Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Cornea ; 42(12): 1513-1519, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728263

RESUMO

PURPOSE: The aim of this study was to evaluate the safety and efficacy of contact lenses (CLs) in eyes after simple limbal epithelial transplantation (SLET) for limbal stem cell deficiency (LSCD). METHODS: This retrospective study included 61 eyes with partial or total LSCD which underwent SLET and were fitted with corneal or scleral rigid gas-permeable CLs. The primary outcome measure was best-corrected visual acuity (BCVA) with CLs. RESULTS: The median age at presentation was 22 years. The most common cause of LSCD was chemical injury [47/61 eyes (77%)]. Twenty-seven eyes (44%) were fitted with corneal rigid gas-permeable lenses, while 34 eyes (56%) were prescribed scleral lenses. The median duration of interval between SLET and CL trial was 10 months (interquartile range: 4-17). The median preoperative BCVA was logarithm of minimal angle of resolution (logMAR) 1.8. This improved to logMAR 1 ( P < 0.001) after SLET and to logMAR 0.6 ( P < 0.001) with CLs. Eyes with chemical injury (logMAR 1 vs. 0.6, P = 0.0001), grade 1 (logMAR 0.8 vs. 0.4, P < 0.0001), and grade 2 (logMAR 0.9 vs. 0.6, P = 0.004) corneal scarring had better improvement in BCVA with CLs. No complications were noted until the last follow-up visit. CONCLUSIONS: CLs, both corneal and scleral lenses, provide significant visual improvement in eyes after SLET with residual corneal scarring. These can be safely prescribed in such eyes without any adverse effects. This option can be considered before offering keratoplasty in these eyes.


Assuntos
Queimaduras Químicas , Lentes de Contato , Doenças da Córnea , Lesões da Córnea , Deficiência Límbica de Células-Tronco , Limbo da Córnea , Humanos , Adulto Jovem , Adulto , Estudos Retrospectivos , Cicatriz , Transplante Autólogo , Limbo da Córnea/cirurgia , Queimaduras Químicas/cirurgia , Transplante de Células-Tronco , Doenças da Córnea/cirurgia
2.
Cont Lens Anterior Eye ; 43(3): 256-260, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31813766

RESUMO

PURPOSE: To report the role of Bulls eye drop applicator device in self-instillation of eye drops and in prevention of wastage of medicine. METHODS: A small pocket sized device "Bulls eye drop applicator" was developed, which is a simple, handy, mirror-based attachment which can be attached to any eye drop bottle to help in accurate self-instillation of the drops in the eye. The prototype of this device was tried in ten volunteer subjects (Group 1) and 15 patients (Group 2); they were asked to use lubricating eye drops (5 ml bottle) in one eye without the device (N) and in the other eye with the device (M). The numbers of attempts for the application of eye drops were noted and the residual eye drops in the returned bottles were measured for quantitative assessment. RESULTS: Ten volunteers and 11/15 patients completed the study. At the completion of the study, there were a total of 232 applications of eye drops in the Group 1 N (without device) and 1 M (with device). To achieve these 232 applications, there were 330 attempts without the device and 266 attempts of instillation were needed with the device (P < 0.0001). In Group 2, there were a total of 544 applications of eye drops; to achieve this, there were 879 attempts in Group 2 N and 685 attempts of instillation in Group 2 M (p < 0.0001). The cumulative quantity of residual drops in the returned bottles collected from Group 2 N was 5.1 ml and it was 19.7 ml in Group 2 M (p = 0.001). CONCLUSIONS: The number of attempts of instillation reduced significantly with the use of the eye drop applicator device. The use of eye drops applicator device reduced the wastage of drops from 42.2% to 14.6% in Group 1 N Vs Group 1 M and saving of about 35.7 % in Group 2 M compared to Group 2 N.


Assuntos
Anti-Hipertensivos/administração & dosagem , Glaucoma/tratamento farmacológico , Acuidade Visual , Administração Tópica , Desenho de Equipamento , Feminino , Humanos , Lubrificantes Oftálmicos/farmacologia , Masculino , Soluções Oftálmicas/farmacologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA