Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Appl Opt ; 62(26): 6916-6923, 2023 Sep 10.
Artigo em Inglês | MEDLINE | ID: mdl-37707030

RESUMO

Vector measurement is a vital measurement item during the satellite assembly, integration, and test (AIT) process. With the increasing popularity of commercial spaceflight, the development cycle of a satellite is shorter, and the number of satellites has been growing rapidly. The traditional on-site vector measurement method is inefficient and significantly affects the development cycle of the satellite. Therefore, it is of utter importance to propose an online high-precision automatic vector measurement system. The most challenging step of the online automatic vector measurement is coarse alignment because a cubic prism must be identified, and the normal direction of its surface must be calculated at a certain precision in the unstructured environment during the coarse alignment step. A reflection-based vision guide method was proposed to identify and calculate the normal direction of the cubic prism. The working principle and advantage of the proposed vision guide system were described in detail. What is more, the calibration and calculation methods of the proposed vision guide system were also presented. Finally, experiments were conducted to verify the effectiveness of the proposed method.

2.
Anal Bioanal Chem ; 372(2): 391-6, 2002 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-11936117

RESUMO

Molecularly imprinted microspheres (MIMs) against trimethoprim (TMP), prepared by aqueous microsuspension polymerization, bound strongly to TMP, by electrostatic and other non-covalent interactions. The effects of pH, kind and ionic strength (I) of buffer on capacity factors (k') have been discussed in detail. The capacity factors for TMP increased with increasing pH of both acetate and phosphate buffers. The effects of ionic strength on capacity factors were very substantial and the linear relationship between logk' and logI was described by the equation logk'=0.3162-0.4420logI with R=-0.9995. The results showed that pH 3.5 acetate buffer (0.05 mol L(-1)) containing 0.1 mol L(-1) sodium chloride and a 1:9 ratio of buffer to methanol were the optimum conditions for separation and determination of TMP. The calibration plot of peak area against concentration was linear with R=0.9979.


Assuntos
Técnicas Biossensoriais/métodos , Polímeros/síntese química , Trimetoprima/análise , Soluções Tampão , Calibragem , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Microesferas , Concentração Osmolar , Polímeros/química , Propriedades de Superfície , Trimetoprima/isolamento & purificação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA