Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Transp Porous Media ; 136(1): 245-270, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33250547

RESUMO

We present pore-scale simulations of two-phase flows in a reconstructed fibrous porous layer. The three-dimensional microstructure of the material, a fuel cell gas diffusion layer, is acquired via X-ray computed tomography and used as input for lattice Boltzmann simulations. We perform a quantitative analysis of the multiphase pore-scale dynamics, and we identify the dominant fluid structures governing mass transport. The results show the existence of three different regimes of transport: a fast inertial dynamics at short times, characterised by a compact uniform front, a viscous-capillary regime at intermediate times, where liquid is transported along a gradually increasing number of preferential flow paths of the size of one-two pores, and a third regime at longer times, where liquid, after having reached the outlet, is exclusively flowing along such flow paths and the two-phase fluid structures are stabilised. We observe that the fibrous layer presents significant variations in its microscopic morphology, which have an important effect on the pore invasion dynamics, and counteract the stabilising viscous force. Liquid transport is indeed affected by the presence of microstructure-induced capillary pressures acting adversely to the flow, leading to capillary fingering transport mechanism and unstable front displacement, even in the absence of hydrophobic treatments of the porous material. We propose a macroscopic model based on an effective contact angle that mimics the effects of the such a dynamic capillary pressure. Finally, we underline the significance of the results for the optimal design of face masks in an effort to mitigate the current COVID-19 pandemic.

2.
Artif Organs ; 34(4): 319-23, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20420614

RESUMO

Ceramic-on-ceramic and metal-on-metal bearing surfaces are often employed for total hip replacement because of their resistance to wear. However, they have some limits: brittleness is a major concern for ceramic, and ion release is a drawback for metal. To reduce the effect of these limitations, a hybrid coupling of ceramic-on-metal has been proposed. The theoretical advantage of this new coupling might lead orthopedic surgeons to use it indiscriminately. We asked whether the wear rate of this innovative solution was comparable with that of ceramic-on-ceramic, which is considered to be the gold standard for wear resistance. In a hip simulator study, we tested the wear pattern of a hybrid ceramic-on-metal coupling supplied by the same distributor; in particular, three different configurations were tested for 5 million cycles: 36-mm ceramic-on-ceramic, 32-mm and 36-mm ceramic-on-metal. These combinations were gravimetrically and geometrically evaluated. After 5 million cycles, the volumetric loss for the metal acetabular cups (Phi 36-mm) was 20-fold greater than that of the ceramic cups of the same size (Phi 36-mm); a volumetric loss of 4.35 mm(3) and 0.26 mm(3) was observed, respectively, for ceramic-on-metal and ceramic-on-ceramic combinations. Significant statistical differences were observed between all 36-mm different combinations (P < 0.0001). The increased diameter of the 36-mm ceramic-on-metal configuration resulted in a lower volumetric loss compared with that of the 32-mm ceramic-on-metal configuration. Our findings showed an increase in wear for the proposed hybrid specimens with respect to that of the ceramic-on-ceramic ones. This confirms that even in the case of ceramic-on-metal bearings, mixing and matching could not prove effective wear behavior, not even comparable with that of the ceramic-on-ceramic gold standard.


Assuntos
Artroplastia de Quadril/instrumentação , Cerâmica , Teste de Materiais/instrumentação , Metais , Materiais Biocompatíveis , Prótese de Quadril , Desenho de Prótese , Propriedades de Superfície
3.
J Clin Med ; 9(5)2020 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-32365687

RESUMO

Silica-based ceramics have been proposed for coating purposes to enhance dental and orthopedic titanium (Ti) implant bioactivity. The aim of this study was to investigate the influence of sphene-based bioceramic (CaO.TiO2.SiO2) coatings on implant osseointegration in vivo. Sphene coatings were obtained from preceramic polymers and nano-sized active precursors and deposited by an automatic airbrush. Twenty customized Ti implants, ten sphene-coated and ten uncoated rough implants were implanted into the proximal femurs of ten Sprague-Dawley rats. Overall, cortical and cancellous bone-to-implant contact (BIC) were determined using micro-computed tomography (micro-CT) at 14 and 28 days. Moreover, peri-implant bone healing was histologically and histomorphometrically evaluated. The white blood cell count in the synovial fluid of the knee joints, if present, was also assessed. No difference in the BIC values was observed between the sphene-coated and uncoated implants, overall and in the two bone compartments (p > 0.05). Delamination of the coating occurred in three cases. Consistently with micro-CT data, the histological evaluation revealed no differences between the two groups. In addition, no synovial fluid could be collected on the test side, thus confirming sphene biocompatibility. In conclusion, sphene coating was found to be a suitable material for biomedical applications. Further studies are needed to improve coating adhesion to the implants.

4.
Math Biosci Eng ; 17(4): 3894-3908, 2020 05 25.
Artigo em Inglês | MEDLINE | ID: mdl-32987559

RESUMO

The surgical treatment of urinary incontinence is often performed by adopting an Artificial Urinary Sphincter (AUS). AUS cuff represents a fundamental component of the device, providing the mechanical action addressed to urethral occlusion, which can be investigated by computational approach. In this work, AUS cuff is studied with reference to both materials and structure, to develop a finite element model. Materials behavior is investigated using physicochemical and mechanical characterization, leading to the formulation of a constitutive model. Materials analysis shows that AUS cuff is composed by a silicone blister joined with a PET fiber-reinforced layer. A nonlinear mechanical behavior is found, with a higher stiffness in the outer layer due to fiber-reinforcement. The cuff conformation is acquired by Computer Tomography (CT) both in deflated and inflated conditions, for an accurate definition of the geometrical characteristics. Based on these data, the numerical model of AUS cuff is defined. CT images of the inflated cuff are compared with results of numerical analysis of the inflation process, for model validation. A relative error below 2.5% was found. This study is the first step for the comprehension of AUS mechanical behavior and allows the development of computational tools for the analysis of lumen occlusion process. The proposed approach could be adapted to further fluid-filled cuffs of artificial sphincters.


Assuntos
Incontinência Urinária , Esfíncter Urinário Artificial , Humanos , Masculino , Uretra
5.
Materials (Basel) ; 13(24)2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33322289

RESUMO

X-ray computed tomography is one of the most promising measurement techniques for the dimensional evaluation of industrial components. However, the inherent complexity of this technology also involves important challenges. One of them is to develop surface determination algorithms capable of providing measurement results with better accuracy in any situation-for example, for single and multi-material parts, inner and outer geometries, with and without image artefacts, etc.-and reducing user influence. The surface determination is particularly complex in the case of multi-material parts, especially when they are separated by small air gaps. In previous works, two gradient-based algorithms were presented, that showed less measurement variability throughout the whole part, and reduced the computational cost and operator influence compared to threshold-based algorithms. This work focuses on the evaluation of the performance of these algorithms when used in a scenario so complex that parts of it are made of one or more materials (metal-metal and polymer-metal) with gaps inside. For this purpose, a set of multi-material reference standards is used. The presented gradient-based algorithms show measurement errors comparable to commercial threshold-based algorithms, but with the capability of obtaining accurate measurements in smaller gaps, apart from reducing the user influence on the measurement process.

6.
Med Eng Phys ; 29(9): 954-66, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17126062

RESUMO

The contribution of this paper is twofold: (1) it presents an automatic 3D modeling technique and (2) it advances a procedure for its metrological evaluation in the context of a medical application, the 3D modeling of dental plaster casts. The motivation for this work is the creation of a "virtual gypsotheque" where cumbersome dental plaster casts can be replaced by numerical 3D models, thereby alleviating storage and access problems and allowing dentists and orthodontists the use of novel and unprecedented software tools for their medical evaluations. Modeling free-form surfaces of anatomical interest is an intriguing mixture of open issues concerning 3D modeling, geometrical metrology, and medicine. Of general interest is both the fact that a widespread use of 3D modeling in non-engineering applications requires automatic procedures of the kind presented in this work and the adopted validation paradigm for free-form surfaces, rather useful for practical purposes. In this latter respect, the metrological analysis we advance is the first seminal attempt in the field of 3D modeling and can be readily extended to contexts other than the medical one discussed in this paper.


Assuntos
Desenho Assistido por Computador , Modelos Dentários , Interface Usuário-Computador , Simulação por Computador , Humanos , Aumento da Imagem , Imageamento Tridimensional , Modelos Dentários/normas , Aparelhos Ortopédicos , Imagens de Fantasmas
7.
PLoS One ; 12(1): e0170263, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28107468

RESUMO

More than 60.000 hip arthroplasty are performed every year in Italy. Although Ultra-High-Molecular-Weight-Polyethylene remains the most used material as acetabular cup, wear of this material induces over time in vivo a foreign-body response and consequently osteolysis, pain, and the need of implant revision. Furthermore, oxidative wear of the polyethylene provoke several and severe failures. To solve these problems, highly cross-linked polyethylene and Vitamin-E-stabilized polyethylene were introduced in the last years. In in vitro experiments, various efforts have been made to compare the wear behavior of standard PE and vitamin-E infused liners. In this study we compared the in vitro wear behavior of two different configurations of cross-linked polyethylene (with and without the add of Vitamin E) vs. the standard polyethylene acetabular cups. The aim of the present study was to validate a micro X-ray computed tomography technique to assess the wear of different commercially available, polyethylene's acetabular cups after wear simulation; in particular, the gravimetric method was used to provide reference wear values. The agreement between the two methods is documented in this paper.


Assuntos
Reagentes de Ligações Cruzadas/química , Articulação do Quadril/diagnóstico por imagem , Polietileno/química , Polietilenos/química , Microtomografia por Raio-X/métodos , Humanos
8.
Materials (Basel) ; 10(3)2017 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-28772616

RESUMO

Wear is currently quantified as mass loss of the bearing materials measured using gravimetric methods. However, this method does not provide other information, such as volumetric loss or surface deviation. In this work, we validated a technique to quantify polyethylene wear in three different batches of ultrahigh-molecular-polyethylene acetabular cups used for hip implants using nondestructive microcomputed tomography. Three different configurations of polyethylene acetabular cups, previously tested under the ISO 14242 parameters, were tested on a hip simulator for an additional 2 million cycles using a modified ISO 14242 load waveform. In this context, a new approach was proposed in order to simulate, on a hip joint simulator, high-demand activities. In addition, the effects of these activities were analyzed in terms of wear and deformations of those polyethylenes by means of gravimetric method and micro X-ray computed tomography. In particular, while the gravimetric method was used for weight loss assessment, microcomputed tomography allowed for acquisition of additional quantitative information about the evolution of local wear and deformation through three-dimensional surface deviation maps for the entire cups' surface. Experimental results showed that the wear and deformation behavior of these materials change according to different mechanical simulations.

9.
J Biomed Mater Res B Appl Biomater ; 104(7): 1374-85, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26212106

RESUMO

This study was aimed at determining the surface degradation occurred on retrieved ceramic and metallic heads, as well as the influence of the head surface quality on the wear of the polyethylene counterface. To this purpose, 14 ceramic and 14 metallic femoral heads retrieved at revision surgery were examined. Scanning electron microscopic analysis provided visual evidence that some metallic heads presented crescent wear more often than the ceramic ones; the former showed a higher volumetric loss (as determined by Coordinate Measuring Machine) than the latter, but less negative Rsk values. This apparent lack of correlation between volumetric loss (i.e., wear factor) and roughness data may be explained by considering that they are two temporally variant parameters. No significant differences were observed between the Ra values of the two sets of femoral heads. The cups articulating against metal heads were characterized by higher mean wear volumes than those articulating against alumina although this difference was not statistically significant; metal heads displayed significantly higher mean wear volumes than alumina heads. The micro-Raman analysis of the cup articulated against the most worn alumina femoral head showed an orthorhombic into monoclinic phase transformation that was not observed in the cups coupled to metal heads. The obtained results showed that the surface finishing of the femoral head (in terms of Rsk values) determined the morphological changes experienced by the ultra-high-molecular-weight polyethylene crystalline phase at the molecular level. © 2015 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 104B: 1374-1385, 2016.


Assuntos
Prótese de Quadril , Polietilenos/química , Adulto , Idoso , Feminino , Seguimentos , Humanos , Masculino , Microscopia Eletroquímica de Varredura , Pessoa de Meia-Idade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA