1.
J Occup Environ Hyg ; 2(7): 368-73, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-16020100

RESUMO

Sixteen subjects exercised at 80-85% of maximal aerobic capacity on a treadmill while wearing a tight-fitting, FRM40-Turbo Powered Air Purifying Respirator (PAPR). The PAPR was powered by a DC power supply to give flow rates of 0%, 30%, 66%, 94%, and 100% of rated maximum blower capacity of 110 L/min. As flow rate was reduced, so was performance time. There was a 20% reduction in performance time as blower flow changed from 100% to 0% of maximum. Significant differences in breathing apparatus comfort and facial thermal comfort were found as flow rate varied. It was concluded that inadequate blower flow rate decreases performance time, facial cooling, and respirator comfort.


Assuntos
Exercício Físico/fisiologia , Dispositivos de Proteção Respiratória , Adolescente , Adulto , Regulação da Temperatura Corporal , Desenho de Equipamento , Teste de Esforço , Feminino , Humanos , Masculino , Resistência Física , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA