Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
BJU Int ; 109(12): 1770-5, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21992499

RESUMO

Study Type - Diagnostic (validating cohort) Level of Evidence 1b What's known on the subject? and What does the study add? Nadir Ultrasensitive PSA levels has some value for predicting BCR following RD. AccuPSA assays lower limit of PSA quantification of <0.01 pg/ml greatly enhances sensitivity and specificity of nadir PSA to predict BCR following RP. Our pilot study shows an AccuPSA of 3 pg/ml has a sensitory and specificity of 100% and 75% respectively for predicting 5 year BCR following RP. OBJECTIVES • To conduct a proof of concept study to evaluate a novel digital single molecule immunoassay (AccuPSA(TM) ) that detects prostate-specific antigen (PSA) a thousandfold more sensitively than current PSA detection methods. • To determine the ability of the AccuPSA(TM) assay to predict 5-year biochemical recurrence (BCR)-free survival after radical prostatectomy (RP). PATIENTS AND METHODS • A total of 31 frozen serum specimens were obtained from specimen logs maintained at New York University Langone Medical Center and the Johns Hopkins University School of Medicine on men who had undergone RP. Those men without evidence of BCR had a minimum of 5 years' PSA follow-up. • In all cases, preoperative and pathological information were available, as was a serum specimen 3-6 months after RP, with a PSA level of <0.1 ng/mL measured by conventional PSA methods at the time of serum collection. • Specimens were tested using the AccuPSA(TM) method. • A Cox proportional hazard model and Kaplan-Meier analysis were used to determine whether AccuPSA(TM) predicted the risk of BCR. RESULTS • Overall, 11/31 (35.5%) men developed BCR. • Mean AccuPSA(TM) nadir levels were significantly different (P < 0.001) between the non-BCR group (2.27 pg/mL) and the BCR group (46.99 pg/mL). • Using a multivariate Cox proportional hazard model, AccuPSA(TM) nadir level was a significant predictor of BCR-free survival (P < 0.01). • Kaplan-Meier analysis of up to 5 years follow-up showed that 100% of men with AccuPSA(TM) nadir values <3 pg/mL did not develop BCR, whereas 62.5% of men with values >3 pg/mL developed BCR (P= 0.00024). • The sensitivity, specificity, positive predictive value and negative predictive value of the AccuPSA(TM) method was 100%, 75%, 69% and 100%, respectively. CONCLUSIONS • AccuPSA(TM) assay predicts 5-year BCR- free survival after RP. • Identifying a reliable predictor of BCR soon after RP has important implications for frequency of PSA testing, selection of candidates for adjuvant therapy, and reassuring a large subset of men that they are not at risk of recurrence. • Larger studies are needed to validate these findings.


Assuntos
Recidiva Local de Neoplasia/diagnóstico , Antígeno Prostático Específico/metabolismo , Prostatectomia/mortalidade , Neoplasias da Próstata/diagnóstico , Intervalo Livre de Doença , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/mortalidade , Projetos Piloto , Prostatectomia/métodos , Neoplasias da Próstata/mortalidade , Sensibilidade e Especificidade
2.
Clin Chem ; 57(12): 1712-21, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21998342

RESUMO

BACKGROUND: Measurement of prostate-specific antigen (PSA) in prostate cancer patients following radical prostatectomy (RP) has been hindered by the limit of quantification of available assays. Because radical prostatectomy removes the tissue responsible for PSA production, postsurgical PSA is typically undetectable with current assay methods. Evidence suggests, however, that more sensitive determination of PSA status following RP could improve assessment of patient prognosis and response to treatment and better target secondary therapy for those who may benefit most. We developed an investigational digital immunoassay with a limit of quantification 2 logs lower than current ultrasensitive third-generation PSA assays. METHODS: We developed reagents for a bead-based ELISA for use with high-density arrays of femtoliter-volume wells. Anti-PSA capture beads with immunocomplexes and associated enzyme labels were singulated within the wells of the arrays and interrogated for the presence of enzymatic product. We characterized analytical performance, compared its accuracy with a commercially available test, and analyzed longitudinal serum samples from a pilot study of 33 RP patients. RESULTS: The assay exhibited a functional sensitivity (20% interassay CV) <0.05 pg/mL, total imprecision <10% from 1 to 50 pg/mL, and excellent agreement with the comparator method. All RP samples were well within the assay measurement capability. PSA concentrations following surgery were found to be predictive of prostate cancer recurrence risk over 5 years. CONCLUSIONS: The robust 2-log improvement in limit of quantification relative to current ultrasensitive assays and the validated analytical performance of the assay allow for accurate assessment of PSA status after RP.


Assuntos
Ensaio de Imunoadsorção Enzimática/métodos , Antígeno Prostático Específico/sangue , Processamento Eletrônico de Dados , Humanos , Masculino , Microquímica/métodos , Pessoa de Meia-Idade , Projetos Piloto , Prostatectomia , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/cirurgia , Análise Serial de Proteínas/métodos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA