Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Pediatr Cardiol ; 39(4): 837-843, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29497771

RESUMO

Hypoplastic left heart syndrome (HLHS) palliation may result in altered cerebral blood flow with subsequent neurodevelopmental implications. The purpose of the study was to assess blood flow in the middle cerebral artery (MCA) and investigate the relationship with early neurodevelopmental outcomes in infants with HLHS after hybrid stage I. Transcranial Doppler (TCD) was performed to obtain peak systolic, end-diastolic, and mean velocities, as well as pulsatility index of the MCA in infants with HLHS (n = 18) at baseline and at 2, 4, and 6 months of age. Developmental assessment was performed at 6 months of age. Results of TCD and development were compared to healthy control subjects (n = 6) and normative data. Overall, peak systolic velocity (p = 0.0031), end-diastolic velocity (p < 0.0001), and mean velocity (p < 0.0001) were significantly lower and pulsatility index (p = 0.0011) significantly higher in the HLHS group compared to the control group. A significant increase in change over time was noted for peak systolic velocity (p < 0.0016) and mean velocity (p < 0.0046). There was no significant correlation between TCD variables and development scores. TCD values in 5-6 months old infants with HLHS who undergo hybrid stage I palliation had consistently lower blood flow velocities than control infants; however, pulsatility index was slightly higher. No correlation between TCD measurements and measures of cognitive, language, and motor skills were noted.


Assuntos
Circulação Cerebrovascular/fisiologia , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Procedimentos de Norwood/efeitos adversos , Velocidade do Fluxo Sanguíneo/fisiologia , Desenvolvimento Infantil/fisiologia , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Lactente , Recém-Nascido , Estudos Longitudinais , Masculino , Artéria Cerebral Média/diagnóstico por imagem , Artéria Cerebral Média/fisiopatologia , Procedimentos de Norwood/métodos , Cuidados Paliativos/métodos , Estudos Prospectivos , Ultrassonografia Doppler Transcraniana/métodos
2.
Pediatr Cardiol ; 36(3): 685-91, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25380966

RESUMO

Motor skills and neurodevelopment in infants with hypoplastic left heart syndrome (HLHS) who have undergone Hybrid Stage I palliation is unknown. The purpose of this study is to assess early neurodevelopment in infants with HLHS after Hybrid Stage I palliation. Developmental assessment was performed in HLHS infants who underwent Hybrid Stage I palliation at 2 and 4 months of age using the Test of Infant Motor Performance, and at 6 months of age, prior to undergoing the second staged surgery, using the Bayley Scales of Infant and Toddler Development, 3rd edition (Bayley-III). Results were compared to healthy control subjects and norm-referenced data. The HLHS group scored between -1 and -2 standard deviations (SD) below the mean at 2 months of age (p = 0.002), and within -1 SD of the mean, at 4 months of age (p = 0.0019), on the TIMP. Compared to the control group, composite motor skills were significantly lower at 6 months of age on the Bayley-III in the HLHS group (p = 0.0489), however, not significant for cognitive (p = 0.29) or language (p = 0.68). Percentile rank motor scores were 17 ± 20 % in the HLHS group compared to 85 ± 12 % for the healthy age-matched control group. Infants with HLHS who undergo Hybrid Stage I palliation score lower on standardized motor skill tests compared to healthy age-matched controls and the norm-referenced population. This suggests that infants with HLHS have poorer motor skill performance than typically developing infants at 6 months of age.


Assuntos
Desenvolvimento Infantil , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Destreza Motora , Cuidados Paliativos/métodos , Linguagem Infantil , Cognição , Feminino , Humanos , Síndrome do Coração Esquerdo Hipoplásico/fisiopatologia , Síndrome do Coração Esquerdo Hipoplásico/psicologia , Lactente , Masculino , Testes Neuropsicológicos , Fatores de Tempo , Resultado do Tratamento
3.
Prog Pediatr Cardiol ; 39(2 Pt B): 157-163, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29551876

RESUMO

Atrial switch operations for D-Transposition of the great arteries (D-TGA) were performed until the late 20th century. These patients have substantial rates of re-operation, particularly for baffle related complications. This study sought to analyze the efficacy of percutaneous transcatheter intervention (PTI) for baffle leak and/or stenosis in adult atrial switch patients. Adult patients with a prior atrial switch operation who underwent heart catheterization (2002-2014) at a tertiary adult congenital heart disease referral center were retrospectively analyzed. In 58 adults (30 ± 8 years, 75% men, 14% New York Heart Association (NYHA) functional class ≥2) who underwent 79 catheterizations, PTI was attempted in 50 (baffle leak (n = 10, 20%), stenosis (n = 27, 54%), or both (n = 13, 26%)). PTI was successful in 45 and 5 were referred for surgery due to complex anatomy. A total of 40 bare metal stents, 18 covered stents, 16 occlusion devices, 2 angioplasties, and 1 endovascular graft were deployed. In isolated stenosis, there was improvement in NYHA functional class after PTI (8 vs. 0 patients were NYHA FC > 2, p = 0.004), which was matched by improvement in maximal oxygen consumption on exercise testing (VO2) (25.1 ± 5.4 mL/kg/min vs. 27.9 ± 9 mL/kg/min, p = 0.03). There were no procedure-related deaths or emergent surgeries in this cohort. This single-center cohort is the largest reported series of adult atrial switch operation patients who have undergone PTI for baffle stenosis and/or leak. We demonstrate that PTI with an expert multi-disciplinary team is a safe and effective alternative to surgery in adult patients with an atrial switch operation.

4.
Circ Cardiovasc Interv ; 17(7): e013729, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38666384

RESUMO

BACKGROUND: Transverse aortic arch obstruction is a challenging lesion for which stent implantation provides a potentially important alternate therapy. The objectives were to evaluate the technical, procedural, and medium-to-long-term clinical outcomes of percutaneous stent implantation of transverse aortic arch obstruction. METHODS: This is a retrospective, multicenter study of transverse aortic arch stent implantation. Univariable and multivariable analyses were performed. RESULTS: Index catheterization included 187 stent implants in 146 patients. The median age is 14.3 years (interquartile range, 9.3-19), weight is 53 kg (30-69), and follow-up is 53 months (12-120). The most common stent design was open cell (n=90, 48%). Stents overlapped 142 arch vessels (37 carotid arteries) in 118 (81%) cases. Technical and procedural success rates were 100% and 88%, respectively. Lower weight (P=0.018), body surface area (P=0.013), and minimum-to-descending aortic diameter ratio (P<0.001) were associated with higher baseline aortic gradient. The residual gradient was inversely associated with implant and final dilation diameters (P<0.001). The combined incidence of aortic injury and stent-related complications was 14%. There were no reports of abnormal brain scans or stroke. Blood pressure cuff gradient, echocardiographic arch velocity, and hypertension rates improved within 1-year follow-up with increased antihypertensive medication use. Reintervention was reported in 60 (41%) patients at a median of 84 (22-148) months to first reintervention. On multivariable logistic regression, residual aortic gradient >10 mm Hg was associated with increased odds of reintervention at all time points when controlling for each final dilation diameter, weight, and minimum-to-descending aortic diameter ratio. CONCLUSIONS: Transverse aortic arch stent implantation has high rates of technical, procedural, and medium-to-long-term clinical success. Aortic gradient >10 mm Hg is associated with increased odds of reintervention at 1-year and most recent follow-ups. Open cell stent design was frequently used for its advantages in conformability, perfusion of arch vessels, low fracture rate, and the ability to perform effective angioplasty of side cells.


Assuntos
Angioplastia com Balão , Aorta Torácica , Desenho de Prótese , Stents , Humanos , Estudos Retrospectivos , Masculino , Feminino , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/cirurgia , Aorta Torácica/fisiopatologia , Resultado do Tratamento , Fatores de Tempo , Fatores de Risco , Adolescente , Adulto Jovem , Angioplastia com Balão/instrumentação , Angioplastia com Balão/efeitos adversos , Criança , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/terapia , Doenças da Aorta/fisiopatologia , Arteriopatias Oclusivas/diagnóstico por imagem , Arteriopatias Oclusivas/fisiopatologia , Arteriopatias Oclusivas/terapia , Constrição Patológica , Estados Unidos , Aortografia
5.
Catheter Cardiovasc Interv ; 82(5): 816-23, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23359563

RESUMO

OBJECTIVES: We report the Melody valve implanted and/or expanded to 24-mm diameter. BACKGROUND: The Medtronic Melody valve has been implanted up to 22 mm in the pulmonary position for over a decade. METHODS: A retrospective chart review was performed on 82 patients who underwent Melody valve implant. Technical implant method, pre- and postimplant echocardiographic findings, and initial follow-up were reviewed. RESULTS: Between 04/2008 and 12/2011, 13 Melody valves were successfully implanted in 11 patients, median age 35 years (range 16-61 years), in the pulmonary (bioprosthetic valve, right ventricle to pulmonary artery conduit, native valve) position (n = 9), tricuspid position (bioprosthetic valve n = 3), and aortic position (bioprosthetic valve n = 1). Ten valves were delivered on a 24-mm balloon in balloon catheter and three were implanted using a 22-mm Ensemble balloon delivery system, followed by postdilation using a 24-mm × 2-cm Atlas balloon catheter. Postimplant, the median peak systolic gradient across the pulmonary valve was 7 mm Hg and median gradient across the tricuspid valve was 3 mm Hg. There was no change in gradient across the Melody valve in the aortic position where valve prosthesis-patient mismatch was present. Postimplant intracardiac echocardiography demonstrated none or mild valve regurgitation. No more than mild regurgitation was noted at a median follow-up of 9.5 months. CONCLUSIONS: The Melody valve can be implanted at 24 mm in the stenotic/regurgitant bioprosthetic pulmonary, tricuspid, and aortic valve, dysfunctional right ventricle to pulmonary artery conduit, and the native right ventricular outflow tract, whereas the valve remains competent with only mild regurgitation.


Assuntos
Cateterismo Cardíaco/instrumentação , Doenças das Valvas Cardíacas/terapia , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Desenho de Prótese , Valva Pulmonar , Obstrução do Fluxo Ventricular Externo/terapia , Adolescente , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valvuloplastia com Balão , Bioprótese , Cateterismo Cardíaco/efeitos adversos , Doenças das Valvas Cardíacas/diagnóstico , Doenças das Valvas Cardíacas/fisiopatologia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico , Insuficiência da Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/terapia , Estenose da Valva Pulmonar/diagnóstico , Estenose da Valva Pulmonar/fisiopatologia , Estenose da Valva Pulmonar/terapia , Estudos Retrospectivos , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Ultrassonografia , Obstrução do Fluxo Ventricular Externo/diagnóstico , Obstrução do Fluxo Ventricular Externo/fisiopatologia , Adulto Jovem
6.
Mol Ther Methods Clin Dev ; 27: 47-60, 2022 Dec 08.
Artigo em Inglês | MEDLINE | ID: mdl-36186954

RESUMO

In a phase 1/2, open-label dose escalation trial, we delivered rAAVrh74.MCK.GALGT2 (also B4GALNT2) bilaterally to the legs of two boys with Duchenne muscular dystrophy using intravascular limb infusion. Subject 1 (age 8.9 years at dosing) received 2.5 × 1013 vector genome (vg)/kg per leg (5 × 1013 vg/kg total) and subject 2 (age 6.9 years at dosing) received 5 × 1013 vg/kg per leg (1 × 1014 vg/kg total). No serious adverse events were observed. Muscle biopsy evaluated 3 or 4 months post treatment versus baseline showed evidence of GALGT2 gene expression and GALGT2-induced muscle cell glycosylation. Functionally, subject 1 showed a decline in 6-min walk test (6MWT) distance; an increase in time to run 100 m, and a decline in North Star Ambulatory Assessment (NSAA) score until ambulation was lost at 24 months. Subject 2, treated at a younger age and at a higher dose, demonstrated an improvement over 24 months in NSAA score (from 20 to 23 points), an increase in 6MWT distance (from 405 to 478 m), and only a minimal increase in 100 m time (45.6-48.4 s). These data suggest preliminary safety at a dose of 1 × 1014 vg/kg and functional stabilization in one patient.

7.
Circ Cardiovasc Interv ; 14(2): e009399, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33544625

RESUMO

BACKGROUND: Stent implantation (SI) is more effective than balloon angioplasty for the treatment of coarctation of the aorta (CoA). Due to technical factors, balloon angioplasty is more commonly performed in small patients. We sought to evaluate outcomes of percutaneous adult sized SI for the treatment of CoA in small patients. METHODS: A single-center retrospective review of all patients ≤20 kg who underwent percutaneous adult sized SI for native or recurrent CoA from 2004 to 2015 was performed. RESULTS: Thirty-nine patients (20 patients ≤10 kg) were identified, with 28 (71.8%) having recurrent CoA and 22 (56.4%) previously failed balloon angioplasty. At the time of SI, the median (range) patient age and weight were 1.1 (0.3-7.9) years and 10 (5.5-20.4) kg, respectively. SI resulted in significant improvements in the median gradient (26 mm Hg [interquartile range (IQR), 18-42] to 0 mm Hg [IQR, 0-2]; P< 0.05) and median minimum diameter (3.6 mm [IQR, 2.4-4.8] to 7.7 mm [IQR, 6.5-9.4]; P<0.05). Seven patients (18%) had procedural adverse events. Twenty-seven (69%) patients underwent elective reintervention at a median time of 49.3 (IQR, 26.5-63.2) months from SI, with 8 (21%) stents requiring repeat SI for stent fracture. Over a median follow-up of 67.2 (IQR, 33.8-116.1) months, 25 patients (69%) were without hypertension or blood pressure gradient. Three (11%) patients developed femoral arterial occlusion. CONCLUSIONS: Adult sized SI is an alternative to surgical intervention for small patients with CoA. SI carries a risk of access-related complications, which may improve with the development of lower profile stents with adult sized maximum diameters.


Assuntos
Coartação Aórtica , Adulto , Angioplastia com Balão/efeitos adversos , Coartação Aórtica/diagnóstico por imagem , Coartação Aórtica/cirurgia , Criança , Seguimentos , Humanos , Estudos Retrospectivos , Stents , Resultado do Tratamento
9.
Circ Cardiovasc Interv ; 13(1): e008320, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-32525412

RESUMO

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) was designed for treatment of postoperative pulmonary valve regurgitation in patients with repaired right ventricular outflow tracts. METHODS: The Native TPV EFS (Early Feasibility Study) is a prospective, multicenter, nonrandomized feasibility study. Three-year outcomes are reported. RESULTS: Of 20 implanted patients, 17 completed 3-year follow-up (maximum: 4.1 years). There were no deaths and 2 early explants. One patient did not complete the 3-year visit. In patients with available 3-year echocardiographic data, 1 had a mild paravalvular leak and the rest had none/trace; 1 patient had mild pulmonary valve regurgitation and the remainder had none/trace. The 3-year mean right ventricular outflow tract echocardiographic gradient was 15.7±5.5 mm Hg. Radiographically, no late frame fractures or erosions were identified. At 2 years, 2 patients presented with an increased echocardiographic outflow gradient (1 mixed lesion with moderate/severe pulmonary valve regurgitation). Computed tomography scans identified neointimal tissue ingrowth within the stent frame in both patients, and they were treated successfully with a transcatheter valve-in-valve procedure (Melody TPV). Additional follow-up computed tomography scans performed at 3.2±0.5 years after implant were obtained in 16 patients and revealed luminal tissue thickening at the inflow and outflow portion of the frame with no significant alteration of the valve housing. CONCLUSIONS: Three-year results from the Native TPV EFS revealed stable Harmony TPV device position, good valve function in most, and the absence of moderate/severe paravalvular leak and significant late frame fractures. Two patients developed significant neointimal proliferation requiring valve-in-valve treatment, while all others had no clinically significant right ventricular outflow tract obstruction. CLINICAL TRIAL REGISTRATION: URL: https://www.clinicaltrials.gov. Unique identifier: NCT01762124.


Assuntos
Bioprótese , Cateterismo Cardíaco/instrumentação , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Canadá , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Adulto Jovem
10.
Sci Transl Med ; 12(537)2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32238576

RESUMO

We developed a tissue-engineered vascular graft (TEVG) for use in children and present results of a U.S. Food and Drug Administration (FDA)-approved clinical trial evaluating this graft in patients with single-ventricle cardiac anomalies. The TEVG was used as a Fontan conduit to connect the inferior vena cava and pulmonary artery, but a high incidence of graft narrowing manifested within the first 6 months, which was treated successfully with angioplasty. To elucidate mechanisms underlying this early stenosis, we used a data-informed, computational model to perform in silico parametric studies of TEVG development. The simulations predicted early stenosis as observed in our clinical trial but suggested further that such narrowing could reverse spontaneously through an inflammation-driven, mechano-mediated mechanism. We tested this unexpected, model-generated hypothesis by implanting TEVGs in an ovine inferior vena cava interposition graft model, which confirmed the prediction that TEVG stenosis resolved spontaneously and was typically well tolerated. These findings have important implications for our translational research because they suggest that angioplasty may be safely avoided in patients with asymptomatic early stenosis, although there will remain a need for appropriate medical monitoring. The simulations further predicted that the degree of reversible narrowing can be mitigated by altering the scaffold design to attenuate early inflammation and increase mechano-sensing by the synthetic cells, thus suggesting a new paradigm for optimizing next-generation TEVGs. We submit that there is considerable translational advantage to combined computational-experimental studies when designing cutting-edge technologies and their clinical management.


Assuntos
Prótese Vascular , Constrição Patológica , Engenharia Tecidual , Animais , Criança , Constrição Patológica/terapia , Humanos , Ovinos , Estados Unidos
11.
Congenit Heart Dis ; 14(2): 297-304, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30548926

RESUMO

OBJECTIVE: We sought to describe the leaflet morphology variation in the Melody Transcatheter Pulmonary Valve (TPV) and evaluate associated outcomes. The Melody TPV is constructed from harvested bovine jugular venous valves which have been rigorously tested. Natural anatomic leaflet variations are seen in the Melody TPV but have not been evaluated. DESIGN: A Melody TPV leaflet morphology classification system was devised after reviewing a subset of photographed and implanted TPVs. All images were blindly reviewed by implanters and classified. Midterm hemodynamic outcomes and complications of the Melody TPVs were compared by leaflet morphology. RESULTS: Photographed Melody TPVs implanted between 2011 and 2016 (n = 62) were categorized into the following leaflet morphology types: A-symmetric trileaflet (47%); B-asymmetric trileaflet with a single small leaflet (32%); C-asymmetric trileaflet with a single large leaflet (16%); D-rudimentary leaflet with near bicuspid appearance (5%). Acceptable hemodynamic function at 6 months postimplantation was seen in 97.5% of valves. Over a median follow-up of 1.5 years (range 0-4.4 years), two TPVs (Type A) had > mild regurgitation. Nine TPVs developed complications (endocarditis, 3; stent fracture, 2; refractory arrhythmia, 1; conduit replacement, 2; death, 1), of which 6 required reintervention. There was no significant difference in outcomes based on Melody TPV leaflet morphology type. CONCLUSIONS: The Melody TPV can be classified into one of four categories based on leaflet morphology. Study outcomes were not associated with leaflet morphology. Further documentation and evaluation of Melody TPV morphology may lead to better understanding of this technology.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/diagnóstico por imagem , Adolescente , Adulto , Criança , Feminino , Seguimentos , Humanos , Masculino , Desenho de Prótese , Valva Pulmonar/cirurgia , Insuficiência da Valva Pulmonar/classificação , Insuficiência da Valva Pulmonar/diagnóstico , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento , Gravação em Vídeo , Adulto Jovem
12.
Mol Ther Methods Clin Dev ; 10: 89-104, 2018 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-30073180

RESUMO

Recombinant adeno-associated virus (rAAV)rh74.MCK.GALGT2 is a muscle-specific gene therapy that is being developed to treat forms of muscular dystrophy. Here we report on an isolated limb infusion technique in a non-human primate model, where hindlimb blood flow is transiently isolated using balloon catheters to concentrate vector in targeted leg muscles. A bilateral dose of 2.5 × 1013 vector genomes (vg)/kg/limb was sufficient to induce GALGT2-induced glycosylation in 10%-60% of skeletal myofibers in all leg muscles examined. There was a 19-fold ± 6-fold average limb-wide increase in vector genomes per microgram genomic DNA at a bilateral dose of 2.5 × 1013 vg/kg/limb compared with a bilateral dose of 6 × 1012 vg/kg/limb. A unilateral dose of 6 × 1013 vg/kg/limb showed a 12- ± 3-fold increase in treated limb muscles compared to contralateral untreated limb muscles, which received vector only after release into the systemic circulation from the treated limb. Variability in AAV biodistribution between different segments of the same muscle was 125% ± 18% for any given dose, while variability between the same muscle for any given treatment dose was 45% ± 7%. These experiments demonstrate that treatment of muscles throughout the leg with rAAVrh74.MCK.GALGT2 can be accomplished safely using an isolated limb infusion technique, where balloon catheters transiently isolate the limb vasculature, but that intra- and inter-muscle transduction variability is a significant issue.

13.
JACC Cardiovasc Interv ; 10(17): 1763-1773, 2017 09 11.
Artigo em Inglês | MEDLINE | ID: mdl-28882284

RESUMO

OBJECTIVES: This study sought to obtain in vivo data to confirm assumptions on device loading conditions and assess procedural feasibility, safety, and valve performance. BACKGROUND: The Harmony transcatheter pulmonary valve (Medtronic, Minneapolis, Minnesota) was designed for patients with severe pulmonary regurgitation who require pulmonary valve replacement. METHODS: Three sites participated in this first Food and Drug Administration-approved early feasibility study using an innovative device design to accommodate the complex anatomy of the right ventricular outflow tract. Potentially eligible patients underwent review by a screening committee to determine implant eligibility. Six-month outcomes are reported. RESULTS: Between May 2013 and May 2015, 66 subjects were enrolled, and 21 were approved for implant and underwent catheterization; 20 were implanted. Catheterized patients had a median age of 25 years, were predominantly diagnosed with tetralogy of Fallot (95%), had severe pulmonary regurgitation (95%), and had trivial or mild stenosis. The device was delivered in the desired location in 19 of 20 (95%) patients. Proximal migration occurred in 1 patient during delivery system removal. Two devices were surgically explanted. Premature ventricular contractions related to the procedure were reported in 3 patients; 2 were resolved without treatment. One patient had ventricular arrhythmias that required treatment and later were resolved. At 1 month, echocardiography revealed none or trivial pulmonary regurgitation in all and a mean right ventricular outflow tract gradient of 16 ± 8 mm Hg (range 6 to 31 mm Hg). CONCLUSIONS: In this feasibility study of the Harmony transcatheter pulmonary valve device, there was high procedural success and safety, and favorable acute device performance.


Assuntos
Cateterismo Cardíaco/instrumentação , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adolescente , Adulto , Boston , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Criança , Estudos de Viabilidade , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Ohio , Ontário , Complicações Pós-Operatórias/etiologia , Estudos Prospectivos , Desenho de Prótese , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/fisiopatologia , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/fisiopatologia , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
14.
J Cardiovasc Transl Res ; 10(2): 128-138, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28097523

RESUMO

Patients who undergo implantation of a tissue-engineered vascular graft (TEVG) for congenital cardiac anomalies are monitored with echocardiography, followed by magnetic resonance imaging or angiography when indicated. While these methods provide data regarding the lumen, minimal information regarding neotissue formation is obtained. Intravascular ultrasound (IVUS) has previously been used in a variety of conditions to evaluate the vessel wall. The purpose of this study was to evaluate the utility of IVUS for evaluation of TEVGs in our ovine model. Eight sheep underwent implantation of TEVGs either unseeded or seeded with bone marrow-derived mononuclear cells. Angiography, IVUS, and histology were directly compared. Endothelium, tunica media, and graft were identifiable on IVUS and histology at multiple time points. There was strong agreement between IVUS and angiography for evaluation of luminal diameter. IVUS offers a valuable tool to evaluate the changes within TEVGs, and clinical translation of this application is warranted.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Transplante de Medula Óssea , Engenharia Tecidual/métodos , Alicerces Teciduais , Ultrassonografia de Intervenção , Veia Cava Inferior/cirurgia , Animais , Implante de Prótese Vascular/efeitos adversos , Células Cultivadas , Modelos Animais , Flebografia , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/patologia , Desenho de Prótese , Carneiro Doméstico , Fatores de Tempo , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/patologia
15.
Am J Cardiol ; 120(8): 1387-1392, 2017 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-28823485

RESUMO

This early feasibility study was designed to obtain in vivo data to confirm assumptions on device loading conditions of the Medtronic Harmony transcatheter pulmonary valve (TPV). Secondary objectives included procedural feasibility, safety, and valve performance. The Harmony TPV was developed for nonsurgical pulmonary valve replacement in non-right ventricle-pulmonary artery conduit patients. The Native Outflow Tract TPV Research Clinical Study was the first study approved under the Food and Drug Administration Early Feasibility Study guidance. Enrollment required that patient anatomy be precisely matched to the single-size Harmony TPV implant, necessitating a rigorous selection process. The study was nonrandomized, prospective, and performed at 3 sites. All patients met standard indications for surgical pulmonary valve replacement. The goal of the screening committee was to match the candidate anatomy to predetermined engineering criteria thought to be predictive of secure Harmony TPV implantation for the single-size device under study. A majority of the screening committee was required to recommend a patient as eligible for implant. A total of 270 patients underwent prescreening cardiac magnetic resonance imaging, 66 were enrolled and received a computed tomography scan (24%), 21 met criteria for implant and were catheterized (8%), and 20 underwent implant. Nineteen of 20 met criteria for implant success. In conclusion, the Medtronic Harmony TPV represents an emerging therapeutic option for patients with complex postoperative right ventricular outflow tract failure. The initial clinical evaluation of this technology was unique, and the highly variable anatomy of this population required careful screening to ensure acceptable device fit.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Ventrículos do Coração/diagnóstico por imagem , Seleção de Pacientes , Insuficiência da Valva Pulmonar/cirurgia , Valva Pulmonar/cirurgia , Adulto , Estudos Clínicos como Assunto , Ecocardiografia , Estudos de Viabilidade , Feminino , Seguimentos , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Estudos Prospectivos , Insuficiência da Valva Pulmonar/diagnóstico , Fatores de Tempo , Resultado do Tratamento
16.
Crit Care Nurse ; 36(5): 48-55, 2016 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27694357

RESUMO

Hybrid stage I palliation combines cardiothoracic surgery and interventional transcatheter procedures for treatment of hypoplastic left heart syndrome. The approach is an alternative to the Norwood procedure, the traditional first stage of surgical palliation. Hybrid stage I palliation involves placing bilateral branch pulmonary artery bands and a patent ductus arteriosus stent through a median sternotomy, performed without cardiopulmonary bypass. The purpose of the bands is to control blood flow to the lungs and protect the pulmonary bed while the stent sustains systemic cardiac output. A balloon atrial septostomy is performed to create an atrial septal defect for unobstructed blood flow from the left atrium to the right atrium. The second stage of palliative surgery is the comprehensive stage II, which incorporates removal of the stent and pulmonary artery bands, atrial septectomy, anastomosis of the diminutive ascending aorta to the main pulmonary artery, aortic arch augmentation, and bidirectional cavopulmonary anastomosis. The traditional Fontan procedure completes the series of palliation.


Assuntos
Cateterismo Cardíaco/métodos , Técnica de Fontan/métodos , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Cuidados Paliativos/métodos , Artéria Pulmonar/cirurgia , Débito Cardíaco/fisiologia , Terapia Combinada , Feminino , Seguimentos , Septos Cardíacos/cirurgia , Humanos , Síndrome do Coração Esquerdo Hipoplásico/diagnóstico , Síndrome do Coração Esquerdo Hipoplásico/mortalidade , Recém-Nascido , Masculino , Medição de Risco , Esternotomia/métodos , Taxa de Sobrevida , Resultado do Tratamento
17.
J Am Heart Assoc ; 5(2)2016 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-26873689

RESUMO

BACKGROUND: Percutaneous closure of patent ductus arteriosus (PDA) in term neonates is established, but data regarding outcomes in infants born very preterm (<32 weeks of gestation) are minimal, and no published criteria exist establishing a minimal weight of 4 kg as a suitable cutoff. We sought to analyze outcomes of percutaneous PDA occlusion in infants born very preterm and referred for PDA closure at weights <4 kg. METHODS AND RESULTS: Retrospective analysis (January 2005-January 2014) was done at a single pediatric center. Procedural successes and adverse events were recorded. Markers of respiratory status (need for mechanical ventilation) were determined, with comparisons made before and after catheterization. A total of 52 very preterm infants with a median procedural weight of 2.9 kg (range 1.2-3.9 kg) underwent attempted PDA closure. Twenty-five percent (13/52) of infants were <2.5 kg. Successful device placement was achieved in 46/52 (88%) of infants. An adverse event occurred in 33% of cases, with an acute arterial injury the most common complication. We observed no association between weight at time of procedure and the risk of an adverse event. No deaths were attributable to the PDA closure. Compared to precatheterization trends, percutaneous PDA closure resulted in improved respiratory status, including less exposure to mechanical ventilation (mixed effects logistic model, P<0.01). CONCLUSIONS: Among infants born very preterm, percutaneous PDA closure at weights <4 kg is generally safe and may improve respiratory health, but risk of arterial injury is noteworthy. Randomized clinical trials are needed to assess clinically relevant differences in outcomes following percutaneous PDA closure versus alternative (surgical ligation) management strategies.


Assuntos
Cateterismo Cardíaco , Permeabilidade do Canal Arterial/terapia , Recém-Nascido Prematuro , Peso ao Nascer , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Permeabilidade do Canal Arterial/diagnóstico , Permeabilidade do Canal Arterial/fisiopatologia , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Recém-Nascido de Baixo Peso , Modelos Lineares , Modelos Logísticos , Masculino , Recuperação de Função Fisiológica , Respiração , Respiração Artificial , Estudos Retrospectivos , Fatores de Risco , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento , Lesões do Sistema Vascular/etiologia
18.
World J Pediatr Congenit Heart Surg ; 6(4): 630-9, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26467877

RESUMO

Pulmonary atresia with ventricular septal defect and major aortopulmonary collateral arteries (PA/VSD/MAPCAs) is a rare and complex congenital cardiac lesion that has historically carried a poor prognosis. With advancements in surgical management, we have seen an improvement in the outcomes for children affected by this disease. However, this population continues to present challenges due to the complex anatomy and physiology associated with PA/VSD/MAPCA. This summary of material presented during one of the nursing sessions of the 2014 Meeting of the Pediatric Cardiac Intensive Care Society provides an overview for those in cardiac intensive care units who do not have a large experience with this lesion. We will review the anatomy, physiology, surgical approach, postoperative management strategies, and cardiac catheter intervention options for PA/VSD/MAPCAs. We will also discuss recent innovations that may lead to continued improvement in outcomes for this challenging patient population.


Assuntos
Aorta Torácica/anormalidades , Procedimentos Cirúrgicos Cardíacos/métodos , Circulação Colateral , Defeitos dos Septos Cardíacos/cirurgia , Artéria Pulmonar/anormalidades , Atresia Pulmonar/cirurgia , Aorta Torácica/fisiopatologia , Aorta Torácica/cirurgia , Defeitos dos Septos Cardíacos/fisiopatologia , Humanos , Artéria Pulmonar/fisiopatologia , Artéria Pulmonar/cirurgia , Atresia Pulmonar/fisiopatologia
19.
J Vet Cardiol ; 17(4): 304-13, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26515420

RESUMO

A 7-month-old Irish Setter underwent transcatheter therapy of a muscular ventricular septal defect (VSD) and pulmonary valve stenosis. Standard devices for muscular VSD closure could not span the interventricular septum due to right ventricular hypertrophy, and an Amplatzer post-infarction muscular VSD occluder with a wider waist was successfully implanted. Following VSD closure, inflation of the balloon dilation catheter during balloon pulmonary valvuloplasty resulted in iatrogenic embolization of the VSD occluder to the left ventricular outflow tract. Retrieval and reimplantation of the device was achieved using a snare catheter. This report describes a potential complication and management during intracardiac device implantation in a dog. Additionally, the case illustrates that the Amplatzer post-infarction muscular VSD occluder holds potential value in animals with a hypertrophied interventricular septum that cannot be spanned using a conventional device.


Assuntos
Doenças do Cão/terapia , Embolização Terapêutica/instrumentação , Comunicação Interventricular/veterinária , Complicações Pós-Operatórias/veterinária , Dispositivo para Oclusão Septal/veterinária , Animais , Diagnóstico Diferencial , Cães , Falha de Equipamento/veterinária , Comunicação Interventricular/terapia , Doença Iatrogênica/veterinária , Masculino , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Dispositivo para Oclusão Septal/efeitos adversos
20.
J Vet Cardiol ; 16(3): 205-14, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25087648

RESUMO

Two dogs with severe dysplastic pulmonary valve stenosis and right-to-left shunting defects (patent foramen ovale, perimembranous ventricular septal defect) underwent palliative stenting of the right ventricular outflow tract and pulmonary valve annulus using balloon expandable stents. One dog received 2 over-lapping bare metal stents placed 7 months apart; the other received a single covered stent. Both procedures were considered technically successful with a reduction in the transpulmonary valve pressure gradient from 202 to 90 mmHg in 1 dog and from 168 to 95 mmHg in the other. Clinical signs of exercise intolerance and syncope were temporarily resolved in both dogs. However, progressive right ventricular concentric hypertrophy, recurrent stenosis, and erythrocytosis were observed over the subsequent 6 months leading to poor long-term outcomes. Stenting of the right ventricular outflow tract is feasible in dogs with severe dysplastic pulmonary valve stenosis, though further study and optimization of the procedure is required.


Assuntos
Doenças do Cão/terapia , Forame Oval Patente/veterinária , Comunicação Interventricular/veterinária , Estenose da Valva Pulmonar/veterinária , Stents/veterinária , Animais , Cateterismo/veterinária , Diagnóstico Diferencial , Cães , Ecocardiografia Doppler em Cores/veterinária , Forame Oval Patente/complicações , Comunicação Interventricular/complicações , Ventrículos do Coração/cirurgia , Masculino , Estenose da Valva Pulmonar/terapia , Índice de Gravidade de Doença
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA