Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Anal Bioanal Chem ; 416(4): 925-944, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38214704

RESUMO

Lipids are a diverse class of molecules involved in many biological functions including cell signaling or cell membrane assembly. Owing to this relevance, LC-MS/MS-based lipidomics emerged as a major field in modern analytical chemistry. Here, we thoroughly characterized the influence of MS and LC settings - of a Q Exactive HF operated in Full MS/data-dependent MS2 TOP N acquisition mode - in order to optimize the semi-quantification of polar lipids. Optimization of MS-source settings improved the signal intensity by factor 3 compared to default settings. Polar lipids were separated on an ACQUITY Premier CSH C18 reversed-phase column (100 × 2.1 mm, 1.7 µm, 130 Å) during an elution window of 28 min, leading to a sufficient number of both data points across the chromatographic peaks, as well as MS2 spectra. Analysis was carried out in positive and negative ionization mode enabling the detection of a broader spectrum of lipids and to support the structural characterization of lipids. Optimal sample preparation of biological samples was achieved by liquid-liquid extraction using MeOH/MTBE resulting in an excellent extraction recovery > 85% with an intra-day and inter-day variability < 15%. The optimized method was applied on the investigation of changes in the phospholipid pattern in plasma from human subjects supplemented with n3-PUFA (20:5 and 22:6). The strongest increase was observed for lipids bearing 20:5, while 22:4 bearing lipids were lowered. Specifically, LPC 20:5_0:0 and PC 16:0_20:5 were found to be strongest elevated, while PE 18:0_22:4 and PC 18:2_18:2 were decreased by n3-PUFA supplementation. These results were confirmed by targeted LC-MS/MS using commercially available phospholipids as standards.


Assuntos
Lipidômica , Fosfolipídeos , Humanos , Fosfolipídeos/análise , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massa com Cromatografia Líquida , Cromatografia Líquida de Alta Pressão
2.
Anal Chim Acta ; 1326: 343139, 2024 Oct 16.
Artigo em Inglês | MEDLINE | ID: mdl-39260917

RESUMO

BACKGROUND: Several oxylipins including hydroxy- and epoxy-polyunsaturated fatty acids act as lipid mediators. In biological samples they can be present as non-esterified form, but the major part occurs esterified in phospholipids (PL) or other lipids. Esterified oxylipins are quantified indirectly after alkaline hydrolysis as non-esterified oxylipins. However, in this indirect analysis the information in which lipid class oxylipins are bound is lost. In this work, an untargeted liquid chromatography high-resolution mass spectrometry (LC-HRMS) method for the direct analysis of PL bearing oxylipins was developed. RESULTS: Optimized reversed-phase LC separation achieved a sufficient separation of isobaric and isomeric PL from different lipid classes bearing oxylipin positional isomers. Individual PL species bearing oxylipins were identified based on retention time, precursor ion and characteristic product ions. The bound oxylipin could be characterized based on product ions resulting from the α-cleavage occurring at the hydroxy/epoxy group. PL sn-1/sn-2 isomers were identified based on the neutral loss of the fatty acyl in the sn-2 position. A total of 422 individual oxPL species from 7 different lipid classes i.e., PI, PS, PC, PE, PC-P, PC-O, and PE-P were detected in human serum and cells. This method enabled to determine in which PL class supplemented oxylipins are incorporated in HEK293 cells: 20:4;15OH, 20:4;14Ep, and 20:5;14Ep were mostly bound to PI. 20:4;8Ep and 20:5;8Ep were esterified to PC and PE while other oxylipins were mainly found in PC. SIGNIFICANCE: The developed LC-HRMS method enables the comprehensive detection as well as the semi-quantification of isobaric and isomeric PL species bearing oxylipins. With this method, we show that the position of the oxidation has a great impact and directs the incorporation of oxylipins into the different PL classes in human cells.


Assuntos
Espectrometria de Massas , Oxilipinas , Fosfolipídeos , Oxilipinas/análise , Oxilipinas/química , Humanos , Fosfolipídeos/análise , Fosfolipídeos/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Isomerismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA