RESUMO
AIMS: Data on ventricular pulsed-field ablation (PFA) are sparse in the setting of chronic myocardial infarction (MI). The objective of this study was to compare the biophysical and histopathologic characteristics of PFA in healthy and MI swine ventricular myocardium. METHODS AND RESULTS: Myocardial infarction swine (n = 8) underwent coronary balloon occlusion and survived for 30 days. We then performed endocardial unipolar, biphasic PFA of the MI border zone and a dense scar with electroanatomic mapping and using an irrigated contact force (CF)-sensing catheter with the CENTAURI System (Galaxy Medical). Lesion and biophysical characteristics were compared with three controls: MI swine undergoing thermal ablation, MI swine undergoing no ablation, and healthy swine undergoing similar PFA applications that included linear lesion sets. Tissues were systematically assessed by gross pathology utilizing 2,3,5-triphenyl-2H-tetrazolium chloride staining and histologically with haematoxylin and eosin and trichrome. Pulsed-field ablation in healthy myocardium generated well-demarcated ellipsoid lesions (7.2 ± 2.1 mm depth) with contraction band necrosis and myocytolysis. Pulsed-field ablation in MI demonstrated slightly smaller lesions (depth 5.3 ± 1.9 mm, P = 0.0002), and lesions infiltrated into the irregular scar border, resulting in contraction band necrosis and myocytolysis of surviving myocytes and extending to the epicardial border of the scar. Coagulative necrosis was present in 75% of thermal ablation controls but only in 16% of PFA lesions. Linear PFA resulted in contiguous linear lesions with no gaps in gross pathology. Neither CF nor local R-wave amplitude reduction correlated with lesion size. CONCLUSION: Pulsed-field ablation of a heterogeneous chronic MI scar effectively ablates surviving myocytes within and beyond the scar, demonstrating promise for the clinical ablation of scar-mediated ventricular arrhythmias.
Assuntos
Ablação por Cateter , Infarto do Miocárdio , Taquicardia Ventricular , Suínos , Animais , Cicatriz , Miocárdio/patologia , Ventrículos do Coração , Coração , Arritmias Cardíacas , Ablação por Cateter/métodosRESUMO
BACKGROUND: Pulsed field ablation (PFA) may have a superior safety profile compared to other technologies, but it has the potential to cause gaseous microbubbles (MB), which may be associated with cerebral emboli. Limited relative safety data has been published regarding PFA in the left ventricle (LV). METHODS: Healthy and chronic myocardial infarction (MI) swine underwent PFA (monopolar, biphasic, 25 Amps) in the LV using an irrigated focal catheter under intra-cardiac echocardiography (ICE) guidance for MB monitoring. Two control swine received air MBs through the lumen of the ablation catheter. Swine underwent brain MRI before and after PFA (or control air MB injection). Gross pathology and histology of brains with abnormal MRI findings were performed. RESULTS: Four healthy and 5 chronic MI swine underwent 124 left ventricular PFA applications. No PFA-related MB formation was noted on ICE. Both control swine developed multiple acute emboli in the thalamus and caudate on DWI, ADC, and FLAIR brain MRI images in response to air MB injection. Of the 9 PFA swine, there were no abnormalities on ADC or FLAIR images. There was one hyperintense focus in the left putamen on the DWI trace image, but the absence of ADC or FLAIR affirmation suggested it was artifact. Gross pathology and histopathology of this region did not detect any abnormalities. CONCLUSIONS: Focal monopolar biphasic PFA of both healthy and chronically infarcted left ventricular myocardium does not generate any MB or cerebral emboli observable on ICE and brain MRI.