Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25
Filtrar
1.
Anal Chem ; 96(37): 14715-14719, 2024 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-39229957

RESUMO

Polymer conjugation has risen in importance over the past three decades as a means of increasing the in vivo half-life of biotherapeutics, with benefits including better stability, greater drug efficacy, and lower toxicity. However, the intrinsic variability of polymer synthesis results in products with broad distributions in chain length and branching structure, complicating quality control for successful functionalization and downstream conjugation. Frequently, a combination of several analytical techniques is required for comprehensive characterization. While liquid chromatography-mass spectrometry (LC-MS) is a powerful platform that can provide detailed molecular features of polymers, the mass spectra are inherently challenging to interpret due to high mass polydispersity and overlapping charge distributions. Here, by leveraging Fourier transform-based deconvolution and macromolecular mass defect analysis, we demonstrate a new way to streamline pharmaceutical polymer analysis, shedding light on polymer size, composition, branching, and end-group functionalization with the capability for reaction monitoring.


Assuntos
Análise de Fourier , Espectrometria de Massas , Polímeros , Polímeros/química , Espectrometria de Massas/métodos , Cromatografia Líquida/métodos , Substâncias Macromoleculares/química , Peso Molecular , Espectrometria de Massa com Cromatografia Líquida
2.
Anal Chem ; 96(15): 5860-5868, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38567987

RESUMO

Supramolecular hydrogels formed through polymer-nanoparticle interactions are promising biocompatible materials for translational medicines. This class of hydrogels exhibits shear-thinning behavior and rapid recovery of mechanical properties, providing desirable attributes for formulating sprayable and injectable therapeutics. Characterization of hydrogel composition and loading of encapsulated drugs is critical to achieving the desired rheological behavior as well as tunable in vitro and in vivo payload release kinetics. However, quantitation of hydrogel composition is challenging due to material complexity, heterogeneity, high molecular weight, and the lack of chromophores. Here, we present a label-free approach to simultaneously determine hydrogel polymeric components and encapsulated payloads by coupling a reversed phase liquid chromatographic method with a charged aerosol detector (RPLC-CAD). The hydrogel studied consists of modified hydroxypropylmethylcellulose, self-assembled PEG-b-PLA nanoparticles, and a therapeutic compound, bimatoprost. The three components were resolved and quantitated using the RPLC-CAD method with a C4 stationary phase. The method demonstrated robust performance, applicability to alternative cargos (i.e., proteins) and was suitable for composition analysis as well as for evaluating in vitro release of cargos from the hydrogel. Moreover, this method can be used to monitor polymer degradation and material stability, which can be further elucidated by coupling the RPLC method with (1) a multi-angle light scattering detector (RPLC-MALS) or (2) high resolution mass spectrometry (RPLC-MS) and a Fourier-transform based deconvolution algorithm. We envision that this analytical strategy could be generalized to characterize critical quality attributes of other classes of supramolecular hydrogels, establish structure-property relationships, and provide rational design guidance in hydrogel drug product development.


Assuntos
Hidrogéis , Nanopartículas , Hidrogéis/química , Cromatografia de Fase Reversa/métodos , Polietilenoglicóis/química , Aerossóis
3.
Anal Chem ; 95(6): 3180-3186, 2023 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-36606446

RESUMO

In recent years, CRISPR-Cas9 genome editing has become an important technology in biomedical research and has demonstrated tremendous therapeutic potential. With Cas9 endonuclease, the use of single guide ribonucleic acids (sgRNAs) allows for sequence-specific cutting on target double-stranded deoxyribonucleic acids. Therefore, the design and quality of sgRNAs can greatly affect the efficiency and specificity of genome editing. Mass spectrometry (MS) has been a powerful tool to detect molecular features and sequence a variety of biomolecules; however, as the sizes of oligonucleotides get larger, it becomes more challenging to desalt samples and achieve high-quality intact spectra with effective fragmentation. Here, we develop a simple but effective online column-based clean-up method (reversed-phase column in a size exclusion mode) that removes formulation salts and metal adducts from larger oligonucleotides upon entering the mass spectrometer in a consistent manner. Using the top-down approach without any nuclease digestion, we characterized and sequenced 100-nucleotide-long sgRNAs by higher-energy collision dissociation (HCD), collision-induced dissociation (CID), ultraviolet photodissociation (UVPD), and activated electron photodetachment (a-EPD). In a single 10 min liquid chromatography-tandem MS (LC-MS/MS) run, CID yielded the best sequence coverage, of 67%. When adding complementary UVPD and a-EPD runs, we achieved 80% overall sequence coverage and 100% cleavages for the variable sequence, the first 20 nucleotides from the 5' end. This LC-MS/MS platform provides a facile top-down workflow to analyze and sequence larger chemically modified oligonucleotides with no sample treatment.


Assuntos
Espectrometria de Massas em Tandem , Raios Ultravioleta , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida , Elétrons
4.
Nat Methods ; 16(5): 417-420, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30988469

RESUMO

We report the identification of a photocleavable anionic surfactant, 4-hexylphenylazosulfonate (Azo), which can be rapidly degraded by ultraviolet irradiation, for top-down proteomics. Azo can effectively solubilize proteins with performance comparable to that of sodium dodecyl sulfate (SDS) and is compatible with mass spectrometry. Azo-aided top-down proteomics enables the solubilization of membrane proteins for comprehensive characterization of post-translational modifications. Moreover, Azo is simple to synthesize and can be used as a general SDS replacement in SDS-polyacrylamide gel electrophoresis.


Assuntos
Compostos Azo/química , Eletroforese em Gel de Poliacrilamida/métodos , Proteômica/métodos , Dodecilsulfato de Sódio/química , Tensoativos/química , Compostos Azo/efeitos da radiação , Interações Hidrofóbicas e Hidrofílicas , Espectrometria de Massas , Proteínas de Membrana/análise , Fotólise , Dodecilsulfato de Sódio/efeitos da radiação , Solubilidade , Tensoativos/efeitos da radiação , Raios Ultravioleta
5.
Nat Methods ; 16(7): 587-594, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31249407

RESUMO

One gene can give rise to many functionally distinct proteoforms, each of which has a characteristic molecular mass. Top-down mass spectrometry enables the analysis of intact proteins and proteoforms. Here members of the Consortium for Top-Down Proteomics provide a decision tree that guides researchers to robust protocols for mass analysis of intact proteins (antibodies, membrane proteins and others) from mixtures of varying complexity. We also present cross-platform analytical benchmarks using a protein standard sample, to allow users to gauge their proficiency.


Assuntos
Benchmarking , Espectrometria de Massas/métodos , Proteínas/química , Desnaturação Proteica , Processamento de Proteína Pós-Traducional , Proteômica
6.
Biochemistry ; 60(14): 1108-1119, 2021 04 13.
Artigo em Inglês | MEDLINE | ID: mdl-33755420

RESUMO

Methods for maintaining membrane proteins in their native state after removal from the lipid bilayer are essential for the study of this important class of biomacromolecules. Common solubilization strategies range from the use of detergents to more complex systems that involve a polypeptide working in concert with lipids or detergents, such as nanodiscs, picodiscs, and peptidiscs, in which an engineered protein or synthetic peptide surrounds the membrane protein along with a lipid sheath. Picodiscs employ the protein saposin A, which naturally functions to facilitate lipid degradation in the lysozome. Saposin A-amphiphile complexes therefore tend to be most stable at acidic pH, which is not optimal for most membrane protein applications. In search of new picodisc assemblies, we have explored pairings of saposin A or other saposin proteins with a range of detergents, and we have identified a number of combinations that spontaneously co-assemble at neutral pH. The resulting picodiscs are stable for weeks and have been characterized by size-exclusion chromatography, native mass spectrometry, and small angle X-ray scattering. The new assemblies are formed by double-tail detergents rather than more traditional single-tail detergents; the double-tail detergents can be seen as structurally intermediate between single-tail detergents and common lipids. In addition to saposin A, an engineered variant of saposin B (designated saposin BW) forms picodisc assemblies. These findings provide a framework for future efforts to solubilize membrane proteins with multiple picodisc systems that were previously unknown.


Assuntos
Detergentes/química , Saposinas/química , Interações Hidrofóbicas e Hidrofílicas , Ligação Proteica , Engenharia de Proteínas , Estabilidade Proteica , Saposinas/genética
7.
Anal Chem ; 92(12): 8584-8590, 2020 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-32442374

RESUMO

A current trend in drug development involves the use of high molecular weight, branched, and functionalized polymers for protein conjugation and drug delivery. Accurately characterizing these polymers is critical to control the product quality, to monitor the stability, and ultimately to ensure the drug efficacy and patient safety. However, due to the heterogeneity in size, the multiplicity of functional groups, and the highly convoluted charge-distribution profile in mass spectra, the characterization of these polymers is highly challenging from both chromatography and mass spectrometry perspectives. To overcome these challenges, we developed a strategy utilizing charge-reduction mass spectrometry (CRMS) coupled with two-dimensional HPLC (2D-LC). We then applied the workflow to characterize a 40 kDa 8-arm polyethylene glycol (PEG) functionalized with a maleimide terminal group for protein conjugation. The development was carried out in stages, where first we focused on the development of a CRMS method to simplify the charge profile of the polymers and then coupled it to HPLC to obtain discernible mass spectra of key impurities and degradants. Second, the CRMS method was applied to an investigation of the size-variant impurity resolved by reversed-phase size-exclusion 2D-LC. Finally, a separate size-exclusion reversed-phase 2D-LC-CRMS method was developed to capture a wider range of process-related impurities and reaction intermediates from the PEG-maleimide polymers throughout the conjugation process. The combination of these experiments using the 2D-LC-CRMS strategy enables the sensitive characterization of the entire impurity profile of the high molecular weight multifunctionalized PEG-maleimide conjugation intermediate.


Assuntos
Maleimidas/química , Polietilenoglicóis/química , Proteínas/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas , Peso Molecular , Software
8.
Anal Chem ; 92(22): 15096-15103, 2020 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-33108180

RESUMO

Antibody drug conjugates (ADCs), which harness the high targeting specificity of monoclonal antibodies (mAb) with the potency of small molecule therapeutics, are one of the fastest growing pharmaceutical classes. Nevertheless, ADC conjugation techniques and processes may introduce intrinsic heterogeneity including primary sequence variants, varied drug-to-antibody ratio (DAR) species, and drug positional isomers, which must be monitored to ensure the safety and efficacy of ADCs. Liquid chromatography coupled to mass spectrometry (LC-MS) is a powerful tool for characterization of ADCs. However, the conventional bottom-up MS analysis workflows require an enzymatic digestion step which can be time consuming and may introduce artifactual modifications. Herein, we develop an online LC-MS/MS method for rapid analysis of reduced ADCs without digestion, enabling determination of DAR, characterization of the primary sequence, and localization of the drug conjugation site of the ADC using high-resolution Fourier transform ion cyclotron resonance (FTICR) MS. Specifically, a model cysteine-linked ADC was reduced to generate six unique subunits: light chain (Lc) without drug (Lc0), Lc with 1 drug (Lc1), heavy chain (Hc) without drug (Hc0), and Hc with 1-3 drugs (Hc1-3, respectively). A concurrent reduction strategy is applied to assess ADC subunits in both the partially reduced (intrachain disulfide bonds remain intact) and fully reduced (all disulfide bonds are cleaved) forms. The entire procedure including the sample preparation and LC-MS/MS takes less than 55 min, enabling rapid multiattribute analysis of ADCs.


Assuntos
Cromatografia Líquida/métodos , Ciclotrons , Análise de Fourier , Imunoconjugados/análise , Espectrometria de Massas em Tandem/instrumentação , Imunoconjugados/química , Isomerismo , Fatores de Tempo
9.
Anal Chem ; 91(6): 3835-3844, 2019 03 19.
Artigo em Inglês | MEDLINE | ID: mdl-30758949

RESUMO

Mass spectrometry (MS) based top-down proteomics provides rich information about proteoforms arising from combinatorial amino acid sequence variations and post-translational modifications (PTMs). Fourier transform ion cyclotron resonance (FT-ICR) MS affords ultrahigh resolving power and provides high-accuracy mass measurements, presenting a powerful tool for top-down MS characterization of proteoforms. However, the detection and characterization of large proteins from complex mixtures remain challenging due to the exponential decrease in S: N with increasing molecular weight (MW) and coeluting low-MW proteins; thus, size-based fractionation of complex protein mixtures prior to MS analysis is necessary. Here, we directly combine MS-compatible serial size exclusion chromatography (sSEC) fractionation with 12 T FT-ICR MS for targeted top-down characterization of proteins from complex mixtures extracted from human and swine heart tissue. Benefiting from the ultrahigh resolving power of FT-ICR, we isotopically resolved 31 distinct proteoforms (30-50 kDa) simultaneously in a single mass spectrum within a 100 m/ z window. Notably, within a 5 m/ z window, we obtained baseline isotopic resolution for 6 distinct large proteoforms (30-50 kDa). The ultrahigh resolving power of FT-ICR MS combined with sSEC fractionation enabled targeted top-down analysis of large proteoforms (>30 kDa) from the human heart proteome without extensive chromatographic separation or protein purification. Further separation of proteoforms inside the mass spectrometer (in-MS) allowed for isolation of individual proteoforms and targeted electron capture dissociation (ECD), yielding high sequence coverage. sSEC/FT-ICR ECD facilitated the identification and sequence characterization of important metabolic enzymes. This platform, which facilitates deep interrogation of proteoform primary structure, is highly tunable, allows for adjustment of MS and MS/MS parameters in real time, and can be utilized for a variety of complex protein mixtures.


Assuntos
Cromatografia em Gel/instrumentação , Ciclotrons , Análise de Fourier , Espectrometria de Massas/instrumentação , Proteômica/instrumentação , Humanos , Miocárdio/metabolismo
10.
Anal Chem ; 91(18): 11661-11669, 2019 09 17.
Artigo em Inglês | MEDLINE | ID: mdl-31442030

RESUMO

Antibody-drug conjugates (ADCs) are designed to combine the target specificity of monoclonal antibodies and potent cytotoxin drugs to achieve better therapeutic outcomes. Comprehensive evaluation of the quality attributes of ADCs is critical for drug development but remains challenging due to heterogeneity of the construct. Currently, peptide mapping with reversed-phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the predominant approach to characterize ADCs. However, it is suboptimal for sequence characterization and quantification of ADCs because it lacks a comprehensive view of coexisting variants and suffers from varying ionization effects of drug-conjugated peptides compared to unconjugated counterparts. Here, we present the first middle-down RPLC-MS analysis of both cysteine (Adcetris; BV) and lysine (Kadcyla; T-DM1) conjugated ADCs at the subunit level (∼25 kDa) with electron transfer dissociation (ETD). We successfully achieved high-resolution separation of subunit isomers arising from different drug conjugation and subsequently localized the conjugation sites. Moreover, we obtained a comprehensive overview of the microvariants associated with each subunits and characterized them such as oxidized variants with different sites. Furthermore, we observed relatively high levels of conjugation near complementarity-determining regions (CDRs) from the heavy chain but no drug conjugation near CDRs of light chain (Lc) from lysine conjugated T-DM1. Based on the extracted ion chromatograms, we accurately measured average drug to antibody ratio (DAR) values and relative occupancy of drug-conjugated subunits. Overall, the middle-down MS approach enables the evaluation of multiple quality attributes including DAR, positional isomers, conjugation sites, occupancy, and microvariants, which potentially opens up a new avenue to characterize ADCs.


Assuntos
Ado-Trastuzumab Emtansina/química , Brentuximab Vedotin/química , Imunoconjugados/análise , Imunoconjugados/química , Ado-Trastuzumab Emtansina/análise , Brentuximab Vedotin/análise , Cromatografia de Fase Reversa , Cisteína/química , Transporte de Elétrons , Lisina/química , Espectrometria de Massas em Tandem/métodos
11.
Anal Chem ; 90(12): 7135-7138, 2018 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-29846060

RESUMO

Therapeutic monoclonal antibodies (mAbs) are an important class of drugs for a wide spectrum of human diseases. Liquid chromatography (LC) coupled to mass spectrometry (MS) is one of the techniques in the forefront for comprehensive characterization of analytical attributes of mAbs. Among various protein chromatography modes, hydrophobic interaction chromatography (HIC) is a popular offline nondenaturing separation technique utilized to purify and analyze mAbs, typically with the use of non-MS-compatible mobile phases. Herein we demonstrate for the first time, the application of direct HIC-MS and HIC-tandem MS (MS/MS) with electron capture dissociation (ECD) for analyzing intact mAbs on quadrupole-time-of-flight (Q-TOF) and Fourier transform ion cyclotron resonance (FTICR) mass spectrometers, respectively. Our method allows for rapid determination of relative hydrophobicity, intact masses, and glycosylation profiles of mAbs as well as sequence and structural characterization of the complementarity-determining regions in an online configuration.


Assuntos
Anticorpos Monoclonais/análise , Interações Hidrofóbicas e Hidrofílicas , Cromatografia Líquida , Humanos , Espectrometria de Massas
12.
Anal Chem ; 90(8): 4935-4939, 2018 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-29565561

RESUMO

Protein phosphorylation is a ubiquitous and critical post-translational modification (PTM) involved in numerous cellular processes. Mass spectrometry (MS)-based proteomics has emerged as the preferred technology for protein identification, characterization, and quantification. Whereas ionization/detection efficiency of peptides in electrospray ionization (ESI)-MS are markedly influenced by the presence of phosphorylation, the physicochemical properties of intact proteins are assumed not to vary significantly due to the relatively smaller modification on large intact proteins. Thus, the ionization/detection efficiency of intact phosphoprotein is hypothesized not to alter appreciably for subsequent MS quantification. However, this hypothesis has never been rigorously tested. Herein, we systematically investigated the impact of phosphorylation on ESI-MS quantification of mono- and multiply phosphorylated proteins. We verified that a single phosphorylation did not appreciably affect the ESI-MS quantification of phosphoproteins as demonstrated in the enigma homolog isoform 2 (28 kDa) with monophosphorylation. Moreover, different ionization and desolvation parameters did not impact phosphoprotein quantification. In contrast to monophosphorylation, multiphosphorylation noticeably affected ESI-MS quantification of phosphoproteins likely due to differential ionization/detection efficiency between unphosphorylated and phosphorylated proteoforms as shown in the pentakis-phosphorylated ß-casein (24 kDa).


Assuntos
Fosfoproteínas/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Proteínas Adaptadoras de Transdução de Sinal/análise , Proteínas Adaptadoras de Transdução de Sinal/metabolismo , Caseínas/análise , Caseínas/metabolismo , Cromatografia Líquida de Alta Pressão , Humanos , Proteínas com Domínio LIM/análise , Proteínas com Domínio LIM/metabolismo , Fosfopeptídeos/análise , Fosfoproteínas/metabolismo , Fosforilação , Proteômica
13.
Anal Chem ; 89(10): 5467-5475, 2017 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-28406609

RESUMO

Mass spectrometry (MS)-based top-down proteomics is a powerful method for the comprehensive analysis of proteoforms that arise from genetic variations and post-translational modifications (PTMs). However, top-down MS analysis of high molecular weight (MW) proteins remains challenging mainly due to the exponential decay of signal-to-noise ratio with increasing MW. Size exclusion chromatography (SEC) is a favored method for size-based separation of biomacromolecules but typically suffers from low resolution. Herein, we developed a serial size exclusion chromatography (sSEC) strategy to enable high-resolution size-based fractionation of intact proteins (10-223 kDa) from complex protein mixtures. The sSEC fractions could be further separated by reverse phase chromatography (RPC) coupled online with high-resolution MS. We have shown that two-dimensional (2D) sSEC-RPC allowed for the identification of 4044 more unique proteoforms and a 15-fold increase in the detection of proteins above 60 kDa, compared to one-dimensional (1D) RPC. Notably, effective sSEC-RPC separation of proteins significantly enhanced the detection of high MW proteins up to 223 kDa and also revealed low abundance proteoforms that are post-translationally modified. This sSEC method is MS-friendly, robust, and reproducible and, thus, can be applied to both high-efficiency protein purification and large-scale proteomics analysis of cell or tissue lysate for enhanced proteome coverage, particularly for low abundance and high MW proteoforms.


Assuntos
Proteínas/análise , Proteômica/métodos , Cromatografia em Gel , Cromatografia Líquida de Alta Pressão , Cromatografia de Fase Reversa , Creatina Quinase Forma MM/análise , Creatina Quinase Forma MM/isolamento & purificação , Creatina Quinase Forma MM/metabolismo , Humanos , Peso Molecular , Miocárdio/metabolismo , Proteínas/isolamento & purificação , Proteínas/metabolismo , Espectrometria de Massas em Tandem
14.
Anal Chem ; 88(3): 1885-91, 2016 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-26729044

RESUMO

Recent progress in top-down proteomics has led to a demand for mass spectrometry (MS)-compatible chromatography techniques to separate intact proteins using volatile mobile phases. Conventional hydrophobic interaction chromatography (HIC) provides high-resolution separation of proteins under nondenaturing conditions but requires high concentrations of nonvolatile salts. Herein, we introduce a series of more-hydrophobic HIC materials that can retain proteins using MS-compatible concentrations of ammonium acetate. The new HIC materials appear to function as a hybrid form of conventional HIC and reverse phase chromatography. The function of the salt seems to be preserving protein structure rather than promoting retention. Online HIC-MS is feasible for both qualitative and quantitative analysis. This is demonstrated with standard proteins and a complex cell lysate. The mass spectra of proteins from the online HIC-MS exhibit low charge-state distributions, consistent with those commonly observed in native MS. Furthermore, HIC-MS can chromatographically separate proteoforms differing by minor modifications. Hence, this new HIC-MS combination is promising for top-down proteomics.


Assuntos
Interações Hidrofóbicas e Hidrofílicas , Internet , Espectrometria de Massas , Proteômica/métodos , Animais , Aprotinina/análise , Bovinos , Galinhas , Cromatografia , Quimotripsinogênio/análise , Cavalos , Lactoglobulinas/análise , Muramidase/análise , Muramidase/metabolismo , Ribonuclease Pancreático/análise , Ribonuclease Pancreático/metabolismo , Tripsinogênio/análise
15.
Anal Chem ; 90(24): 14643, 2018 12 18.
Artigo em Inglês | MEDLINE | ID: mdl-30522269
16.
Anal Chem ; 90(1): 110-127, 2018 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-29161012
17.
J Chromatogr A ; 1710: 464414, 2023 Nov 08.
Artigo em Inglês | MEDLINE | ID: mdl-37806043

RESUMO

In this study, we aimed to develop a hydrophilic interaction liquid chromatography (HILIC) method for the analysis of single guide ribonucleic acid (sgRNA), a critical reagent used in CRISPR genome editing. Our results showed that effective profiling of sgRNA can be achieved by suppressing the surface charge of the stationary phase in HILIC. We identified hydrogen bonding as the primary retention mechanism with potential weak partitioning in HILIC separation of large oligonucleotides like 100-mer sgRNA. Moreover, we demonstrated that direct coupling of HILIC with mass spectrometry (MS) allows the intact mass analysis of sgRNA and its impurities with minimal adduct present. Finally, we characterized the post peak shown in the low temperature HILIC and identified it as sgRNA aggregates. Our findings provide valuable insight into the characterization of sgRNA and highlight the potential of HILIC-MS as a powerful analytical tool for relatively large oligonucleotide analysis.


Assuntos
Oligonucleotídeos , RNA Guia de Sistemas CRISPR-Cas , Espectrometria de Massas , Cromatografia Líquida/métodos , Oligonucleotídeos/análise , Interações Hidrofóbicas e Hidrofílicas
18.
bioRxiv ; 2023 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-37609276

RESUMO

Supramolecular hydrogels formed through polymer-nanoparticle interactions are promising biocompatible materials for translational medicines. This class of hydrogels exhibits shear-thinning behavior and rapid recovery of mechanical properties following applied stresses, providing desirable attributes for formulating sprayable and injectable therapeutics. Characterization of hydrogel composition and loading of encapsulated drugs is critical to achieving desired rheological behavior as well as tunable in vitro and in vivo payload release kinetics. However, quantitation of hydrogel compositions is challenging due to material complexity, heterogeneity, high molecular weight, and the lack of chromophores. Here, we present a label-free approach to simultaneously determine hydrogel polymeric components and encapsulated payloads by coupling a reversed phase liquid chromatographic method with a charged aerosol detector (RPLC-CAD). The hydrogel studied consists of modified hydroxypropylmethylcellulose, self-assembled PEG-b-PLA nanoparticles, and a therapeutic compound, Bimatoprost. The three components were resolved and quantitated using the RPLC-CAD method with a C4 stationary phase. The method demonstrated robust performance, applicability to alternative cargos (i.e. proteins), and was suitable for composition analysis as well as for evaluating in vitro release of cargos from the hydrogel. Moreover, this method can be used to monitor polymer degradation and material stability, which can be further elucidated by coupling the RPLC method with high resolution mass spectrometry and a Fourier-transform based deconvolution algorithm. To our knowledge, this is the first RPLC-CAD method for characterizing the critical quality attributes of supramolecular hydrogels. We envision this analytical strategy could be generalized to characterize other classes of supramolecular hydrogels, establish structure-property relationships, and provide rational design guidance in hydrogel drug product development.

19.
J Pharm Biomed Anal ; 211: 114622, 2022 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-35131673

RESUMO

In pharmaceutical development, structural elucidation of small molecules from process related impurities and degradation products is an essential component. As one of the most important methods in the toolbox, high resolution mass spectrometry (HRMS) and specifically tandem mass spectrometry (MS/MS) often provide fast and informative structural insights. However, many small molecule drugs containing certain biological relevant pharmacophores result in limited numbers of fragments when using traditional collision based fragmentation techniques, such as higher energy collisional dissociation (HCD), due to its inherent preference of cleaving the weakest bond first. As an alternative, ultraviolet photodissociation (UVPD), which irradiates the precursor ion with high energy photons, can lead to more extensive fragmentation from the readily UV absorbing small molecules. Here, we showcase the advantage of UVPD over HCD on pyrrolidine and piperidine containing molecules derivatized from a model compound, telmisartan. While HCD only yielded a single, highly abundant ion resulting from the pyrrolidine and pipieridine ring cleavage, UVPD generated rich and structurally informative fragment ions. UVPD is an attractive and powerful alternative for traditional fragmentation techniques for small molecule structural elucidation.


Assuntos
Espectrometria de Massas em Tandem , Raios Ultravioleta , Íons , Piperidinas , Pirrolidinas , Espectrometria de Massas em Tandem/métodos
20.
J Chromatogr A ; 1665: 462839, 2022 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-35093620

RESUMO

Guide ribonucleic acid (gRNA) is a critical reagent in clustered regularly interspaced short palindromic repeats (CRISPR)/Cas9 genome editing. The single stranded guide RNA (sgRNA) is the most commonly used gRNA in application. Evaluation of the impurity profile of synthetic sgRNA is important for any CRISPR genome editing experiments. However, the large molecular size, complex impurity profile and unique secondary structure pose many challenges in the analysis of sgRNA by ion pairing reversed-phase liquid chromatography (IP-RPLC), the commonly used method. In this work, we developed a generic IP-RPLC method for guide RNA analysis. We found that large pore size of stationary phase was the most critical column parameter to achieve high resolution separation of sgRNA while particle structure, particle size and surface chemistry had less impact. Our results indicated that charge interaction was the most critical mechanism for retention and mass transfer had less impact on the performance of separation. An IP-RPLC/mass spectrometry (MS) method was also developed with a specific practice to reduce adducts and enable intact MS analysis of sgRNAs. The generic IP-RPLC method demonstrates its feasibility to serve as a release, stability, characterization and in-process control testing method for synthetic sgRNA products.


Assuntos
Sistemas CRISPR-Cas , Cromatografia de Fase Reversa , Espectrometria de Massas , RNA , RNA Guia de Cinetoplastídeos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA