por Estresse/terapia
4.
Biomimetics (Basel) ; 8(2)2023 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-37218791

RESUMO

The limited regenerative capacity of the human body, in conjunction with a shortage of healthy autologous tissue, has created an urgent need for alternative grafting materials. A potential solution is a tissue-engineered graft, a construct which supports and integrates with host tissue. One of the key challenges in fabricating a tissue-engineered graft is achieving mechanical compatibility with the graft site; a disparity in these properties can shape the behaviour of the surrounding native tissue, contributing to the likelihood of graft failure. The purpose of this review is to examine the means by which researchers have altered the mechanical properties of tissue-engineered constructs via hybrid material usage, multi-layer scaffold designs, and surface modifications. A subset of these studies which has investigated the function of their constructs in vivo is also presented, followed by an examination of various tissue-engineered designs which have been clinically translated.

5.
Front Bioeng Biotechnol ; 11: 1233801, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37650040

RESUMO

Background: Increased cancer rates denote that one in two people will be diagnosed with cancer in their lifetime. Over 60% of cancer patients receive radiotherapy, either as a stand-alone treatment or in combination with other treatments such as chemotherapy and surgery. Whilst radiotherapy is effective in destroying cancer cells, it also causes subsequent damage to healthy cells and surrounding tissue due to alterations in the tumor microenvironment and an increase in reactive oxygen species (ROS). This can cause extensive damage that impairs tissue function, and the likelihood of tissue regeneration and restoration of function is significantly reduced as new healthy cells cannot survive in the damaged environment. In the treatment of head and neck cancers, radiotherapy can cause salivary gland dysfunction. This significantly impairs the patient's quality of life and there is currently no cure, only palliative treatment options. Tissue engineering approaches are used to mimic the microenvironment of the tissue and can mediate the damaged microenvironment via bioactive compounds, to support the delivery, survival, and proliferation of new, healthy cells into the damaged environment. Methods: In this study, retinyl acetate, a derivative of vitamin A, was successfully incorporated into electrospun polycaprolactone fibres. Results: SEM images and characterization analyses showed that all scaffolds produced had similar characteristics, including fiber morphology and scaffold wettability. The vitamin scaffolds were shown to exert an antioxidant effect through scavenging activity of both DPPH and hydroxyl radicals in vitro. Critically, the antioxidant scaffolds supported the growth of human submandibular gland cells and significantly upregulated the expression of GPx1, an antioxidant enzyme, when cultured under both normal conditions and under a simulated oxidative stress environment. Discussion: These results suggest that incorporation of retinyl acetate into electrospun fibres has may mediate the damaged microenvironment post cancer radiation therapy.

6.
J Appl Polym Sci ; 140(32): e54242, 2023 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-38439767

RESUMO

Tissue engineering provides promise for regeneration of cardiac tissue following myocardial infarction. However, the harsh microenvironment of the infarct hampers the efficacy of regenerative therapies. Ischemia-reperfusion injury dramatically increases the levels of reactive oxygen species (ROS) within the infarcted area, causing a cascade of further cellular injury. Implantable tissue engineered grafts can target this oxidative stress by delivering pharmaceutical compounds directly into the diseased tissue. Herein, we successfully fabricated electrospun polycaprolactone (PCL) fibers containing varying concentrations of ascorbic acid, a potent antioxidant well known for its ROS-scavenging capabilities. The antioxidant scaffolds displayed significantly improved scavenging of DPPH radicals, superoxide anions and hydroxyl radicals, in a dose dependent manner. Mechanical properties testing indicated that incorporation of ascorbic acid enhanced the strength and Young's modulus of the material, correlating with a moderate but non-significant increase in the crystallinity. Moreover, the scaffolds supported adhesion and maintained survival of human umbilical vein endothelial cells in vitro, indicating good cytocompatibility. These results provide motivation for the use of ascorbic acid-containing fibrous scaffolds to regulate the highly oxidative microenvironment following myocardial infarction.

7.
ACS Appl Bio Mater ; 6(6): 2158-2171, 2023 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-37283498

RESUMO

Donor liver shortage is a crucial global public health problem as whole-organ transplantation is the only definitive cure for liver disease. Liver tissue engineering aims to reproduce or restore function through in vitro tissue constructs, which may lead to alternative treatments for active and chronic liver disease. The formulation of a multifunctional scaffold that has the potential to mimic the complex extracellular matrix (ECM) and their influence on cellular behavior, are essential for culturing cells on a construct. The separate employment of topographic or biological cues on a scaffold has both shown influences on hepatocyte survival and growth. In this study, we investigate both of these synergistic effects and developed a new procedure to directly blend whole-organ vascular perfusion-decellularized rat liver ECM (dECM) into electrospun fibers with tailored surface nanotopography. Water contact angle, tensile test, and degradation studies were conducted to analyze scaffold hydrophilicity, mechanical properties, and stability. The results show that our novel hybrid scaffolds have enhanced hydrophilicity, and the nanotopography retained its original form after hydrolytic degradation for 14 days. Human hepatocytes (HepG2) were seeded to analyze the scaffold biocompatibility. Cell viability and DNA quantification imply steady cell proliferation over the culture period, with the highest albumin secretion observed on the hybrid scaffold. Scanning electron microscopy shows that cell morphology was distinctly different on hybrid scaffolds compared to control groups, where HepG2 began to form a monolayer toward the end of the culture period; meanwhile, typical hepatic markers and ECM genes were also influenced, such as an increasing trend of albumin appearing on the hybrid scaffolds. Taken together, our findings provide a reproducible approach and utilization of animal tissue-derived ECM and emphasize the synergism of topographical stimuli and biochemical cues on electrospun scaffolds in liver tissue engineering.


Assuntos
Transplante de Fígado , Alicerces Teciduais , Ratos , Animais , Humanos , Alicerces Teciduais/química , Doadores Vivos , Fígado/cirurgia , Matriz Extracelular/química , Albuminas
8.
J Mech Behav Biomed Mater ; 139: 105665, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36640542

RESUMO

Reproducing both the mechanical and biological performance of native blood vessels remains an ongoing challenge in vascular tissue engineering. Additive-lathe printing offers an attractive method of fabricating long tubular constructs as a potential vascular graft for the treatment of cardiovascular diseases. Printing hydrogels onto rotating horizontal mandrels often leads to sagging, resulting in poor and variable mechanical properties. In this study, an additive-lathe printing system with a vertical mandrel to fabricate tubular constructs is presented. Various concentrations of gelatin methacryloyl (gelMA) hydrogel were used to print grafts on the rotating mandrel in a helical pattern. The printing parameters were selected to achieve the bonding of consecutive gelMA filaments to improve the quality of the printed graft. The hydrogel filaments were fused properly under the action of gravity on the vertical mandrel. Thus, the vertical additive-lathe printing system was used to print uniform wall thickness grafts, eliminating the hydrogel sagging problem. Tensile testing performed in both circumferential and longitudinal direction revealed that the anisotropic properties of printed gelMA constructs were similar to those observed in the native blood vessels. In addition, no leakage was detected through the walls of the gelMA grafts during burst pressure measurement. Therefore, the current printing setup could be utilized to print vascular grafts for the treatment of cardiovascular diseases.


Assuntos
Bioimpressão , Doenças Cardiovasculares , Humanos , Alicerces Teciduais , Hidrogéis , Impressão Tridimensional , Bioimpressão/métodos , Engenharia Tecidual/métodos , Gelatina , Metacrilatos
9.
Biomater Adv ; 145: 213250, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36563509

RESUMO

Regenerative medicine strategies place increasingly sophisticated demands on 3D biomaterials to promote tissue formation at sites where tissue would otherwise not form. Ideally, the discovery/fabrication of the 3D scaffolds needs to be high-throughput and uniform to ensure quick and in-depth analysis in order to pinpoint appropriate chemical and mechanical properties of a biomaterial. Herein we present a versatile technique to screen new potential biocompatible acrylate-based 3D scaffolds with the ultimate aim of application in tissue repair. As part of this process, we identified an acrylate-based 3D porous scaffold that promoted cell proliferation followed by accelerated tissue formation, pre-requisites for tissue repair. Scaffolds were fabricated by a facile freeze-casting and an in-situ photo-polymerization route, embracing a high-throughput synthesis, screening and characterization protocol. The current studies demonstrate the dependence of cellular growth and vascularization on the porosity and intrinsic chemical nature of the scaffolds, with tuneable 3D scaffolds generated with large, interconnected pores suitable for cellular growth applied to skeletal reparation. Our studies showed increased cell proliferation, collagen and ALP expression, while chorioallantoic membrane assays indicated biocompatibility and demonstrated the angiogenic nature of the scaffolds. VEGRF2 expression in vivo observed throughout the 3D scaffolds in the absence of growth factor supplementation demonstrates a potential for angiogenesis. This novel platform provides an innovative approach to 3D scanning of synthetic biomaterials for tissue regeneration.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Alicerces Teciduais/química , Engenharia Tecidual/métodos , Materiais Biocompatíveis/farmacologia , Colágeno , Osso e Ossos
10.
J Endovasc Ther ; 19(1): 100-14, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22313210

RESUMO

PURPOSE: To investigate the use of regional variations in the mechanical properties of abdominal aortic aneurysms (AAA) in finite element (FE) modeling of AAA rupture risk, which has heretofore assumed homogeneous mechanical tissue properties. METHODS: Electrocardiogram-gated computed tomography scans from 3 male patients with known infrarenal AAA were used to characterize the behavior of the aneurysm in 4 different segments (posterior, anterior, and left and right lateral) at maximum diameter and above the infrarenal aorta. The elasticity of the aneurysm (circumferential cyclic strain, compliance, and the Hudetz incremental modulus) was calculated for each segment and the aneurysm as a whole. The FE analysis inclusive of prestress (pre-existing tensile stress) produced a detailed stress pattern on each of the aneurysm models under pressure loading. The 4 largest areas of stress in each region were considered in conjunction with the local regional properties of the segment to define a specific regional prestress rupture index (RPRI). RESULTS: In terms of elasticity, there were average reductions of 68% in circumferential cyclic strain and 63% in compliance, with a >5-fold increase in incremental modulus, between the healthy and the aneurysmal aorta for each patient. There were also regional variations in all elastic properties in each individual patient. The average difference in total stress inclusive of prestress was 59%, 67%, and 15%, respectively, for the 3 patients. Comparing the strain from FE models with the CT scans revealed an average difference in strain of 1.55% for the segmented models and 3.61% for the homogeneous models, which suggests that the segmented models more accurately reflect in vivo behavior. RPRI values were calculated for each segment for all patients. CONCLUSION: A greater understanding of the local material properties and their use in FE models is essential for greater accuracy in rupture prediction. Quantifying the regional behavior will yield insight into the changes in patient-specific aneurysms and increase understanding about the progression of aneurysmal disease.


Assuntos
Aorta Abdominal , Aneurisma da Aorta Abdominal/complicações , Ruptura Aórtica/etiologia , Simulação por Computador , Análise de Elementos Finitos , Modelos Cardiovasculares , Idoso , Idoso de 80 Anos ou mais , Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/patologia , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Ruptura Aórtica/diagnóstico por imagem , Ruptura Aórtica/patologia , Ruptura Aórtica/fisiopatologia , Aortografia/métodos , Fenômenos Biomecânicos , Técnicas de Imagem de Sincronização Cardíaca , Progressão da Doença , Elasticidade , Eletrocardiografia , Hemodinâmica , Humanos , Masculino , Medição de Risco , Fatores de Risco , Estresse Mecânico , Tomografia Computadorizada por Raios X
11.
Tissue Eng Regen Med ; 19(1): 73-82, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34714533

RESUMO

BACKGROUND: Today's treatment options for renal diseases fall behind the need, as the number of patients has increased considerably over the last few decades. Tissue engineering (TE) is one avenue which may provide a new approach for renal disease treatment. This involves creating a niche where seeded cells can function in an intended way. One approach to TE is combining natural extracellular matrix proteins with synthetic polymers, which has been shown to have many positives, yet a little is understood in kidney. Herein, we investigate the incorporation of laminin into polycaprolactone electrospun scaffolds. METHOD: The scaffolds were enriched with laminin via either direct blending with polymer solution or in a form of emulsion with a surfactant. Renal epithelial cells (RC-124) were cultured on scaffolds up to 21 days. RESULTS: Mechanical characterization demonstrated that the addition of the protein changed Young's modulus of polymeric fibres. Cell viability and DNA quantification tests revealed the capability of the scaffolds to maintain cell survival up to 3 weeks in culture. Gene expression analysis indicated healthy cells via three key markers. CONCLUSION: Our results show the importance of hybrid scaffolds for kidney tissue engineering.


Assuntos
Laminina , Engenharia Tecidual , Humanos , Rim , Poliésteres , Engenharia Tecidual/métodos , Alicerces Teciduais
12.
Front Endocrinol (Lausanne) ; 13: 997288, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36277721

RESUMO

Primary hypothyroidism severely impacts the quality of life of patients through a decrease in the production of the thyroid hormones T3 and T4, leading to symptoms affecting cardiovascular, neurological, cognitive, and metabolic function. The incidence rate of primary hypothyroidism is expected to increase in the near future, partially due to increasing survival of patients that have undergone radiotherapy for head and neck cancer, which induces this disease in over half of those treated. The current standard of care encompasses thyroid hormone replacement therapy, traditionally in the form of synthetic T4. However, there is mounting evidence that this is unable to restore thyroid hormone signaling in all tissues due to often persistent symptoms. Additional complications are also present in the form of dosage difficulties, extensive drug interactions and poor patience compliance. The alternative therapeutic approach employed in the past is combination therapy, which consists of administration of both T3 and T4, either synthetic or in the form of desiccated thyroid extract. Here, issues are present regarding the lack of regulation concerning formulation and lack of data regarding safety and efficacy of these treatment methods. Tissue engineering and regenerative medicine have been applied in conjunction with each other to restore function of various tissues. Recently, these techniques have been adapted for thyroid tissue, primarily through the fabrication of regenerative scaffolds. Those currently under investigation are composed of either biopolymers or native decellularized extracellular matrix (dECM) in conjunction with either primary thyrocytes or stem cells which have undergone directed thyroid differentiation. Multiple of these scaffolds have successfully restored an athyroid phenotype in vivo. However, further work is needed until clinical translation can be achieved. This is proposed in the form of exploration and combination of materials used to fabricate these scaffolds, the addition of peptides which can aid restoration of tissue homeostasis and additional in vivo experimentation providing data on safety and efficacy of these implants.


Assuntos
Hipotireoidismo , Tireoide (USP) , Humanos , Tiroxina/uso terapêutico , Hipotireoidismo/tratamento farmacológico , Hipotireoidismo/diagnóstico , Tireoide (USP)/uso terapêutico , Qualidade de Vida , Terapia de Reposição Hormonal/métodos , Hormônios Tireóideos/uso terapêutico
13.
J Biomed Mater Res B Appl Biomater ; 110(12): 2612-2623, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35734943

RESUMO

Liver disease is expanding across the globe; however, health-care systems still lack approved pharmaceutical treatment strategies to mitigate potential liver failures. Organ transplantation is the only treatment for liver failure and with increasing cases of liver disease, transplant programs increasingly cannot provide timely transplant availability for all patients. The development of pharmaceutical mitigation strategies is clearly necessary and methods to improve drug development processes are considered vital for this purpose. Herein, we present a methodology for incorporating whole organ decellularised rat liver ECM (rLECM) into polycaprolactone (PCL) electrospun scaffolds with the aim of producing biologically relevant liver tissue models. rLECM PCL scaffolds have been produced with 5 w/w% and 10 w/w% rLECM:PCL and were analyzed by SEM imaging, tensile mechanical analyses and FTIR spectroscopy. The hepatocellular carcinoma cell line, HepG2, was cultured upon the scaffolds for 14 days and were analyzed through cell viability assay, DNA quantification, albumin quantification, immunohistochemistry, and RT-qPCR gene expression analysis. Results showed significant increases in proliferative activity of HepG2 on rLECM containing scaffolds alongside maintained key gene expression. This study confirms that rLECM can be utilized to modulate the bioactivity of electrospun PCL scaffolds and has the potential to produce electrospun scaffolds suitable for enhanced hepatocyte cultures and in-vitro liver tissue models.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Ratos , Albuminas , Hepatócitos , Fígado , Poliésteres/química , Engenharia Tecidual/métodos , Alicerces Teciduais/química
14.
Cell Stem Cell ; 29(3): 355-371.e10, 2022 03 03.
Artigo em Inglês | MEDLINE | ID: mdl-35245467

RESUMO

Biliary diseases can cause inflammation, fibrosis, bile duct destruction, and eventually liver failure. There are no curative treatments for biliary disease except for liver transplantation. New therapies are urgently required. We have therefore purified human biliary epithelial cells (hBECs) from human livers that were not used for liver transplantation. hBECs were tested as a cell therapy in a mouse model of biliary disease in which the conditional deletion of Mdm2 in cholangiocytes causes senescence, biliary strictures, and fibrosis. hBECs are expandable and phenotypically stable and help restore biliary structure and function, highlighting their regenerative capacity and a potential alternative to liver transplantation for biliary disease.


Assuntos
Transplante de Fígado , Animais , Ductos Biliares/patologia , Células Epiteliais/patologia , Fibrose , Humanos , Doadores Vivos , Camundongos
15.
J Mater Chem B ; 9(38): 8081-8093, 2021 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-34491259

RESUMO

Severe liver disease is one of the most common causes of death globally. Currently, whole organ transplantation is the only therapeutic method for end-stage liver disease treatment, however, the need for donor organs far outweighs demand. Recently liver tissue engineering is starting to show promise for alleviating part of this problem. Electrospinning is a well-known method to fabricate a nanofibre scaffold which mimics the natural extracellular matrix that can support cell growth. This study aims to investigate liver cell responses to topographical features on electrospun fibres. Scaffolds with large surface depression (2 µm) (LSD), small surface depression (0.37 µm) (SSD), and no surface depression (NSD) were fabricated by using a solvent-nonsolvent system. A liver cell line (HepG2) was seeded onto the scaffolds for up to 14 days. The SSD group exhibited higher levels of cell viability and DNA content compared to the other groups. Additionally, the scaffolds promoted gene expression of albumin, with all cases having similar levels, while the cell growth rate was altered. Furthermore, the scaffold with depressions showed 0.8 MPa higher ultimate tensile strength compared to the other groups. These results suggest that small depressions might be preferred by HepG2 cells over smooth and large depression fibres and highlight the potential for tailoring liver cell responses.


Assuntos
Poliésteres/química , Engenharia Tecidual , Alicerces Teciduais/química , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia , Sobrevivência Celular/efeitos dos fármacos , Cadeia alfa 1 do Colágeno Tipo I/genética , Cadeia alfa 1 do Colágeno Tipo I/metabolismo , Regulação da Expressão Gênica/efeitos dos fármacos , Células Hep G2 , Humanos , Fígado/citologia , Fígado/metabolismo , Porosidade , Albumina Sérica Humana/genética , Albumina Sérica Humana/metabolismo , Propriedades de Superfície , Resistência à Tração
16.
Biofabrication ; 13(3)2021 06 28.
Artigo em Inglês | MEDLINE | ID: mdl-34102613

RESUMO

Recent advancements in the bioinks and three-dimensional (3D) bioprinting methods used to fabricate vascular constructs are summarized herein. Critical biomechanical properties required to fabricate an ideal vascular graft are highlighted, as well as various testing methods have been outlined to evaluate the bio-fabricated grafts as per the Food and Drug Administration (FDA) and International Organization for Standardization (ISO) guidelines. Occlusive artery disease and cardiovascular disease are the major causes of death globally. These diseases are caused by the blockage in the arteries, which results in a decreased blood flow to the tissues of major organs in the body, such as the heart. Bypass surgery is often performed using a vascular graft to re-route the blood flow. Autologous grafts represent a gold standard for such bypass surgeries; however, these grafts may be unavailable due to the previous harvesting or possess a poor quality. Synthetic grafts serve well for medium to large-sized vessels, but they fail when used to replace small-diameter vessels, generally smaller than 6 mm. Various tissue engineering approaches have been used to address the urgent need for vascular graft that can withstand hemodynamic blood pressure and has the ability to grow and remodel. Among these approaches, 3D bioprinting offers an attractive solution to construct patient-specific vessel grafts with layered biomimetic structures.


Assuntos
Bioimpressão , Prótese Vascular , Humanos , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais , Estados Unidos
17.
Sci Rep ; 11(1): 3059, 2021 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-33542251

RESUMO

Liver disease cases are rapidly expanding across the globe and the only effective cure for end-stage disease is a transplant. Transplant procedures are costly and current supply of donor livers does not satisfy demand. Potential drug treatments and regenerative therapies that are being developed to tackle these pressing issues require effective in-vitro culture platforms. Electrospun scaffolds provide bio-mimetic structures upon which cells are cultured to regulate function in-vitro. This study aims to shed light on the effects of electrospun PCL morphology on the culture of an immortalised hepatic cell line and mouse primary hepatocytes. Each cell type was cultured on large 4-5 µm fibres and small 1-2 µm fibres with random, aligned and highly porous cryogenically spun configurations. Cell attachment, proliferation, morphology and functional protein and gene expression was analysed. Results show that fibre morphology has a measurable influence on cellular morphology and function, with the alteration of key functional markers such as CYP1A2 expression.


Assuntos
Citocromo P-450 CYP1A2/genética , Hepatopatias/terapia , Fígado/metabolismo , Alicerces Teciduais/química , Animais , Biomimética , Proliferação de Células/genética , Regulação da Expressão Gênica , Células Hep G2 , Hepatócitos/metabolismo , Hepatócitos/patologia , Humanos , Fígado/crescimento & desenvolvimento , Fígado/patologia , Hepatopatias/genética , Hepatopatias/patologia , Camundongos , Engenharia Tecidual/métodos
18.
Med Eng Phys ; 94: 52-60, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34303502

RESUMO

There is a high demand for small diameter vascular grafts having mechanical and biological properties similar to that of living tissues. Tissue-engineered vascular grafts using current methods have often failed due to the mismatch of mechanical properties between the implanted graft and living tissues. To address this limitation, a hybrid bioprinting-electrospinning system is developed for vascular tissue engineering applications. The setup is capable of producing layered structure from electrospun fibres and cell-laden hydrogel. A Creality3D Ender 3D printer has been modified into a hybrid setup having one bioprinting head and two electrospinning heads. Fortus 250mc and Flashforge Creator Pro 3D printers were used to print parts using acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA) polymers. An Arduino mega 2560 and a Ramps 1.4 controller board were selected to control the functions of the hybrid bioprinting setup. The setup was tested successfully to print a tubular construct around a rotating needle.


Assuntos
Bioimpressão , Hidrogéis , Impressão Tridimensional , Engenharia Tecidual , Alicerces Teciduais
19.
Biofabrication ; 13(4)2021 07 27.
Artigo em Inglês | MEDLINE | ID: mdl-34186522

RESUMO

Mimicking the native three-dimensional microenvironment is of crucial importance when biofabricating a new healthcare material. One aspect of the native tissue that is often omitted when designing a suitable scaffold is its anisotropy. Not only is matching native mechanical properties important when designing implantable scaffolds or healthcare materials, but matching physiological structure is also important as many cell populations respond differently to fiber orientation. Therefore, novel aligned electrospun scaffolds with varying fiber angles and spacing of bundles were created and mechanically characterized. Through controlling the angle between the fibers in each layer of the scaffold, a range of different physiological anisotropic mechanical properties were achieved that encompasses values found in native tissues. Extrapolation of this mechanical data allowed for any native tissue's anisotropic Young's modulus to be mimicked by electrospinning fibers at a particular angle. These electrospun scaffolds were then incorporated with cell-laden hydrogels to create hybrid structures that contain the benefits of both scaffolding techniques with the ability to encapsulate cells in the hydrogel. To conclude, this study develops a novel bundled fiber scaffold that was architected to yield anisotropic properties matching native tissues.


Assuntos
Engenharia Tecidual , Alicerces Teciduais , Anisotropia , Materiais Biocompatíveis , Hidrogéis
20.
J Endovasc Ther ; 17(1): 95-107, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20199275

RESUMO

PURPOSE: To develop an improved methodology for investigating the parameters influencing stent-graft migration, with particular focus on the limitations of existing methods. METHODS: A physiological silicone rubber abdominal aortic aneurysm (AAA) model for fixation studies was manufactured based on an idealized AAA geometry: the model had a 24-mm neck, a 50-mm aneurysm, 12-mm-diameter legs, a 60 degrees bifurcation angle, and 2-mm-thick walls. The models were authenticated in neck fixation experiments. The displacement force required to migrate stent-grafts in physiological pulsatile flow was tested dynamically in water at 37 degrees C. A commercially available longitudinally rigid stent-graft (AneuRx) and a homemade device with little longitudinal rigidity were studied in a number of different configurations to investigate the effect of neck fixation length and systolic pressure on displacement force. RESULTS: The AneuRx (6.95+/-0.49 to 8.52+/-0.5 N) performed significantly better than the homemade device (2.57+/-0.11 to 4.62+/-0.25 N) in pulsatile flow. The opposite was true in the neck fixation tests because the longitudinal stiffness of the AneuRx was not accounted for. Increasing pressure or decreasing fixation length compromised the fixation of the homemade device. This relationship was not as clear for the AneuRx because decreasing proximal fixation resulted in an increase in iliac fixation, which could assist fixation in this device. CONCLUSION: Assessing the migration resistance of stent-grafts based solely on proximal fixation discriminates against devices that are longitudinally stiff. Current in vivo models may give inaccurate displacement forces due to the high degree of oversizing in these studies. A novel in vitro approach, accounting for longitudinal rigidity and realistic graft oversizing, was developed to determine the resistance of aortic stent-grafts to migration in the period immediately after device implantation.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Migração de Corpo Estranho/prevenção & controle , Stents , Aorta Abdominal/patologia , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Análise de Falha de Equipamento , Migração de Corpo Estranho/etiologia , Humanos , Teste de Materiais , Modelos Anatômicos , Falha de Prótese , Fluxo Pulsátil , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA